Air Conditioning Operation and Troubleshooting Matt Dunham

Similar documents
SERVICING PROCEDURE R-410A LEAK TEST EVACUATION CHARGING. Bard Manufacturing Company, Inc. Bryan, Ohio Manual Page 1 of 11

Table of Contents. Service Procedures. Service Procedures. Measuring Superheat (4) Measuring Subcooling (5) Airflow Calculation (6-8)

Calhoon MEBA Engineering School. Study Guide for Proficiency Testing Refrigeration

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

KITS COMMON TO HEATING AND COOLING EQUIPMENT 504,652M 03/04. Supersedes 503,249M

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

HOSHIZAKI MODULAR CRESCENT CUBER MODEL KM-280MAH KM-280MWH SERVICE MANUAL

Refrigeration System with a Capillary Tube and a Thermostat

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Commercial High-Efficiency Condensing Units

Condensing Unit Installation and Operating Instructions

KM-1600MRF KM-1600MRF3

KML F SERIES KML H SERIES

NUMBER: ISSUED: JULY 13, /336 73/23 STACKABLE CRESCENT CUBER KM-1300SWH-E SERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI

Hoshizaki America, Inc.

User s Information and Installation Instructions

User s Information and Installation Instructions

KM-900MAF KM-900MWF KM-900MRF KM-900MRF3

HS25 SERVICE UNIT INFORMATION

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

KM-630MAF KM-630MWF KM-630MRF

INSTALLATION INSTRUCTIONS

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

R100 Oil-Less Refrigerant Recovery Unit

HPXA15 HPXB15 WARNING

SERVICE MANUAL FOR QUALIFIED SERVICE PERSON HOSHIZAKI 89/336 73/23 SELF-CONTAINED CRESCENT CUBER KM-150BAF-E KM-150BWF-E

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

F-2000MLF(-C) F-2000MWF(-C) F-2000MRF(-C) F-2000MRF3(-C)

INSTALLATION AND MAINTENANCE INSTRUCTIONS 4SCU16LT Series Split System Air Conditioner WARNING

WineZone Ceiling Mount Ductless Split 15

SERVICE MANUAL FOR MODEL RM-10

Hoshizaki America, Inc.

Hoshizaki America, Inc.

Installation Instructions

Reliability is a beautiful thing TM MODULAR CRESCENT CUBER KM-500MAH KM-500MWH KM-500MRH SERVICE MANUAL

Installation Owner Diagnostics

SERVICE MANUAL FOR MODEL RM-49

DCM-500BAF DCM-500BWF DCM-750BAF DCM-750BWF

Hoshizaki America, Inc.

LENNDX INSTALLATION INSTRUCTIONS. IIlIIIIIIIIIIIIIIIIIIIIIIIHI A, WARNING A, WARNING WARNING RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE

SERVICE MANUAL FOR MODEL RM-26

Grades Prentice Hall. Fundamentals of HVAC/R HVACR High School ISBN's SE / IG Grades 9-12

REFRIGERANT RECOVERY Log Book

Hoshizaki America, Inc.

Installation Instructions

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

Condensing Unit Installation and Operating Instructions

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Heat Pump Water Heater. Table of Contents

INSTRUCTIONS! DO NOT DISCARD!

Hoshizaki America, Inc.

Liebert Prop Fan Condensing Unit

INSTALLATION INSTRUCTIONS

Refrigerant Recovery Unit, Model RRU134

XC13. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R410A.

HOSHIZAKI CUBELET ICE DISPENSER MODEL DCM-240BAF SERVICE MANUAL

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

INSTALLATION AND OPERATING INSTRUCTIONS

The Essentials Of Working With R-410A

Copeland Scroll Condensing Units for the Food Service Market

HVAC Basics RESIDENTIAL AIR CONDITIONING

horizontal air discharge outdoor discus condensing unit

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

1 Specifications. 2 Operation. PHOENIX 300 Operation & Service Instructions. 2.1 Transporting the Phoenix. 2.2 Location

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

MACH N-407 Heat Pump Air-Cooled Chiller

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

XC16. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R410A.

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Residential Piping and Long Line Guideline

SCE170 SERVICE PARTS

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

INSTALLATION INSTRUCTIONS

Hoshizaki America, Inc.

Contour TM Screw Compressors

Refrigerant changeover guidelines

Hoshizaki America, Inc.

Hoshizaki America, Inc.

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

KM-630MAH KM-630MWH KM-630MRH

13ACX. IMPORTANT Operating pressures of this R 410A unit are higher than pressures in R 22 units. Always use service equipment rated for R 410A.

INSTALLATION GUIDE. 4AC 14* ASA1 SERIES R-410a CONDENSING UNITS R-410A ATTENTION, INSTALLER! ATTENTION, USER!

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

INSTALLATION INSTRUCTIONS

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

Hoshizaki America, Inc.

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

Hayward/Summit Heat Pump Troubleshooting Guide Hayward Industries

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Transcription:

Air Conditioning Operation and Troubleshooting Matt Dunham Major Components (10 Minutes) Compressor heart of the system, causes refrigerant to flow by increasing the pressure of the refrigerant Metering Device fixed orifices and modulating (Expansion Style) o Thermostatic Expansion Device o Electronic Expansion Device Evaporator Absorbs heat into the refrigeration cycle. Condenser Rejects heat from the refrigeration cycle. Additional Components Indoors Evaporator and metering device Outdoors Compressor and Condenser Two connection lines o Suction Line - Larger line, typically insulated, vapor state, low pressure side o Liquid Line Smaller line, un-insulated, liquid state, high pressure Refrigerants (10 Minutes) R-22 (HCFC) o Contains chlorine, which is destructive to the ozone layer o Phased out of new equipment Jan 1, 2010 o Scheduled for no production January 1, 2020 o Typical operating pressures, Page 1 of 8

Low Pressures 55-80 PSIG, High Pressure 200-275 PSIG o Low Side Test Pressure 150 PSIG o High Side Test Pressure 300 PSIG o Mineral Oils or alkybenzines R-410A (HFC) o Zero Global Warming Potential o Runs much higher pressures o Typical operating pressures, Low Pressures 100-150 PSIG, High Pressure 315-450 PSIG o All equipment must be rated for 800 PSIG. o Low Side Test Pressure 450 PSIG o High Side Test Pressure 800 PSIG o POE Oils (Polyol Ester Oils) Conversion Equipment is not interchangeable. R-410A has the much higher test pressure Oils are not interchangeable, when mixed mineral oils and POEs turn into a chalky white power. Only the copper tubing can be reused, and should be flushed to remove mineral oil. Note: Manufactures are selling condensing units that are rated for R-22 and R-410A. They come charged with dry nitrogen. Sequence of Operation (10 Minutes) 1. Thermostat calls for cooling, closes from R-Y and R-G. 2. Fan relay is energized fan cycles on High speed. 3. Call for cooling passes through all safeties; low pressure switch, high pressure switch, compressor lockout, and time delay. Page 2 of 8

4. Cooling contactor energized powering the compressor and condenser fan. Electrical Components Indoor Fan Motor Compressor Condenser Fan Motor Capacitor Contactors Low Pressure Switch High Pressure Switch Time Delay Troubleshooting (35 Minutes) Two major categories o Electrical Problems o Refrigerant Problems Electrical Troubleshooting o Identify power sources. SSU, circuit breaker Transformer provides 24V power o Identify consumers of power Motors Coils Transformers Valves o Identify paths of electrical flow Wiring Fuses o Identify controlling devices Switches Contacts Triacs (Circuit Boards) Page 3 of 8

Checking Power Sources Meter set to voltage reading, one lead on L1 (Power, Hot), other lead on L2 (Common, Neutral) Reading should be the rated voltage +/- 10 percent o 24 V should be 24 +/- 2.4 volts or 22.6 to 26.4. Checking Power Consumers (Loads) Use meter to ensure voltage is reaching device. o One lead on the power source L2, with the other lead check for the L1 voltage at the device. Use meter to check continuity. o NOTE: Turn off power to unit. o Disconnect wiring from load to check o Set meter to continuity (ohms) place one lead on each side of the device where power is attached. Reading should be between 0 and OL (open line) for most devices. Manufacture may provide the precise reading. Use meter to check amp readings o Unit is running for these checks. o Meter is set to amps and clamped around one leg of power going to the load. Reading should be within 10 percent of the rated amp reading for the device. Checking Paths of Electrical Flow Use meter set to voltage, with one lead on the power source L2 utilize the hop-scotch method to identify were voltage is no longer present. The problem is just before this point. Page 4 of 8

Checking Controlling Devices Set meter to voltage and utilize the hop-scotch method to identify if there is a switching device that is not closing properly. With power removed continuity may also be check through a switch to identify if it is closing properly. Refrigerant Troubleshooting (20 Minutes) Properly operating system o The indoor coil should be cooler than the air passing over it. o The suction line will most likely be cool to the touch. o Air coming off the condenser will feel warm. o Liquid line will typically not feel hot or cold to the touch. o Discharge air to the conditioned space will be around 55ºF. Common Causes for Refrigerant Problems o Low Air Flow Dirty Filter Vegetation Cottonwood Bad indoor fan motor Bad condenser fan motor o Low Refrigerant Charge Visible signs of oil on piping or coils. Bubbles in a sight glass Evaporator coil developing ice Compressor running, suction line is not cool to the touch Page 5 of 8

Troubleshooting Compressors Motor Terminals, Common (C), Start (S), Run (R) Checking compressor windings Run to Common Lowest Resistance Run to Start Highest Resistance Common to Start Intermediate resistance Note: R-S = C-S + C-R and C-S is normally 3-4 times greater than C-R Common Compressor Failures Electrical Failures Burnout Winding inside the compressor shell overheat and burn up. Insulating coating on windings is burned. Once removed piping should be flushed with a refrigeration system flush to avoid contaminating new compressor. Compressor shorted to ground. Ohm reading between the compressor terminals and ground is around 0 ohms. Thermal overload will not reset. If thermal overload is tripped, remove power and allow time for the compressor to cool off, usually 1 hour. Mechanical Failure Locked Rotor The compressor has seized up internally and the amp draw when the compressor tries to Page 6 of 8

start will be equal to or greater than the locked rotor amps (LRA) of the compressor. Bad valves Typically with valves that have went bad in a compressor the amp draw of the compressor will be significantly lower than the full loaded amps (FLA) of the compressor. There will also be a lower pressure increase across the compressor from low to high pressure. Compressor Replacement (25 Minutes) 1. Lock out power to the unit and disconnect electrical from the compressor. 2. Determine if compressor was a burnout or not. If compressor burned out refrigerant will be recovered and then must be disposed of properly. 3. Recover refrigerant from the system into a DOT approved cylinder. 4. Use the appropriate tools to disconnect the existing compressor from the refrigerant lines. 5. Unbolt and remove the compressor physically from the condensing unit. 6. Mount the new compressor in the unit. 7. Install a liquid line filter dryer. Caution protect the filter dryer from overheating with wet rags while brazing in place. 8. Purge the system with dry nitrogen while reconnecting the refrigerant lines. 9. Pressure test the system with nitrogen to ensure no additional leaks, do not exceed the low side test pressure. Typically150 PSIG for R-22, 450 PSIG for R-410a. Page 7 of 8

10. Use a vacuum pump and thermister gauge to draw the system into a deep vacuum. This should be below 500 microns. 11. Fill the system with the appropriate refrigerant to the proper level. This should be the factory charge, plus any additional charge required for additional line set lengths. Most factory charges account for a 15 20 foot line set. 12. Reconnect all electrical to the compressor. It is recommend to replace the contactor and capacitor at this time as well. 13. Follow the manufactures startup recommendations for the new compressor and record all values properly for potential warranty issues. 10 Minutes Questions and Answers Page 8 of 8