The complete conventional fire warning system

Similar documents
Addressable and Conventional Fire Protection

EFBW series - BiWire Ultra control panel

Conventional Fire Detection

System 800 Addressable Fire Detection & Alarm System

Xenex Conventional Fire Detection & Alarm System

Installation, Operating and Maintenance Manual

Excel-EN Conventional Fire Control Panel

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Conventional Fire Alarm System 2014 V1.2

OPERATION AND INSTALLATION MANUAL

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

End To End Optical Beam Smoke Detector. Additional Information

INPUT / OUTPUT MINI MODULES

ELECTRONIC SOUNDER STROBE Model : AVD-C407

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Intelligent Security & Fire Ltd

CONTENTS NBM-06 Bell (6") Page 1

4 wire conventional alarm system

Emergi-Lite Orbis detectors

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Precept Marine Control Panel Application Guide

Intelligent addressable fire alarm control panel

Opal TM AV Devices. Data Sheet. Benefits

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

July 14, 1999 DF C-100.

intelligent solutions

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

An introduction to... Sigma

Analogue addressable devices

Fire Signalling. Signalling Solutions

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

The EN54 Part 2 and 4 Fire System

Fire Product Catalog

Industries. As a premier global manufacturing company, we believe that great brands are

Sita200plus. 200detectors. Single loop analogue addressable System

30.45 Electric Release PDRP-2001

2018 Johnson Controls. Tyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, Switzerland DUO-CEL

Carbon Monoxide (CO) detection system

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

good things in small packages

MINERVA MZX125 Digital Addressable Fire Detection System

Reflective Optical Beam Smoke Detector User Guide

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Commercial and Light Industrial Fire Alarm Control Panel

Saxon Range 1-8 Zone Convertional Control Panels

Fire Signalling. Signalling Solutions

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

LEAKSTOPPER 1 Single zone water leak detection system

AND ARCHITECT SPECIFICATIONS

Solution F2. Fire Alarm Control Panels one step ahead.

Wireless Fire Solutions

FEC400 Series. Installation Manual

Conventional Fire Alarm System Product Range Guide

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Conventional Leaflets

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Conventional systems Product Name

ACP10 & ACP50 Security Systems

Eaton is a global leader with expertise in:

Evolution Analogue Addressable Fire System

2019 Fire Alarm Systems Product catalogue

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

ECC-50/100C. Emergency Command Center

LEAKSTOPPER RANGE Multizone water leak detection systems

2017 Fire Alarm Systems Product catalogue

CODESEC FIRE ALARM SYSTEMS. security technologies

MINERVA MX. 800 Series Ancillary Equipment

PSN-1000 & PSN 1000(E) Installation Manual

Touch Screen 1 loop Addressable Fire Alarm Panel

MINERVA MZX125. Digital Addressable Fire Detection System

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Control Panel Engineering and Commissioning Instructions

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

Addressable Fire Alarm Control Panel

The new detector from Rafiki

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Fire Alarm System. The Intelligent Solution. Leading global technology Safe guarding lives and properties

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

9822 Marine Fire and Detection Equipment. Cerberus PRO. Cerberus PRO. Marine Fire and Detection Equipment. Models FH-2071-UM, BP-62 and USCG-HPLATE

Conventional Smoke Detectors KFAPO

TECHNICAL DATA OBSOLETE

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

IGD.CO.UK

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

LF-4000 Series Conventional Fire Alarm Control Unit

Application, Installation, Operation & Maintenance Manual

2013 Fire Alarm Systems Product catalogue

Opal TM AV Devices. Data Sheet. Benefits

Fire Signalling. Signalling Solutions

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Intelligent Addressable Fire Alarm System

Transcription:

The complete conventional fire warning system www.espuk.com

MAG2P 2 Zone Fire Panel 2 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call points per zone Integral evacuate alarm button Class change facility Enable/disable security key One man walk test facility Volt free fire change over relay Volt free fault change over relay Individual sounder circuit fault ID Individual zone/sounder isolate BS5839 and EN54 P2/4 compliant CE certified Requires only 1x12v battery ABS casing INPUTS Max detectors per zone 30 Thresholds for zone conditions 0-2 ma (Fault condition) 2-6 ma (Normal condition) 6-110 ma (Fire condition) 110 ma - Short (Fault condition) POWER Mains fail consumption 50mA Mains supply 230 VAC ± 10% Standby supply 1 x 7ah 12V S.L.A. Battery Power availability 0.7 amps OUTPUTS Sounder 1 24V (max 300mA fused) Sounder 2 Fault/fire relay Auxiliary output ENVIRONMENT Working Temperature 0 to 40 O C Storage Temperature 24V (max 300mA fused) Volt free 500mA @ 24V (max load) 24VDC (300mA fused) -20 to 60 O C Humidity 0-95% Dimensions (mm) Weight 340W 290H 100D 2.1 KG

MAG2 2 Zone Fire Panel INPUTS Max detectors per zone 30 Thresholds for zone conditions 0-2 ma (Fault condition) 2-6 ma (Normal condition) 6-110 ma (Fire condition) 110 ma - Short (Fault condition) POWER Mains fail consumption 50mA Mains supply 230 VAC ± 10% Standby supply 1 x 7ah 12V S.L.A. Battery Power availability 0.7 amps OUTPUTS Sounder 1 24V (max 300mA fused) Sounder 2 Fault/fire relay Auxiliary output ENVIRONMENT Working Temperature 0 to 40 O C Storage Temperature 24V (max 300mA fused) Volt free 500mA @ 24V (max load) 24VDC (300mA fused) -20 to 60 O C Humidity 0-95% Dimensions (mm) Weight 200W 290H 80D 2.7 KG 2 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call points per zone Integral evacuate alarm button Class change facility Enable/disable security key One man walk test facility Volt free fire change over relay Volt free fault change over relay Individual sounder circuit fault ID Individual zone/sounder isolate BS5839 and EN54 P2/4 compliant CE certified Requires only 1x12v battery Metal casing

MAG4P 4 Zone Fire Panel 4 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call points per zone Integral evacuate alarm button Class change facility Enable/disable security key One man walk test facility Volt free fire change over relay Volt free fault change over relay Individual sounder circuit fault ID Individual zone/sounder isolate BS5839 and EN54 P2/4 compliant CE certified Requires only 1x12v battery ABS casing INPUTS Max detectors per zone 30 Thresholds for zone conditions 0-2 ma (Fault condition) 2-6 ma (Normal condition) 6-110 ma (Fire condition) 110 ma - Short (Fault condition) POWER Mains fail consumption 50mA Mains supply 230 VAC ± 10% Standby supply 1 x 7ah 12V S.L.A. Battery Power availability 0.7 amps OUTPUTS Sounder 1 24V (max 300mA fused) Sounder 2 Fault/fire relay Auxiliary output ENVIRONMENT Working Temperature 0 to 40 O C Storage Temperature 24V (max 300mA fused) Volt free 500mA @ 24V (max load) 24VDC (300mA fused) -20 to 60 O C Humidity 0-95% Dimensions (mm) Weight 340W 290H 100D 2.5 KG

MAG4 4 Zone Fire Panel INPUTS Max detectors per zone 30 Thresholds for zone conditions 0-2 ma (Fault condition) 2-6 ma (Normal condition) 6-110 ma (Fire condition) 110 ma - Short (Fault condition) POWER Mains fail consumption 50mA Mains supply 230 VAC ± 10% Standby supply 1 x 7ah 12V S.L.A. Battery Power availability 0.7 amps OUTPUTS Sounder 1 24V (max 300mA fused) Sounder 2 Fault/fire relay Auxiliary output ENVIRONMENT Working Temperature 0 to 40 O C Storage Temperature 24V (max 300mA fused) Volt free 500mA @ 24V (max load) 24VDC (300mA fused) -20 to 60 O C Humidity 0-95% Dimensions (mm) Weight 320W 220H 80D 3.5 KG 4 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call points per zone Integral evacuate alarm button Class change facility Enable/disable security key One man walk test facility Volt free fire change over relay Volt free fault change over relay Individual sounder circuit fault ID Individual zone/sounder isolate BS5839 and EN54 P2/4 compliant CE certified Requires only 1x12v battery Metal casing

MAG816 8 Zone Fire Panel expandable to 16 zones Up to 16 programmable zones Up to 16 sounder circuits Active end of line monitoring and head removal Up to 32 fire detectors per zone Unlimited number of call points per zone Integral evacuate alarm button Repeater facility Class change facility Enable/disable security key One man walk test facility Volt free fire change over relay Volt free fault change over relay Individual sounder circuit fault ID Individual zone/sounder isolate Alarm delay options BS5839 and EN54 P2/4 compliant CE certified Requires 1 x 12V batteries ABS casing INPUTS Max. detectors per zone 32 Thresholds for zone conditions 0-2 ma (Fault condition) 2-10 ma (Normal condition) 10-110 ma (Fire condition) 110mA - + Short (Fault condition) POWER Mains fail consumption 130mA (1 zone expander) 260mA (4 zone expanders) Mains supply 230 VAC ± 10% Standby supply 1 x 18ah 12V S.L.A. Batteries Power availability 0.7 amps OUTPUTS On board sounder circuits (4) 300mA @ 24V fuse resettable (PTC) Sounder expander cards (4) Fault/fire relay Auxiliary output ENVIRONMENT Working Temperature 0 to 40 O C Storage Temperature 150mA @ 24V fuse resettable (PTC) Volt free 500mA @ 24V (max load) 24VDC (300mA fused) -20 to 60 O C Humidity 0 to 93% Dimensions (mm) Weight 456W 350H 125D 4.2 KG FIRE ZONE / SOUNDER OUTPUT MATRIX Number of Number of Number Number of zone cards sounder cards of zones sounder fitted fitted outputs 2 0 8 4 3 0 12 4 4 0 16 4 2 1 8 8 3 1 12 8 1 2 4 12 2 2 8 12 1 3 4 16 NB The MAG816 features 4 sounder circuits. Space is provided for up to 4 extra expansion cards of any combination. Sounder cards carry 4 sounder circuits, Zone cards carry 4 fire zones. The MAG816 is supplied as standard with 8 fire zones and 4 sounder circuits.

NB Panel shown fitted with 4 sounder and 8 zones

DETECTORS Multi view twin leds Low profile aesthetic housing The new range of Fireline detectors have been developed to provide a perfect compliment to the Fireline Mag panels. All detectors are supplied with a diode base, and conform to the latest EN54 standards. Their smooth aesthetics and competitive pricing will make them more than suitable for the majority of conventional installations. Built in 470ohm/680ohm resistor Head to base locking facility Fitting alignment marks Self cleaning contact points Back box fixing facility Clear contact identification Convenient wiring space Built in schottky diode PSD-2 Optical smoke detector CSD-2 Combined optical smoke & rate of rise heat detector FHD-2 Fixed temperature heat detector RHD-2 Rate of rise heat detector MODEL PSD-2 CSD-2 FHD-2 RHD-2 DESCRIPTION Optical smoke Combined smoke/heat Fixed temp heat Rate of rise heat TYPE Conventional Conventional Conventional Conventional APPROVAL EN54-7 EN54-7, EN54-5 EN54-5 EN54-5 CLASS N/A A1R A2S A1R OPERATING VOLTAGE 9-30VDC 9-30VDC 9-30VDC 9-30VDC STANDBY CURRENT @ 24V < 60μA < 60μA < 60μA < 60μA ALARM CURRENT @ 24V 49mA 49mA 49mA 49mA WIRE GAUGE 0.4mm - 2.0mm TWIN 0.4mm - 2.0mm TWIN 0.4mm - 2.0mm TWIN 0.4mm - 2.0mm TWIN OPERATING TEMPERATURE -10 C to 60 C -10 C to 60 C -10 C to 60 C -10 C to 60 C TEST FACILITY Simulated Smoke Simulated Smoke Heat Source Heat Source

WARNING DEVICES BA-1R RED BANSHEE SOUNDER BA-1W WHITE BANSHEE SOUNDER BS-1R RED BEDROOM SOUNDER BS-1W WHITE BEDROOM SOUNDER MA-1 MULTI ALERT SOUNDER TR-1 TRI-TONE SOUNDER DBS-1 DETECTOR BASE SOUNDER MODEL BA-1R/BA-1W BS-1R/BS-1W DBS-1 MA-1 TR-1 DESCRIPTION Banshee sounder Bedroom sounder Detector base sounder Multi alert sounder Tri-tone sounder SOUND OUTPUT @ 1M 87-112 dba 90 dba 93 dba 103 dba 90 dba CURRENT 6-30 ma 7 ma 18 ma 15 ma 5mA IP RATING IP45 N/A N/A IP55 IP21C

SOUNDER STROBES IFB-1 6 INTERNAL FIRE BELL WFB-1 8 WEATHERPROOF FIRE BELL FS-1 1 WATT STROBE FS-2 2 WATT STROBE FS-3 3 WATT STROBE ZRL2 REMOTE LED INDICATOR PLATE CB-1 COMBINED BANSHEE SOUNDER + STROBE CB-3 TRI-TONE SOUNDER STROBE MODEL IFB-1 WFB-1 FS-1/2/3 ZRL2 CB-1 CB-3 SOUND OUTPUT 95 dba 95 dba N/A N/A 87-112 dba 90 dba FLASH RATE N/A N/A 60 / minute permanent 60 / minute 60 / minute CURRENT 11 ma 25 ma 42, 84, 126 ma minimal 40 ma + sounder 15mA IP RATING IP55* (TBC) IP55* (TBC) IP65 internal use only IP45 IP21C CALL POINTS SCP-2 SURFACING MOUNTING CALL POINT Spare glasses available in packs of 10 (SCPG2) Spare keys available (SCPK2) FCP-2 FLUSH MOUNTING CALL POINT Spare glasses available in packs of 10 (SCPG2) Spare keys available (SCPK2)

BPS-1 24V 1 AMP BOXED POWER SUPPLY ACCESSORIES BPS-2 24V 2 AMP BOXED POWER SUPPLY BPS-5 24V 5 AMP BOXED POWER SUPPLY * boxed power supplies require 2 x 12V batteries (not supplied) BAT7 12V 7.0ah SLA BATTERY BAT18 12V 18ah SLA BATTERY DR916-KP SPARE KEEPER PLATE (for use with DR916-24/240) DR916-24 24V DC DOOR HOLDER DR916-240 240V AC DOOR HOLDER DR916-FMB FLOOR MOUNTING BRACKET (for use with DR916-24/240) MAGZC816 4 ZONE EXPANDER CARD (for use with MAG816) MAGSC816 4 ZONE SOUNDER EXPANDER CARD (for use with MAG816)

FIRELINE PRODUCT CODES CONVENTIONAL FIRE ALARM PANELS MAG2P 2 ZONE POLYCARB cased conventional FIRE PANEL MAG2 2 ZONE METAL cased conventional FIRE PANEL MAG4P 4 ZONE POLYCARB cased conventional FIRE PANEL MAG4 4 ZONE METAL cased conventional FIRE PANEL MAG816 8 ZONE (exp to 16 zone) ABS cased conventional FIRE PANEL MAGZC-816 4 ZONE EXPANDER CARD, for use with MAG816 MAGSC-816 4 ZONE SOUNDER EXPANDER CARD, for use with MAG816 CONVENTIONAL FIRE ALARM DETECTORS PSD-2 conventional OPTICAL SMOKE detector & diode BASE CSD-2 conventional COMBINED SMOKE + HEAT detector & diode BASE FHD-2 conventional FIXED TEMPERATURE HEAT detector & diode BASE RHD-2 conventional RATE OF RISE HEAT detector & diode BASE MANUAL CALL POINTS SCP-2 conventional SURFACE mounting red CALL POINT FCP-2 conventional FLUSH mounting red CALL POINT SCP2-COVER TRANSPARENT Hinged COVER for use with all SCP2/FCP2 SCPG-2 SPARE GLASS for SCP-2 / FCP-2 (pack of 10) SCPK-2 SPARE KEYS for SCP-2 / FCP-2 (pack of 10) FIRE ALARM SOUNDERS (24v) BA-1R RED BANSHEE sounder (87-112dBA) BA-1W WHITE BANSHEE sounder (87-112dBA) MA-1 MULTI ALERT sounder c/w surface BACK BOX (103dBA) TR-1 RED TRITONE sounder c/w DEEPBASE (87.5dBA) BS-1R flush mounting RED BEDROOM sounder (90dBA) BS-1W flush mounting WHITE BEDROOM sounder (90dBA) DBS-1 DETECTOR BASE sounder (93dBA) FIRE ALARM BELLS (24v) IFB-1 INTERNAL 150mm FIRE BELL (95dBA) WFB-1 WEATHERPROOF 200mm FIRE BELL (95dBA) STROBES (24v) FS-1 1 WATT (red lens) STROBE FS-2 2 WATT (red lens) STROBE FS-3 3 WATT (red lens) STROBE ZRL2 REMOTE LED INDICATOR surface plate COMBINATION SOUNDERS & STROBES (24v) CB-1 combined RED BANSHEE sounder + (red lens) STROBE (97dBA) CB-2 combined MULTI ALERT sounder + (red lens) STROBE (97dBA) CB-3 combined RED TRITONE sounder + (red lens) STROBE (87.5dBA) 12v BATTERIES BAT7 12v 7.0ah SLA BATTERY BAT18 12v 18.0ah SLA BATTERY DOOR RETAINERS DR916-24 24vDC conventional fire alarm DOOR HOLDER DR916-240 240vAC conventional fire alarm DOOR HOLDER DR916-FMB FLOOR MOUNTING BRACKET for use with DR916-24 / 240 DR916-KP spare KEEPER PLATE for use with DR916-24 / 240 24v BOXED POWER SUPPLIES BPS-1 24v 1 AMP boxed POWER SUPPLY BPS-2 24v 2 AMP boxed POWER SUPPLY BPS-5 24v 5 AMP boxed POWER SUPPLY www.espuk.com