seer 4HP16LT Split System Enhanced Heat Pump Features and Benefits WARRANTY

Similar documents
16 SEER Split System Enhanced Heat Pump 4SHP16LT. Features and Benefits WARRANTY

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

RSG16**S1M. Split System Air Conditioner 16 SEER

4SCU16LS PRODUCT SPECIFICATIONS 16 SEER SPLIT SYSTEM TWO-STAGE AIR CONDITIONER COMPONENTS WARRANTY COMPRESSOR CABINET COILS DESIGN

Cooling & Heating Products Residential and Commercial

Whirlpool Split System 13 SEER Air Conditioner W2C3. Features

2 shp 13 lc 1 36 t - 1 a

TECHNICAL SPECIFICATIONS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

TECHNICAL SPECIFICATIONS

R4H4. Product Specifications

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

Commercial High-Efficiency Condensing Units

WCH5**4. Product Specifications

R4H4. Product Specifications

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

DSXC18 Split System Air Conditioner

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEM PRODUCTS Built Exclusively for Manufactured Housing

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

PRODUCT SPECIFICATIONS

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

N4H4. Product Specifications

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

16 SEER TWO-STAGE AIR CONDITIONERS

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

Ruud Achiever Series Air Conditioners

SPLIT SYSTEM AIR CONDITIONERS, HEAT PUMPS AND PACKAGED SYSTEMS

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

TECHNICAL SPECIFICATIONS

13 SEER CONDENSING UNITS & AIR HANDLERS

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. Fig. 1 - Unit 50VR -A

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

T P A 120 S 4 S N 1 Y

T S A 048 S 4 N 4 1 T

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Commercial High-Efficiency Condensing Units

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

13 GEP A L P - 1 A

Condensing Units & Air Handlers

TECHNICAL SPECIFICATIONS

36,000-62,000 BTUH Nominal Capacity

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

CONDENSED CATALOG RESIDENTIAL PRODUCTS

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Infinity 16 Heat Pump with Puron Refrigerant

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

TECHNICAL SPECIFICATIONS

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

SPLIT SYSTEM HEAT PUMPS 14 SEER

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

PAJ3. Product Specifications

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

A 14 SEER Heat Pump with R---410A Refrigerant Series

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

AND WORRY-FREE PERFORMANCE

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

INDUSTRY LEADING FEATURES 2 5 / BENEFITS

Transcription:

Split System Enhanced Heat Pump 16 COMPRESSOR High-efficiency 2 stage Copeland Ultra Tech scroll compressor R410a refrigerant Grommet mounted compressor for quiet operation Internally protected against high temperature motor overload conditions Features and Benefits seer R-100 (10/2011) CABINET Full metal louvered panel coil guard protection Controls located in corner post for easy installation and service Rounded corners for safety and attractive, clean appearance Baked polyester paint finish over galvanized steel for maximum durability PVC coated wire fan discharge grill External gauge ports for easy service Raised base pan with ports allows for excellent water and debris drainage COMPONENTS Full metal louvered panels remove for easy coil cleaning and service Bi-directional filter drier for long-lasting durability and system protection Discharge muffler for quiet operation Factory installed crank case heater Advanced design defrost system featuring a smart logic for power consumption savings Service valves positioned for quick installation and easy service Comfort Alert 2 diagnostics factory installed Reliable, solid state defrost control Defrost control is Quiet Shift capable DESIGN Designed for ambients up to 125 F COIL Enhanced aluminum fins and copper tubing for high efficiency and capacity Raised coil prevents debris from collecting in bottom of coil and causing loss of airflow FACTORY INSTALLED ACCESSORIES Crank case heater Compressor sound cover for quiet operation High pressure switch Low pressure switch for loss of charge protection WARRANTY 10 year limited warranty on compressor, 10 year limited warranty on all parts, extended warranty available* *Warranty provides for a total of 10 years of limited warranty coverage (Standard 5-year limited parts warranty plus an additional 5-year limited extended parts warranty). Warranty must be registered online within 60 days of installation to qualify for 10-year coverage. Unregistered equipment defaults to 5-year coverage. Lifetime limited heat exchanger warranty applies to registered equipment only (Standard 20 years with no online registration). See full warranty at www.alliedair.com for terms, conditions and exclusions.

Number Guide 4 HP 16 LT 24 P - 2 A 4 - R410 Heat Pump 16-16 SEER Nominal Louvered Two Stage Minor Revision Code Major Revision Code Voltage P - 208-230v/60hz1Ph Nominal Capacity 24-24,000 Btuh Physical and Electrical Voltage/Hz/ Phase Voltage Range Min. Circuit Amp. Max. Over current Device (amps) Compressor Load (amps) Locked Rotor (amps) Load (amps) Fan Motor HP Nom. RPM Refrig. Charge (oz.) Weight (lbs.) 24P-1 208-230-60/1 197-253 13.5 20 11.4 52 0.7 1/10 1075 146 207 36P-1 208-230-60/1 197-253 22.5 35 19.0 82 1.7 1/4 825 192 253 48P-1 208-230-60/1 197-253 28.2 45 24.0 96 1.8 1/3 825 236 288 60P-1 208-230-60/1 197-253 35.1 60 26.0 118 2.8 1/3 ECM 244 313 Unit Dimensions (in.) and Sound Ratings No. Dimensions A B C Sound Rating dba 24P-1 24-3/4 26-3/4 33-3/4 73 36P-1 29-3/8 31-1/4 37-3/4 75 48P-1 35-3/4 37-3/4 37-3/4 75 60P-1 35-3/4 37-3/4 43-3/4 74 FPO - Page 2 -

Cooling Performance with Evaporator Coils Split System Heat Pump 16 SEER Evaporator Coil 3 SEER EER Cooling AHRI Capacity 1 BTUH Sensible Capacity BTUH HSPF Heating 47 17 Btuh COP Btuh COP CFM Connection Line Size Expansion Device Piston 2 TXV 24P-1 36P-1 48P-1 E*1P29+TDR+TXV 13.0 11.0 23,000 16,600 7.7 23,000 3.0 14,000 2.0 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E*1P36+TDR+TXV 13.0 11.0 23,000 16,600 7.7 23,000 3.0 14,000 2.0 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E*1P36+TDR+TXV 13.0 11.0 35,000 25,400 7.7 36,000 3.0 22,000 2.0 1,310 7/8 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E*1P43+TDR+TXV 13.0 11.0 35,000 25,400 7.7 36,000 3.0 22,000 2.0 1,310 7/8 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P49C 13.0 11.0 47,000 33,500 7.7 45,000 3.0 28,000 2.0 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,M,H)1P62C 13.0 11.0 47,000 33,500 7.7 45,000 3.0 28,000 2.0 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 60P-1 E(U,C,M,H)1P62C 13.0 11.0 59,000 43,000 7.7 59,000 3.3 35,000 2.0 1,920 7/8 3/8 7/8 3/8 1-1/8 3/8 NA H4TXV02 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 3 -

Cooling Performance with Air Handlers and Furnaces 24, 36 Cooling Heating Evaporator Coils or Furnace SEER EER Air Handler 3 ARI Cap. 1 Sensible Cap. HSPF 47 17 Btuh COP Btuh COP CFM Connection Refrig. Line Size Expansion Devise Piston 2 TXV BCS2M24V00NA1P 15.0 12.5 24,000 17,400 8.5 24,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P36B EFV08BC 15.0 12.5 24,000 17,400 8.5 24,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,M,H)1P29B EFV08BC 15.0 12.5 24,000 17,400 8.5 24,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P29A 80G1DF045AE12 14.5 12.0 24,000 17,400 8.5 22,600 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P36A 80G1DF045AE12 14.5 12.0 24,000 17,400 8.5 22,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P29B 80G1DF070BE12 14.0 12.0 24,000 17,400 8.5 22,600 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P36B 80G1DF070BE12 14.0 12.0 24,000 17,400 8.5 22,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P29A 80G1UH045AE12 14.5 12.0 24,000 17,400 8.5 22,600 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P36A 80G1UH045AE12 14.5 12.5 24,000 17,400 8.5 22,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P29B 80G1UH070BE12 14.0 12.0 24,000 17,400 8.5 22,600 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 24P-2 E(U,C,M,H)1P36B 80G1UH070BE12 14.0 12.0 24,000 17,400 8.5 22,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P36B 80G2UH090BV16* 14.5 12.5 24,000 17,400 8.5 22,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,M,H)1P29B 80G2UH090BV16* 14.5 12.5 24,000 17,400 8.5 22,600 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P29B 95G2DF045BV12 14.5 12.5 24,000 17,400 8.5 22,600 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P36B 95G2DF045BV12 14.5 12.5 24,000 17,400 8.5 22,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P29B 95G1UH070BE12 14.0 12.0 24,000 17,400 8.5 22,600 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P36B 95G1UH070BE12 14.0 12.0 24,000 17,400 8.5 22,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P29B 95G2UH045BV12 14.5 12.5 24,000 17,400 8.5 22,600 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P36B 95G2UH045BV12 15.0 12.5 24,000 17,400 8.5 22,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P29B 95G2UH070BV12 15.0 12.5 24,000 17,400 8.5 22,600 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P36B 95G2UH070BV12 15.0 12.5 24,000 17,400 8.5 22,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 E(U,C,M,H)1P36C 95G2UH090CV12 15.0 12.5 24,000 17,400 8.5 22,000 3.3 14,000 2.40 850 3/4 3/8 3/4 3/8 3/4 3/8 NA H4TXV01 BCS2M36V00NA1P 15.0 12.5 35,000 25,400 8.5 36,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P36B EFV12BC 15.0 12.5 35,000 25,400 8.5 36,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43B EFV12BC 15.0 12.5 35,000 25,400 8.5 36,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P36B 80G1DF090BE16 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43B 80G1DF090BE16 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 36P-2 E(U,C,M,H)1P36B 80G1UH090BE16 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43B 80G1UH090BE16 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 Note: E(U,C,M,H)1P36B 80G2UH090BV16* 15.0 11.6 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P36B 95G1DF070BE16 14.5 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43B 95G1DF070BE16 14.5 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P36C 95G1DF090CE16 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43C 95G1DF090CE16 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P36B 95G2DF045BV12 15.0 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43B 95G2DF045BV12 15.0 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 4 -

Cooling Performance with Air Handlers and Furnaces 36, 48 Cooling Heating Evaporator Coils or Furnace SEER EER Air Handler 3 ARI Cap. 1 Sensible Cap. HSPF 47 17 Btuh COP Btuh COP CFM Connection Split System Heat Pump 16 SEER Refrig. Line Size Expansion Devise E(U,C,M,H)1P36B 95G2DF070BV16 15.0 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43B 95G2DF070BV16 15.0 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P36C 95G2DF090CV20 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43C 95G2DF090CV20 15.5 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P36C 95G2DF110CV20 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 Piston 2 TXV 36P-2 E(U,C,M,H)1P43C 95G2DF110CV20 15.5 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P36C 95G1UH090CE16 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43C 95G1UH090CE16 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P36B 95G2UH045BV12 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43B 95G2UH045BV12 15.0 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P36B 95G2UH070BV12 15.0 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43B 95G2UH070BV12 15.0 12.0 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P36C 95G2UH090CV12 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43C 95G2UH090CV12 15.5 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P36C 95G2UH090CV20 15.0 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 3/4 3/8 7/8 3/8 NA H4TXV01 E(U,C,M,H)1P43C 95G2UH090CV20 15.5 12.5 35,000 25,400 8.5 35,000 3.3 22,000 2.40 1,310 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV01 BCS2M48V00NA1P 16.0 12.5 47,000 33,500 8.5 46,000 3.2 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P49C EFV16CC 14.5 11.5 46,500 33,100 8.0 46,000 3.0 29,000 2.00 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P62C EFV16CC 14.5 12.0 46,500 33,100 8.0 46,000 3.0 29,000 2.00 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P49C 80G1DF110CE20 14.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P62C 80G1DF110CE20 14.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P49C 80G1UH090CE20 14.5 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 48P-2 E(U,C,H)1P62C 80G1UH090CE20 14.5 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P49C 80G1UH110CE20 14.5 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P62C 80G1UH110CE20 14.5 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 Note: E(U,C,H)1P49C 80G2UH110CV20* 15.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P62C 80G2UH110CV20* 15.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P49C 95G1DF110CE20 14.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P62C 95G1DF110CE20 14.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P49C 95G2DF090CV20 14.5 11.5 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P62C 95G2DF090CV20 15.0 11.5 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 5 -

Cooling Performance with Air Handlers and Furnaces 48, 60 Cooling Heating Evaporator Coils or Furnace SEER EER Air Handler 3 ARI Cap. 1 Sensible Cap. HSPF 47 17 Btuh COP Btuh COP CFM Connection Refrig. Line Size Expansion Devise Piston 2 TXV E(U,C,H)1P49C 95G2DF110CV20 15.0 11.5 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 48P-2 E(U,C,H)1P62C 95G2DF110CV20 15.0 11.5 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P49C 95G1UH110CE20 14.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P62C 95G1UH110CE20 14.0 12.0 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P49C 95G2UH090CV20 15.0 11.5 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P62C 95G2UH090CV20 15.0 11.5 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P49C 95G2UH110CV20 15.0 11.5 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 E(U,C,H)1P62C 95G2UH110CV20 15.0 11.5 47,000 33,500 8.5 46,500 3.3 29,000 2.40 1,600 7/8 3/8 7/8 3/8 7/8 3/8 NA H4TXV02 BCS2M60V00NA1P 15.0 12.5 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 E(U,C,H)1P62D EFV20DC 14.5 11.5 59,000 43,000 8.0 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 E(U,C,H)1P62C 80G1UH090CE20 14.5 11.0 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 E(U,C,H)1P62C 80G1UH110CE20 14.5 11.0 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 E(U,C,H)1P62C 80G2UH110CV20* 14.5 11.4 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 E(U,C,H)1P62D 80G2UH135DV20* 14.7 11.4 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 60P-2 E(U,C,H)1P62C 95G1DF110CE20 14.0 11.0 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 E(U,C,H)1P62C 95G2DF090CV20 14.5 11.4 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 E(U,C,H)1P62C 95G2DF110CV20 15.0 11.4 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 E(U,C,H)1P62C 95G1UH110CE20 14.0 11.0 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 E(U,C,H)1P62D 95G1UH135DE20 14.0 11.0 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 E(U,C,H)1P62C 95G2UH090CV20 15.0 11.4 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 E(U,C,H)1P62C 95G2UH110CV20 15.0 11.4 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 E(U,C,H)1P62D 95G2UH135DV20 15.0 11.4 59,000 43,000 8.5 59,000 3.3 35,000 2.40 1,920 7/8 3/8 7/8 3/8 1 1/8 3/8 NA H4TXV03 Note: 1 Certified in accordance with Unitary Air Conditioner Certification Program, which is based on AHRI Standard 210/240 2 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required. 3 A blower time delay relay is required to achieve AHRI rating. This feature is standard on all Allied Air Enterprises furnace and AH products. - Page 6 -

Cooling Performance Extended Ratings Piston or Field Installed TXV Temp DB/WB ºF Temp - DBºF 65 82 95 105 115 Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw 85/75 32,300 0.59 1.54 29,523 0.61 1.80 27,400 0.63 1.99 24,800 0.69 2.25 22,200 0.74 2.51 24P-1 BCS2M24V+TXV 80/67 29,400 0.65 1.51 26,793 0.70 1.78 24,800 0.73 1.99 22,950 0.74 2.20 21,100 0.75 2.41 75/63 26,700 0.69 1.48 24,490 0.71 1.74 22,800 0.73 1.93 21,550 0.76 2.16 20,300 0.78 2.38 75/57 23,100 0.73 1.45 21,400 0.74 1.71 20,100 0.74 1.90 19,250 0.77 2.00 18,400 0.79 2.10 85/75 45,000 0.60 2.40 42,223 0.66 2.73 40,100 0.71 2.99 31,750 0.80 3.30 23,400 0.89 3.60 36P-1 BCS2M36V+TXV 80/67 42,100 0.61 2.38 39,550 0.68 2.70 37,600 0.73 2.94 30,050 0.82 2.77 22,500 0.91 2.60 75/63 39,300 0.63 2.35 37,033 0.69 2.20 35,300 0.73 2.08 28,550 0.82 2.33 21,800 0.91 2.58 75/57 37,200 0.66 2.31 35,613 0.72 2.12 34,400 0.76 1.98 27,250 0.83 2.04 20,100 0.90 2.10 85/75 52,300 0.62 2.96 51,053 0.64 3.49 50,100 0.66 3.89 47,600 0.74 4.27 45,100 0.82 4.65 48P-1 BCS2M48V+TXV 80/67 50,600 0.68 2.12 49,127 0.70 3.11 48,000 0.72 3.87 45,300 0.77 4.26 42,600 0.81 4.65 75/63 48,300 0.72 2.87 44,730 0.74 3.35 42,000 0.75 3.72 39,500 0.77 4.18 37,000 0.79 4.64 75/57 46,400 0.73 2.86 43,510 0.75 3.34 41,300 0.76 3.71 38,500 0.77 4.11 35,700 0.78 4.51 85/75 74,900 0.62 3.72 69,290 0.65 4.49 65,000 0.68 5.07 61,400 0.68 5.71 57,800 0.68 6.34 60P-1 BCS2M60V+TXV 80/67 69,700 0.69 3.65 64,770 0.71 4.46 61,000 0.73 5.08 55,800 0.77 5.70 50,600 0.81 6.32 75/63 65,100 0.73 3.63 60,170 0.75 4.37 56,400 0.76 4.93 52,050 0.80 5.57 47,700 0.83 6.20 75/57 61,400 0.75 3.58 57,207 0.76 4.28 54,000 0.77 4.81 49,550 0.81 5.48 45,100 0.85 6.14 - Page 7 -

Heating Performance Extended Ratings Piston or Field Installed TXV Temp Temp - DB/WB ºF 0/0 17/15 35/33 47/43 62/56 Btuh kw Btuh kw Btuh kw Btuh kw Btuh kw 24P-2 36P-2 48P-2 60P-2 E(U,C,M,H)1P36B/EFV08B BCS2M24V+TXV E(U,C,M,H)1P43B/EFV12B BCS2M36V+TXV E(U,C,M,H)1P62C/EFV16C BCS2M48V+TXV E(U,C,M,H)1P62D/EFV20D BCS2M60V+TXV 70 12,361 1.64 15,100 1.83 18,000 2.03 24,500 2.17 29,200 2.34 70 15,811 2.04 22,800 2.49 30,200 2.97 40,600 3.55 49,500 4.08 70 28,561 3.32 31,300 3.49 34,200 3.67 46,900 3.59 54,700 3.64 70 36,783 4.04 39,900 4.17 43,200 4.31 60,300 4.73 70,500 5.01 Accessories Description Where Used Kit Catalog No. Hard Start Kit 24 & 36 10J42 48 & 60 81J69 Compressor Low Ambient Kit All s 45F08 Freezestat All s 93G35 Thermostat All s ASTAT503 Fossil Fuel Kit All s AFOSL500 Low Pressure Switch High Pressure Switch Sound Blanket Crankcase Heater Factory installed; see spare parts list Factory installed; see spare parts list Factory installed; see spare parts list Factory installed; see spare parts list Relay Kit - Constant Torque All Constant Torque Furnaces 85W66 Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched with appropriate coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit www.energystar.gov All specifications and illustrations subject to change without notice and without incurring obligations. www.concord-air.com 1-800-448-5872 R-100 (10/2011) 2011 Allied Air Enterprises Inc., a Lennox International Inc. Company Printed in the U.S.A.