FEATURES Heavy Industrial CE Approval 10 V/m EMI Protection Reverse Polarity Protection on Input Short Circuit Protection on Output ±0.1% Accuracy ±0.5% Total Error Band Compact Outline -40 C to +125 C Operating Temperature Weatherproof APPLICATIONS Military/Aerospace Test Stands Automotive Test Stands Calibration Equipment High Accuracy Applications Stationary Motor Fuel Control High End Industrial Machinery SPECIFICATIONS Superior Accuracy and Total Error Band Instrument Grade and Compact Variety of Pressure Ports and Electrical Configurations Optional Stainless Steel Snubber CE Compliant and Weatherproof UL Certified Gage, Sealed, Absolute, Compound Expedite Configurations Available (10 Days) The instrument grade U5300 pressure transducers from the UltraStable line of MEAS, with their modular design, offer maximum flexibility for different configurations. This latest series features superior accuracy and total error band for demanding commercial and heavy industrial applications. This series is suitable for measurement of liquid or gas pressure, even for difficult media such as contaminated water, steam, and mildly corrosive fluids. The wetted material is made of 316L stainless steel and the transducer s durability is excellent with no O-rings or organics exposed to the pressure media. The U5300 is weatherproof and exceeds the latest heavy industrial CE requirements including surge protection. The circuit is protected from reverse wiring at input and short circuit at output. This product is geared to the OEM customer for low to mid volumes. MEAS stands ready to provide a custom design of the U5300 where the volume and application warrants. Additional configurations not listed are either available or possible. Please inquire for further information. SENSOR SOLUTIONS ///U5300 07/2018 Page 1
STANDARD RANGES Range (psi) Range (Bar) Gage Sealed Absolute Compound 0 to 015 0 to 001 0 to 030 0 to 002 0 to 050 0 to 3.5 0 to 100 0 to 007 0 to 150 0 to 010 0 to 200 0 to 014 0 to 300 0 to 020 0 to 500 0 to 035 0 to 01k 0 to 070 0 to 03k 0 to 200 0 to 05k 0 to 350 0 to 10k 0 to 700 Intermediate ranges available upon request. PERFORMANCE SPECIFICATIONS Ambient Temperature: 25 C (unless otherwise specified) PARAMETERS MIN TYP MAX UNITS NOTES Accuracy (RSS of linearity, hysteresis, and repeatability) -0.1 0.1 %F.S. BFSL Isolation, Body to any Lead 100 MΩ @500V DC Dielectric Strength 2 ma @500V AC, 1min Pressure Cycles 1.00E+6 0~FS Cycles Proof Pressure 3X 20k psi Rated Burst Pressure 4X 20k psi Rated Long Term Stability (1 year) -0.1 0.1 %F.S. Offset -0.25 0.25 %F.S. @25 C Span -0.25 0.25 %F.S. @25 C Total Error Band -0.5 0.5 %F.S. Over compensated temperature Compensated Temperature -20 +85 C Operating Temperature -40 +125 C Except cable 105 C max Storage Temperature -40 +125 C Except cable 105 C max Load Resistance (R L) R L > 100k Ω Voltage Output < (Supply Voltage -9V) / 0.02A Ω Current Output Current Consumption 5 ma Voltage Output Rise Time (10% to 90%) Pressure Port Material Shock Vibration For custom configurations, consult factory. <2ms (Voltage Output); <3ms (Current Output); Without Snubber 316L Stainless Steel; 316L Stainless Steel Snubber 50g, 11msec Half Sine Shock per MIL-STD-202G, Method 213B, Condition A ±20g, MIL-STD-810C, Procedure 514.2, Fig 514.2-2, Curve L SENSOR SOLUTIONS ///U5300 07/2018 Page 2
Notes Compensated Temperature: The temperature range over which the product will produce an output proportional to pressure within the specified performance limits. Operating Temperature: The temperature range over which the product will produce an output proportional to pressure but may not remain within the specified performance limits. Storage Temperature: The temperature range over which the product can be stored safely in occasions without pressure applied or power input and remains rated performance. Beyond this temperature range may cause permanent damage to the product. All configurations are built with supply voltage reverse and output short-circuit protections. CE Compliance EN 55022 Emissions Class A & B IEC 61000-4-2 Electrostatic Discharge Immunity (8kV contact/15kv air) IEC 61000-4-3 Radiated, Radio-Frequency Electromagnetic Field Immunity (10V/m, 80M-1GHz) IEC 61000-4-4 Electrical Fast Transient Immunity (1kV) IEC 61000-4-5 Surge Immunity (V+ to V-: ±2KV/42Ω; L to Case: ±1KV/12Ω; V- to V 0: ±1KV/42Ω) IEC 61000-4-6 Immunity to Conducted Disturbances Induced by Radio Frequency Fields (150K~80MHz, 10V level for voltage output models, 3V level for current output model) IEC 61000-4-9 Pulse Magnetic Field Immunity (100A/m peak) For all CE compliance tests, max allowed output deviation ±1.5 %F.S. SENSOR SOLUTIONS ///U5300 07/2018 Page 3
DIMENSIONS Note: Refer to installation instructions for recommended torque CODE CONNECTION TYPE DIM A MAX. 1 CABLE 2 FT 2.19 [55.6] E CABLE 3 FT 2.19 [55.6] 2 CABLE 4 FT 2.19 [55.6] 3 CABLE 10 FT 2.19 [55.6] 4 PACKARD CONNECTOR A 2.25 [57.2] 5 BAYONET CONNECTOR 1.94 [49.3] 6 FORM C 1.95 [49.5] 7 FORM A 2.10 [53.3] 9 PACKARD CONNECTOR B 2.25 [57.2] D M12 CONNECTOR 1.95 [49.5] M CABLE 1 M 2.19 [55.6] N CABLE 2 M 2.19 [55.6] P CABLE 5 M 2.19 [55.6] R CABLE 10 M 2.19 [55.6] A AMP CONNECTOR 2.24 [536.9] PRESSURE PORT TYPE CODE PORT DIM B DIM C Typ. 2 1/4-19 BSPP 0.547 [13.9] 0.366 [9.3] 3 G3/8 JIS B2351 0.615 [15.6] 0.366 [9.3] 4 7/16-20UNF MALE SAE J1926-2 STRAIGHT THREAD 0.508 [12.9] 0.366 [9.3] O-RING BUNA-N 90SH ID8.93xW1.83mm 5 1/4-18 NPT 0.600 [15.24] 0.366 [9.3] 6 B E F P N Q S U W G 1/8-27 NPT 0.390 [9.9] 0.366 [9.3] G1/4 JIS B2351 0.547 [13.9] 0.366 [9.3] 1/4-19 BSPT 0.500 [12.7] 0.366 [9.3] 1/4-19 BSPP FEMALE (without snubber) 7/16-20UNF FEMALE SAE J513 STRAIGHT THREAD WITH INTEGRAL VALVE DEPRESSOR 7/16-20UNF FEMALE SAE J513 STRAIGHT THREAD 0.771 [19.58] 0.366 [9.3] 0.647 [17.5] 0.366 [9.3] 0.647 [17.5] 0.366 [9.3] M10 x 1.0 mm ISO 6149-2 0.449 [11.4] 0.366 [9.3] M12 x 1.5 mm ISO 6149-2 0.531 [11.0] 0.366 [9.3] G/14 DIN 3852 FORM E GASKET DIN3869-14 NBR 0.531 [13.5] 0.366 [9.3] M20 x 1.5 mm ISO 6149-2 0.531 [13.5] 0.456 [11.6] M14 x 1.5 mm ISO 6149-2 0.531 [13.5] 0.366 [9.3] SENSOR SOLUTIONS ///U5300 07/2018 Page 4
WIRING Notes: Current Output Wiring CONNECTION +SUPPLY -SUPPLY NC. PINS P REF VENT Bayonet A B C,D,E F Packard, A A B C Packard, B B A C Cable RED BLK In Cable M12 1 3 2,4 AMP/TE 1 2 3 FORM C 1 2 3,4 Threads Through FORM A 1 2 3,4 Threads Through Voltage Output Wiring CONNECTION +SUPPLY +OUTPUT COMMON NC. PINS P REF VENT Bayonet A B C D,E F Packard, A A C B Packard, B B C A Cable RED WHT BLK In Cable M12 1 2 3 4 AMP/TE 1 3 2 FORM C 1 2 3 4 Threads Through FORM A 1 3 2 4 Threads Through 1. NC pins are reserved for factory use only. Customers should not use these connections. 2. For cable connection, the drain wire is internally terminated to pressure port.. SENSOR SOLUTIONS ///U5300 07/2018 Page 5
CONNECTION TYPES CONNECTION DESCRIPTION CONNECTION TYPES MATING HOUSING P/N MATING TERMINAL P/N RUBBER SEAL P/N Bayonet BAYONET PTIH-10-6P OR EQUIV PT06A-10-6S MIL-C-26482 - - Packard 3-PIN METRI-PACK 150 12078090 12103881, QTY 3 - M12 AMP/TE FORM C FORM A BINDER SERIES 713, 09 3431 77 04 OR EQUIV AMP / TE 3-PIN ECONOSEAL J SERIES INDUSTRIAL STANDARD 9.4MM FORM C DIN EN 175 301-803-A 18MM 4-POS FEMALE CONNECTOR - - 174357-2 & 174358-7 HIRSCHMANN 933 024-100,OR, ATAM KD046000B7 (SEAL INCL.) HIRSCHMANN 931 969-100,OR, ATAM KA245000B4 (SEAL INCL.) 171630-1 (AWG 20~24) 171662-1 (AWG 16~20) QTY 3 172746-1 (AWG 20~24) 172888-2 (AWG 16~20) QTY 3 - HIRSCHMANN 730 185-002 - HIRSCHMANN 730 801-002 Note: Transmitter of gage pressure type requires vent to atmosphere on the pressure reference side. This is accomplished via cable from the transmitter (the end of the cable should be terminated to clean and dry area) or through the customer mating connector/cable assembly which has internal vent path. Suggested vented M12 mating connector P/N MB12FWAFF04ST-4 and MB12FWAFF04ST-3 at www.finecables.com for 0.157 ~0.236 and 0.236 ~0.315 diameter cable respectively. WEATHERPROOF WEATHER-PROOF RATING CONNECTION IP CODE Bayonet IP67 Packard IP66 Cable IP67 M12 IP67 AMP/TE IP67 FORM C IP65 FORM A IP65 Note: Weatherproof ratings are met when the mating connectors are installed properly and the cable termination is to dry and clean area. SENSOR SOLUTIONS ///U5300 07/2018 Page 6
OUTPUTS CODE OUTPUT SIGNAL SUPPLY VOLTAGE 3 0.5-4.5V 5 ± 0.25V RATIOMETRIC PROTECTED to 30V 4 1-5V 8-30V 5 4-20mA 9-30V 6 0-5V 8-30V 7 0-10V 12-30V 8 1-6V 8-30V 9 0.5-4.5V 5-30V SENSOR SOLUTIONS ///U5300 07/2018 Page 7
ORDERING INFORMATION U53 3 3 0 0 00 1 5 100P G Output Code Type 3 0.5-4.5V Ratiometric 4 1 5V 5 4-20mA 6 0-5V 7 0-10V 8 1-6V 9 0.5-4.5V Connection Type Code Connection Type 1 Cable, 2 feet E Cable, 3 feet 2 Cable, 4 feet 3 Cable, 10 feet 4 Packard A 5 Bayonet 6 Form C 7 Form A 9 Packard B D M12 M Cable 1m N Cable 2m P Cable 5m R Cable 10m A Amp Shipping 0 Standard H Expedite Snubber 0 No Snubber 1 With Snubber 2 Oxygen Clean B40.1 Level IV Label Type 0 Adhesive Label 1 Laser Marking Selections in blue (expedite) have a 10-business day lead time with a 19-piece maximum order Refer to online installation instruction for recommended torque. Installation instructions are available on our website in English and Chinese. Factory calibration certificate is provided. Pressure Range [psi] psi STD bar STD 015P 001B 030P 002B 050P 3.5B 100P 007B 150P 010B 200P 014B 300P 020B 500P 035B 01KP 070B 03KP 200B 05KP 350B 10KP 700B G S A C G S A C Pressure Type Gauge Sealed Absolute Compound Gauge Sealed (Port 2,5 only) Absolute (Port 2,5 only) Compound Pressure Range between 15psi to 10ksi (1bar to 700bar) are all available. Change Pressure Code Accordingly. Compound pressure range is -14.7 to xxxpsig or -1 to xxxbarg. (e.g. 200PC: -14.7 to 200psig, 020BC: -1 to 20barg) Port Type Selection Code Port Type 2 1/4-19 BSPP 3 G3/8 JIS B2351 7/16-20UNF Male SAE J1926-2 Straight Thread 4 O-Ring BUNA-N 90SH ID8.92xW1.83mm 5 1/4-18 NPT 6 1/8-27 NPT B G1/4 JIS B2351 E 1/4-19 BSPT F 1/4-19 BSPP Female* 7/16-20UNF Female SAE J513 Straight Thread P w/ Integral Valve Depressor N 7/16-20UNF Female SAE J513 Straight Thread Q M10x1.0mm ISO 6149-2 S M12x1.5mm ISO 6149-2 U G1/4 DIN 3852 Form E Gasket DIN3869-14 NBR W M20x1.5mm ISO 6149-2 G M14x1.5mm ISO 6149-2 NORTH AMERICA Measurement Specialties, Inc., a TE Connectivity Company Phone: +1 800-522-6752 Email: customercare.frmt@te.com EUROPE Measurement Specialties (Europe), Ltd., a TE Connectivity Company Phone: +31 73 624 6999 Email: customercare.lcsb@te.com ASIA Measurement Specialties (China), Ltd., a TE Connectivity Company Phone: +86 0400-820-6015 Email: customercare.shzn@te.com TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 2015 TE Connectivity Ltd. family of companies All Rights Reserved. SENSOR SOLUTIONS ///U5300 07/2018 Page 8