Lighting Controls. Energy-Saving Solutions For Efficient Buildings

Similar documents
Reduce lighting energy costs with controls

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

ANSI/ASHRAE/IES

Lighting Control Strategies. to meet code requirements save energy and improve building performance

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2012

LIGHTING CONTROLS

Vive Solutions. Commercial Application Guide Code Compliance Lighting Controls IECC 2015

Wireless Indoor Lighting Control System

ANSI/ASHRAE/IES

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

WEBs-AX. Endless Possibilities For Building Control, Management And Savings

Table of Contents. Fast Fact. Sensor Models 2 Advantages of Sensors 3 FAQs 4-5

Lighting Control Solutions for Parking Facilities

Optimal control for superior lighting performance

LightSweep. Lighting Control System

Advances in Lighting Controls and the Impact of ASHRAE Requirements. Rich Rattray, LC OSRAM SYLVANIA

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

Lighting Controls: The Next Big Thing in Lighting. June 18th, 2014

lighting control Simple and scalable Flexible control every step of the way DESIGN INSTALL MAINTAIN

Applied Lighting Controls

Spaces are over lighted by 10-20% designed for worst-case interiors and fabrics, adjustable systems can tune-out waste

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

DIVISION 26 ELECTRICAL SECTION LIGHTING CONTROL SYSTEM

Fixture Controller. Applications. Features. Specifications. Certifications & Affiliations. Catalog #: ALC/ALCE Part #: /

ESL-IC Smart Room Control

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

Maestro 0 10 V Dimmer Sensor

Advanced Lighting Control for High Building Performance

Product Specifications Dialog Room Controller* (*patent pending)

Lighting Application Guide for K-12 Classrooms

Philips Lighting North America Corporation 200 Franklin Square Drive Somerset, NJ Tel

Connectivity Control Confidence

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

Good-Better-Best LED Retrofit Guide

FCSENS0R Occupancy Sensor. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

Never forget to turn the lights off again. Motion Sensors

Retrofit Solutions NEW. Energy-saving products for single rooms. Lutron energy-saving products. Patient Rooms. Office Spaces. Affordable Solutions

Daylighting Control Design and Application Guide

Wireless Wall-Mount Sensor

Specifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950

UNIVERSAL LIGHTING OFFERS BREAKTHROUGHS FOR BOTH ANALOG AND DIGITAL DIMMING APPLICATIONS

Lighting Controls An Introduction and Review

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

miniz Quick Start Guide

Indoor Controls. SpaceWise SWZG2. Wireless technology

A Guide for Applicants and Lighting Designers

Mini Product Guide.

Ever evolving energy code requirements and the large demand for energy

Light control solutions

LS-CM Series. Overview. Applications. Features & Benefits. Datasheet. Ceiling mount occupancy sensors

In. Out. Here. There. Meet the thermostat designed for how people live.

Ceiling-Mounted Wireless Occupancy/Vacancy Sensor

Advanced Lighting Solutions

Product Comparison Guide. EnOcean 868MHz wireless devices for SmartStruxure TM solution and SmartStruxure Lite solution

Encelium Energy Management System Application and Design Guide

VESICA LINEAR SUSPENDED VES L

Vive wireless hub. BACnet Integration. Demand Response

Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group. Technical Product Information

High Performance Lighting. Terry Egnor Senior Consultant NBI

F series. echoflex. Slim Line Dimming Controller. Product Overview ER1S-FC

600 Watt Dimmer Install Guide

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Code Compliance Commercial Application Guide

Wireless Wall-Mount Sensor

Vive PowPak Fixture Controls

SECTION DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

Excellence in LED Lighting. e-solis Edge Lit LED Panels.

A Simpler and Smarter Wireless Lighting Control Solution. Design & Application Guide

LIGHTING CONTROLS. Smart Enough to Work Right Out of the Box

Aesthetic, energyefficient. control solutions for hospitality facilities QUICK GUIDE TO LIGHTING CONTROL FOR HOTELS

GE LightSweep Lighting Control System Guideform Specification

Volume 1: Basic devices and single-space systems

Product Comparison Guide

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

Code Review TITLE PRESENTED BY POURIA NIKNAM

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

Shannon J Markey LC, LEED AP Legrand BCS / Wattstopper Western Regional Manager. Yesterday, Today & Tomorrow

Miro Wireless Dimming and Scene Control Made Elegantly Simple

Lighting and Fan Speed Controls

design guide for wireless l i g h t i n g c o n t r o l

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

Sensors. EasyAir. office sensor advanced grouping SNS200. Design-in Guide. Single, compact, cost-effective luminaire control

A. Furnish and install wiring devices and plates as specified herein and as shown on the Drawings.

Wireless Lighting Control Made Easy

Honeywell Steam Humidifier Operates independently to maintain optimal humidity

Design and Commissioning of Lighting Control Systems. Rick Miller, PE, LC, LEED AP RNM Engineering, Inc. October 18, 2012

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD

IN2 Lighting Control Devices

F series. Complete Room Controller. echoflex Powered by ETC. Product Overview ERDRC-FC

Welcome, and thank you for joining us today!

Reference Design. classrooms. Eckerd College, Florida

PRELIMINARY COPY. RadioRA 2. Save energy with wireless total home control from Lutron

Hubbell Controls Application Guide to ASHRAE 90.1 A SUPPLEMENTAL GUIDE TO CODE REVISIONS IMPACTING LIGHTING CONTROL

Manufacturing. Industrial Lighting & Controls Solutions

An-10 Wireless lighting control technology

An-10 Wireless lighting control technology

Sensors and Detectors

Transcription:

Lighting Controls Energy-Saving Solutions For Efficient Buildings

Honeywell Lighting Controls Deliver Light When You Need It And Energy Savings When You Don t Businesses, schools and government facilities spend thousands of dollars each month to light unoccupied rooms, offices, warehouses and more. And they spend still more to operate lights in areas that are already bright from natural light. Honeywell Lighting Controls can make lighting much more efficient. The Honeywell Lighting Controls Solution offers smart scheduling, presence detection and photocells to ensure lights aren t left burning in vacant areas and that lights are off in areas where there s already plenty of natural light. New lighting technologies such as LED fixtures with 0-10v dimming open up lighting control to HVAC contractors to deliver daylight harvesting, demand response and task tuning strategies that previously required expensive, proprietary lighting control equipment. It all adds up to truly significant energy savings as a standalone solution or as part of an overall integrated energy management plan that can integrate lighting control with Honeywell heating, ventilation and air conditioning (HVAC), security and building automation products.

Building a Lighting Strategy The goal of a well-designed lighting control system is to reduce energy consumption while providing adequate light for the task at hand. A 2012 study by Lawrence Berkeley National Laboratory (LBNL) showed that individual control strategies save between one-quarter and one-third of lighting energy, while combining multiple controls strategies can drive nearly 40 percent savings.* Key Lighting Control Strategies Lighting Zones Different areas of a building have different lighting needs. A large open office space might need the lights on all day, but could save energy by turning most of the lights off at night. Lighting in a conference room that is only used intermittently could be turned off until someone enters the room. Areas near windows can take advantage of natural daylight by dimming lights during the day. Each of these lighting zones can be managed with one or more lighting strategies. Well-planned lighting zones and the lighting control strategies used to manage them should be identified based on how much light is needed, where and when. Switching Switching lights on and off is the most basic form of lighting control. Unfortunately, lights are often left burning when they are not needed. A simple switch connected to a vacancy detector can be a powerful, inexpensive tool to reduce energy use in areas like closets and conference rooms. Smart Time Scheduling A smart scheduling system for lighting controls manages light levels based on time of day and day of the week. A typical open office space or retail business might have all lights on during business hours and rely on switches and vacancy detectors after hours. Occupancy/Vacancy Detection Vacancy detectors save energy by turning off lights when areas are vacant. Occupancy sensors add convenience by turning lights on when the device senses human presence. These devices can range from a simple passive infrared detector built into a light switch to a networked detector that controls lighting and also contributes to an integrated building automation strategy sharing occupancy/vacancy information with other components of a building automation system.

Dimming Dimming can maximize the energy savings of lighting control strategies by dropping light levels to their most effective level. Fluorescent lighting, while efficient, typically does not respond well to dimming. New LED technology offers enhanced 0-10v dimming that not only saves energy but can improve the comfort of a space by bringing lighting to the level that best suits the use of the room. High-End Task Tuning Commercial buildings are typically over-illuminated. Light levels may have been designed for paperwork, while typical office tasks have switched to self-lit computer screens. High-End Task tuning saves energy by setting light levels to the correct, safe, comfortable level for the task. Daylight Harvesting Utilizing dimming technology, or on/off switching, daylight harvesting saves energy by reducing light levels where there is enough ambient light through windows, skylights or other sources. Photo sensors for daylight harvesting can be a data point in an integrated lighting control network or work with a standalone system. Load Shedding/Demand Response To cut peak demand and reduce stress on the electric power grid, many utilities offer load shedding or demand response programs in exchange for incentives or lower energy costs. Networked lighting control systems can take advantage of these programs by temporarily reducing light levels in response to a signal from the utility. *http://lightingcontrolsassociation.org/lbnl-estimates-averageenergy-savings-for-popular-lighting-control-strategies/ Scene Selection/Personal Control Pre-set lighting scenes allow the occupants of a space to match lighting levels to changing needs during the workday. Lighting scenes may include turning off lights in the front of a classroom for a film, raising light levels for detailed tasks, dimming lights to create a mood, or turning off half the lights to reduce energy use. Integration With Building Automation Systems An open, non-proprietary Lighting Controls network allows Lighting, HVAC and Security systems to share occupancy signals across building control systems and enables off site monitoring, control and optimization for ongoing energy efficiency. Fewer than 10% of commercial buildings in North America have Lighting Control networks.

Applications Overview From the office to the warehouse, Honeywell offers a wide range of lighting controls to meet every need. Choose from an array of wired and wireless solutions, control options, dimmers, occupancy/vacancy sensors and more all easy to install and easy to use. Conference Room/ Large Office 3-Circuit Lighting Stryker connected to 0-10v dimming light fixtures. Photo sensor to balance natural and artificial light for optimal light level. Occupancy detector to keep lights off when not needed. TR75 Zio Plus wall module for end-user control of dimming/ scene selection. Optional integration with BACnet Building Control System. OFFICE Individual Offices Without Windows Wireless switch with ceiling-mounted wireless occupancy sensors. Hallway Wireless switch with up to 5 ceiling-mounted wireless occupancy sensors. Storage Closet Wired Wall Box Occupancy Sensor. Stairwell 1-Circuit Lighting Stryker connected to 0-10v dimming light fixtures. Occupancy detector to hold all stairwell fixtures at minimum required footcandles at floor level when vacant and to brighter, userdefined footcandles when occupied.

Kitchen/Cafeteria 5-Circuit Lighting Stryker connected to 0-10v dimming light fixtures. Photo sensor to balance natural and artificial light for optimal light level. TR75 Zio Plus wall module for end-user control of dimming/scene selection. Zone scheduled to hold lighting on when cafeteria is open and operate on occupancy sensor when cafeteria is closed. Optional integration with BACnet Building Control System. Open Office Area 5-Circuit Lighting Stryker connected to 0-10v dimming light fixtures. TR75 Zio Plus wall module for end-user control of dimming/scene selection. Zone scheduled to hold lighting on during office hours. Lights can be switched on or operate on occupancy sensor after hours. Lighting circuit along windows tied to photo sensor for daylight harvesting. Optional integration with BACnet Building Control System. Individual Offices With Windows GARAGE Integrated: 1-Circuit Lighting Stryker connected to 0-10v dimming light fixtures. Photo sensor to balance natural and artificial light for optimal light level. Occupancy detector to keep lights off when not needed. TR75 Zio Plus wall module for end-user control of dimming/ scene selection. Optional integration with BACnet Building Control System. Parking Garage 5-Circuit Lighting Stryker connected to 0-10v dimming light fixtures. Photo sensor to balance natural and artificial light for optimal light level. Optional integration with BACnet Building Control System. Standalone: Wireless switch with ceilingmounted wireless occupancy sensors and wireless daylight sensor for daylight harvesting.

Easily Add Lighting Control Into A Building Energy Management System Integrate lighting control technology with building automation for installation and operational savings. Lighting stryker and Zio Controllers The Honeywell Lighting Stryker applies proven building automation technology to lighting. The Lighting Stryker sends low-voltage signals to lighting relays and 0-10 volt dimming devices to deliver simple, yet powerful lighting control strategies for energy savings. When used with a TR75 Zio Plus, the Wall Module Configuration Wizard embedded in the Lighting Stryker makes setting up lighting control strategies easy and intuitive. Lighting scenes, switching, smart scheduling, occupancy/ vacancy detection, dimming, daylight harvesting, demand response and task tuning can all be easily configured and adjusted with the TR75 Zio Plus. After configuration, the TR75 serves as a scene selection device for personal lighting control. Installers can set up the system as a standalone lighting control network or integrate to HVAC, security, video and other building automation systems. The Lighting Stryker provides BMS connectivity via BACnet objects for easy integration to WEBs-AX or other leading building automation systems. Lighting Stryker and zio Controllers CLB6438S CLB1433S CLB1311S YCLB6438S TR71 TR75 Lighting Stryker - 5 Circuit (BACnet) Lighting Stryker - 3 Circuit (BACnet) Lighting Stryker - 1 Circuit (BACnet) Y-Pack (Lighting Stryker and TR75 Zio Plus Combo) Zio (Scene Selector) Zio Plus (Configurator/Scene Selector)

Standalone Lighting Controls Offer Easy Savings Honeywell offers traditional wired sensors and switches for standalone applications. Another option is Honeywell s family of standalone wireless sensors that install in as little as 15 minutes and eliminate the need for costly new wiring. These sensors communicate with compatible dimmers, switches and light control systems using reliable Clear Connect TM RF Technology from Lutron. The easily accessible buttons make setup easy and the display illuminates during test mode, helping the installer identify optimal mounting locations. Low-Voltage Sensors for Lighting Control Networks LOSCDT1000RWH ECDIRWH PP120H PP277H Wired Occupancy Sensor - Dual Technology Self-Adaptive 24V With Relay Wired Daylight Sensor - 24V Power Pack (for occupancy/vacancy sensors) 120V Power Pack (for occupancy/vacancy sensors) 277V

Product Overview Standalone Wireless Lighting Controls CLMRF28SDVWH CLMRF26ANSWH CLMRF26ANS277WH CLLRF2VCR2BPWH CLLRF2OCR2BPWH CLLRF2DCRBWH CLRMJCCO124B CLRMJ16RCCO1DVB Wireless Wall Box Light Switch 120-277V No Neutral Wire Required Wireless Wall Box Light Switch 120V Wireless Wall Box Light Switch 277V Wireless Ceiling Mount Vacancy Sensor Wireless PIR Ceiling Mount Occupancy/Vacancy Sensor Wireless Ceiling Mount Daylight Sensor Wireless Power Pack Contact Closure Output Low Voltage 24V Input Wireless Power Pack General Purpose Switch 120V/277V Line Voltage Wall Box Lighting Controls CLMSOPS6MDVWH Wall Box Switch with PIR Occupancy/Vacancy Sensor 120V/277V Dual Voltage for 3A Fan Wallplate CW1WH 1-Gang Wallplate CLMSOP600MWH Wall Box PIR Occupancy/Vacancy Sensor/Switch 120-277V

The Honeywell Difference With the continuing drive to reduce energy consumption in all types of buildings and facilities, choosing Honeywell Lighting Controls can make a substantial contribution toward energy reduction targets. Daylight harvesting, occupancy sensing and extended lamp life combine to lower the cost of your overall lighting solution. In addition, a comprehensive energy management plan incorporating Honeywell, HVAC solutions and building automation products can help you achieve even greater energy efficiencies. Honeywell is a world leader in the design and manufacture of solutions that make buildings more energy efficient and convenient without sacrificing occupant comfort. Drawing on decades of expertise, Honeywell offers a broad portfolio of products and services to support comprehensive energy management plans in buildings around the globe. Lighting represents, on average, more than 20% of a building's total energy consumption.

BACnet registered trademark of American Society of Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE). Lutron and Clear Connect are trademarks of Lutron. Learn More General Inquiries: 800-334-3666 Lighting Technical Hotline: 888-235-7316 HVAC Channel: 888-793-8193 (U.S.) Or 800-565-6282 (CAN) www.customer.honeywell.com Follow us on Twitter: @honeywellcpro YouTube: @honeywellcpro Automation and Control Solutions In the U.S.: Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 www.honeywell.com 67-7609 PR May 2014 2014 Honeywell International Inc.