Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Similar documents
Comparison of drying characteristics and quality of copra obtained in a forced convection solar drier and sun drying

V.R.Badgujar * * Department of Mechanical Engineering,Pimpri Chinchwad College Of Engineering,

Thermal Performance Of Low Cost Solar Bamboo Dryer

Solar Drying Techniques And Performance Analysis: A Review

Design and Optimization of Domestic Solar Dryer

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Drying of agricultural products using forced convection indirect solar dryer

Performance and Evaluation of Pop Can Solar Dryer for Batch Products

Design and Experimental Studies on Modified Solar Dryer

Available online Journal of Scientific and Engineering Research, 2018, 5(10): Research Article

Available online at I-SEEC Proceeding - Science and Engineering (2013) 19 26

ANALYSIS OF THERMAL PERFORMANCE OF SOLAR AIR DRYER FOR THREE DIFFERENT ABSORBER PLATES

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

PROCESSING OF VEGETABLES IN A SOLAR DRYER IN ARID AREAS

Drying of Fruits, Vegetables, Spices and Medicinal Plants with a Mixed-Mode Solar Drying System with Internal Reflectors

Construction and Performance Study of a Rock Bed Integrated Green House Type Solar Air Heater with Solar Dryer

Effect of Air Velocity and Pre Treatment on Drying Characteristics of Tomato Slices during Solar Tunnel Drying

DESIGN AND CONSTRUCTION OF FORCED/NATURAL CONVECTION SOLAR VEGETABLE DRYER WITH HEAT STORAGE

Design and Fabrication of Solar dryer with Spiral Water Heater

Review Article Solar Drying Technology: Potentials and Developments

A STUDY ON DRYING OF AMLA USING A HYBRID SOLAR DRYER

Experimental Investigation to Assess the Performance of Desiccant Integrated Chilly Dryer

[Harikeishnan*et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Solar Drying of Fruits and Vegetables

DEVELOPMENT AND PERFORMANCE EVALUATION OF A LOCALLY FABRICATED PORTABLE SOLAR TUNNEL DRYER FOR DRYING OF FRUITS, VEGETABLES AND MEDICINAL PLANTS

Chapter 3 DESIGN OF THE STUDY

Specific Energy Consumption of Heat Pump Drying System

Asian Journal on Energy and Environment

DEVELOPMENT OF FORCED CONVECTION SOLAR ONION DRYER

DESIGN AND FABRICATION OF SOLAR BIOMASS DRYER USING FORCED CONVECTION PROJECT REFERENCE NO.: 38S INTRODUCTION

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

Development of Solar Tunnel Dryer for Drying Tomato (Lycopersicum esculentum) Slices

Solar driers applied for drying of agricultural and foodproductswitha retrospective study

Performance Investigation of a Natural Convection Grain Dryer for Paddy Drying

ISSN: [Agcaoili S. O., 7(3): March, 2018] Impact Factor: 5.164

Numerical investigation of a solar greenhouse tunnel drier for drying of copra

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Effect of Relative Humidity on Oven Temperature of Locally Design Solar Carbinet Dryer

Mathematical Simulation of Longan Fruit Drying

Drying principles and general considerations

Corn drying experiments by pilot dryer

A Regional Research and Dissemination Programme. Phase III SOLAR BOX DRYER DESIGN, CONSTRUCTION AND OPERATION MANUAL

A STUDY ON SOLAR DRYING SYSTEM FOR FISH PRESERVATION

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

An Experimental Investigation and Performance Analysis of a Solar Drying of Bitter Gourd using an Evacuated-Tube Air Collector

DEVELOPMENT OF A PAR-BOILED RICE SOLAR DRYER

Use of heat pump dehumidifiers on industrial drying of chili

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Design, Construction and Testing of Simple Solar Maize Dryer

PERFORMANCE EVALUATION OF A MIXED MODE SOLAR DRYER

Performance Investigation and Development of Solar Dryer Tunnel Type Apparatus of Cocoa

Drying characteristics of Air Dried Sheet (ADS) Rubber

Experimental Performance of Solar Collector cum Regenerator for Coupling with a Liquid Desiccant Cooling System

PERFORMANCE ANALYSIS OF A SOLAR GRAPE DRYER WITH THERMAL ENERGY STORAGE BY PCM

SCIENCE & TECHNOLOGY

Development, Design, and Performance of a PV-Ventilated Greenhouse Dryer

Influence of temperature and drying air velocity on the kinetics of convective drying in the food industry

International Journal of Advance Research in Engineering, Science & Technology SOLAR HUMIDIFIER

INNOVATIVE SOLAR TUNNEL DRYER

Research Article Design and Evaluation of Solar Grain Dryer with a Back-up Heater

An Experimental Study on Drying of Pistacia Terebinthus in a Fixed Bed Dryer

Fabrication & Performance Analysis of Solar Water Heater Using Porous Medium & Agitator

PERFORMANCE OF FORCED CONVECTION EVACUATED TUBE SOLAR GRAIN DRYER. BOOKER ONYANGO OSODO B. Ed.(TECH); M. Phil (Tech. Ed) (J98/25749/2011)

Key Words: Microalgae; Solar Dryer; Exergy Analysis; Energy Analysis;

Performance Evaluation of a Mixed-Mode Solar Dryer

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

Experimental Study on a Solar Tunnel. Heat Pump Dryer for Cocoa Beans

Performance analysis of solar water heater in NEH region of India

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

PERFORMANCE EVALUATION OF A DRYER FOR PROCESSED LOCUST BEAN CONDIMENTS

DESIGN, FABRICATION AND PERFORMANCE ANALYSIS OF A MIXED MODE SOLAR DRYER FOR DRYING VEGETABLES.

EFFECTIVE UTILIZATION OF SOLAR ENERGY IN AIR DRYER

Analysis of the performance profile of the NCERD thermosyphon solar water heater

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

DESIGN AND PERFORMANCE EVALUATION OF DIRECT MODE SOLAR DRYER

FABRICATION AND COMPARISON OF SOLAR WATER HEATER WITH AND WITHOUT SEMI CIRCULAR TROUGH

PERFORMANCE EVALUATION OF RACK TYPE SOLAR DRYER

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

AN EXPERIMENTAL INVESTIGATION OF FORCED CONVECTION FLAT PLATE SOLAR AIR HEATER WITH STORAGE MATERIAL

Design and Performance Analysis of One Ended Evacuated Tubes at Different Air Flow Rates Nitin Panwar 1

Keywords : Evaporative cooling, Saturation efficiency, Cooling capacity, Cooling pad, Cellulose, Aspen, Coconut coir. IJSER

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Solar air heater duct having triangular protrusions As roughness elements on absorber plate

Experimental Investigation of Phase Change Material Based Thermal Storage System for Solar Dryer Applications

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

Experimental assessment of a PCM to air heat exchanger storage system for building ventilation applications

DIFFERENT TYPES OF SOLAR DRYER FOR AGRICULTURAL AND MARINE PRODUCTS: A REFERENCE GUIDE

Performance Analysis of Solar Air Heater Using Three Wire Mesh

Mango Sheet Drying by the Solar Dryer Combine with Electric Coil

EXPERIMENTAL STUDIES ON SOLAR ALUMINIUM CAN AIR HEATER WITH AND WITHOUT LATENT HEAT STORAGE

Research Article Design and Development of Walk-In Type Hemicylindrical Solar Tunnel Dryer for Industrial Use

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Experimentation of solar dryer with desiccant material for agricultural products

Transcription:

International Journal of Engineering Research and Technology. ISSN 0974-3154 Volume 6, Number 4 (2013), pp. 441-448 International Research Publication House http://www.irphouse.com Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air C. Velmurugan, S. Sivakumar, Ashwin Bala, N. Harish Kumar and S. Prithviraj Department Of Mechanical Engineering, Kumaraguru College of Technology, Saravanampatty, Coimbatore, Tamil Nadu, INDIA. Abstract An indirect forced convection solar drier integrated with recirculation of air has been developed and its performance is tested for drying grapes under the metrological conditions of Coimbatore, India. The system consists of a flat plate solar air heater with lens and recirculation tube, a drying chamber and micro controller. Drying experiments have been performed at an air flow rate of 3.197kg/s. Drying of grapes in a forced convection solar drier reduces the moisture content from around 80% (wet basis) to the final moisture content about 10.6% in 22.6h. Average drier efficiency was estimated to be about 20.92%. The specific moisture extraction rate was estimated to be 0.87 kg/kwh. Keywords: Solar drier, grapes drying, microcontroller, forced convection. 1. Introduction In India, sun drying is the most commonly used method to dry the agricultural materials grains, fruits and vegetables. In sun drying, the crop is spread in a thin layer on the ground and exposed directly to solar radiation and other ambient conditions. The rate of drying on various parameters such as solar radiation, ambient temperature, wind velocity, relative humidity, and initial moisture content, type of crops, crop absorptive and mass of product per unit exposed area[1]. This form of drying has many drawbacks, such as degradation by windblown, debris, rain and insect infestation that will result in contamination of the product. Drying rate will reduce due to intermittent

442 N. Harish Kumar et al sunshine, interruption and wetting by rain. Solar driers using natural convection or forced circulation have been investigated to overcome the problems [2]. For commercial applications, the ability of the drier to process continuously throughout the day is very important to dry the products to its safe storage level and to maintain the quality. Normally copper plates are employed to increase the collector outlet temperature, which in turn increases the collector thermal efficiency. The solar drier is an energy efficient option in the drying process [3]. Use of forced convection solar driers seems to be an advantage compared to traditional methods and improves the quality of the product considerably[4,5]. Use of forced convention solar driers seems to be an advantage and improves quality of the product considerably [6]. Normally thermal storage systems are employed to store the heat, which includes sensible heat storage [7]. Common sensible heat storage materials used to store sensible heat are water, gravel bed,sand, clay, concrete, etc. [8]. The objective is to develop a indirect forced convection solar drier integrated with recirculation of air to increase the collector outlet temperature for drying of grapes. 2. Materials and Methods 2.1 Experimental set-up A schematic diagram of the forced convection solar drier is shown in the figure 1. The solar drier consists of flat plate solar air heater of area (60*60) cm² connected with the drying chamber. The solar air heater has 2 mm thick copper absorber plate coated with black paint to absorb the maximum solar radiation. The absorber plate is placed directly behind the transparent cover with a layer of air separating it from the cover (glass) with a layer of air separating it from the cover. In order to improve the mass flow rate of the air, the air to be heated is passed between the transparent cover (glass) and the absorber plate. To increase the temperature of air by green house effect, a glass cover of 5 mm thickness was placed. The gap between the glass and the absorber surface was maintained at 25 mm inlet. The drying chamber is made up of mild steel sheet of 2mm thickness with two trays of width, depth and height of (30*30*60) cm respectively. The drier is capable of holding about 500g of grapes per batch. The drying chamber was insulated with glass wool of 10 mm thickness. The system is oriented to face south to maximize the solar radiation incident on the solar collector. The potential sunshine duration was about 8 hours per day only. 2.2 Experimental procedure Only good quality grapes were used in the experiments. About 500g of fresh grapes were dried as whole fruits, without any chemical pre-treatment, until the required final moisture content was attained. The fresh grapes were loaded over the trays of drier chamber having about 90% perforation. The initial moisture content was calculated by taking five different samples. Then the exhaust fan was switched on and the air flow rate through the solar flat plate collector was adjusted to 3.917 kg/s [9].The velocity of air at inlet of the tray was measured with the help of vane type anemometer. Solar

Experimental & Analytical Investigation on Modified Solar Dryer 443 intensity was measured using solar intensity meter. During sunshine hours the air flow over the absorber plate gets heated and simultaneously the grapes in the drying chamber get dried and its moisture gets reduced. Temperature at inlet and outlet of the solar collector and the drying chamber were measured at every one hour interval. The experiment was conducted for 8 hours during potential sunshine hours. During idle conditions, he grapes were covered with polyethylene sheet to avoid de-absorption of moisture. All the experimental observations were made after the driver attains the steady state condition. The experiments were repeated thrice and an average was considered. The drying characteristics of grapes such as moisture content, drying rate, specific moisture extraction rate and drier thermal efficiency were determined by using Eqns. (1) to (3) respectively. Figure 1: Forced convection solar drier. 2.3. Determination of moisture content The quantity of moisture present in a material can be presented on wet basis and expressed as percentage. About 10g sample were taken and kept in a convective electrical oven, which was maintained at 105±1 C until constant weight has reached. The initial and final mass, M, and final mass, M of the samples were recorded with the help of electronic balance. The moisture content,m, on wet basis was calculated by using Eq. (1). The procedure was repeated for every one hour interval till the end of drying. M = ( ) 100 (1)

444 N. Harish Kumar et al 2.4. Determination of drying rate The drying rate, DR, should be proportional to the differences in the moisture content between materials to be dried and the equilibrium moisture content [16]. The concept of thin layer drying was assumed for the experiments as reported by Eq. (2). DR = K ( M M ) (2) 2.5. Determination of specific moisture extraction rate The specific moisture extraction rate, which is the energy required for removing one kg of water. SMER was calculated using Eq. (3) as reported by Shanmugam and Natrajan [11] SMER = (3) 3. Results and Discussions The variations of temperature of air at solar collector outlet and ambient temperature for a typical day during of copra are shown in Fig.2. The average drying air temperature recorded at inlet of the drier inlet were measured to be about 46.2 and 34 C during peak and off sun sunshine hours respectively. Figure 2: Variation of Ambient and Drier Outlet Temperature against drying time.

Experimental & Analytical Investigation on Modified Solar Dryer 445 Figure 3: Variation of Solar intensity against Drying time. Figure 3 and 4 shows the variation of solar intensity and ambient relative humidity during experimentation. Maximum solar intensity recorded was about 520 W/m² during peak sunshine hours. The average dry and wet bulb temperatures recorded were 30 C and 26 C respectively. Figure 4: Variation of Relative Humidity against Drying Time. The variation of moisture content (wet basis) with drying time illustrated in Fig.5. The average about 80% to 10.6% and 11% in bottom and top tray respectively after 24hour.The higher moisture reduction during initial stages of drying was observed due to evaporation of free moisture from the outer surface layers and then gets reduced due to internal moisture migration from thinner layers to surface,which results in a process

446 N. Harish Kumar et al of dehydration. The reduction in moisture content at bottom tray was about 4 to 6% higher than that of top tray. Temperature inside drier was higher than ambient temperature and corresponding relative humidity in the drier was lower than ambient relative humidity. As a result, drying rate of grapes in a force convection drier was found to be higher than that of open sun drying. Figure 5: Variation of Drying rate against Drying Time. The specific moisture extraction rate was estimated to be about 0.87 kg/kwh.use of solar drier with the integration of heat storage materials will improves the efficiency of the drier and reduces the dependency of conventional energy sources, which reduces indirect global warming. 4. Conclusion The performance of an indirect forced convection solar drier integrated with recirculation of air was designed, fabricated and investigated for grapes drying. The drier with copper absorber plate enables to maintain consistent air temperature inside the drier. The grapes was dried from initial moisture content 80% to the final moisture content about 10.6% and 11%(wet basis) in bottom and top tray respectively. It could be concluded that, forced convection solar drier is more suitable for producing high quality dried grapes for small holders. Thermal efficiency of the solar drier was estimated to be about 20.92% with specific moisture extraction rate about 0.87 kg/kwh.

Experimental & Analytical Investigation on Modified Solar Dryer 447 References [1] Jain, D.; and Tiwari, G.N (2003).Thermal aspects of open sun drying of various crops. Energy, 28(1), 37-54. [2] Ong, K.S. (1999).Solar dryers in the Asia pacific region. Renewable Energy, 16(1-4), 779-784. [3] Pangavhane, D.R.; and Sawhney, R.L. (2002). Review of research and development work on solar driers for grape drying. Energy conversion and management, 43(1), 45-61. [4] Sodha, M.S.; Dang, A.; Bansal, P. K.; and Sharma, S.B.(1985). An analytical and experimental study of open sun drying and a cabinet type dryer. Energy Conversion Management, 25(3), 263-271. [5] Midilli, A. (2001). Determination of pistachio drying behaviour and conditions in a solar drying systems. International Journal of Research, 25(8) 715-725. [6] Shanmugam, V,; and Natarajan, E. (2007). Experimental study of regenerative desiccant integrated solar dryer with and without reflective mirror. Applied Thermal Engineering, 27(8-9), 1543-1551. [7] Hawlader, M.N.A.; Uddin, M.S.; and Khin, M.M. (2003). Microencapsulated PCM thermal energy storage system. Applied Energy, 74(1-2), 195-202. [8] Ahmad, A.; Saini, J.S.; and Varma, H.K. (1996).thermodynamic performance of packed bed solar air heaters. Energy Conversion and Management 37(2), 205-214. [9] Hegazy, A.A. (1999). Optimum channel geometry for solar air heaters of conventional design and constant flow operation. Energy Conversion and Management, 40(7), 754-774.

448 N. Harish Kumar et al