MD12-1 Vehicle Loop Detector

Similar documents
MD12-2 Vehicle Loop Detector

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

Operating Instructions

Operating Instructions

Operating Instructions

For more information, please visit or call toll free at

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Operating Instructions

Eclipse MC240. Double & Single Gate Controller with Eclipse Operating System (EOS) 3rd Edition. MC240 for Double and Single Gates.

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

D-TEK -MS Vehicle Loop Detector. Operating Instructions

SPACEMOTION SERIES SMM 01

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Installation, Operating and Maintenance Manual

ENGINEERED PARKING SYSTEMS MODEL 3416D

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

DUAL MONITORED INPUT/OUTPUT UNIT BN-305-2

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

Carbon Monoxide Transmitter

AED Alarm System Model Operations Manual

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

MTRA-FSP Level Control Relay. Installation & Operation Manual

SMARTWALK DEMENTIA WANDERING SYSTEM

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

FEC400 Series. Installation Manual

Operations Manual. Motion Detector Module Model ZS10

GRUNDFOS INSTRUCTIONS LCD 108. Installation and operating instructions

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

TBR 40 1 GD Blood Refrigerator Instruction Manual. for BLOOD STORAGE REFRIGERATORS MODEL TBR 40 1 GD. (40 x 500ml Blood Bag Capacity)

Product Manual SZ1145

B-40/B-41 Modulating Temperature Controller

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Operation and Maintenance Manual

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Product Manual SZ1144

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

LUX Hardwired - Installation Notes

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

Quick Reference Guide. Application. Gas Furnaces Boilers Water Heaters Commercial Cooking. Features

Conventional Fire Alarm System 2014 V1.2

Installation and Operation Manual. Model Q916

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Greentrol Automation, Inc.

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

GAS SUPRESSION CONTROL PANEL:

24 VAC Intermittent Pilot Gas Ignition Control

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

ESP TECHNOLOGIES LIMITED

EC Series Wall Unit Humidifier

USER MANUAL FOR OPERATING SYSTEM

232xt Wiring Diagrams and Specifications SPECIFICATIONS: REV 1.01

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

M2500 Engine Controller Installation Manual

OPERATION AND INSTALLATION MANUAL

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

SENTINEL A - Fault Passage Indicator

QA16 Addressable System

Reflective Optical Beam Smoke Detector User Guide

IEI NETWORK INTERFACE MODEL TS2040

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Installation, Operation, and Troubleshooting Instructions

HX-80NRAM. High Mount Outdoor Detector

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

CHECKFIRE 110 DETECTION AND ACTUATION SYSTEM

Heat Pump Defrost Board Replacement Kit

R A D I O N I C S. READYKEY K2015A Alarm Event Manager. Installation Data Sheet. Description

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Oxygen (O2) Single-Point Gas Detection System

DSP-13 Tri-Axis Detection (TRIAD TM ) System

CONTROL DEVICE SLIDETRONIC HD

DIGITAL ALARM UNIT Model ALU-AP

SET-2000 Hi Level/Oil

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

OPERATION / INSTALLATION

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Pioneer-R16 Gas Monitor Operator s Manual

SAFETY INFORMATION AND WARNINGS

Universal Gas Detector

Transcription:

MD12-1 Vehicle Loop Detector Features Supply 12VDC Adjustable sensitivity (16 levels via a trimpot) 2 x Relay outputs (each can be configured individually) Power up and loop activation LED indicator. Industry standard 11-way plug-in type circular connector. ELSEMA Application Controls automatic doors or gates when a vehicle is present source. Description Loop detectors in recent years have become a popular tool having innumerable applications in policing, right from surveillance operations to traffic control. Automation of gates and doors has become a popular usage of the loop detector. The digital technology of the loop detector enables the equipment to sense a change in the inductance of the loop as soon as it detects the metal object in its path. The inductive loop which detects the object is made of insulated electrical wire (32/020; 32 Strand, 2mm diameter) and is arranged either as a square or rectangle shape. The loop consists of several loops of wire and consideration should be giving to the loop sensitivity when installing on different surfaces. Setting the correct sensitivity allows the loop to operate with maximum detection (16 levels via a trimpot). When detection occurs, the detector energises 2 relays for the output (each can be configured individually). This energising of the relay can be configured into different modes, by selecting the respective dip switch. Technical Data Supply voltage Standby Current Operating Current Outputs Connection 12VDC 58 ma 64 ma 2 changeover relays rated at 240VAC, 3A Screw type terminal - 1 -

Connections ELSEMA Pin Type 1 12VDC+ 2 12VDC- 3 Relay B, (NO) 4 Relay B, (COM) 5 Relay A, (NO) 6 Relay A,(COM) 7 Loop 8 Loop 9 Earth 10 Relay A, (NC) 11 Relay B, (NC) Switch 1 (Trimpot), Sensitivity Selection Sensitivity of the loop can be adjusted by the trimpot labeled Sensitivity. User can select 16 different setting by turning the trimpot with 0 being the least sensitive and F being the most sensitive. Switch 2 (Dipswitch Settings) Dip switch Settings 1 and 2 Special Functions Function Dip switch 1 is ON Output has 2 seconds delay. (No relay output if the vehicle speed is over 8km/h). Dip switch 2 is ON Increase sensitivity to avoid unwilling relay off for leaving vehicle especially for trailer. - 2 -

ELSEMA Dip switch 3 and 4 is OFF Dip switch Settings 3 and 4 Relay B Output Function When vehicle is moving out, output for relay B is 200m/s. Dip switch 3 ON When the vehicle has left, output for relay B is 600m/s. Dip switch 4 ON Relay B will be present output. No reaction on Dip switches 3. Dip switch 3 and 4 ON Can be used to test the Loop. If the loop is faulty, Relay B will be on and it will switch off once the fault is fixed. Dip switch Settings Automatic Reset Present Mode Dip switch 5 ON Dip switch 5 OFF Vehicle can be permanently present (no auto-reset, unless vehicle has left or manual reset) Normal mode (automatic reset after 10minutes present of vehicle, used to solve the mistake operation. If it is recommended). Dip switch Setting 6, 7 and 8 Delay Vehicle Present Relay A Delay Dip switch 6,7 and 8 is OFF 0 sec Relay A output Dip switch 6 ON 2 sec Relay A output Dip switch 7 ON 5 sec Relay A output Dip switch 6 and 7 ON 8 sec Relay A output - 3 -

ELSEMA Dip switch 8 ON 10 sec Relay A output Dip switch 6 and 8 ON 15 sec Relay A output Dip switch 7 and 8 ON 20 sec Relay A output Dip switch 6,7 and 8 ON 30 sec Relay A output Dip switch Settings 9 and 10 Frequency Frequency (30 K to 100 KHz). Used to avoid the interference Dip switch 9 and 10 OFF High Dip switch 9 ON Dip switch 10 ON Medium-High Medium-Low Dip switch 9 and 10 ON Low Setup Instructions Power Led RED power LED indicates Power ON Detecting Led Continuously On: Indicates vehicle detection. Blinking slowly: Indicates loop is short circuit or the number of twists after the loop is not enough. Blinking fast: Indicates loop is open circuit or too many twists after the loop. Operation Panel and switches Power : Red Led Detect : Green Led If it is fully lit, power is supplied. If it is fully lit, a vehicle is detected. If the led blinks, then the loop is faulty. - 4 -

Sensitivity Selection ELSEMA Low sensitivity Range High sensitivity Range From 0 to 9, with 0 begin the lowest From A to F, with F begin the highest Sensitivity Selection * In the application, where two or more loop detectors and sensing loops have been installed, set one detector to high frequency and the other set to low frequency to minimize the effects of cross-talk between the two systems (The sensing loops and detectors should be positioned at least 2m apart). Reset Button: Please note: The MD12-1 must be reset every time a setting change is made to the Dip switches. - 5 -

ELSEMA LOOP Elsema stocks pre-made loops for easy installation. Our pre-made loops are suitable for all types of installations. Either for cut-in, concrete pour or direct hot asphalt overlay. see www.elsema.com/auto/loopdetector.htm Detector position and installation Install the detector in a weatherproof housing. The detector should be as close to the sensing loop as possible. The detector should always be installed away from strong magnetic fields. Avoid running high voltage wires near the loop detectors. Do not install the detector on vibrating objects. When the control box is installed within 10 metres of the loop, normal wires can be used to connect the control box to the loop. More than 10 metres requires the use of a 2 core shielded cable. Do not exceed 30 metres distance between control box and loop. Troubleshooting Symptoms If the detector is not working If red led indicator is not fully lit If green led indicator: If no: of turns is not enough If no: of turns is too many Blinks slowly Blinks faster Press reset Check for power supply Solution It maybe because the loop is short circuit or the no: of turns is not enough. It maybe because the loop is open or the no: of turns is too many. Lower the frequency (if the frequency is still too high, you must add more turns). Higher the frequency (if the frequency is still too low, you must remove some turns). Manufactured by Distributed by Elsema Pty Ltd 31 Tarlington Place, Smithfield NSW 2164, Australia Ph: 02 9609 4668 Fax: 02 9725 2663 Website: http://www.elsema.com - 6 -