I ntroduction. Series F61. Liquid Flow Switches. Feature and Benefits

Similar documents
Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available

Series A28 Two stage Thermostats. Feature and Benefits

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

270XT Freeze Protection, IP30

F261 Series Fluid Flow Switches

FS80-C Flow Switch. Features and Benefits. Allows user select the setting according the needs of system

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

Electro Controls. Flow WattsIndustries.co.uk

Flow Switches. Liquid Flow Switches. Mounting Methods

A99B Series Temperature Sensors

Flow Switches. Liquid Flow Switches. Mounting Methods

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

V48 Series 3-Way Water Regulating Valves For Cooling Tower Systems

MR3CCUHV Temperature/Defrost Control

! WARNING. Before using product, read and understand instructions.

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

W43A Humidistat. Features and Benefits

TM-3100 Series Room Temperature Sensor

! WARNING. Before using product, read and understand instructions.

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Differential pressure gauge with electrical contact type Model: P650 series

INSTRUCTION MANUAL MM-601REVI. Series FS4-3 General Purpose Liquid Flow Switch

13-1. Temperature Regulator

! WARNING. Before using product, read and understand instructions.

INSTALLATION INSTRUCTIONS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

quick response ordinary hazard dry hsw sprinklers (8.0K) (VK275, VK277, & VK279)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

STARBOX - CONDENSER UNITS

1592P01. for liquids in piping DN

Comfort. Description. Applications

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

IMMERSION HEATERS IMMERSION HEATERS FOR WATER 1½ BRASS NIPPLE, 3X400V: 2 BRASS NIPPLE, 3X400V:

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

Thermostats type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

INSTRUCTION MANUAL MM-615E. Series FS1 High Sensitivity Liquid Flow Switch

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Water-Cooled Dual Compressor Screw Chiller

Location Requirements

P266 Series Single-Phase Condenser Fan Speed Control

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

MS4PMUHVT Multi-Stage Electronic Temperature Control with Relay Pack

A19, A28 Series Thermostats for Agricultural Buildings

Thermostat KPU. Data sheet

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

standard response dry horizontal sidewall sprinklers

Commercial/Industrial Combustion Control Level Three Announcement

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

CHECK VALVES INSTALLATION

standard response dry horizontal sidewall sprinklers

V246 Series Two-Way Pressure-Actuated Water-Regulating Valves for High-Pressure Refrigerants

HBTS Temperature Sensor For temperature measurement in refrigeration systems

standard response dry horizontal sidewall sprinklers

LC1350 Level Controller

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

When ordering, please state type and code number. Max. Type - Capillary sensor of tube temp. charge length. C m

13.2 Component Illustrations, Parts Lists, and Part Numbers

ACT2-CS Convenience Store Controller

AIC Brazed Plate Heat Exchanger Operating and Instruction Manual

200W Frostwatch Radiant Heater Operation Manual

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Sintrol Snifter A1+ Manual. Version 1.2.2

A-4400 Series Refrigerated Air Dryers for Pneumatic Control Systems

BC3250. Blowdown Controller

T7079A,B Solid State Remote Temperature Controllers

THERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC

ELECTRIC WATER HEATER INSTALLATION & OPERATING INSTRUCTION MANUAL

TEMPERATURE SENSORS FOR OUTDOOR USAGE 08.12a

CATALOG OF REPLACEMENT PARTS

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Installation Instructions

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

FREEDOM RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK480 TECHNICAL DATA

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Flat Line Spray Systems Kits

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

Hydronic Product & Application Catalog

HERZ Differential Pressure Control Valve 4002

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

kw COOLING kw HEATING

INSTALLATION INSTRUCTIONS

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

INSTALLATION USE AND MAINTENANCE MANUAL. ATC Evolution ATC EVOLUTION. Class I - IP55 INFRARED HEATER ATC ELECTRICAL & MECHANICAL

Brasch Hazardous Location Unit Heaters

Switch Basics and Applications

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

A B A B4

Transcription:

PSC9720 European Refrigeration Controls Catalogue Catalog Section 3 Product Bulletin F61 Series F61 Liquid Flow Switches I ntroduction The F61 liquid flow switches can be used in liquid lines carrying water, sea water, swimming pool water, ethylene glycol or other liquids not harmful to the specified materials. The switches have SPDT contacts and can be wired to energise one device and de-energise another device powered from the same source when liquid flow either exceeds or drops below the set flow rate. There are two different models available. The pipe insert models and the T- body types for low-flow applications. All materials in contact with the liquid are specified in the part specifications. At doubt about the liquid used with regards to these materials it is advised to contact the liquid supplier. The IP43 versions can be used for liquid temperatures above dewpoint while the vapour proof IP67 versions can be used for liquid temperatures of minus 30 C and up or in high moisture environments. Typical applications are to shut down the compressor on liquid chiller systems, to prove flow on electric immersion heaters and to give a signal or alarm when the pump on condenser cooling system shuts down. F61 Liquid Flow Switches Feature and Benefits T-body and Pipe-insert types available Polycarbonate IP43 enclosure Vapour tight IP 67 enclosure Stainless steel Pipe-insert type Large wiring space Range screw easy accessible For low flow applications ( 0.04 dm 3 /s) up to flows of 48 dm 3 /s For indoor and outdoor applications. For low temperature applications. Used for liquids like swimming pool water Makes wiring convenient and easily accessible Easy to adjust in the field 1997 Johnson Controls Inc. Catalogue Section 3

2 F61 N ote These controls are designed for use only as operating controls. Where an operating control failure would result in personal injury or loss of property, it is the responsibility of the installer to add devices or systems that protect against, or warn of, control failure.! Caution Do not use with hazardous fluids or in hazardous atmosphere I nstallation Pipe-insert types To allow the switch to detect changes in the liquid flow, the paddle must not touch the pipe or any other obstacle in the pipe. The Pipeinsert types are mounted on top of the liquid line. An angle of 120 is allowed as indicated in Fig. 1. To keep the flow switch close to the pipe and to provide an adequate paddle length in the flow stream the use of a reducing tee for larger pipe sizes is advised. The arrow on the cover must point in the flow direction. To avoid turbulence it is advised to mount the controller at a distance of minimal 10xD (on each side) away from elbows, valves and other appendages. The Pipe-insert types can be mounted in a vertical pipe as long as the flow is up-stream. This mounting position affects the adjustment of the controller. The 6 paddle can be trimmed as indicated on page 6. For added stiffness it is advised to mount the smaller paddles behind the largest one. Fig1 T-body types These types are mounted in the liquid line with the housing at the top. An angle of 120 is allowed as indicated in Fig. 1. The arrow on the body and cover must point in the flow direction. To avoid turbulences it is advised to mount the controller at a distance of minimal 10xD (on each side) away from elbows, valves and other appendages. The T-body types cannot be mounted in a vertical pipe. W iring A special vapour proof PG-16 nipple for cable inlet is delivered by the IP67 type controls. This nipple has to be used to keep the control vapour tight. Contact function 2 3 > 1 Fig. 2 1-3 closes on flow increase. Catalogue Section 3 1997 Johnson Controls Inc.

F61 A djustment The switches are factory set at minimal flow setting. On the application the setting can be adjusted by the range screw under the cover as indicated in fig. 3. For higher flow rates turn the adjusting screw clockwise. N ote Prevent to adjust the setting below factory setting as this may result in the switch failing to return to no flow position. Flow rates T-body Types [kpa] Pressure drop 140 120 100 80 60 40 20 0 0 0.3 0.6 0.90 1.2 1.5 1.8 Flow rate 1 /2" Types [dm 3 /s] 3 /4" Types 3 Fig. 4 Pressure drop Pipe Insert Types 16 15 14 13 12 1" pipe [kpa] 11 10 Fig. 3 Flow rates Note : Please note that these curves are approximate data obtained in a laboratory test by use of water and are not necessarily representative or accurate when compared with various field applications. Values are affected by the liquid used and the mounting position of the controller. Flow rates for pipe sizes 3 and up are calculated values. Pressure drop 9 8 7 6 5 4 3 2 1 1 1 /2" pipe 1 1 /4" pipe (using paddle for 1" pipe) 2" pipe 2 1 /2" pipe 3" pipe 0 0 1 2 3 4 5 6 7 Flow rate [dm 3 /s] Fig. 5 1997 Johnson Controls Inc. Catalogue Section 3

4 F61 Flow rate table Pipe Insert Types Paddle size Line pipe size 1" 1 1 /4" 1 1 /2" 2" 2 1 /2" 3" * 4" * 5 * 6" * 8" * Minimum Flow 1"-2"-3" dm 3 /s 0.3 0.4 0.5 0.9 1.1 1.7 4.2 7.8 12 24 adjustment increase (m 3 /h) (1.0) (1.3) (1.7) (3.1) (4.1) (6.2) (15) (28) (43) (85) 1-3 closes 6" dm 3 /s - - - - - - 2.4 # 3.6 # 4.8 13 (m 3 /h) - - - - - - (8.5) # (13) # (17) (47) Flow 1"-2"-3" dm 3 /s 0.15 0.2 0.3 0.6 0.8 1.2 3 6.4 10 20 decrease (m 3 /h) (0.6) (0.8) (1.1) (2.2) (2.8) (4.3) (11) (23) (36) (73) 1-2 closes 6" dm 3 /s - - - - - - 1.7 # 2.5 # 3.4 11 (m 3 /h) - - - - - - (6) # (9) # (12) (39) Maximum Flow 1"-2"-3" dm 3 /s 0.6 0.9 1.2 1.8 2.2 3.4 8.1 16 24 48 adjustment increase (m 3 /h) (2.0) (3.0) (4.4) (6.6) (7.8) (12) (29) (56) (85) (173) 1-3 closes 6" dm 3 /s - - - - - - 5.0 # 7.6 # 9.2 26 (m 3 /h) - - - - - - (18) # (27) # (33) (94) Flow 1"-2"-3" dm 3 /s 0.5 0.8 1.1 1.7 2.0 3.2 7.8 1"5 23 43 decrease (m 3 /h) (1.9) (2.8) (4.1) (6.1) (7.3) (11.4) (28) (53) (82) (116) 1-2 closes 6" dm 3 /s - - - - - - 4.8 # 7 # 8.7 25 (m 3 /h) - - - - - - (17) # (25) # (31) (91) 1 dm 3 /s = 3.6 m 3 /h = 15.6 U.S. gal./min. = 13 U.K. gal./min. * Flow rates for these sizes are calculated. # For 4" and 5" line pipe the 6" paddle is trimmed Accessories for Pipe-insert types KIT21A600 :1, 2, 3 paddle, phosphor bronze KIT21A601 KIT21A602 : 6 paddle, phosphor bronze :1, 2, 3 and 6 paddles stainless steel AISI 301 R epair and replacement Repair is not possible. In case of an improperly functioning control, please check with your nearest supplier. When contacting the supplier for a replacement you should state the type/model number of the control. This number can be found on the data plate or cover label. Catalogue Section 3 1997 Johnson Controls Inc.

F61 Type number selection table Pipe-insert Range Connection IP Paddles Paddles Paddles Application dm 3 /sec. class phosphor br. st. st AISI 301 st. st AISI 304 ASTM B103 F61SB-9100 0.15/46 R1"DIN2999(ISO R7) IP43 1", 2", 3" Water/Ethylene glycol F61SB-9103 0.15/46 R1"DIN2999(ISO R7) IP43 1", 2", 3" 6" Water/Ethylene glycol 5 F61TB-9100 0.15/46 1-111/2 NPT IP67 1", 2", 3" 6" Brine, sea water F61TB-9102 0.15/46 1-111/2 NPT IP67 1", 2", 3", 6 Brine, sea water F61TB-9103 0.15/46 R1"DIN2999(ISO R7) IP67 1", 2", 3" 6" Water/Ethylene glycol F61TB-9200 0.15/46 R1"DIN2999(ISO R7) IP67 1", 2", 3" Sea water, swimming pool water T-Body Range Connection IP Application dm 3 /sec. class F61SD-9150 0.04/0.07 1/2-14 NPTF IP43 Water/Ethylene glycol F61SD-9151 0.08/0.11 1/2-14 NPTF IP43 Water/Ethylene glycol F61SD-9175 0.04/0.07 3/4-14 NPTF IP43 Water/Ethylene glycol F61TD-9150 0.04/0.07 1/2-14 NPTF IP67 Water/Ethylene glycol Note : Paddles not mounted, packed with the control. D imensions 100 60 A B 60 38 121 17 59 38 mm Hex Fig. 6 F61SD/TD A. Cable inlet hole ø 22.3 mm; Grommet installed on IP43 types. B. Vapour proof PG-16 nipple delivered with IP67 types 1997 Johnson Controls Inc. Catalogue Section 3

6 F61 D imensions 100 60 A B 45 30 115 C 6" 5" 4" 3" 2½" 2" 1" 33 17 25 54 Body -9200 models 1½" 1¼" 162 6 134 107 83 67 43 54 29 37 D Fig. 7 F61SB/TB A. Cable inlet hole Ø 22.3 mm; grommet is installed on IP43 types. B. Vapour proof PG-nipple delivered with IP67 types. C. 30 mm Hex. F61SB/TB 45 mm F61TB-9200 D. 1 paddel D = 25mm 2, 3, 6 paddel D = 29 mm 3 1996 Johnson Controls Inc.

F61 7 N ote 1996 Johnson Controls Inc. 3

8 F61 S pecifications Pipe Insert Types T-body Types Type number F61SB-9100 F61SB-9103 F61TB-9100 F61TB-9102 F61TB-9103 F61TB-9200 F61SD-91xx F61TD-9150 Flow Rates see selection table Pipe connection see selection table Max liquid pressure 10 bar 10 bar 10 bar 10 bar 10 bar 10 bar Max. liquid temp.* 100 C 100 C 100 C 100 C 100 C 100 C Min. liquid temp.** 0 C -30 C -30 C -30 C 0 C -30 C Max. ambient temp.* +55 C +55 C +55 C +55 C +55 C +55 C Min. ambient temp.** -40 C -40 C -40 C -40 C -40 C -40 C Ambient humidity 10-95% 10-95% 10-95% 10-95% 10-95% 10-95% Contact type SPDT snap-acting switch Electrical rating 15(8) A 230Vac Wiring connections screw terminals 1 up to 2.5mm 2 Enclosure IP43 IP67 IP67 IP67 IP43 IP67 Vapour proof Vapour proof Vapour proof Vapour proof Materials Polycarbonate cover / case Materials in contact with liquid Paddles see selection table Bellows phosphor bronze CuSn 6 phosphor bronze CuSn 6 phosphor bronze CuSn 6 stainless steel AISI 316L DIN1.4404 phosphor bronze phosphor bronze Rod Body Bellows washer Body washer CuZn36Pb1.5 CuZn40Pb2 CuZn36Pb1.5 nickel plated ASTM B584 alloy C84400 nickel plated CuZn36Pb1.5 CuZn40Pb2 stainless steel AISI 316L DIN1.4401 stainless steel AISI 316 DIN1.4401 Screw paddle conn. ¼ hard silicon bronze ¼ hard stainless steel AISI 316 DIN1.4401 Washer paddle phosphor bronze phosphor bronze phosphor bronze stainless steel conn. AISI 316 DIN1.4401 bronze ASTM B140 alloy 316 ASTM B584 alloy C84400 red phosphor bronze ASTM B103 alloy AI ¼ hard bronze ASTM B140 alloy 316 ASTM B584 alloy C84400 ASTM B36 alloy 3 phosphor bronze ASTM B103 alloy AI ¼ hard Seat red red ½ hard ½ hard Silver solder L-Ag45 L-Ag45 SN50Pb SN50Pb Softsolder L-SnAg5 L-SnAg5 L-SnAg5 Ag 15 P Ag 15 P Shipping weight individual pack 0.7 kg 0.7 kg 0.7 kg 1.0 kg 1.0 kg 1.0 kg overbox 15 kg (24 pcs) 15 kg (24 pcs) 15 kg (24 pcs) 22 kg (24 pcs) 22 kg (24 pcs) 22 kg (24 pcs) Vibration acc.to DIN 89011 Kennlinie I * The max. liquid temperature of 100 C is at 20 C ambient. At higher ambient temperatures the max. allowed liquid temp. becomes lower. The temperature of the electrical switch inside should not exceed 70 C. ** The low liquid temperature combined with a low ambient temp.should not lead to freezing of the liquid inside the body / bellows. Please observe the liquid freezing point. The performance specifications are nominal and conform to acceptable industry standards. For applications at conditions beyond these specifications, consult the local Johnson Controls office or representative. Johnson Controls shall not be liable for damages resulting from misapplication or misuse of its products. Johnson Controls International, Inc. Headquarters: Milwaukee, WI, USA European Headquarters: Westendhof 8, 45143 Essen, Germany European Factories: Lomagna (Italy), Leeuwarden (The Netherlands) and Essen (Germany) Branch Offices: Principal European Cities. This document is subject to change Printed in Europ 3 1996 Johnson Controls Inc.