Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Similar documents
Engineering Guideline. pac- Carriers Type Universal

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Instrumentation Products and Applications

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

EU RO MUTUAL RECOGNITION TYPE APPROVAL CERTIFICATE

explosion protection automation global partner of the process industry

Se vuoi ricevere aggiornamenti e novità compila i tuoi dati - In attesa di iniziare

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

Integrated redundant fieldbus power for FBM228 Foundation fieldbus modules High-density, compact design Fully isolated

SITRANS T temperature transmitters A broad product family for every application. sitrans

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Temperature Measurement

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

Product Information to the manual

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Dräger Polytron 7000 Fixed gas detector

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

Danfoss gas detection Controller unit

Temperature measurement with SITRANS T siemens.com/processinstrumentation

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Safe area; Zone 1 and Zone 2

Bionics Instrument. Alarm Handling. Gas Alarm Systems

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Temperature Measurement Transmitters for field mounting

operational excellence Solutions for

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

ME 3011C / Alarm Indication / Quick Reference Guide

INTERFACE AND SYSTEM SOLUTIONS. Explosion protection for automation

General Specifications

Gas Controller Module GC-06

Interface and EOL Modules 8

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

polar zone components and systems for extreme temperatures

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

Betriebsanleitung / Operation manual. Druckwächtereinheit QUINGUARD / Pressurization Controller QUINGUARD

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

PANEL MOUNTED ELECTRONIC MULTI-CIRCUIT HEAT-TRACING CONTROL, MONITORING AND POWER DISTRIBUTION SYSTEM mm. 100 mm

General Specifications

RS485 MODBUS Module 8AI

1.7. Insulation fault evaluators EDS460/490 EDS461/491

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

SAFEMASTER PRO. The configurable safety system versatile and extendable. Our experience. Your safety.

technical datasheet technical datasheet

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

Danfoss gas detection units

Insulation fault evaluator EDS460-DG

Operating Instructions Edition 02/2007

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Dual-point heat-tracing control system

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

On the job around the clock 24/7: Fire detection systems

AO Annunciator Module

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

Fire and Gas Monitoring Panel ST7-HV

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

920 Series. A dry contact relay is provided for alarm annunciation back to a distributed control system (DCS).

1.7. Insulation fault evaluators EDS460/490 EDS461/491

COMPACT FLAME CONTROLLER CFC 2000

DESCRIPTION. 42 mm. 125 mm

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

Assembly. Host Sub-D Alarm

RAYCHEM NGC-30 COMPONENTS

Two global companies, one solution.

Model 144H. Product Data Sheet , Rev DB February Content

INPUT / OUTPUT MINI MODULES

Fire control panels FC726 FC726-XA

General Specifications

Gas cylinder scale Model GCS-1

Danfoss gas detection unit Type GD Heavy Duty

Intelligent sensing for every temperature and condition

Analog Input Module IC670ALG630

Operating Instructions

910 Series Single-point heat-tracing control system

Connection of CET4-AP to Siemens ET 200S

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

SUPREMATouch. Modular Fire & Gas Detection System

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

Partners in Process Automation with Emerson Process Management for Intrinsic Safety

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Interface Modules for SENTRI

AU MX Digital Loop Card Installation Instructions

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Operating Manual MS220DA

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

Labkotec Ice Detector

NGC-40 Advanced Heat-Tracing Control System

Basics of Safety Applications

COMPACT FLAME CONTROLLER CFC 1000

20 Light Remote Annunciator

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

IntesisBox BACnet/IP Server - Notifier ID3000 series

Application Guideline. FOUNDATION TM fieldbus for LEPIU. Prepared by: Thomas Klatt Business Development Manager

Fire control panel detect 3004 plus and accessories

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Transcription:

Engineering Guideline pac-carriers Type 9195 SIEMENS ET-200M Fail-safe signal modules

pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Integration of conventional process automation interfaces - pac- Carrier The pac- Carrier reflects the intention of R. STAHL to provide state-of-the-art concepts tailored to the needs of process automation and machine manufacturing. It is designed to reduce the cost of installation by space saving compact design and simplified installation. The Ex i / I.S. isolators can be mounted without the need for a tool. The intrinsically safe signal is directly connected to the modules by means of two different types of detachable connectors - screw type or cage clamp type. The connection to the control system I/O module is simply done by connecting a customer specific cable to the screw terminal of the pac-carrier. The use of the pac- Carrier reduces the required time for installation and enables pre-wiring for later upgrades. Test accomplished In order to ensure a reliable interworking with the fail-safe system the ISpac solution was thoroughly tested by SIEMENS. The solution passed the test. Your benefits: 11 10 9 The most flexible system for the integration of Ex i / I.S. signals Complete line fault transparency - no blind spots Compact and rugged installation Pre-wiring enables easy and fault proved upgrade Systems for installation in hazardous location for the control system and Ex i / I.S. isolation made by R. STAHL 1 2 7 6 4 5 1. Detachable connectors - Screw terminals or - Cage clamp terminals or - Insulating cutting terminals 2. Labelling for module, slot and carrier. Ejector mechanism 4. Redundant and fused supply 5. Power supply failure and line fault signalling via relay 6. System cable plug 7. Signal duplication and/ or connection HART multiplexer 8. For DIN rail or mounting plate 9. Integrated pac bus for power supply and line-fault signalling 10. Secure snap-in mechanism, without tool 11. Single slot, any signal mixture 8 Example of 16 slots pac-carrier Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 HART-Multiplexer Type 9192 Basic function: multiplexer for HART field devices, 2 channels. The HART-Multiplexer type 9192 is used for digital connection of up to 2 HART-capable field devices, such as transmitters and regulating valves, to a PC. The PC communicates with the HART-Multiplexer via an RS 485 bus. The software PDM allows configuration and diagnostics of all connected HART-capable field devices, plus continuous documentation of the process variables and status. Interconnection: 9185/12-45-10 RS485 RS 22 or USB (via converter) 1 PC Fieldbus isolating repeater 1...4 Com-Port typical HART-Multiplexer 9192/2-10-10 pac- Carrier HART Connection Board 9195 9196 up to 2 channel Accessories and Spare Parts Designation Description Order number Fieldbus isolating repeater Adjustable baud rate (1.2 kbit/s up to 1.5 MBit/s) Power supply 24 V AC/DC 9185/12-45-10s pac-carrier 8 slots, HART 9195/11H-...-... 16 slots, HART 9195/12H-...-... Connection board for none Ex-applications, HART, 16 channels 9196/16H-XX0-... 2 9192/2-10-10 9195 9196 1 9192/2-10-10. 9192/2-10-10 9195 9196 9195 9196 up to 2 channel Daisy chaining of several pac- Carriers to one HART-Multiplexer: 4 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Line fault detection alarms for DI pac-carrier For one pac- Carrier 1. LFD is routed to terminal 7 and 8 on the pac-carrier (switch LF1 and LF2 OFF). Single channel module Pac- Carrier 9195/21A-SI1-0*B* Dual channel module 9195/*2A-SI1-0*B* 7 8 LF1 LF2-24 V 7 8 LF1 LF2-24 V Connection diagram Note Slot #1 Slot #8 or 16 Here can be used all channels of the pac- Carrier. Slot #1 Slot #8 or 16 2. LFD is routed into the last channel on the pac- Carrier; this avoids any external wiring of this alarm signal (switch LF1 and LF2 ON). Single channel module Dual channel module Pac- Carrier 9195/21A- SI1-0*B* 9195/12A- SI1-0*B* 7 8 LF1 LF2-24 V 7 8 LF1 LF2-24 V Connection diagram Slot #1 Slot #8 or 16 Slot #1 Slot #8 or 16 For several pac-carriers 1. These are routed into the last channel on the first pac- Carrier; this avoids any external wiring of LFD signal (one channel is reserved for all line faults in switch cabinet). switch LF1 OFF and LF2 ON 7 8 LF1 LF2 First pac- Carrier - 24 V Slot #1 Slot #8 or 16 switch LF1 OFF and LF2 OFF 7 8 switch LF1 ON and LF2 OFF 7 8 LF1 LF2 Last pac- Carrier - 24 V Slot #1 Slot #8 or 16 Engineering Guideline/SIEMENS 19.05.2015 5

pac-carrier Type 9195 6 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Contents DI Signal type DO I/O cards type SIMATIC ET 200M SIEMENS cable type Channels Slots HART- MUX 6ES7 26-1BK02-0AB0 6ES7922-B..0-0AS0 24 12 6ES7 26-1BK02-0AB0 6ES7922-B..0-0AS0 24 24 6ES7 26-2BF10-0AB0 6ES7922-B..0-0AN0 10 10 No No No pac-carrier (Ex-MTA) pac-carrier type ISpac page 9195/42A-SI2-01C7 9195/1A-SI2-01C7 9195/51A-SI2-02B4 9170/2*-11-11 9170/21-14-11 9-1 9170/1*-11-11 9170/11-14-11 15-19 9175/10-1*-11 9176/10-1*-00 21-26 6ES7 26-2BF10-0AB0 6ES7922-B..0-0AS0 10 10 No 9195/51A-SI2-02C7 9172/11-11-00 27-1 AI 6ES7 6-4GE00-0AB0 6ES7922-B..0-0AU0 6 6 Yes 9195/11H-SI2-0C7 9160/1-11-11 9160/1-11-1 916/1-11-11 9182/10-51-1-7 Engineering Guideline/SIEMENS 19.05.2015 7

pac-carrier Type 9195 8 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 pac-carrier Type 9195/42A-SI2-01C7 For SIEMENS / ET200M / 6ES7 26 1BK02 0AB0 Signal types: 24 x DI pac-carrier for 12 modules, up to 24 signals ISpac isolator 9170/2.-11-11 and 9170/21-14-11 can be used Customized system cable type 6ES7922 B..0 0AS0 to fail-safe module Redundant power supply with fault signalization contact and exchangeable fuses LFD can be routed into the last channel on the pac- Carrier; this avoids any external wiring of these alarm signals (switch LF1 and LF2 ON). 2 x T 1,25 A Fuse for power supply SIEMENS I/O-module Horizontal or vertical installation Simple installation on DIN rail or mounting plate Many labeling possibilities Fast and secure installation of the isolators without tools Comfortable exchange of the isolators with secured ejector mechanism Installation possible in Zone 2, Zone 22 (non-conductive dust) and Div. 2 05179E0 Comfortable and simple integration of the I.S. isolators ISpac into SIEMENS / fail-safe modular I/O station via system specific connection boards and system cables. System overview power supply power supply red. power fault line fault 1 2 4 5 6 7 8 + - + - Potential Equalization 9 10 contacts are closed in faultfree operation Power supply fuses for SIEMENS I/O-module 6ES7922 B..0 0AS0 6ES7922 B..0 0AS0 Funktion LF via channel 2 LF via terminal 7&8 ON X LF1 OFF X DI module 24xDC 24 V 6ES726 1BK02 0AB0 Red. DI module 24xDC 24 V 6ES726 1BK02 0AB0 LF2 ON OFF X X Engineering Guideline/SIEMENS 19.05.2015 9

pac-carrier Type 9195 DCS manufacturer Selection table Distributed I/O system I/O card type I/O station pac-carrier SIEMENS cable type Signal type Slots Type SIEMENS ET200M 6ES7 26 1BK02 0AB0 6ES7922 B..0 0AS0 24 x DI 12 9195/42A-SI2-01C7 Technical data Certificates Explosion protection Installation Power supply Nominal voltage U N Redundant supply Indication Fuse Polarity reversal protection Connection field devices Connection Number of channels Connection automation system Connection Number of channels Fuse Error messaging Power supply failure PF Line fault LF (of ISpac modules) Line fault switch LF1, LF2 ON Line fault switch LF1, LF2 OFF Ambient conditions Ambient temperature Storage temperature Relative humidity (no condensation) Mechanical data Weight Mounting type Mounting position Casing / Terminal protection class Casing material Fire protecting class (UL-94) BVS 0 ATEX E21 X II G Ex na nc II T4 Gc In Zone 2, Zone 22 (non-conductive dust), Div. 2 and in the safe area (X1) 24 V DC (19 V 1,2 V) yes, decoupled with diodes 2 LED green PWR1 ; PWR2 2 x TR5; T 2,0 A; exchangeable, for primary and redundant supply yes at the terminals of the I.S. isolators (see signal loops ) 24 (X01, X01 Red.) plug D-Sub 50 M pole up to 24 2 x T 1,25 A; exchangeable, for power supply SIEMENS I/O-module (X1) Contact (5 V / 100 ma), closed in good conditions Contact (5 V / 100 ma), closed in good conditions LF via last channel of pac- Carrier LF via terminal 7 & 8 of pac- Carrier max. - 20 C... + 70 C (see specification of the I.S. isolators) - 40 C... + 80 C 95 % appprox.20 g on DIN rail, (NS5 / 15, NS5 / 7.5) or mounting plate (4 x screw M6) horizontal or vertical IP 00 / IP 20 PA 6.6 V0 10 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Signal loops The diagrams below show typical applications. Please refer to the connection list to get the entire connection scheme. Basic technical parameters of the ISpac isolating repeaters can be found at the end of this document. The detailed specifications can be downloaded at: www.ispac.info. Switching repeater (DI) The last channel can be used as a fault message channel or as a signal channel Engineering Guideline/SIEMENS 19.05.2015 11

pac-carrier Type 9195 Accessories and Spare Parts Designation Illustration Description Order number Non-Ex i Termination Module The termination module is used to integrate non-ex i field circuit into the system integration solution pac-carrier type 9195. In such a way it enables a flexible mixture of Ex i and non-ex i field circuits. 9191/20-00-50s 0614E00 Dimension drawings (all dimensions in mm) - subject to alterations 216 mm 12471E00 Screw terminals Cage clamp terminals Dimension x 176 mm 186 mm Please note: In order to snap in the ISpac modules an extra space of appprox.50 mm is required. Please read the ISpac engineering guideline carefully before you start to engineer the enclosures with incorporated ISpac modules with or without pac-carriers. The ISpac engineering guideline can be downloaded from: www.ispac.info. 12 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Connection list For dual channel ISpac modules SIEMENS Modul: 6ES7 26 1BK02 0AB0 (24 x DI) We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice. The illustration cannot be considered binding. Engineering Guideline/SIEMENS 19.05.2015 1

pac-carrier Type 9195 14 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 pac-carrier Type 9195/1A-SI2-01C7 For SIEMENS / ET200M / 6ES7 26 1BK02 0AB0 Signal types: 24 x DI pac- Carrier for 24 modules, up to 24 signals ISpac isolator 9170/1.-11-11 and 9170/11-14-11 can be used Customized system cable type 6ES7922 B..0 0AS0 to fail-safe module Redundant power supply with fault signalization contact and exchangeable fuses LFD can be routed into the last channel on the pac- Carrier; this avoids any external wiring of these alarm signals (switch LF1 and LF2 ON). 2 x T 1,25 A Fuse for power supply SIEMENS I/O-module Horizontal or vertical installation Simple installation on DIN rail or mounting plate Many labeling possibilities Fast and secure installation of the isolators without tools Comfortable exchange of the isolators with secured ejector mechanism Installation possible in Zone 2, Zone 22 (non-conductive dust) and Div. 2 System overview power power power line fault Potential supply power supply power fault power line fault Equalization Potential supply red. supply fault Equalization red. 1 2 4 5 6 7 8 9 10 + 1-2 + - 4 5 6 7 8 9 10 + - + - 05179E0 Comfortable and simple integration of the I.S. isolators ISpac into SIEMENS / fail-safe modular I/O station via system specific connection boards and system cables. contacts are closed in faultfree contacts operation are closed in faultfree operation Power supply Power fuses supply for SIEMENS fuses for SIEMENS I/O-module I/O-module LF1 LF2 Funktion LF1 LF2 Funktion ON OFF ON OFF ON OFF ON OFF LF via X X channel LF via1 X X LF channel via 2 X X terminal LF via7&8 X X terminal 7&8 6ES7922 B..0 0AS0 6ES7922 B..0 0AS0 6ES7922 B..0 0AS0 DI module 24xDC 24 DI V module 6ES726 1BK02 0AB0 24xDC 24 V 6ES726 1BK02 0AB0 6ES7922 B..0 0AS0 Red. DI 24xDC Red. 24 DI Vmodule 6ES726 1BK02 0AB0 24xDC 24 V 6ES726 1BK02 0AB0 Engineering Guideline/SIEMENS 19.05.2015 15

pac-carrier Type 9195 DCS manufacturer Selection table Distributed I/O system I/O card type I/O station pac-carrier SIEMENS cable type Signal type Slots Type SIEMENS ET200M 6ES7 26 1BK02 0AB0 6ES7922 B..0 0AS0 24 x DI 24 9195/1A-SI2-01C7 Technical data Certificates Explosion protection Installation Power supply Nominal voltage U N Redundant supply Indication Fuse Polarity reversal protection Connection field devices Connection Number of channels Connection automation system Connection Number of channels Fuse Error messaging Power supply failure PF Line fault LF (of ISpac modules) Line fault switch LF1, LF2 ON Line fault switch LF1, LF2 OFF Ambient conditions Ambient temperature Storage temperature Relative humidity (no condensation) Mechanical data Weight Mounting type Mounting position Casing / Terminal protection class Casing material Fire protecting class (UL-94) BVS 0 ATEX E21 X II G Ex na nc II T4 Gc In Zone 2, Zone 22 (non-conductive dust), Div. 2 and in the safe area (X1) 24 V DC (19 V 1,2 V) yes, decoupled with diodes 2 LED green PWR1 ; PWR2 2 x TR5; T 2,0 A; exchangeable, for primary and redundant supply yes at the terminals of the I.S. isolators (see signal loops ) 24 (X01, X01 Red.) plug D-Sub 50 M pole up to 24 2 x T 1,25 A; exchangeable, for power supply SIEMENS I/O-module (X1) Contact (5 V / 100 ma), closed in good conditions Contact (5 V / 100 ma), closed in good conditions LF via last channel of pac- Carrier LF via terminal 7 & 8 of pac- Carrier max. - 20 C... + 70 C (see specification of the I.S. isolators) - 40 C... + 80 C 95 % appprox.20 g on DIN rail, (NS5 / 15, NS5 / 7.5) or mounting plate (4 x screw M6) horizontal or vertical IP 00 / IP 20 PA 6.6 V0 16 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Signal loops The diagrams below show typical applications. Please refer to the connection list to get the entire connection scheme. Basic technical parameters of the ISpac isolating repeaters can be found at the end of this document. The detailed specifications can be downloaded at: www.ispac.info. Switching repeater (DI) The last channel can be used as a fault message channel or as a signal channel Engineering Guideline/SIEMENS 19.05.2015 17

pac-carrier Type 9195 Accessories and Spare Parts Designation Illustration Description Order number Non-Ex i Termination Module The termination module is used to integrate non-ex i field circuit into the system integration solution pac-carrier type 9195. In such a way it enables a flexible mixture of Ex i and non-ex i field circuits. 9191/20-00-50s 0614E00 Dimension drawings (all dimensions in mm) - subject to alterations 42 mm 12471E00 Screw terminals Cage clamp terminals Dimension x 176 mm 186 mm Please note: In order to snap in the ISpac modules an extra space of appprox.50 mm is required. Please read the ISpac engineering guideline carefully before you start to engineer the enclosures with incorporated ISpac modules with or without pac-carriers. The ISpac engineering guideline can be downloaded from: www.ispac.info. 18 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Connection list For single channel ISpac modules SIEMENS Modul: 6ES7 26 1BK02 0AB0 (24 x DI) We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice. The illustration cannot be considered binding. Engineering Guideline/SIEMENS 19.05.2015 19

pac-carrier Type 9195 20 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 pac-carrier Type 9195/51A-SI2-02B4 For SIEMENS / ET200M/ 6ES726 2BF10 0AB0 Signal types: 10 x DO pac-carrier for 10 modules, up to 10 signals ISpac isolator 9175/10-1.-11 and 9176/10-1.-00 can be used Customized system cable type 6ES7922-B..0-0AN0 to fail-safe module Redundant power supply with fault signalization contact and exchangeable fuses 2 x T 2.0 A Fuse for power supply SIEMENS I/Omodule Horizontal or vertical installation Simple installation on DIN rail or mounting plate Many labeling possibilities Fast and secure installation of the isolators without tools Comfortable exchange of the isolators with secured ejector mechanism Installation possible in Zone 2, Zone 22 (non conductible dust) and Div. 2 05179E0 Comfortable and simple integration of the I.S. isolators ISpac into SIEMENS / fail-safe modular I/O station via system specific connection boards and system cables. System overview power supply power supply red. power fault line fault 1 2 4 5 6 7 8 + - + - Potential Equalization 9 10 contacts are closed in faultfree operation Power supply fuses for SIEMENS I/O-module 6ES7922 B..0 0AN0 6ES7922 B..0 0AN0 DO module 10xDC 24 V 6ES726 2BF10 0AB0 Red. DO module 10xDC 24 V 6ES726 2BF10 0AB0 Engineering Guideline/SIEMENS 19.05.2015 21

pac-carrier Type 9195 DCS manufacturer Selection table Distributed I/O system I/O card type I/O station pac-carrier SIEMENS cable type Signal type Slots Type SIEMENS ET200M 6ES726 2BF10 0AB0 6ES7922-B..0-0AN0 10 x DO 10 9195/51A-SI2-02B4 Technical data Certificates Explosion protection Installation Power supply Nominal voltage U N Redundant supply Indication Fuse Polarity reversal protection Connection field devices Connection Number of channels Connection automation system Connection Number of channels Fuse Error messaging Power supply failure PF Line fault LF (of ISpac modules) Ambient conditions Ambient temperature Storage temperature Relative humidity (no condensation) Mechanical data Weight Mounting type Mounting position Casing / Terminal protection class Casing material Fire protecting class (UL-94) BVS 0 ATEX E21 X II G Ex na nc II T4 Gc In Zone 2, Zone 22 (non-conductive dust), Div. 2 and in the safe area (X1) 24 V DC (19 V 1,2 V) yes, decoupled with diodes 2 LED green PWR1 ; PWR2 2 x TR5; T 2,0 A; exchangeable, for primary and redundant supply yes at the terminals of the I.S. isolators (see signal loops ) 10 (X01, X01 Red.) plug D-Sub 25 M pole up to 10 2 x T 2.0 A; exchangeable, for power supply SIEMENS I/O-module (X1) Contact (5 V / 100 ma), closed in good conditions Contact (5 V / 100 ma), closed in good conditions max. - 20 C... + 70 C (see specification of the I.S. isolators) - 40 C... + 80 C 95 % appprox.20 g on DIN rail, (NS5 / 15, NS5 / 7.5) or mounting plate (4 x screw M6) horizontal or vertical IP 00 / IP 20 PA 6.6 V0 22 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Signal loops The diagrams below show typical applications. Please refer to the connection list to get the entire connection scheme. Basic technical parameters of the ISpac isolating repeaters can be found at the end of this document. The detailed specifications can be downloaded at: www.ispac.info. Digital output (DO) Engineering Guideline/SIEMENS 19.05.2015 2

pac-carrier Type 9195 Accessories and Spare Parts Designation Illustration Description Order number Non-Ex i Termination Module The termination module is used to integrate non-ex i field circuit into the system integration solution pac-carrier type 9195. In such a way it enables a flexible mixture of Ex i and non-ex i field circuits. 9191/20-00-50s 0614E00 Dimension drawings (all dimensions in mm) - subject to alterations 180 mm 12471E00 Screw terminals Cage clamp terminals Dimension x 176 mm 186 mm Please note: In order to snap in the ISpac modules an extra space of appprox.50 mm is required. Please read the ISpac engineering guideline carefully before you start to engineer the enclosures with incorporated ISpac modules with or without pac-carriers. The ISpac engineering guideline can be downloaded from: www.ispac.info. 24 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Connection list For single Channel ISpac modules SIEMENS Modul: 6ES726 2BF10 0AB0 (10 x DO) Channel Terminal i.s. Carrier slot Terminal X01/ X01 Red. 40 Pin connector Input No. 0 1 2 4 5 6 7 8 9 0-9 10 + + 1 1 11 - - 0 V 10 + + 14 6 2 11 - - 0 V 10 + + 2 9 11 - - 0 V 10 + + 15 12 4 11 - - 0 V 10 + + 15 5 11 - - 0 V 10 + + 20 2 6 11 - - 0 V 10 + + 8 26 7 11 - - 0 V 10 + + 21 29 8 11 - - 0 V 10 + + 9 2 9 11 - - 0 V 10 + + 22 5 10 11 - - 0 V L+ + M - 4, 16, 17, 19, 10, 11, 2 5, 6,7, 12, 1, 18, 24, 25 17, 18, 21, 7, 8 19, 20, 22, 9, 40 0 1 2 4 5 6 7 8 9 0-9 We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice. The illustration cannot be considered binding. Engineering Guideline/SIEMENS 19.05.2015 25

pac-carrier Type 9195 26 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 pac-carrier Type 9195/51A-SI2-02C7 For SIEMENS / ET200M / 6ES726 2BF10 0AB0 Signal types: 10 x DO pac-carrier for 10 modules, up to 10 signals ISpac isolator 9172/11-11-00 can be used Customized system cable type 6ES7922-B..0-0AS0 to fail-safe module Redundant power supply with fault signalization contact and exchangeable fuses 2 x T 0,5 A Fuse for power supply SIEMENS I/Omodule Horizontal or vertical installation Simple installation on DIN rail or mounting plate Many labeling possibilities Fast and secure installation of the isolators without tools Comfortable exchange of the isolators with secured ejector mechanism Installation possible in Zone 2, Zone 22 (non conductible dust) and Div. 2 05179E0 Comfortable and simple integration of the I.S. isolators ISpac into SIEMENS / fail-safe modular I/O station via system specific connection boards and system cables. System overview power supply power supply red. power fault line fault 1 2 4 5 6 7 8 + - + - Potential Equalization 9 10 contacts are closed in faultfree operation Power supply fuses for SIEMENS I/O-module 6ES7922 B..0 0AS0 6ES7922 B..0 0AS0 DO module 10xDC 24 V 6ES726 2BF10 0AB0 Red. DO module 10xDC 24 V 6ES726 2BF10 0AB0 Engineering Guideline/SIEMENS 19.05.2015 27

pac-carrier Type 9195 DCS manufacturer Selection table Distributed I/O system I/O card type I/O station pac-carrier SIEMENS cable type Signal type Slots Type SIEMENS ET200M 6ES726 2BF10 0AB0 6ES7922-B..0-0AS0 10 x DO 10 9195/51A-SI2-02C7 Technical data Certificates Explosion protection Installation Power supply Nominal voltage U N Redundant supply Indication Fuse Polarity reversal protection Connection field devices Connection Number of channels Connection automation system Connection Number of channels Fuse Error messaging Power supply failure PF Line fault LF (of ISpac modules) Ambient conditions Ambient temperature Storage temperature Relative humidity (no condensation) Mechanical data Weight Mounting type Mounting position Casing / Terminal protection class Casing material Fire protecting class (UL-94) BVS 0 ATEX E21 X II G Ex na nc II T4 Gc In Zone 2, Zone 22 (non-conductive dust), Div. 2 and in the safe area (X1) 24 V DC (19 V 1,2 V) yes, decoupled with diodes 2 LED green PWR1 ; PWR2 2 x TR5; T 2,0 A; exchangeable, for primary and redundant supply yes at the terminals of the I.S. isolators (see signal loops ) 10 (X01, X01 Red.) plug D-Sub 50 M pole up to 10 2 x T 0,5 A; exchangeable, for power supply SIEMENS I/O-module (X1) Contact (5 V / 100 ma), closed in good conditions Contact (5 V / 100 ma), closed in good conditions max. - 20 C... + 70 C (see specification of the I.S. isolators) - 40 C... + 80 C 95 % appprox.20 g on DIN rail, (NS5 / 15, NS5 / 7.5) or mounting plate (4 x screw M6) horizontal or vertical IP 00 / IP 20 PA 6.6 V0 28 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Signal loops The diagrams below show typical applications. Please refer to the connection list to get the entire connection scheme. Basic technical parameters of the ISpac isolating repeaters can be found at the end of this document. The detailed specifications can be downloaded at: www.ispac.info. Digital output (DO) Engineering Guideline/SIEMENS 19.05.2015 29

pac-carrier Type 9195 Accessories and Spare Parts Designation Illustration Description Order number Non-Ex i Termination Module The termination module is used to integrate non-ex i field circuit into the system integration solution pac-carrier type 9195. In such a way it enables a flexible mixture of Ex i and non-ex i field circuits. 9191/20-00-50s 0614E00 Dimension drawings (all dimensions in mm) - subject to alterations 180 mm 12471E00 Screw terminals Cage clamp terminals Dimension x 176 mm 186 mm Please note: In order to snap in the ISpac modules an extra space of appprox.50 mm is required. Please read the ISpac engineering guideline carefully before you start to engineer the enclosures with incorporated ISpac modules with or without pac-carriers. The ISpac engineering guideline can be downloaded from: www.ispac.info. 0 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Connection list For dual Channel ISpac modules SIEMENS Modul: 6ES726 2BF10 0AB0 (10 x DO) Channel Terminal i.s. Carrier slot Terminal X01/ X01 Red. 40 Pin connector Input No. 0 1 2 4 5 6 7 8 9 10 + + 18 1 0 V 11 - - 10 + + 6 2 0 V 11 - - 10 + + 4 9 0 V 11 - - 10 + + 8 12 4 0 V 11 - - 10 + + 2 15 5 0 V 11 - - 10 + + 26 2 6 0 V 11 - - 10 + + 27 26 7 0 V 11 - - 10 + + 28 29 8 0 V 11 - - 10 + + 29 2 9 0 V 11 - - 10 + + 14 5 10 0 V 11 - - 0 1 2 4 5 6 7 8 9 0-9 L+ + M - 9, 15, 24, 1, 40, 49 8, 16,17, 25, 2,, 41, 42, 48 17, 18, 21, 7, 8 19, 20, 22, 9, 40 0-9 We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice. The illustration cannot be considered binding. Engineering Guideline/SIEMENS 19.05.2015 1

pac-carrier Type 9195 2 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 pac-carrier Type 9195/11H-SI2-0C7 For SIEMENS / ET200M / 6ES76 4GE00 0AB0 Signal types: 6 x AI pac-carrier for 6 modules, up to 6 signals ISpac isolator 9160/1-11-11, 9160/1-11-1, 916/1-11-11, 9182/10-51-1 can be used Customized system cable type 6ES7922-B..0-0AU0 to fail-safe module Redundant power supply with fault signalization contact and exchangeable fuses 2 x T 0,5 A Fuse for power supply SIEMENS I/Omodule Horizontal or vertical installation Simple installation on DIN rail or mounting plate Many labeling possibilities Fast and secure installation of the isolators without tools Comfortable exchange of the isolators with secured ejector mechanism Installation possible in Zone 2, Zone 22 (non conductible dust) and Div. 2 05179E0 Comfortable and simple integration of the I.S. isolators ISpac into SIEMENS / fail-safe modular I/O station via system specific connection boards and system cables. System overview HART-Connector 14pole for daisy-chain up to 2 channels power supply power supply red. power fault line fault 1 2 4 5 6 7 8 + - + - Potential Equalization 9 10 contacts are closed in faultfree operation System cable 6ES7922-B..0-0AU0 Red. AO module 8 x 12 bit 6ES76 4GE00 0AB0 System cable 6ES7922-B..0-0AU0 AO module 8 x 12 bit 6ES76 4GE00 0AB0 Power supply fuses for SIEMENS I/O-module HART connector 14 pole to type 9192 Fuse for HART-Multiplexer-module Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 DCS manufacturer Selection table Distributed I/O system I/O card type I/O station pac-carrier SIEMENS cable type Signal type Slots Type SIEMENS ET200M 6ES76 4GE00 0AB0 6ES7922-B..0-0AU0 6 x AI 6 9195/11H-SI2-0C7 Technical data Certificates Explosion protection Installation Power supply Nominal voltage U N Redundant supply Indication Fuse Polarity reversal protection Connection field devices Connection Number of channels Connection automation system Connection Number of channels Fuse HART interface Connector X1 Connector X2 Fuse Error messaging Power supply failure PF Line fault LF (of ISpac modules) Ambient conditions Ambient temperature Storage temperature Relative humidity (no condensation) Mechanical data Weight Mounting type Mounting position Casing / Terminal protection class Casing material Fire protecting class (UL-94) BVS 0 ATEX E21 X II G Ex na nc II T4 Gc In Zone 2, Zone 22 (non-conductive dust), Div. 2 and in the safe area (X1) 24 V DC (19 V 1,2 V) yes, decoupled with diodes 2 LED green PWR1 ; PWR2 2 x TR5; T 2,0 A; exchangeable, for primary and redundant supply yes at the terminals of the I.S. isolators (see signal loops ) 6 (X01, X01 Red.) plug D-Sub 50 M pole up to 6 2 x T 0,5 A; exchangeable, for power supply SIEMENS I/O-module HART connector 14 pole (to HART Multiplexer type 9192/2 or to first pac- Carrier) HART connector 14 pole optional to second pac- Carrier 1 x T 0,16 A; exchangeable, for power supply HART Multiplexer 9192 (X1) Contact (5 V / 100 ma), closed in good conditions Contact (5 V / 100 ma), closed in good conditions max. - 20 C... + 70 C (see specification of the I.S. isolators) - 40 C... + 80 C 95 % approx. 20 g on DIN rail, (NS5 / 15, NS5 / 7.5) or mounting plate (4 x screw M6) horizontal or vertical IP 00 / IP 20 PA 6.6 V0 4 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Signal loops The diagrams below show typical applications. Please refer to the connection list to get the entire connection scheme. Basic technical parameters of the ISpac isolating repeaters can be found at the end of this document. The detailed specifications can be downloaded at: www.ispac.info Transmitter supply unit (AI) Engineering Guideline/SIEMENS 19.05.2015 5

pac-carrier Type 9195 Accessories and Spare Parts Designation Illustration Description Order number Non-Ex i Termination Module The termination module is used to integrate non-ex i field circuit into the system integration solution pac-carrier type 9195. In such a way it enables a flexible mixture of Ex i and non-ex i field circuits. 9191/20-00-50s 0614E00 Dimension drawings (all dimensions in mm) - subject to alterations 12471E00 Screw terminals Cage clamp terminals Dimension x 176 mm 186 mm Please note: In order to snap in the ISpac modules an extra space of approx. 50 mm is required. Please read the ISpac engineering guideline carefully before you start to engineer the enclosures with incorporated ISpac modules with or without pac-carriers. The ISpac engineering guideline can be downloaded from: www.ispac.info. 6 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 Connection list For single Channel ISpac modules SIEMENS Modul: 6ES76 4GE00 0AB0 (6 x AI) Channel Terminal i.s. Carrier slot Terminal X01/ X01 Red. 20 Pin connector Input No. 0 1 2 4 5 0-5 10 + + 19 4 1 11 - - 27 5 10 + + 20 7 2 11 - - 28 8 10 + + 8 10 4 11 - - 46 11 10 + + 2 1 5 11 - - 47 14 6 10 + + 40 16 7 11 - - 15 17 10 + + 8 19 8 11 - - 2 20 L+ + 9 1 M - 7 2 0 1 2 4 5 0-5 We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice. The illustration cannot be considered binding. Engineering Guideline/SIEMENS 19.05.2015 7

pac-carrier Type 9195 8 Engineering Guideline/SIEMENS 19.05.2015

pac-carrier Type 9195 R. STAHL Schaltgeräte GmbH Am Bahnhof 0, D-7468 Waldenburg, Germany Telefon +49 7942 94-0 Telefax +49 7942 94-4 E-Mail: info.ex@stahl.de Internet: http://www.stahl.de S EG / SI Fail-Safe 9195 01 en 05 / 2015 Engineering Guideline/SIEMENS 19.05.2015 9