Addressable and Conventional Fire Protection

Similar documents
The complete conventional fire warning system

System 800 Addressable Fire Detection & Alarm System

ANALOGUE ADDRESSABLE FIRE PANEL MAGPRO96 INSTALLATION AND PROGRAMMING MANUAL

Installation, Operating and Maintenance Manual

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Fire Product Catalog

Intelligent addressable fire alarm control panel

EFBW series - BiWire Ultra control panel

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Xenex Conventional Fire Detection & Alarm System

Touch Screen 1 loop Addressable Fire Alarm Panel

Conventional Fire Detection

Conventional Fire Alarm System 2014 V1.2

2017 Fire Alarm Systems Product catalogue

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Sita200plus. 200detectors. Single loop analogue addressable System

CODESEC FIRE ALARM SYSTEMS. security technologies

intelligent solutions

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Solution F2. Fire Alarm Control Panels one step ahead.

INPUT / OUTPUT MINI MODULES

2019 Fire Alarm Systems Product catalogue

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Excel-EN Conventional Fire Control Panel

OPERATION AND INSTALLATION MANUAL

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

good things in small packages

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Intelligent Addressable Fire Alarm System

Our technology, your peace-of-mind. Product list

Wireless Fire Solutions

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

MINERVA MX. 800 Series Ancillary Equipment

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Wireless Fire & Security Solutions. Fire Product Showcase

Intelligent Security & Fire Ltd

The complete wirefree security alarm solution

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

IGD.CO.UK

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

2013 Fire Alarm Systems Product catalogue

SALES SUPPORT DOCUMENT

The EN54 Part 2 & 4 Fire System

4 wire conventional alarm system

ACP10 & ACP50 Security Systems

Addressable Fire Alarm Control Panel

Saxon Range 1-8 Zone Convertional Control Panels

Intelligent Single Loop Fire Alarm Control Panel

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

FEC400 Series. Installation Manual

Intelligent Security & Fire Ltd

Industries. As a premier global manufacturing company, we believe that great brands are

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Conventional Fire Alarm System Product Range Guide

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

CONTENTS NBM-06 Bell (6") Page 1

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

Carbon Monoxide (CO) detection system

Across-the-Line SERIES MP300 Combined Manual and Automatic

The EN54 Part 2 and 4 Fire System

Evolution Analogue Addressable Fire System

FIRElux Emergency Lighting

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Reflective Optical Beam Smoke Detector User Guide

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Intelligent Security & Fire Ltd

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

End To End Optical Beam Smoke Detector. Additional Information

LF-4000 Series Conventional Fire Alarm Control Unit

Solution F1. Fire Control Panels the new generation

30.45 Electric Release PDRP-2001

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Conventional Leaflets

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Specification/ Data Sheet

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Intelligent 2 & 4 Loop Fire Alarm Control Panels

BSR Addressable Fire Detection control panel. Installation operation manual

Variable Frequency Drive SERIES MP800 VFD

ECC-50/100C. Emergency Command Center

The new detector from Rafiki

Fire control panels FC360

AL800ULADA. NAC Power Extender. Installation Guide

Soft Start Series MP700 Solid State, Reduced Voltage

AL600ULADA. NAC Power Extender. Installation Guide

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

MINERVA MZX125 Digital Addressable Fire Detection System

SP40S-D. Kingfisher Company, inc. Features: Description:

AND ARCHITECT SPECIFICATIONS

THIS GUIDE SUPPORTS MATRIX 424 & 832 CONTROL PANELS

Transcription:

Addressable and Conventional Fire Protection Simply reliable

F I R E P R O T E C T I O N The MAGPro and Fireline systems has been created to balance performance, reliability and aesthetics whilst being fully compliant with CPR and certified to standards. The range includes everything required to complete a high quality, durable, addressable fire alarm installation. ADDRESSABLE MAGPRO16-16 Zone Fire Panel................................... 4 MAGPRO96-96 Zone Fire Panel................................... 5 Addressable Detectors............................................. 6 MAGPRO-WS Sounder.............................................. 7 MAGPRO-WSS - Sounder Strobe.................................... 7 MAGPRO-CP - Manual Call Point.................................... 8 MAGPRO-PROG - Programming Tool................................ 8 MAGPRO-iM - Isolator Module...................................... 8 MAGPRO-MINI - Mini Input Module.................................. 8 Addressable Accessories........................................... 9 Addressable Modules............................................. 10 CONVENTIONAL Conventional Fire Alarm Kits...................................... 12 MAG2P - 2 Zone Fire Panel....................................... 13 MAG4P - 4 Zone Fire Panel....................................... 14 MAG816-8 Zone Fire Panel...................................... 15 Conventional Fire Alarm Detectors................................ 16 Conventional 12V Fire Alarm Detectors............................ 17 Conventional Sounders........................................... 18 Conventional Fire Bells........................................... 18 SCP2-R - Resettable Call Point.................................... 19 Conventional Accessories......................................... 19 2 ESP Addressable and Conventional Fire Protection www.espuk.com

ESP Addressable and Conventional Fire Protection www.espuk.com 3

A D D R E S S A B L E F I R E P A N E L S MAGPRO16 - Addressable 16 Zone Fire Panel 16 zone addressable fire alarm panel supplied with 1 loop. Expandable to 2 loops using MAGPRO16-L250. A maximum of 250 devices can be connected to each loop. 16 Zones Maximum 250 devices per loop Memory Log: 10,000 events Networkable up to 32 Panels 4 x 40 character LCD display Free programing software Micro USB port for PC connection Loop & battery calculator software included Certified to 2/4 MAGPRO16-L250 Single Loop Expander 250 Devices INPUTS Loops 1 expandable to 2 Devices Per Loop 250 Protocol POWER Mains Fail Consumption MAGPRO 125mA DC 1 LOOP 213mA DC 2 LOOP Mains Supply 230V AC + - 10% Max Loop Current Backup 500mA DC 1x12V 17Ah OUTPUTS 2 Sounders 24v DC @ 500mA 4 Programable Relays 24v DC @ 100mA 3 Monitored Outputs 24v DC @ 100mA 3 Monitored Inputs Volt free contacts ENVIRONMENT Working Temperature -5C TO +40C Storage -10C TO 60C Humidity 0-95% Weight 3.6KG Dimensions 320 x 220 x 80mm 4 ESP Addressable and Conventional Fire Protection www.espuk.com

MAGPRO96 - Addressable 96 Zone Fire Panel 96 zone addressable fire alarm panel supplied with 1 loop. Expandable to 4 loops using additional MAGPRO96-L250 s. A maximum of 250 devices can be connected to each loop. 96 Zones Maximum 250 devices per loop Memory Log: 10,000 events Networkable up to 32 Panels 320 x 240 pixel touch screen display Free programing software Micro USB port for PC connection Loop & battery calculator software included Certified to 2/4 MAGPRO96-L250 Single Loop Expander 250 Devices INPUTS Loops 1 expandable to 4 Devices Per Loop 250 Protocol MAGPRO POWER Mains Fail Consumption 285mA DC - 1 LOOP 360mA DC - 2 LOOP 435mA DC - 3 LOOP 510mA DC - 4 LOOP Mains Supply 230V AC + - 10% Max Loop Current 500mA DC Backup 1x12V 17Ah OUTPUTS 1 Sounder 24v DC @ 300mA 4 Programable Relays 110v ac @ 1A 2 Monitored Outputs 24v DC @ 300mA 1 Auxillary Output 24v DC @ 300mA 1 Fault Output 24v DC @ 300mA ENVIRONMENT Working Temperature -5C TO +40C Storage -10C TO 60C Humidity 0-95% Weight 4.2KG Dimensions 456 x 350 x 125mm ESP Addressable and Conventional Fire Protection www.espuk.com 5

A D D R E S S A B L E D E TE C TO R S MAGPRO-SD1 - Addressable Smoke Detector Sensitivity level selectable from the control panel - High/Normal/Middle/Low Protected area - 120m 2 Installation height - up to 16m Day/Night mode Low profile design LED indication with 360 visibility Certified to 7 Base ordered separately see below MAGPRO-DB Detector Base MAGPRO-DBS Sounder Base MAGPRO-DBSS Sounder Strobe Base MAGPRO-HD1 - Addressable Heat Detector Can work as a fixed temperature or rate of rise detector Class A1R, A2S, BS selectable from the control panel Day/Night mode Protected area - up to 35m 2 Installation height - up to 3.5m Low profile design LED indication with 360 visibility Certified to 5 Base ordered separately see below MAGPRO-DB Detector Base MAGPRO-DBS Sounder Base MAGPRO-DBSS Sounder Strobe Base 6 ESP Addressable and Conventional Fire Protection www.espuk.com

MAGPRO-HSD1 - Combined Smoke & Heat Detector Sensitivity selectable from the control panel - High/Normal/Middle/Low Class A1R temperature sensor (according to -5) Protected area - up to 120m 2 Installation height - up to 16m Day/Night mode Low profile design LED indication with 360 visibility Certified to 5/7 Base ordered separately see below MAGPRO-DB Detector Base MAGPRO-DBS Sounder Base MAGPRO-DBSS Sounder Strobe Base MAGPRO-WS - Sounder Piezo sounder Adjustable sound level - 92dB/100 db 32 sound types selectable from the panel Loop synchronization and powered Certified to 3 Base MAGPRO-DB ordered separately MAGPRO-WSS - Sounder Strobe Piezo sounder Adjustable sound level - 92dB/100 db 32 sound types selectable from the panel Loop synchronization and powered Certified to 3 Base MAGPRO-DB ordered separately MAGPRO-DB Detector Base MAGPRO-DB Detector Base ESP Addressable and Conventional Fire Protection www.espuk.com 7

A D D R E S S A B L E A C C E S S O R I E S MAGPRO-CP - Manual Call Point MAGPRO-PROG - Programming Tool Resettable call point Certified to 11 A Built in isolator IP40 Rated Optional protective plastic cover MAGPRO-CPC Optional plastic cover For reading/writing addresses and setting of parameters within detectors and modules. Built in MAGPRO-DB standard base Mains or battery powered (4 x 1.5V not included) Programming cable included MAGPRO-iM - Loop Isolator Module MAGPRO-MINI - 1 Input Module Provides protection against short circuit Auto reset upon removal of short circuit 4 x cable entry points A maximum of 30 devices between two isolators Certified to 17 Single volt free contact Compact size 58mm x 25mm x 12mm Example applications - Integration of third party control devices Compliant to 18 8 ESP Addressable and Conventional Fire Protection www.espuk.com

ZRL2 - LED Indicator Plate Flash rate - permanent Current - 28 ma Max Operating Voltage Range - 5-28V DC BAT18 - Back up Battery 12V 17ah SLA back up battery 24V Boxed power supplies BPS-1-24V 1 amp Boxed power supply BPS-2-24V 2 amp Boxed power supply BPS-5-24V 5 amp Boxed power supply Nb Boxed power supplies require 2 x 12V batteries (not supplied) Door Holders DR916-24 - 24V DC Door Holder DR916-240 - 240V AC Door Holder DR916-FMB - Floor Mounting Bracket DR916-KP - Spare Keep Plate ESP Addressable and Conventional Fire Protection www.espuk.com 9

A D D R E S S A B L E M O D U L E S MAGPRO-R - Mains Relay Output Module with Isolator Suitable for control of 240VAC voltage circuits up to 5A Loop powered Built in isolator Compliant to 18 Example application - AC 240V door magnet override MAGPRO-2i2O - 2 Input 2 Output Module with Isolator 2 Monitored Inputs 2 Outputs Loop powered Built in isolator Certified to 18 Example application - Link to monitoring station signalling devices MAGPRO-0i4O - 4 Output Module with Isolator 4 Relay outputs Loop powered Built in isolator Certified to 18 Example applications - Shutdown of ventilation equipment and door override 10 ESP Fire Protection and Emergency Lighting Catalogue www.espuk.com

MAGPRO-4i0O - 4 Input Module with Isolator 4 Monitored Inputs Loop powered Built in isolator Certified to 18 Example applications - Input from external equipment, extinguishing/sprinkler panel MAGPRO-1OSi - Conventional Sounder Module with Isolator Integrate conventional sounders into an addressable system Loop powered Built in isolator Requires 24V PSU Compliant to 18 MAGPRO-CZM - Conventional Zone Module with Isolator Integrate conventional detectors into an addressable system Max number of detectors in one zone - 32 Loop powered Built in isolator Certified to 18 Example applications - Integrate conventional equipment i.e. beam detectors ESP Fire Protection and Emergency Lighting Catalogue www.espuk.com 11

CONVENTIONAL FIRE KITS AND PANELS FLK2P - 2 Zone Conventional Fire Alarm Kit FLK2P kit contains: MAG2P 2 zone fire panel 6 x PSD-2 Optical smoke detectors complete with bases 2 x SCP-2R Resettable call points 2 x BA-2R Banshee sounders 1 x BAT7 12v 7.0ah SLA battery FLK4PH - 4 Zone Conventional Fire Alarm Kit FLK4PH kit contains: MAG4P 4 zone fire panel 5 x PSD-2 Optical smoke detectors complete with bases 1 x FHD-2 Fixed temperature heat detector complete with base 2 x SCP-2R Resettable call points 2 x BA-2R Banshee sounders 1 x BAT7 12v 7.0ah SLA battery 12 ESP Addressable and Conventional Fire Protection www.espuk.com

MAG2P - 2 Zone Fire Panel 2 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call points per zone Integral evacuate alarm button Class change facility Enable/disable security key One man walk test facility Volt free fire change over relay Volt free fault change over relay Individual sounder circuit fault ID Individual zone/sounder isolate Certified to 2/4 Requires only 1x12v battery MAG2P - ABS casing MAG2 2 Zone Fire Panel Metal Casing INPUTS Max detectors per zone 30 Thresholds for 0-2 ma (Fault condition) zone conditions 2-6 ma (Normal condition) 6-110 ma (Fire condition) 110 ma - Short (Fault condition) POWER Mains fail consumption 50mA Mains supply 230 VAC ± 10% Standby supply 1 x 7ah 12V S.L.A. Battery Power availability 0.7 amps OUTPUTS Sounder 1 24V (max 300mA fused) Sounder 2 24V (max 300mA fused) Fault/fire relay Volt free 500mA @ 24V (max load) Auxiliary output 24VDC (300mA fused) ENVIRONMENT Working Temperature 0 to 40ºC Storage Temperature -20 to 60ºC Humidity 0-95% Dimensions MAG2P 340 x 290 x 100mm Dimensions MAG2 200 x 290 x 80mm Weight MAG2P - 2.1Kg MAG2-2.7Kg ESP Addressable and Conventional Fire Protection www.espuk.com 13

CONVENTIONAL FIRE PANELS MAG4P - 4 Zone Fire Panel 4 programmable zones Active end of line monitoring and head removal 30 fire detectors per zone Unlimited number of call points per zone Integral evacuate alarm button Class change facility Enable/disable security key One man walk test facility Volt free fire change over relay Volt free fault change over relay Individual sounder circuit fault ID Individual zone/sounder isolate Certified to 2/4 Requires only 1x12v battery MAG4P - ABS casing MAG4-4 Zone Fire Panel Metal Casing INPUTS Max detectors per zone 30 Thresholds for 0-2 ma (Fault condition) zone conditions 2-6 ma (Normal condition) 6-110 ma (Fire condition) 110 ma - Short (Fault condition) POWER Mains fail consumption 50mA Mains supply 230 VAC ± 10% Standby supply 1 x 7ah 12V S.L.A. Battery Power availability 0.7 amps OUTPUTS Sounder 1 24V (max 300mA fused) Sounder 2 24V (max 300mA fused) Fault/fire relay Volt free 500mA @ 24V (max load) Auxiliary output 24VDC (300mA fused) ENVIRONMENT Working Temperature 0 to 40ºC Storage Temperature -20 to 60ºC Humidity 0-95% Dimensions MAG4P 340 x 290 x 100mm Dimensions MAG4 320 x 220 x 80mm Weight MAG4P - 2.5Kg MAG4-3.5Kg 14 ESP Addressable and Conventional Fire Protection www.espuk.com

MAG816-8 Zone Fire Panel expandable to 16 zones Up to 16 programmable zones Up to 16 sounder circuits Active end of line monitoring and head removal Up to 32 fire detectors per zone Unlimited number of call points per zone Integral evacuate alarm button Repeater facility Class change facility Enable/disable security key One man walk test facility Volt free fire/fault change over relay Individual sounder circuit fault ID Individual zone/sounder isolate Alarm delay options Certified to 2/4 Requires 1 x 12V batteries ABS casing FIRE ZONE / SOUNDER OUTPUT MATRIX MAGZC816 4 Zone Expander Card MAGSC816 4 Zone Sounder Expander Card Number of zone cards fitted 2 3 4 2 3 1 2 1 Number of sounder cards fitted 0 0 0 1 1 2 2 3 Number of zones 8 12 16 8 12 4 8 4 Number of sounder outputs 4 4 4 8 8 12 12 16 NB The MAG816 features 4 sounder circuits. Space is provided for up to 4 extra expansion cards of any combination. Sounder cards carry 4 sounder circuits, Zone cards carry 4 fire zones. The MAG816 is supplied as standard with 8 fire zones and 4 sounder circuits. INPUTS Max. detectors per zone 32 Thresholds for 0-2 ma (Fault condition) zone conditions 2-10 ma (Normal condition) 10-110 ma (Fire condition) 110mA - + Short (Fault condition) POWER Mains fail consumption 130mA (1 zone expander) 260mA (4 zone expanders) Mains supply 230 VAC ± 10% Standby supply 1 x 18ah 12V S.L.A. Batteries Power availability 0.7 amps OUTPUTS On board sounder circuits (4) 300mA @ 24V fuse resettable (PTC) Sounder expander cards (4) 150mA @ 24V fuse resettable (PTC) Fault/fire relay Volt free 500mA @ 24V (max load) Auxiliary output 24VDC (300mA fused) ENVIRONMENT Working Temperature 0 to 40ºC Storage Temperature -20 to 60ºC Humidity 0 to 93% Dimensions (mm) 456 x 350 x 125mm Weight 4.2 KG ESP Addressable and Conventional Fire Protection www.espuk.com 15

CONVENTIONAL DETECTORS Conventional Fire Alarm Detectors These Fireline detectors have been developed to provide a perfect compliment to the Fireline MAG panels. All detectors are supplied with a diode base. Fully compliant with CPR and certified to standards. PSD-2 Optical smoke detector CSD-2 Combined optical smoke & fixed heat detector FHD-2 Fixed temperature heat detector RHD-2 Rate of rise heat detector MODEL PSD-2 CSD-2 FHD-2 RHD-2 Description Optical smoke Combined smoke/heat Fixed temp heat Rate of rise heat Type Conventional Conventional Conventional Conventional Approval -7-7, -5-5 -5 Class N/A A1R A2S A1R Operating Voltage 9-30VDC 9-30VDC 9-30VDC 9-30VDC Standby Current @ 24v < 60µA < 60µA < 60µA < 60µA Alarm Current @ 24v 49mA 49mA 49mA 49mA Wire Gauge 0.4mm - 2.0mm TWIN 0.4mm - 2.0mm TWIN 0.4mm - 2.0mm TWIN 0.4mm - 2.0mm TWIN Operating Temperature -10 C to 60 C -10 C to 60 C -10 C to 60 C -10 C to 60 C Test Facility Simulated Smoke Simulated Smoke/ Heat Heat Source Heat Source 16 ESP Addressable and Conventional Fire Protection www.espuk.com

12V Fire Alarm Detectors The new range of Fireline detectors have been developed to provide a perfect compliment to 12V hardwire intruder alarm systems. All detectors are supplied with a relay base. Fully compliant with CPR and certified to standards. PSD-212 12V Optical smoke detector CSD-212 Combined optical smoke & fixed heat detector FHD-212 Fixed temperature heat detector RHD-212 Rate of rise heat detector MODEL PSD-212 CSD-212 FHD-212 RHD-212 Description Optical smoke Combined smoke/heat Fixed temp heat Rate of rise heat Type Conventional Conventional Conventional Conventional Approval -7-7, -5-5 -5 Class N/A A1R A2S A1R Operating Voltage 9-30VDC 9-30VDC 9-30VDC 9-30VDC Standby Current @ 12v < 50µA < 50µA < 50µA < 50µA Alarm Current @ 12v 29mA 29mA 29mA 29mA Wire Gauge 0.4mm - 2.0mm TWIN 0.4mm - 2.0mm TWIN 0.4mm - 2.0mm TWIN 0.4mm - 2.0mm TWIN Operating Temperature -10 C to 60 C -10 C to 60 C -10 C to 60 C -10 C to 60 C Test Facility Simulated Smoke Simulated Smoke/ Heat Heat Source Heat Source ESP Addressable and Conventional Fire Protection www.espuk.com 17

SOUNDERS AND ACCESSORIES Conventional Sounders Sound Output @ 1m 89-110 dba Current - 3-39 ma IP Rating - IP45 BA-2R - Red Banshee Sounder BA-2W - White Banshee Sounder Bedroom Sounders Sound Output @ 1m - 90 dba Current - 7 ma BS-1R - Red Bedroom Sounder BS-1W- White Bedroom Sounder MA1 - Multi Alert Sounder Sound Output @ 1m - 103 dba Current - 15 ma IP Rating - IP55 DBS1 - Detector Base Sounder Sound Output @ 1m - 93 dba Current - 18 ma WFB-1 - Weatherproof Fire Bell Sound Output - 95 dba Current - 25 ma 8 diameter IP Rating - IP55 IFB-1 - Internal Fire Bell Sound Output - 95 dba Current - 11 ma 6 diameter IP Rating - IP21C 18 ESP Addressable and Conventional Fire Protection www.espuk.com

SCP2-R - Resettable Call Point ZRL2 - LED Indicator Plate Surface or flush mounting Complete with surface back box Spare keys available - SCP2RK Optional plastic cover - SCP2-COVER Flash rate - permanent Current - 28 ma Max Operating Voltage Range - 5-28V DC FS-1-1 watt Strobe CB-1R - Sounder and Strobe Flash rate - 60/minute Current - 42, 84, 126 ma IP Rating - IP65 Sound Output - 89-110 dba Flash rate - 60/minute Current - 40 ma plus sounder IP Rating - IP45 Back up Batteries BAT18-12V 17ah SLA back up battery for MAG816 BAT7-12V 7.0ah SLA back up battery for MAG2P, MAG2, MAG4P and MAG4 24V Boxed power supplies BPS-1-24V 1 amp Boxed power supply BPS-2-24V 2 amp Boxed power supply BPS-5-24V 5 amp Boxed power supply Nb Boxed power supplies require 2 x 12V batteries (not supplied) MAGR - 8 Zone Relay Module MAG816 expander module providing 8 relay switches for zone activation Separate zone (max. 8) activation in fire condition N.O & N.C options Door Holders DR916-24 - 24V DC Door Holder DR916-240 - 240V AC Door Holder DR916-FMB - Floor Mounting Bracket DR916-KP - Spare Keep Plate ESP Addressable and Conventional Fire Protection www.espuk.com 19

Elite Security Products Unit 7, Target Park, Shawbank Rd Lakeside, Redditch B98 8YN Telephone: +44 (0) 1527 51 51 50 Elite Security Products Ireland 18 Corrig Road, Sandyford Ind. Est, Dublin 18 Ireland Telephone: +353 (1) 281 11 22 info@espuk.com www.espuk.com ESPMAGFIRE 06/14 E&OE - Errors and omissions excepted