ELITE-600 DENTAL PORCELAN FURNACE

Similar documents
Focus 4010\ Focus 4010 HT porcelain firing furnace

IMAGE PRESS & IMAGE PORCELAIN OVEN. 120V, 50/60 Hz Models and 230V, 50/60 Hz Models. Operator s Manual

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

REC-8R Environmental Control. Operation and Installation Manual

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

WHA 3000P Hot Air Station

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

USER S MANUAL FOR DENTAL CERAMIC FURNACE DCF User s Manual for Dental Ceramic Furnace DCF-1200

Autofire Express Ramp/Hold Controller Instruction Guide

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Operating Manual. for. SMD/BGA Rework System IR860

OPERATING INSTRUCTIONS

AFA 500 FUME HOOD ALARMS

54 Howleys Road Notting Hill 3168 Victoria Australia Telephone: Fax:

Table 1. Serie of Digital Room Thermostats.

EasyTronic III MANUAL SERVICE

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

OPERATING MANUAL. EchoThermJ DIGITAL HOT PLATE MODEL HP30 AND HP30A. DOCUMENT NUMBER HP30-03 Revised 10 December 2011

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

Electronic Pellet Burner Controller NPBC-V3M

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS MD5-601 AND MD5-603

Model: Touch-RS. 1 Touch-RS

Wireless Keypads LKP(E)S8M Series

CG Series Digital Temperature Controller OPERATIONS MANUAL

Programmable Muffle Furnace Instruction Manual Series

Electronic Pellet Burner Controller NPBC-V3-1

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

HA06. User manual. (SDO Hot Air One) HOT AIR / QUARTZ REFLOW OVEN. Version 2.21

Technical Manual. Level Alarm Unit CARLA & WIDS

Smart Temp. Model

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

DC200 Digital Dispenser Operating Manual

AXI LED USER MANUAL (REV. 1.0)

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

Alarm Tone Generator Model AG17

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Mark 25 Ultrapure Water Conductivity Analyzer

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT HCT-1000 User Guide

ISO-9001:2008 FURNACES CATALOG. Phone: Fax: Web:

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

Table of Contents SECTION PAGE

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Small in size, with grand features USER GUIDE Elle-même petite, mais avec caractéristique grand

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

ETN-24-SUPER-PROG (US Program - Celsius)

Modbus RTU RS485 Manual

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Application Manual Loop Water Controller

PF1000 CONTROLLER. for the. Heateflex Corporation 405 E. Santa Clara St. Arcadia, CA TEL: (626) ; FAX: (626)

Laptop / PC Programming Manual

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Cm Pelet-set (60-90 kw)

Model: Touch-RF. 1 Wireless Series

DT6500 CONTROLLER. for the ICD PART #: ICD SERIAL #: 1714

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

OPERATING MANUAL MOLECULAR DIMENSIONS, INC. DIGITAL CHILLING INCUBATOR MODELS MD5-600, MD5-602, AND MD5-604

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

534I, 650, 739I, 1200, 1300, 1500, MF28I

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

Version 1.03 January-2002 USER S MANUAL

ELECTRONIC COMMUNICATING THERMOSTAT

Wireless Keypad GKP-S8M

Process & TeMPerATUre UniversAl input DigiTAl MeTers

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

QA16 Addressable System

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Cm Pelet-set TECHNICAL INSTRUCTIONS FOR THE COMMISSIONING AND ADJUSTMENT. (14-35 kw) For boilers: EKO-CKB P (EKO-CKB 20-40)

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

Desoldering Tool. (HAKKO FR-4102) Instruction Manual. Table of Contents

TC515 and TC600 Installation Manual. a Winters company

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number:

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

TIF9055 Programmable. Owner s Manual Manual del Propietario Manuel du propriétaire Benutzerhandbuch Manuale del proprietario

DIGITAL LIGHT CONTROLLER

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

4L & PRO PROVIDER MATERIALS

Gas Detection System TOX ALARM DG2000-Garage

Oakton TEMP 9500 Advanced Multiparameter Controller

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

WHA 3000V Hot Air Station

ETN-24-SUPER-SF Series

MiLAB Oxygen Control MANUAL & INSTALLATION. MOC-100 Ver 3.0

Transcription:

ELITE-600 DENTAL PORCELAN FURNACE USER MANUAL

CONTENTS Introduction. 2 Specifications 3 Description of the furnace 4 General. 5 Controls 5 display 5 Data display.. 5 Vacuum display... 5 Parameter leds.. 5 Push-buttons. 5 Audio feedback 6 Operation manual Stand-by mode 6 mode 6 Parameter mode.. 6 Correlation between parameters. 7 timer. 8 Baking cycle 8 Two-stage baking 9 Two-stage cooling.. 9 Postfiring 9 Built-in illumination lamp.. 10 Automatic night program 10 Calibration.. 11 Self tests.. 12 Protection 13 Baking programs. 14 Rev. 1-1 - 1-12/10

INTRODUCTION Vacuum porcelain furnace ELITE-600 that you have purchased is the newest and the most advanced vacuum porcelain furnace. This state of the art furnace makes possible to achieve the best results with any kind of modern porcelain materials and ensures unmatched flexibility of baking process. Microcomputer based electronics and other achievements of modern furnace technology leaded to versatile, reliable, high performance and low cost design. Modern advanced porcelain materials present new challenges to dental porcelain furnaces and ELITE-600 was designed to meet these challenges. Unique features implemented in this new furnace turn dreams to reality. Innovative two-stage baking and two-stage cooling combined with approved 12-parameters baking and postfiring program enable unmatched flexibility and best fit for any kind of existing porcelains as well as for new porcelains being developed in the future. Some of impressive features of the furnace are listed below: 100ºC (570ºF) to 1200ºC (2200ºF) operational range NEW! 200 fully adjustable baking programs 2 idle programs (Day and Night) Automatic Night program Calibration and purge programs NEW! 2-stage baking (first baking stage at BAKING. TEMP., additional baking stage at FINAL TEMP.) NEW! 2-stage cooling (slow cooling inside the muffle + fast cooling during work plate descend) Postfiring programs 13 programmable firing parameters Permanent monitoring of current baking stage Manual overrun function for immediate start of baking program Vacuum level display NEW! Built-in lamp for working area illumination Power failure and power line disturbance protection Vacuum level control Digital display of vacuum level Non-battery user program storage NEW! Built-in serial port for printer connection. Built-in self test capability (muffle, thermocouple, vacuum system, memory etc.) Easy and clear operation Power failure and power line disturbance protection 220-240V/50Hz, 100-120V/60Hz power input 24 months warranty on parts and workmanship including muffle Rev. 1-1 - 2-12/10

SPECIFICATIONS Number of baking programs - 200 Number of idle programs - 2 Overall dimensions: - 27cm (10.5") W x 32cm (12.5") D x 50cm (20") H Net weight - 15 Kg (34 1bs.) Electrical - 115V 50/60Hz - 1700 W 230V 50/60Hz - 1700W Rev. 1-1 - 3-12/10

DESCRIPTION OF THE FURNACE 1. GENERAL. a. The furnace consists of main module and muffle module. b. The main module contains power supply, computerized control module, front panel and mechanical assembly with work plate. c. The muffle module contains vacuum chamber, muffle, fan and built-in lamp for working area illumination. 2. CONTROLS. a. The furnace controls are placed on the front panel and on the rear panel. b. Front panel: 1. display. 2. Data display. 3. Vacuum display. 4. Function buttons. 5. Data buttons. 6. Control buttons. c. Rear panel: 1. Power switch. 2. Pump fuse. 3. Muffle fuse. 4. Power cord receptacle. 5. Pump cord receptacle. 6. RS232 serial port (optional) d. Right side: 1. Calibration plate receptacle. 3. PROGRAM DISPLAY. a. Contains 3-digit numeric field. b. Initially displays the "DAY" program (---). c. Displays selected program number 0-200. 4. DATA DISPLAY. Data display consists of: a. 4-digit numeric field. b. Measurement units field: ºC (ºF) for temperature and min for time. 5. VACUUM DISPLAY. Vacuum display consists of: a. 3-digit numeric field. b. Measurement units field: "/mm for American and European standards. Rev. 1-1 - 4-12/10

6. PARAMETER LEDS. Start temperature - START TEMP Work table rise time - DRY TIME Preheat time inside the muffle at START temperature - PREHEAT TIME Ramp - RAMP Vacuum on temperature - VAC. ON Vacuum level - VAC. LEVEL Hold time with vacuum - VAC. HOLD Vacuum release temperature - VAC. OFF Baking temperature - BAKING TEMP. Hold time at END temperature - TEMP. HOLD Final temperature - FINAL TEMP. Work table exit time - COOL TIME 7. PUSH - BUTTONS. Three groups of push-buttons are placed on the front panel: a. Data buttons: digits 0 to 9, "ENT" and "CLR". b. Function buttons: PROG, PARAM and TIME. c. Control buttons: ON/OFF, UP, DOWN/RESET, START and POSTFIRE. 8. AUDIO FEEDBACK. a. Audio feedback is provided for user comfortability. Single tone means acceptation of pressed button, double tone - rejection. b. Bell warning provided in following cases: 1. End of baking cycle. 2. User memory fault. 3. Muffle fault. 4. Thermocouple fault. 5. Calibration error. 6. Vacuum system fault. 7. Position error. Rev. 1-1 - 5-12/10

OPERATION MANUAL 1. To start operation of the furnace turn the POWER SWITCH on. The device is in STAND- BY mode. 2. STAND-BY MODE. a. The STAND-BY mode is provided for long period waiting. In this mode the muffle is turned off and the work plate stays in its previous position. The OFF led is turned on. NOTE: It is recommended to keep the vacuum chamber closed to prevent muffle moisturizing. b. Press the ON/OFF button for PROGRAM mode selection. The OFF led will turn off and the ON led will turn on. 3. PROGRAM MODE. a. The PROGRAM mode is provided for baking program selection. b. Select program number from 0 to 200. s 0 to 2 are factory set service programs, programs from 3 to 200 are free user programs. c. To correct selected program number, if desired, press the CLR button and return to the previous instruction. d. Press ENT button. e. The muffle temperature is displayed during PROGRAM mode. When the muffle is cold (less then 280 C/530 F), (COLd) message is displayed. f. The muffle temperature is kept at the initial level for selected program (START TEMP.). 4. PARAMETER MODE. a. PARAMETER mode provided for parameter verification and setting. b. Press PARAM button for PARAMETER mode selection. PARAM and START TEMP led will turn on and parameter value will be displayed on the data display. Press PARAM button once more to select the next parameterr, press ENT button to move to another row in the same line of parameter field. c. Set new parameter value, if desired (for programs 3 to 200 only). Data insertion sequence is the same as in the PROGRAM mode. d. Parameter limits table: START TEMP. - From 100ºC C to 1200ºC (210-2200ºF) DRY TIME - From 1 Sec to 45 Min PREHEAT TIME - From 1 Sec to 45 Min RAMP - From 10ºC/Min to 180 C/Min (20 F/Min to 320ºF/Min) VAC. ON - From 100ºC to 1200ºC (210-2200ºF) (Not less than START TEMP.) VAC. LEVEL - From 1 to 760 mm Hg (1-30"Hg) VAC. HOLD - From 1 Sec to 45 Min VAC. OFF - From 100ºC to 1200ºC (210-2200ºF) (Not less than VAC. START) Rev. 1-1 - 6-12/10

BAKING TEMP. - From 100ºC to 1200ºC (210-2200ºF) (Not less than START TEMP. and not less than VAC. OFF) TEMP. HOLD - From 1 Sec to 45 Min. (Not less than VAC. HOLD) FINAL TEMP. - From 100ºC to 1200ºC (210-2200ºF) FINAL TEMP. HOLD - From 1 Sec to 45 Min. COOL TIME - From 1 Sec to 45 Min. NOTE: There is no separate led for FINAL TEMP. HOLD parameter. When you stay at FINAL TEMP. parameter and PARAM button is pressed, both leds TEMP. HOLD and FINAL TEMP. are turned on and FINAL TEMP. HOLD value appears on DATA DISPLAY. You may set or change the value as usual. e. The muffle temperature is kept at the initial level for selected program (START TEMP.). f. Press the PROG button to return to the PROGRAM mode. g. Press the ON/OFF button to get to the STAND-BY mode. h. Use power switch to turn off the furnace. NOTE: For American standard vacuum level value is rounded to 0.5" Hg. resolution automatically. 5. CORRELATION BETWEEN PARAMETERS. a. The following parameters are necessary for normal furnace operation: 1. START TEMP. 2. RAMP. 3. BAKING TEMP. b. If the VAC. ON parameter is set, then VAC. OFF or VAC. HOLD parameter must also be set and vice versa. c. If the VAC. ON parameter is set, then VAC. LEVEL must also be set and vise versa. d. If the VAC. HOLD parameter is set, then TEMP. HOLD parameter must also be set. e. If parameter correlation error occurs, baking cycle will not start and corresponding parameter leds will blink. Rev. 1-1 - 7-12/10

6. PROGRAM TIMER.. a. duration in minutes and seconds is displayed when the TIME button is pressed. The TIME led is turned on. When the button is released, the previous display is returned. b. If program duration can not be evaluated (missing parameters or parameters don't fit), (--'--) is displayed. NOTE: For programs with slow cooling stage (FINAL TEMP. is lower than BAKING TEMP.) calculated program duration doesn't include cooling time from BAKING TEMP. to FINAL TEMP. 7. BAKING CYCLE. a. Press the START button. Baking cycle will not start if parameter correlation error exists. Blinking leds point to problematic parameters. Correct the error and press START button again. b. To start baking cycle the work plate should be in DOWN position. If the work place wasn't in this position, the START led blinks and work plate moves to DOWN position, then START led is turned on and baking cycle begins. c. Baking cycle starts automatically when muffle temperature is equal to the START TEMP. for selected program. d. You may start baking cycle immediately independently of current muffle temperature by pressing START button and holding it pressed for about 1 second. e. Use PARAM button to check parameter values during baking cycle. d. Back running counter is provided for baking cycle. Press the TIME button for timer display. e. Press DOWN/RESET button to interrupt baking cycle if desired. In this case vacuum is released from the chamber, the work plate goes down and the furnace stays in the PROGRAM mode. f. Parameters of selected program may not be changed during baking cycle and other program may not be selected. NOTE: ELITE-600 has several options for vacuum starting: 1. If you want to keep low temperature until vacuum level is reached, you have to set PREHEAT TIME for 40 seconds at least and VAC ON temperature has to be equal to START TEMP. Vacuum pump turns on immediately after chamber is closed and temperature doesn't rise during PREHEAT TIME. 2. If PREHEAT TIME is not set (--'--), temperature will rise simultaneously with vacuum start. 3. If you want to keep air in the chamber during PREHEAT TIME, you have to set VACUUM ON temperature higher that START TEMP (even one degree is enough). In this case, after PREHEAT TIME is over, temperature will rise and vacuum will start at programmed point. Rev. 1-1 - 8-12/10

8. TWO-STAGE BAKING. a. ELITE-600 enable both regular one-stage baking and innovative two-stage baking programs. For one-stage baking set BAKING TEMP. and TEMP. HOLD parameters as required for porcelain you use and leave FINAL TEMP. and FINAL TEMP. HOLD parameters empty. Baking program begins at START TEMP., after DRY TIME and PREHEAT TIME steps temperature is risen to BAKING TEMP. with heat rate defined by RAMP; after reaching BAKING TEMP. the temperature stays at this level during TEMP. HOLD and then the work plate goes down. b. Two-stage baking is a unique feature enabling more flexible porcelain processing. For two-stage baking FINAL TEMP. should be set higher than BAKING TEMP. In this case baking process is performed as follows: Temperature is risen from START TEMP. to BAKING TEMP. with heat rate equal to RAMP.; after reaching BAKING TEMP. the temperature stays at this level during TEMP. HOLD as usual (TEMP. HOLD leds are turned on). When TEMP HOLD. is over the temperature is risen to FINAL TEMP. with the same RAMP.; After reaching FINAL TEMP. the temperature stays stable during FINAL TEMP. HOLD time. After FINAL TEMP. HOLD is over work plate goes down and COOL TIME led is turned on. c. Two stage baking may be useful for special treatments such as post-soldering, etc. 9. TWO-STAGE COOLING. Some kinds of modern porcelains (Shofu, etc.) require two-stage cooling which is easily achieved in ELITE-600. FINAL TEMP. parameter should be set lower than BAKING TEMP. In this case baking is performed as usual until BAKING TEMP. is reached and TEMP. HOLD is over. At this moment the work plate goes down a little to enable slow cooling inside the muffle. The muffle is turned off and the work is cooling slowly until FINAL TEMP. is reached. FINAL TEMP. led is turned on and the temperature stays stable during FINAL TEMP. HOLD time. When it is over the second stage - fast cooling - is performed according to COOL TIME parameter while work plate goes down. NOTE: The time required for slow cooling inside the muffle is not included in overall duration of baking cycle. When temperature decreases from BAKING TEMP. to FINAL TEMP., program timer is holted. Down count is resumed after FINAL TEMP. is reached. 10. POSTFIRING. Postfiring means additional baking without need to wait for furnace cooling. This option is especially important for GLAZE programs if baking temperature of regular program was not high enough. Rev. 1-1 - 9-12/10

Postfiring is performed with accordance to following parameters: Heating rate - RAMP Baking temperature - BAKING TEMP. + P.F. STEP Hold time - TEMP. HOLD Final temperature - FINAL TEMP. + P.F. STEP (for two-stage baking, if FINAL TEMP. > BAKING TEMP.) - FINAL TEMP. (for two-stage cooling, if FINAL TEMP. < BAKING TEMP.) Final hold time - FIN TEMP. HOLD Work plate exit time - COOL TIME When POST FIRE button is pressed, the work table does up immediately without reference to present temperature, and the baking cycle is performed from current temperature. Every additional push on POST FIRE button will cause postfiring cycle. Baking temperature of every consequent postfiring will be higher then the previous one by P.F. STEP. When START button is pressed or new program number is selected, the postfiring counter is cleared and the maximum temperature of following postfiring will be equal to BAKING TEMP + P.S.STEP as in the first postfiring cycle. 11. BUILT-IN ILLUMINATING LAMP. ELITE-600 is equipped by built-in illuminating lamp that is microcomputer controlled. When baking cycle is over and working plate goes down the lamp is turned on automatically enabling excellent examination of processed work. The lamp is turned off automatically 30 seconds after baking cycle is completed or when START TEMP. is reached. If one of the control buttons DOWN/RESET, START or POSTFIRE is pressed, the lamp is turned off as well. You may turn the lamp manually on and off by pressing DOWN/RESET button. After 30 sec. delay the lamp turns off automatically. 12. AUTOMATIC NIGHT PROGRAM. Automatic night program enables to save operator's time in the end of work day. If the ON/OFF button is pressed when baking cycle is running, the OFF led is turned on in addition to the ON led. The furnace will finish the baking cycle as usual and after that will switch itself to the NIGHT program (No. 0). When temperature inside the muffle will reach 100ºC, the work table will go up and the muffle will stay at this temperature. It is possible to cancel automatic night program by pressing DOWN/RESET or POST FIRE buttons. Rev. 1-1 - 10-12/10

13. CHAMBER VENTILATION Chamber ventilation by vacuum pump is implemented in the ELITE-600 furnace to enable faster muffle cooling between sucsessive baking cycles. If the temperature inside the muffle exceeds starting temperature of the selected program by 10 degrees or more, the pump is turned on automatically when working plate descends to the DOWN position and ventilates the chamber. When the temperature drops to the START TEMP value, the pump turns off automatically. Chamber ventilation may be stopped manually by pressing RESET, START or POSTFIRE buttons. ATTENTION! Chamber ventilation is inhibited for baking programs 0 to 100 and is enabled for programs 101 to 200, so the ceramist may choose to use this feature or not by selecting appropriate program numbers. 14. HARDCOPY REPORT (optional) External printer may be connected to the ELITE-600 furnace via standard RS232 serial port (optional). After completing the baking cycle, hardcopy report containing baking parameters is printed automatically. Serial port settings: Baud rate - 19200 bps Bit length - 8 bit Stop bits - 1 bit Parity - Disabled Serial port connector - 9 pin D-type male connector. 15. CALIBRATION. Automatic calibration program is provided to correct temperature measurement that may change during extended use of the furnace. The sequence of operations during calibration procedure is as follows: a. Turn the furnace off, remove ceramic table, put calibration set on the work plate and center it.. b. Connect the pins on calibration plate using pure silver wire. c. Insert calibration plug into receptacle on the right side of the furnace. d. Turn the furnace on. e. Move work plate down, select calibration program (No 1) and press the START button. f. When muffle temperature reaches the melting point of silver (960ºC/1760ºF), temperature measurement of the furnace is adjusted to this temperature. The value of correction (positive or negative) appears on data display in form (C xx). For instance, when certain porcelain was fired at 970ºC (1780ºF) before calibration, it has to be baked at 980ºC Rev. 1-1 - 11-12/10

(1800ºF) after calibration if correction value was 10ºC (20ºF) and at 960ºC (1760ºF) if calibration value was -10ºC (-20ºF). g. Turn the furnace off, remove calibration set and return ceramic table. WARNING: 1. Calibration program will not start and bell will sound if there is not good electrical contract between silver wire and pins. 2. If calibration error occurs as a result of power line failure, the correction value will be cleared. Run calibration program to ensure correct temperature measurement. 16. SELF TESTS. Number of automatic self tests are implemented in ELITE-600 furnace to ensure high reliability, to avoid incidental damage to the work inside the furnace and to provide fast and easy maintenance. a. Baking program test. 1. When the furnace is turned on, all user programs are checked. If any program was changed because power line failure the message (test) appears on data display. Every program that was affected is cleared and User Error message (UErr) will blink on the display when the test is finished. 2. Parameter values are checked as they are entered. The value will not be accepted by the computer if it isn't within defined limits. 3. Parameter correlation is checked before every baking cycle. If correlation error occurs, the cycle will not start and blinking leds will point to problematical parameters. b. Calibration test. Temperature correction value is checked when the furnace is turned on. The test is similar to User test, but Calibration Error (CErr) appears in this case. WARNING: Temperature measurement may change when Calibration Error occurs. Run calibration program to get correct temperature reading. c. Muffle and thermocouple test. 1. If the muffle or the muffle fuse are burned, the Heat Error message (HErr) blinks on data display and the bell sounds every 30 sec. 2. If thermocouple is damaged, the Thermocouple Error message (terr) is displayed. d. Vacuum system test. When porcelain baking is provided in vacuum, vacuum level appears on vacuum display and vacuum system is checked. 1. If vacuum pump is not connected or doesn't work or pump fuse is burned, the bell will sound. 2. If vacuum level is not reached within 60 seconds, the bell will sound and vacuum display will blink. Rev. 1-1 - 12-12/10

3. If vacuum valve doesn't release vacuum in time, the bell will sound and vacuum display will blink. e. Micro-switch test. Upper and lower micro-switches are tested during work plate movement. If correspondent micro-switch was not depressed when work plate has reached its upper or lower position, the lift is stopped after 2 sec. Time-out and Position Error message (PErr) is blinking on Data display. Error message is cleared when PROG or PARAM push-buttons are pressed. 17. PROTECTION. a Power failure protection is provided to prevent work damage. 1. If power failure occurs when baking cycle with vacuum is running, vacuum is released from the chamber. 2. It is possible to move the work plate during power failure using mechanical joint and handle. WARNING: Don't use the handle when power is on. This may damage the mechanism. Rev. 1-1 - 13-12/10

BAKING PROGRAMS SERVICE PROGRAMS 0 1 2 3 number name Day Night Calib. Purge 300 100 650 700 -- -- -- 5:00 -- -- -- -- -- -- 30 90 -- -- -- 700 -- -- -- -- -- -- -- -- -- -- -- -- -- -- 1060 1040 -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- USER PROGRAMS number name Rev. 1-1 - 14-12/10

USER PROGRAMS number name USER PROGRAMS number name Rev. 1-1 - 15-12/10

USER PROGRAMS number name USER PROGRAMS number name Rev. 1-1 - 16-12/10

USER PROGRAMS number name USER PROGRAMS number name Rev. 1-1 - 17-12/10

USER PROGRAMS number name USER PROGRAMS number name Rev. 1-1 - 18-12/10

USER PROGRAMS number name USER PROGRAMS number name Rev. 1-1 - 19-12/10

USER PROGRAMS number name USER PROGRAMS number name Rev. 1-1 - 20-12/10

Forum Engineering Technologies (96) LTD. 1, Platin Str., New Industrial Zone, Rishon Lezion 75653, Israel Tel :972-3-9625517 Fax :972-3-9613355 www.forumtec.net E-mail :info@forumtec.net