CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

Similar documents
CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

INTELLIGENT FIRE ALARM CONTROL PANEL

SFC-200 SERIES LCD FIRE ALARM PANEL

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

NETWORK FIRE ALARM CONTROL PANEL. Features

SFC-200 SERIES LED FIRE ALARM PANEL

Conventional Releasing Control Panel

SFC-500 SERIES FIRE ALARM PANEL

CATALOG NUMBER. Features. Description

FA-300 Series. LED Fire Alarm Control Panel. User Guide. FA-300 SERIES Fire Alarm Control Panel. FA-300 SERIES Fire Alarm Control Panel

FX Intelligent Analog Fire Alarm Control Panel. Installation and Operation Manual

LifeAlarm Fire Alarm Control Panels

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

good things in small packages

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

MR-2602 Two Zone Fire Alarm Control Panel

SELECT-A-HORN/STROBE SERIES

FA-1000 SERIES. Microprocessor-Based Fire Alarm Control Panel. Installation and Operation Manual

Specification/ Data Sheet

INSTALLATION & OPERATION GUIDE

FA-300 Series. LCD Fire Alarm Control Panel. Installation and Operation Manual

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

FX-350 Series. Analog/Addressable Fire Alarm Panels. Installation and Operation Manual FX-350 SERIES. LT-959 Rev. 3.1 March 2012 FX-350 SERIES

FX-350 Series. Analog/Addressable Fire Alarm Panels. Installation and Operation Manual

FireNET Plus Wiring Instructions

Addressable Fire Alarm Control Panel

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Conventional Fire Alarm Systems

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

MPC-6000 / MPC-7000 / RND-2

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

AL800ULADA. NAC Power Extender. Installation Guide

PEGAsys. Multi-Loop Intelligent Suppression Control System FEATURES DESCRIPTION. Effective: March 2007 K

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

AND ARCHITECT SPECIFICATIONS

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

DS7400Xi Addressable Control/ Communicator

TECHNICAL DATA OBSOLETE

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX TM Series Intelligent Fire Alarm & Network System

MR-2350/2351. Fire Alarm Control Panels. Installation and Operation Manual

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual

Commercial and Light Industrial Fire Alarm Control Panel

AND ARCHITECT SPECIFICATIONS

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

30.45 Electric Release PDRP-2001

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

Intelligent Security & Fire Ltd

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Agent Release Control Panel

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

PFC-4064 Conventional Fire Alarm Panel

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

Release Control Fire Alarm Systems

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

HCA Series Conventional Fire Alarm System (HCA-2, HCA-2D, HCA-4, HCA-4D, HCA-8, HCA-8D) Installation and Operation Manual

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

FX Fire Alarm Control Panel. Installation and Operation Manual

Excel-EN Conventional Fire Control Panel

June 10, 2002 DF C S2424

RAX-LCD-LITE. Remote Annunciator. Installation and Operation Manual

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

D7024 Fire Alarm Control Panel

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

HCA Series Conventional Fire Alarm System (HCA-2, HCA-2D, HCA-4, HCA-4D, HCA-8, HCA-8D) Installation and Operation Manual

AL600ULADA. NAC Power Extender. Installation Guide

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

FX-3500RCU. Fire Alarm Control Panel. Installation and Operation Manual

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111

Installation, Operating and Maintenance Manual

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

July 14, 1999 DF C-100.

ECC-50/100C. Emergency Command Center

FMR Installation Instructions. Addressable Fire System Controller

LifeAlarm Fire Alarm Controls

EVO192 v3.0 Fire and Burglary What s New

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

Multi-Application Peripherals and Accessories

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

Control/Communicator 5110XM. Installation Instructions Installation Instructions Installation Instructions N8026 4/96

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

Transcription:

CONVENTIONAL FIRE ALARM CONTROL PANELS SFC-200 Series Fire Alarm Control Panels Description Summit s SFC-200 Series fire alarm control panels consist of six and twelve zone models which are equipped with a two line by 20 character back-lit LCD display, numerical keypad and an integrated UDACT/Digital Communicator. The SFC-200 Series family also includes a six and twelve zone models equipped with an LED display and an integrated UDACT/Digital Communicator. In addition the SFC-200 Series family includes remote LCD annunciators, LED annunciators and remote smart relay modules. The SFC-200 Series panels are ideal for both new and retrofit applications. Designed for small to medium commercial, institutional and industrial occupancies, these panels are powerful enough to meet today s installation demands. The SFC-200 Series panels are configurable by the keypad for onsite programming or by a PC for both onsite and remote programming. Easy to install and simple to operate and configure, the SFC-200 Series panels enable the installer to configure the system to meet their specific requirements. The SFC-200 Series panels are equipped with a 5 Amp power supply, 4-wire resettable smoke power supply (300mA max.), an interface for a Remote Trouble Indicator (SRTI-200) and an RS-485 interface for remote LCD annunciators, LED annunciators and Remote Smart Relay modules. All SFC-200 Series panels come complete with a red door, black enclosure, durable CAT-30 lock and key and space to mount up to 12 AH batteries. Optional trim rings are available for semi-flush mounting. Features Listed to UL 864, 9th edition Available in six and twelve zone models Available in LED and LCD Display configurations LCD Display versions are equipped with a 2 line by 20 character back-lit LCD display and numerical keypad Integrated UDACT/Digital Communicator on select models Front panel and PC programmable LED Display versions are front panel (using CFG-300 configuration tool) and PC programmable Remote upload/download capabilities Base panel is equipped with Class B (Style B ) initiating circuits which may be configured as Class A (Style D ) using a Class A converter module Initiating circuits may be configured as Alarm, Verified Alarm, Waterflow Alarm, Sprinkler Alarm, Latching or Non-Latching Supervisory, Monitor and Trouble-Only Base panel is equipped with Class B (Style Y ) indicating circuits which may be configured as Class A (Style Z ) using a Class A signal converter module Audible signals may be configured for Steady, Temporal Code, California Code and March Time Indicating Circuits may be configured as Silenceable or Non-Silenceable for both signals and strobes Built-in sync protocols for the following strobe manufacturers: Mircom, Amseco, System Sensor, Gentex, Faraday and Wheelock Relay contacts for Common Alarm, Auxiliary/Alarm (Disconnectable), Common Supervisory and Common Trouble Configurable Signal Silence Inhibit, Auto Signal Silence and One-Man Walk Test Subsequent Alarm, Supervisory, and Trouble operation RS-485 Interface for Remote LED Annunciators, LCD Annunciators and Remote Smart Relay Modules Two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events 5 Amp Power Supply Optional modules for additional internal relay circuits and City Tie/Polarity Reversal Optional trim rings for semi-flush mounting MEA approved S24005 S24005 7165-1665:101 (LED Models) 7165-1665:114 71-08-E Issue 1 SUMMIT SYSTEMS TECHNOLOGIES Page 1 of 6 Canada 25 Interchange Way, Vaughan (Toronto), Ontario L4K 5W3 Telephone: (905) 695-3549 Fax: (905) 660-4113 Web Page: www.summit-st.net U.S.A. 4575 Witmer Industrial Estates, Niagara Falls, NY 14305 Telephone: (866) 786-6480 Fax: (888) 660-4113 E-mail: mail@summit-st.net

Features Initiating Circuits The SFC-200 Series panels are equipped with Class B (Style B ) initiating circuits with individual disconnect buttons. The initiating circuits may be configured as Class A (Style D ) using an SICA-206 Class A converter adder module. Each initiating circuit has two LEDs; one dual colour (Red/Amber) for Alarm and Supervisory and one Trouble LED (Amber). Each initiating circuit may be configured for one of the following modes of operation: Alarm (Without smoke detector verification) Verified Alarm (With smoke detector verification) Waterflow Alarm (Water flow sensors) Sprinkler Alarm (Sprinkler flow sensors) Latching Supervisory Non-Latching Supervisory Monitor (non-latching input used mainly for correlating to a relay circuit) Trouble-Only (for monitoring a trouble condition from an external device) Indicating Circuits The SFC-200 Series panels are equipped with equipped with Class B (Style B ) indicating circuits with individual disconnect buttons. The indicating circuits may be configured as Class A (Style Z ) using an SOCA-204 or SOCA-202 Class A signal converter adder module. Each indicating circuits has an individual trouble LED (Amber). The audible signals may be configured for Steady, Temporal Code, California Code and March Time. Each of the indicating circuits may be configured for one of the following modes of operation: Silenceable Signal Non-Silenceable Signal Silenceable Strobe Non-Sileneceable Strobe The SFC-200 has built-in sync protocols for the following strobe manufacturers; Summit, Amseco, System Sensor, Gentex, Faraday and Wheelock. i3 Series Protocol The SFC-200 Series panels have the i3 Series protocol built-in. The panels support the two-wire i3 Series smoke detectors (2W-B/2WT-B). These i3 series detectors communicate with the SFC-200 to provide the following status information: Open circuit trouble This trouble indicates that loop is broken. Communication trouble This trouble indicates that there is a fault in the line or the line is too noisy, the panel cannot communicate with the devices. Dirty device The devices on the i3 zone are dirty. Out of sensitivity The devices on the i3 zone is out of sensitivity and cannot detect an alarm condition. Freeze trouble The device has detected a freeze condition, e.g. the temperature is below 41 F / 5 C (available only on model 2WT-B)) The built-in protocol removes the need for the 2W-MOD Maintenance Module. UDACT/Digital Communicator Select SFC-200 Series panels are equipped with a fully integrated UDACT/Digital Communicator which allows for the reporting of events to a monitoring facility. The UDACT/Digital Communicator can be configured for single or dual line operation and uses the Security Industry Association (SIA) and Ademco Contact ID protocols. The UDACT/Digital Communicator is configured via the main display and keypad on the main panel. In addition to its reporting functions, the integrated UDACT/Digital Communicator can be used to connect to the SFC-200 panel from remote computers for uploading and downloading of configuration data. It also allows for the viewing of the event history logs. The SFC-200 series panels have two event history logs comprised of a 200 event alarm log for alarm related events and a 200 event general log for all other events. The integrated UDACT/Digital Communicator can be configured for either DACT or UDACT operation. In DACT mode the Digital Communicator reports common alarm, trouble and supervisory information. In UDACT mode the Digital Communicator reports point specific information. Page 2 of 6 SUMMIT SYSTEMS TECHNOLOGIES Issue 1

SFC-200 Series LCD Version Models SFC-200 Series LED Version Models SFC-200-6DR / SFC-200-6DDR Six Zone LCD Display Fire Alarm Control Panels The SFC-200-6DR and SFC-200-6DDR are equipped with six Class B (Style B ) initiating circuits and two Class B (Style Y ) indicating circuits rated @ 1.7 Amps maximum. (Total of 5 Amps) The SFC-200-6DDR is equipped with a built-in UDACT/Digital Communicator. One SICA-206 Six Initiating Circuit Class A Converter Modules may be used for Class A (Style D ) wiring of the initiating circuits. One SOCA-202 Two Indicating Circuit Class A Converter Module may be used for Class A (Style Z ) wiring of the indicating circuits. The cabinet will support up to 12 AH batteries. The panels can be semi-flush mounted with the optional SFC-200TRB trim ring. Note: Not ULC listed. SFC-200-6DR: 20 H x 14.5 W x 4.5 D SFC-200-6DDR: 20 H x 14.5 W x 4.5 D SFC-200TRB: 22.5 H x 17 W SFC-200-6LR / SFC-200-6LDR Six Zone LED Display Fire Alarm Control Panels The SFC-200-6LR and SFC-200-6LDR are equipped with six Class B (Style B ) initiating circuits and two Class B (Style Y ) indicating circuits rated @ 1.7 Amps maximum. (Total of 5 Amps) The SFC-200-6LDR is equipped with a built-in UDACT/Digital Communicator. One SICA-206 Six Initiating Circuit Class A Converter Modules may be used for Class A (Style D ) wiring of the initiating circuits. One SOCA-202 Two Indicating Circuit Class A Converter Module may be used for Class A (Style Z ) wiring of the indicating circuits. The cabinet will support up to 12 AH batteries. The panels can be semi-flush mounted with the optional SFC-200TRB trim ring. SFC-200-6LR: 20 H x 14.5 W x 4.5 D SFC-200-6LDR: 20 H x 14.5 W x 4.5 D SFC-200TRB: 22.5 H x 17 W SFC-201-12DDR Twelve Zone LCD Display Fire Alarm Control Panel with UDACT/Digital Communicator The SFC-201-12DDR is equipped with twelve Class B (Style B ) initiating circuits and four Class B (Style Y ) indicating circuits @ 1.7 Amps maximum. (Total of 5 Amps). One SICA-206 Six Initiating Circuit Class A Converter Module may be used for Class A (Style D ) wiring of the initiating circuits. One SOCA-204 Four Indicating Circuit Class A Converter Module may be used for Class A (Style Z ) wiring of the Indicating circuits. The SFC-201-12DDR has a built-in UDACT/Digital Communicator and the cabinet will support up to 12 AH batteries. The panel can be semi-flush mounted with the optional SFC-UNIV- TRB trim ring. Note: Not ULC listed. SFC-201-12DDR: 26 H x 14.5 W x 4.5 D SFC-UNIV-TRB: 28.5 H x 17 W SFC-201-12LDR Twelve Zone LED Display Fire Alarm Control Panel with UDACT/Digital Communicator The SFC-201-12LDR is equipped with twelve Class B (Style B ) initiating circuits and four Class B (Style Y ) indicating circuits rated @ 1.7 Amps maximum. (Total of 5 Amps) Two SICA-206 Six Initiating Circuit Class A Converter Modules may be used for Class A (Style D ) wiring of the initiating circuits. One SOCA-204 Four Indicating Circuit Class A Converter Module may be used for Class A (Style Z ) wiring of the indicating circuits. The SFC-201-12LDR has a built-in UDACT/Digital Communicator and the cabinet will support up to 12 AH batteries. The panel can be semi-flush mounted with the optional SFC-UNIV-TRB trim ring. SFC-201-12LDR: 26 H x 14.5 W x 4.5 D SFC-UNIV-TRB: 28.5 H x 17 W Issue 1 SUMMIT SYSTEMS TECHNOLOGIES Page 3 of 6

Remote Annunciators SRAM-200LCDR Remote LCD Annunciator The SRAM-200LCDR provides remote LCD annunciation through a two line by 20 character LCD display. The SRAM-200LCDR provides control switches for System Reset, Signal Silence, Fire Drill and Acknowledge as well as a numeric keypad to access the menu functions. The common control functions can be disabled on a per function basis. The SRAM-200LCDR has LED indicators for A.C. On, Alarm, Supervisory, Trouble and CPU Fail. The SRAM-200LCDR is available in a red enclosure and comes complete with and a CAT-30 lock and key. Note: ULC Listed as an Ancillary Device. SRAM-208R/SRAM-216R Remote LED Annunciators The SRAM-208R and SRAM-216R provide 8 or 16 points respectively of LED annunciation. Both models feature bi-coloured LEDs which are configurable for either Alarm (red) or Supervisory (amber). The LED annunciators have indicators for A.C. On, Common Trouble and Signal Silence and control switches for System Reset, Signal Silence, Lamp Test and Buzzer Silence. The SRAM-208R and SRAM-216R are equipped with a keyswitch which allows for enabling and disabling of the Common Control functions. Both models are available in a red finish and mount in a 4-gang electrical box. Note: ULC Listed as an Ancillary Device. SSR-212R Smart Relay Module The SSR-212R provides twelve Form C configurable relay circuits, rated @ 28 VDC, 1 amp (resistive). Each circuit can be configured as a Normally Open (N.O.) or Normally Closed (N.C.) contact. Each relay is equipped with an LED that is lit when the relay is energized. The relays can be configured as relay per zone (1 to 1), Common on Alarm, Common on Supervisory or programmable for a logical or adjacent zone configuration. An adjacent zone configuration will turn on an adjacent zone when the configured zone is active. A chaining configuration allows for multiple relays to turn on. The SSR-212R is DIP switch configurable and connects to the RS-485 bus. The SSR-212R come complete with a red enclosure and a CAT-30 lock and key. SRAM-316 Remote LED Annunciator The SRAM-316 Remote LED Annunciator provides 16 points of LED annunciation. The SRAM-316 comes standard with bi-coloured LEDs which are automatically configured for either Alarm (Red) or Supervisory (Amber). The SRAM-316 has indicators for A.C. On, Common Trouble and Signal Silence and controls for System Reset, Lamp Test, Fire Drill, Buzzer Silence and Signal Silence. In addition it allows for the control switches to be disabled on a per function basis. In addition the SRAM-316 provides individual trouble LEDs. The SRAM-316 mounts in a SBB-301R enclosure. SRTI-200 Remote Trouble Indicator Summit s Remote Trouble Indicator provides remote annunciation of fire alarm troubles. The SRTI-200 mounts onto a standard single gang electrical box. Page 4 of 6 SUMMIT SYSTEMS TECHNOLOGIES Issue 1

Adder Modules SICA-206 Six Initiating Circuit Class A Converter Module The SICA-206 converts six Class B (Style B initiating circuits on the SFC-200 main board to Class A (Style D ) circuits. The SICA-206 is equipped with wire leads to connect to the SFC-200 main board. It mounts to the right of the main board Class B (Style B ) initiating circuits. Two SICA-206 modules are required to convert all twelve initiating circuits on an SFC-201-12 series panel. SRM-206/SRM-212 Relay Circuit Adder Modules The SRM-206 provides six Form C configurable relay circuits, rated @ 28 VDC, 1 amp (resistive). The SRM-212 provides twelve Form C configurable relay circuits, rated @ 28 VDC, 1 amp (resistive). On both models each circuit can be configured as a Normally Open (N.O.) or Normally Closed (N.C.) contact. Each relay is equipped with an LED that is lit when the relay is energized. The relays can be configured as relay per zone (1 to 1), Common on Alarm, Common on Supervisory or programmable for logical or adjacent zone configuration. An adjacent zone configuration will turn on adjacent zone when configured zone is active. A chaining configuration allows for multiple relays to turn on. SOCA-204 Four Indicating Circuit Class A Converter Module The SOCA-204 converts four Class B (Style Y ) indicating circuits on the SFC-200 main board to Class A (Style Z ) circuits. The SOCA-204 is equipped with wire leads to connect to the SFC-200 main board. It mounts to the right of the main board Class B (Style Y ) indicating circuits and is used with the SFC-201-12 series panels. SPR-200 Polarity Reversal/City Tie Module The SPR-200 provides outputs for city box and polarity reversal applications. As a city tie module the SPR-200 provides an interface between the control panel indicating circuits and a master box. It provides off-premises signal transmission for systems that must comply with NFPA requirements for Auxiliary Protective Systems. As a polarity reversal module the SPR-200 provides an interface between the control panel and a reverse polarity receiver. It provides off-premises signal transmission for systems that must comply with NFPA requirements. SOCA-202 Two Indicating Circuit Class A Converter Module The SOCA-202 converts two Class B (Style Y ) indicating circuits on the SFC-200 main board to Class A (Style Z ) circuits. The SOCA-202 is equipped with wire leads to connect to the SFC-200 main board. It mounts to the right of the main board Class B (Style Y ) indicating circuits and is used with the SFC-200-6 series panels. SELR-200 Active End-of-Line Resistors The SELR-200 are power saving End-of-Line resistors which eliminates the need for an additional battery cabinet or larger batteries in order to meet the 60 hour standby requirement. (Please refer to Battery Calculation Chart in manual for more details.) The SELR-200 can also be used when larger batteries than can fit in the cabinet are required. The SELR-200 are available with or without a mounting plate. Issue 1 SUMMIT SYSTEMS TECHNOLOGIES Page 5 of 6

CFG-300 Configuration Tool The CFG-300 Configuration Tool is required for onsite front panel programming of the SFC-200 Series LED version panels. The CFG-300 plugs into the SFC-200 main board to provide a two line by 20 character LCD display. The SFC-200 Series LED version panels are configured using the CFG-300 and push buttons on the main board. In configuration mode, the initiating and indicating circuit disconnect buttons act as function keys. Removing the zone labels reveals the programming function buttons. The CFG-300 tool is used for configuration purposes only and not for normal operation. Ordering Information Specifications AC Input 120VAC @ 60Hz Standby Power 24VDC standby batteries Charging Capability 4 to 12 AH Current Consumption Standby 283mA Alarm 560mA Indicating Circuits Power limited / 24VDC unfiltered / 1.7A @ 49 C per circuit. Maximum 5 Amps. Aux supply (non resetable) Power limited / 22.3VDC regulated / 500mA max 4-wire smoke supply (resetable) Power limited/22.3vdc regulated / 300mA max Unfiltered supply (full wave rectified) Power limited / 24VDC unfiltered / 1.7A max at 49 C Auxiliary Relays (Common alarm/supv/trb/ and auxiliary second alarm) FormC / 28VDC / 1A max Model Number Description Control Panels SFC-200-6DR* Six Zone LCD Display Fire Alarm Control Panel SFC-200-6DDR* Six Zone LCD Display Fire Alarm Control Panel with built-in UDACT/Digital Communicator SFC-201-12DDR* Twelve Zone LCD Display Fire Alarm Control Panel with built-in UDACT/Digital Communicator SFC-200-6LR Six Zone LED Display Fire Alarm Control Panel SFC-200-6LDR Six Zone LED Display Fire Alarm Control Panel with built-in UDACT/Digital Communicator SFC-201-12LDR Twelve-Zone LED Display Fire Alarm Control Panel with UDACT/Digital Communicator Remote Annunciators and Modules SRAM-200LCDR Remote LCD Annunciator (Note: ULC Listed as an Ancillary Device.) SRAM-208R Eight zone Remote LED Annunciator (Note: ULC Listed as an Ancillary Device.) SRAM-216R Sixteen zone Remote LED Annunciator (Note: ULC Listed as an Ancillary Device.) SRAM-316 Sixteen zone Remote LED Annunciator SSR-212R Remote Relay Module SRTI-200 Remote Trouble Indicator SBB-301R Red Semi-Flush Enclosure for SRAM-316 SBB-301WPR Red Semi-Flush Weatherproof Enclosure for SRAM-316 TH-101 Heater Kit for use with SBB-301WPR Adder Modules SICA-206 Six Initiating Circuit Class A Converter Module SOCA-204 Four Indicating Circuit Class A Converter Module SOCA-202 Two Indicating Circuit Class A Converter Module SRM-206 Six Relay Circuit Adder Module SRM-212 Twelve Relay Circuit Adder Module SPR-200 Polarity Reversal/City Tie Module SELR-200 Active End-of-Line Resistor Accessories CFG-300 Configuration Tool for SFC-201-12LDR SFC-200TRB Black Semi-Flush Trim Ring for SFC-200-6 enclosures SFC-UNIV-TRB Black Universal Semi-Flush Trim Ring for SFC-201-12 enclosures UIMA Universal Programming Tool SFC-200-DF Dead Front for SFC-200-6DR/SFC-200-6DDR SFC-201-DF Dead Front for SFC-201-12DDR * Not ULC Listed Page 6 of 6 SUMMIT SYSTEMS TECHNOLOGIES Issue 1 Summit reserves the right to make changes at any time without notice in prices, colors, materials, components, equipment, specifications and models and also to discontinue models. ISO 9001:2000 REGISTERED