Rotary heat Thermal Wheel recovery unit. Plate heat exchanger recovery unit No condensation drain required. Wall mounted

Similar documents
TopMaster Air Handling unit. Technical data

Domestic & Commercial Fans

Home Solutions for Residential Ventilation

KOMFORT EC DB Suspended heat recovery air handling units

Topvex SR03, SR04, SR06 Compact Air Handling Unit

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

The Straight Way K Sileo Series

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Specification data Topvex. Rotating or Cross flow heat exchanger.

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Systemair Ventilation units

HRU SINGLE DWELLING HOUSES - ENERGY RECOVERY VENTILATION SYSTEMS WITH HEAT EXCHANGER AKOR BP HR Series

Heat Recovery Unit HERU. web-version

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

HRU SINGLE DWELLING HOUSES - BALANCED AIRFLOW WITH HEAT EXCHANGER AKOR ST HR Series

Topvex SF02-SF12 Air Handling Unit

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Office

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

Lo-Carbon Sentinel Kinetic Horizontal

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Heat Recovery Air Handling Units

Welcome to Systemair!

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

SAVE gives great indoor climate and saves energy

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Air Handling Units.

TopMaster Air Handling Unit

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Air Handling Units. direct drive - belt drive - custom built

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator School

DOMEKT. Heat Recovery Air Handling Units

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

The ultimate in air handling units: directly and indirectly fired

OPUSXBOX - SMALL COMMERCIAL HEAT RECOVERY SYSTEM LOW DEPTH, HEAT RECOVERY UNIT WITH MULTIPLE SPIGOTS AND ECOSMART CONTROLS.

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

The ultimate in air handling units: directly and indirectly fired

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Specification data. Rotovex SR IAQ. Air handling units Airflow m 3 /h.

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Series VENTS VUT R WH ЕС

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

CONTENT: VEX308 Decentralised ventilation VEX308

Flexit air handling units C2 and UNI 2, 3,4

EC L2. and humidity sensors. All units are supplied tested and ready to install.

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Topvex SoftCooler TR. Specification data

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

VR 400/700 DCV/DC. Good ventilation For dwellings, smaller offices and business premises. com

VERSO Air Handling Units

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

TECHNICAL SPECIFICATION

The ultimate in air handling units: directly and indirectly fired

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

The ultimate in air handling units: directly and indirectly fired

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Technical Information HXV - HRV Ventilation

Breathe Fresh Air at Home

DVU-HP. Integrated Reversible Heat Pump System

Heat recovery unit RDKS

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Systemair product news - Fans NEWS

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

VERSO Air Handling Units

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

UNITES TERMINALES ET MINI CTA FIDJI

VORT NRG RANGE COMMERCIAL VENTILATION NEW

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Danvent DV 190 and 240

Flexit air handling units UNI 2, 3 og 4

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Systemair Demand Control

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare

Caice Attenuator Selector - Specifier Edition

GOLD RX, GOLD RX 12 GOLD RX,

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

ACCORDING ErP 2018 HEAT RECOVERY VENTILATORS AIR TREATMENT AND FILTRATION UNITS

for fresher air Air Handling AIR VENT TECHNOLOGY Units DIRECT DRIVE - BELT DRIVE - CUSTOM BUILT Certificate No: GB9455

Small Room Heat Recovery Ventilation

Transcription:

Airflow max. m 3 /hr Plate heat exchanger recovery unit No condensation drain required Rotary heat Thermal Wheel recovery unit Wall mounted False ceiling void mounted Electrical battery Sound isolated Acoustic Lined Filter, fresh air Hot water battery Cooling water battery Control panel VR300TK/B 300 * * * * F7 * * 184 Page Number VX E 700 * * * F7 * * 185 VR 300 TK/B VX-E VX-EV VX EV 700 * * * F7 * * 185 VR EV 700 * * * * F7 * * 184 VR E 700 * * * * F7 * * 184 TLP 1600 * * * G4 * 186 TA 4500 * * * F5 * * * 187 TA Big 15000 * * F5 * * 18 VR-DC 700 * * * * F7 * * * 184 VR-DCV 700 * * * * F7 * * * 184 F 3000 Opt * * EU3 Opt Opt 11 K 12000 Opt * * EU3 Opt Opt 12 Maxi 2000 * * * F7 * * Opt * 13 Topvex FR 6552 * * * * F7 * * Opt * 45 VR-E VR-DC TLP VR-EV TA Maxi F - AHU K - AHU 17

K-Fan AHU Overview EC Compact design Easy to install Including heating and filter Heat recovery efficiencies up to 0% Automatic defrost functions Large front covers for easy maintenance Maintenance-free and reliable fan motors Cross flow heat exchanger Rotating heat exchanger - automatic change normal/summer operation - flexible installation without conden sation drain VR-DCV/DC TLP TLP Compact supply air unit for circular ducting with built in speed controllable fan. Housing made of galvanized sheet metal with a 50 mm acoustic insulation. Circular electrical heater and G3 filter included. Heater is controlled by a pulser with room temperature or duct sensor (not included). Max air flow 1350 m 3 /h. TA TA Compact supply air unit for circular/rectangular ducting suitable for supplying air to smaller buildings. The Plug & Play unit is powered by a single inlet centrifugal fan. Electrical or hot water heating battery and a F5 filter is included. Housing made from galvanized sheet metal with 50 mm acoustic insulation. Control unit for fan speed and heater is included with the unit. Max airflow 14 000 m 3 /h (size 6000-14 000 available in June-10). Accessories: Supply air damper, cooling battery. VR DCV and DC are complete air handling units suitable for homes, smaller offices and similar premises. With EC-fan motors and a new regulation system the energy use is optimized to be able to meet the new regulations on energy management. To ensure optimal operation, the rotating heat exchanger, supply and extract air filter, supply and extract fans, all temperature sensors and the re-heater are monitored. DCV(/B) units are designed for installation on wall, in laundry rooms, utility rooms or similar. With the white painted door and side panels the unit can easily be installed to blend in with the surroundings. Large inspection doors simplifies inspection and service. The VR 400 DCV/B has a by-pass function which allows the unit to be connected to a kitchen hood. The polluted air from the hood is led directly to the extract fan without coming in contact with the rotating heat exchanger. The DC-units are designed for mounting horizontal on the wall. They are manufactured with 50 mm insulation and are therefore suitable to be installed in cold premises e.g. store rooms, attics or similar. Max air flow 550 m 3 /h. VX-EV/E The VX range is a complete air handling unit suitable for ventilating homes, offices and smaller areas in commercial buildings. The cross flow heat exchanger are mostly used when there is a strong need to minimize the mixing of supply and extract air. The unit has an automatic defrost function of the cross flow heat exchanger. The EV model is suitable for wall mounting and the E model for lying on the side. The E model can also be mounted in cold areas due to the 50 mm of casing insulation. The unit is very easy to operate with the external control panel. Max air flow 550 m 3 /h. 180

K-Fan EC VR 300 ECV/B The VR 300 ECV/B is a very compact unit for ventilation of homes and primarily developed for wall mounted installation but can be installed horizontally e.g. in a false ceiling. The unit is double skinned, fully insulated, equipped EC-fan motors for supply/extract air, rotating heat exchanger, filters and thermostat operated re-heater battery. VR 300 ECV/B is equipped with large inspection hatches on both sides and is by that means reversible for optimal and simple duct connections. Max air flow 180 m 3 /h. Topvex FR Topvex FR03-11 is a series of efficient ventilation units designed for offices, shops, schools, daycare centre or similar premises. The units can be installed flat on the floor or suspended in a false ceiling. The units are especially designed to meet the coming energy requirements and have therefore a very low energy use and high efficiency rotating heat exchangers. To simplify the installation and commissioning, the units are included with control system and pre-configured. The unique design with double rotating heat exchangers makes the unit very flat. No need of condense-water drainage makes the unit very flexible to install. Max air flow 4000 m 3 /h. Topvex SR/SX Topvex SR/SX is a Plug and play air handling unit with a modern design intended for ventilating offices, day-care centres or used as zone ventilation in larger buildings e.g. schools. To meet the new restricted energy requirements with low SFP (Specific Fan Power). Topvex is equipped with EC fan motors. EC-motors consume an average of 30% less energy than AC motors. In some applications, the saving can be 50% or more. Topvex SR is equipped with a high efficiency rotating heat exchanger with an efficiency of up to 85%. Rotating heat exchangers do not need condense water drainage and is therefore very flexible to install. Topvex SX with its crossflow heat exchanger is normally used where it is a requirement that the supply and exhaust air must be kept separated. The units have an efficient de-icing function. Air Handling Units AHU Overview Topvex TR/TX Topvex TR/TX is a Plug and play air handling unit with a modern design intended for ventilating offices, day-care centres or used as zone ventilation in larger buildings e.g. schools. Top-connection of the air-ducts minimize the Footprint of the unit. To meet the new restricted energy requirements with low SFP (Specific Fan Power) Topvex is equipped with EC fan motors. EC-motors consume an average of 30% less energy than AC motors. In some applications, the saving can be 50% or more. Topvex TR is equipped with a high efficiency rotating heat exchanger with an efficiency of up to 85%. Rotating heat exchangers do not need condense water drainage and is therefore very flexible to install. Topvex TX with its crossflow heat exchanger is normally used where it is a requirement that the supply and exhaust air must be kept separated. The units have an efficient de-icing function. DV NB The DV and NB, air handling units (AHU) are highly flexible AHU s that can be configured to make up the heart of any mechanical ventilation system. The DV comes in a range of 12 different sizes with air volume capacities from 1500 m 3 /h to 54 000 m 3 /h, making it possible to always find the unit suitable for any requirement. The NB comes in a range of 15 different sizes with air volume capacities from 500 m 3 /h to 87 000 m 3 /h. Both DV and NB can be configured as supply units or as a supply exhaust units with heat exchanger, either Rotary Heat Exchanger, Plate Heat Exchanger or Run-around Coil Heat Exchangers. TIME The DV - TIME unit is available in 6 sizes and comes complete with pre-wired controls package. Air Volumes from 1440 m 3 /h to 14 400 m 3 /h Suitable for internal & external mounting. 181

K-Fan Compact EC Unit Air Handling Units - Overview Systemair has a wide range of air handling units for use in various applications from small office premises to larger Industrial use. Common to all items in the range is that systems and components have been developed to satisfy stringent demands for low energy consumption. Heat exchangers, motors and fan units have all undergone extensive testing, both in the laboratory and out in the field, in order to comply with current and future demands for low energy consumption. All products are also manufactured to comply with environmental requirements. To ensure easy installation, many of these units feature control systems enabled for plug-and-play, i.e simple start-up. TA 0.07-1.25 m 3 /s Supply air handling units intended for small to medium-sized premises. Available in 7 sizes and supplied complete with control system, fan, heating coil and filter. A separate extract fan can be linked into the control for Supply & Extract Ventilation. LPHW & Elec Heater Batteries available. 0.05 200 500 1000 1500 2000 4000 6000 m 3 /h 4500 3000 2000 1500 1100 650 450 m 3 /s 0.1 0.2 0.3 0.4 0.5 1 2 F 0.13-0.7 m 3 /s 500 1000 1500 2000 3000 m 3 /h False ceiling units for small and mediumsized premises. Available in 3 sizes and in 3 versions. 035 030 016 m 3 /s 0.1 0.2 0.3 0.4 0.5 1 1.4 Maxi 0.1-0.56 m 3 /s Compact air handling units with a low overall height and heat recovery, intended for small and medium-sized premises. Available in 2 sizes and supplied complete with control system. Also available with an electric or hot water heating coil. 0.08 500 1000 1500 2000 3000 1100 m 3 /s 0.1 0.2 0.3 0.4 0.5 1 2000 m 3 /h Topvex FR 0.15-1.78 m 3 /s Compact air handling units with a low overall height and heat recovery, intended for small and medium-sized premises. Available in 4 sizes and supplied complete with control system. Also available with an electric or hot water heating coil. Efficiencies up to 0% 182

K-Fan EC Air Handling Units Compact & Modular Units 200 500 1000 1500 2000 4000 6000 m 3 /h Topvex TR (rotating heat exchanger) 15 Topvex TX (cross-flow heat exchanger) 12 0 06 04 03 m 3 /s 0.05 0.1 0.2 0.3 0.4 0.5 1 2 Topvex TR/TX 0.0-1. m 3 /s Compact air handling units with top connection and rotating or cross-flow heat exchangers, intended for medium-sized premises. Supplied complete with control system. Equipped with EC motors and can be supplied with an electric or hot water heating coil. 200 500 1000 1500 2000 4000 6000 m 3 /h Topvex SR (rotating heat exchanger) 11 Topvex SX (cross-flow heat exchanger) 0 07 06 04 03 m 3 /s 0.05 0.1 0.2 0.3 0.4 0.5 1 2 Topvex SR/SX 0.1-1. m 3 /s Compact air handling units with side connection and rotating or cross-flow heat exchangers, intended for medium-sized premises. Supplied complete with control system. Equipped with EC motors and can be supplied with an electric or hot water heating coil. 1500 2000 4000 6000 10 000 15 000 40 m 3 /h 30 25 20 15 10 m 3 /s 0.3 0.4 0.5 1 2 3 4 5 TIME 0.4-4.0 m 3 /s Compact air handling units with heat recovery, intended for medium-sized premises. Available in 6 sizes and supplied complete with control system. Also available with heating coil and cooling coil. 1500 2000 3000 5000 10 000 20 000 30 000 50 000 0 000 240 m 3 /h 10 150 120 100 80 60 50 40 30 25 20 15 10 m 3 /s 0.4 0.7 1 2 3 5 10 15 20 25 DV 0.4-24 m 3 /s Modular air handling units intended for large premises. Available in 14 sizes. Large number of combinations and options. Systemair CAD selection programme can be downloaded from our website. 183

K-Fan VR Heat ECRecovery Units (Suitable for Residential Applications) VR-EV/B & VR-EV VR-EV/B and -EV is a complete air handling unit suitable for ventilating homes, offices and smaller areas in commercial buildings. With the white painted inspection door and the additional white painted side covers the unit is design to be mounted on the wall into e.g.; a laundry room. The rotating heat exchanger have the effciency of up to 85% and have the advantages that there is now water condensation and thereby no need of condensation drainage. The EV/B model has the advantage that it also can be connected to a cooker hood by using the integrated by-pass duct where the polluted air is lead direct to the extract fan. VR-E VR-E is a complete air handling unit suitable for ventilating homes, offices and smaller areas in commercial buildings. VR-E is designed to be mounted lying in the e.g. attic. The unit have double sheet metal casing with intermediate 50mm insulation and is therefore suitable to be mounted in cold places. To simplify the maintenance and make the installation more flexible the VR-E is equipped with large inspection doors on both of the sides. All components can be removed from each side. VR-E have a rotating heat exchanger and thereby the same advantages as for the VR-EV units. VR 300TK/B The VR 300 TK/B is a compact unit for ventilation of homes and primarily developed for wall mounted installation but can be installed horizontally e.g. in a false ceiling. The unit is double skinned, fully insulated, equipped with centrifugal fans for supply/extract air, rotating heat exchanger, filters and thermostat operated re-heater battery. VR 300 TK/B is quipped with large inspection hatches on both sides and is by that means reversible for optimal and simple duct connections. VR DC/DCV (SAP Appendix Q Rated) VR 400/700 DCV and DC are complete air handling units suitable for homes, smaller offices and similar premises. With EC-fan motors and a new regulation system the energy use is optimized to be able to meet the new regulations on energy management. Compared to AC-motors EC-motors maintain efficiency throughout the motor speed range when speed controlled and are therefore suitable to use in demand controlled ventilation units. Measurements show that an EC-motor reduces the energy use with up to 50% compared to a traditional voltage controlled AC-motor. VR Length Spigot Height Depth 250 EH/B 1071 ø125 273 540 400 E 114 ø160 576 44 700 E 114 ø200 576 53 VR Width Spigot Height Depth 300 TK/B 58 ø125 630 327 400 EV/B 76 ø160 800 406 700 EV 18 ø200 872 50 VR Width Spigot Height Depth 400 DC 114 ø160 576 44 700 DC 114 ø200 576 545 400 DCV/B 76 ø160 800 406 700 DCV 18 ø200 872 50 VR 400 DCV/B VR 400 DC VR 700 DCV VR 700 DC 2,5 2,5 2,5 2,5 2,0 2,0 2,0 1,5 1,5 2,0 1,5 1,5 3,0 = SFP value (Specific Fan Power) 3.0 = SFP value (Specific Fan Power) Technical Data VR 184 250EH/B 400E 700E 300TK/B 400EV/B 700EV 400DC 700DC 400DCV/B 700DCV Voltage/Frequency V/50 Hz 230 ~ 230 ~ 230 ~ 230-240 ~ 230-240 ~ 220 ~ 230 ~ 230 ~ 230 ~ 230 ~ Power, motors W 2x127 2x138 2x315 2x138 2x138 2x285 2x115 2x246 2x114 2x240 Power, re-heater kw 500 1670 1670 1000 1670 1670 1670 1670 1670 1670 Fuse A 10 10 16 10 10 16 10 13 10 13 Weight kg 40 57 70 45 62 80 55.5 66.4 57 72.3 Filter, fresh air bag F7 F7 F7 F7 F7 F7 F7 F7 F7 F7 Filter, extract air bag G3 G3 G3 G3 G3 G3 G3 G3 G3 G3

K-Fan ECVX Heat Recovery units (Suitable for Residential Applications) VX 250 TV/P The VX 250 TV/P is a compact unit for ventilation of apartments. The unit is designed to be mounted on the wall in a laundry room or similar. The unit is equipped with centrifugal fans for supply/extract air, cross flow heat exchanger, filters and thermostat operated re-heater battery. VX 250 TV/P is quipped with a large inspection door to simplify the maintenance. VX-E, -EV The VX range is a complete air handling unit suitable for ventilating homes, offices and smaller areas in commercial buildings. The cross flow heat exchanger are mostly used when there is a strong need to minimize the mixing of supply and extract air. The unit have an automatic defrost function of the cross flow heat exchanger. The EV-model is suitable for wall mounting and the E-model for lying on the side. The E-model can also be mounted in cold areas due to the 50mm of casing insulation. The unit is very easy to operate with the external control panel. TF AF FV TV FT VV VB OT BT L AT Fresh Air filter Extract Air Filter Exhaust Fan Supply Fan Defrosting Thermostat Heat Exchanger Elec Heater Battery Overheat Thermostat Emergency Thermostat Condensate drain Setting of supply air temperature Explanatory Diagram VX Width Spigot Height Depth 250 TV/P 600 ø125 600 25 400 EV 1 ø160 884 327 700 EV 18 ø200 8 507 VX Length Spigot Height Depth 400 E 118 ø160 650 327 700 E 118 ø200 651 500 VX 250TV/P 400EV 700EV 400E 700E Voltage/Frequency V/50 Hz 230-240~ 230~ 230~ 230~ 230~ Input power, motors W 2 x 115 2 x 138 2 x 315 2 x 152 2 x 308 Input power, re-heater battery W 1000 1670 2670 1670 2670 Mains fuse A 10 10 16 10 16 Weight kg 30 55 75 48 67 Filter, supply air F5 F7 F7 F7 F7 Filter, extract air Aluminium Aluminium Aluminium Aluminium Aluminium 185

K-Fan TLP - Supply EC Air Handling Unit Supply air units Filter, Elec Heater & Fan Acoustic Casing 50mm Insulation Speed-controllable A compact unit consisting of a fan and heater in galvanised sheet steel, and an EU4 filter. The casing is insulated inside with 50 mm of mineral wool. Rubber sealed sleeve couplings. Neoprene sealing strips and toggle locks. Note that the fan must always be connected to 230 V. Fan run-on is not normally required. (Lowest air velocity 1.5 m/s). Max output air temperature 40 C. The fan may be adjusted by either a transformer or a thyristor. The heating element is most effectively controlled by a power regulator, pulser and duct sensor. The filter should be checked regularly and replaced at least twice a year. 1 2 3 1 2 3 TLPW315 TLP 125/1.2 160/2.1 315/.0 TLPW315 Voltage/Frequency V/50 Hz 230 230 400 230 Phase ~ 1 1 3 1 Input, power el heating battery kw 1.2 2.1.0 Enq Current, el heating battery A 5.22.13 13 n/a Max temp transported air C 70 70 40 40 Temp control Pulser Pulser TTC 2000 AQUA Min air flow m 3 /h 70 110 415 180 Sound pressure level at 3 m db(a) 2.3 38. 4.5 33 Connection duct ø mm 125 160 315 315 Weight kg 31 33 54 75 Fan type K 125M K 160M KD 315L TLPW315 Voltage/Frequency V/50 Hz 230 230 230 230 Phase ~ 1 1 1 1 Power W 2 61 372 643 Current A 0.17 0.27 1.62 2.82 R.p.m. min-1 2483 24 255 1440 Speed control, five step Transformer RE 1.5 RE 1.5 RE 3 RTRE3 Speed control, high/low Transformer REU 1.5 REU 1.5 REU 3 REU3.0 Speed control, stepless Thyristor REE 1 REE 1 REE 2 STL3.0 TLP Length Spigot Width Height 125/1.2 786 ø125 45 436 160/2.1 786 ø160 45 436 315/.0 48 ø315 54 551 315/LPHW 83 ø315 546 585 186

K-Fan EC Supply air units with either LPHW or Elec Heating Low overall height for ceiling void mounting Complete with integrated control system Speed-controllable Remote Extract fan can be linked to controller Weather cover available for external mounting Air Handling Units TA - Supply Air Handling Unit c/w Controls TA is a series of air-handling units designed for ventilating petrol stations, schools, shops, offices and other smaller premises. The units have low overall height and are easy to install in existing premises. The units are delivered complete with control system, heating battery and filters. The TA EL has an electric re-heater, whilst the TA HW uses a hot-water battery for re-heating. Speed-controllable, high efficiency plug fans make service and cleaning easy. The double skin casing is insulated with 50 mm mineral wool to minimize sound to the environment. The units are controlled from a user-friendly control panel that can be mounted on the wall. TA-450EL, 650EL, 1100EL, 1500EL, 1500HW P s [Pa] 300 250 0 q v [m 3 /h] 200 400 600 800 1000 1200 1400 1600 1800 TA 450 EL TA Voltage V/50Hz TA 650 EL Motor W Heater kw TA 1100 EL TA 1500 EL/HW Airflow m 3 /s @ Pa 50Pa 100Pa 200Pa 300Pa 400Pa 500Pa 450EL 230/400 130 3/3 or 6 0.155 0.143 0.11 0.077 0.025 - EU5 650EL 400 220 5 or 8.3 0.22 0.21 0.17 0.15 0.1 0.06 EU5 1100EL 400 325 8 or 13.3 0.34 0.32 0.27 0.23 0.1 0.14 EU5 1500EL 400 548 12 or 20.3 0.4 0.47 0.42 0.37 0.31 0.25 EU5 1500HW 230 573 enq 0.41 0.4 0.35 0.3 0.25 0.2 EU5 2000EL 400 705 16 or 33.3 0.6 0.57 0.54 0.4 0.44 0.3 EU5 2000HW 400 673 enq 0.56 0.54 0.5 0.46 0.42 0.36 EU5 3000HW 400 1084 enq 0.5 0. 0.8 0.64 0.4 0.1 EU5 4500HW 400 1880 enq 1.44 1.3 1.27 1.12 0. 0.6 EU5 Filters 200 150 100 50 0 0 0,1 0,2 0,3 0,4 0,5 q v [m 3 /s] TA-2000EL, 2000HW, 3000HW, 4500HW P s [Pa] 300 250 200 150 TA 2000 HW TA 2000 EL 2000 3000 4000 5000 TA 3000 HW TA 4500 HW q v [m 3 /h] 100 50 0 0,4 0,6 0,8 1,0 1,2 1,4 1,6 q v [m 3 /s] 187

K-Fan TA Supply EC Air Handling Units TA Unit A B C D E F G H I J K L Dia dy N Weight kg 450EL 1125 500 354 200 dia - 51-1042 8 - - - - 176 50 650EL 1203 556 307 200 dia 6-1116 82 - - - - 702 55 1100EL 1233 620 374 250 dia 75-1146 140 - - - - 731 67 1500EL 110 750 374 200 400 105 175 1146 6 - - - - 731 82 1500HW 110 750 374 200 400 105 175 1146 175 102 125 162 21mm 731 71 2000EL 110 850 374 250 500 73 175 1146 73 - - - - 731 2000HW 110 850 374 250 500 73 175 1146 175 101 2 212 21mm 731 87 3000HW 126 04 545 300 600 141 152 1252 152 2 160 262 27mm 325 125 4500HW 1346 1006 545 400 700 1 153 1302 153 2 110 362 34mm 320 145 Suitable Extract Fans TA Unit Current Amps 230V Current Amps 400V In-line duct fan In-line duct fan In-line duct fan Roof mounted Roof mounted TA-450 0.7 - K200M KVK160L KVKE200 DVS225EZ DHS225EZ TA-650 1.0 - K200L KVK200 KVKE200 DVS225EZ DHS225EZ TA-1100 3.5 - KD250M KVK250L KVKE315M DVS311EV DHS311EV TA-1500 2.6 - KD250L RS40-20L KVKE315L DVS355E4 DHS355E4 TA-2000-2.8 MUB355DV RS60-35M3 RSI60-35M3 DVS355DV DHS355DV TA-3000-2.0 RSI60-35L3 KT60-35-6 KD400M3 DVS400DV DHS400DV TA-4500-4.3 MUB450DV KD400XL3 DVS450DV DHS450DV TF GT1 SV GTO GTF ST1 External extract Fan (See table for options) An extract fan can be connected to the unit and be operated in parallel with the TA supply unit. The extract fan must be 1-phase for TA units 450-1500 and 3-phase for TA units 2000 & above. The extract fan must also have integrated thermal contacts for protection against over heating. Explanatory Diagram Supply Fan Supply Air Sensor Actuator & Valve Overheat Sensor Frost Protection Sensor Fresh Air Damper Actuator L.P.H.W Water Battery Data Max. operating temp 100 C at 16 bar TA unit TA-1500 TA-2000 TA-3000 TA-4500 Water Battery Temp. (F&R) 60/40 70/50 80/60 60/40 70/50 80/60 60/40 70/50 80/60 60/40 70/50 80/60 Air flow m 3 /s 0.38 0.38 0.38 0.52 0.52 0.52 0.85 0.85 0.85 1.33 1.33 1.33 Outdoor temp. 0 C Supply temp. C 1.8 25.1 21.5 27.0 20.7 26.0 20.0 25.2 Water flow l/s 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.5 Pressure drop kpa 2. 4.3 2.6 3.8 2.7 4.0 2.2 3.3 Capacity kw.2 11.6 13.6 17.1 21.4 27.0 32.4 41.0 Outdoor temp. -10 C Supply temp. C 14.7 20.0 25.2 16.6 22.1 27.6 15.6 20. 26.2 14.8 20.1 25.3 Water flow l/s 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.5 0.6 0.7 Pressure drop kpa 4.3 5. 7.7 3.8 5.1 6.6 4.0 5.4 7.0 3.3 4.5 5. Capacity kw 11.4 13. 16.3 16. 20.4 23.8 26.5 32.1 37.6 40.3 48.8 57.4 188

K-Fan EC Supply AHU with Controls Duties from 0.8 to 4.40 m 3 /s Available in 5 casing sizes Compact Design Bag Filter, LPHW Coil & Fan Accessories available Low Breakout noise 50mm Insulation Pentapost Double Skin Construction Can be mounted externally (Roof Required) Air Handling Units TA Big - Supply AHU (LPHW & Controls) TA is a series of efficient ventilation units designed for schools, shops and offices, etc. The units are complete with controls and are delivered ready for operation. TA units are delivered pre-programmed, tested and ready for installation. Connect the unit to the duct system, (connect any external components), connect the mains power, set the timer and fan speed in the controller and the unit is installed. General TA units are delivered enclosed in plastic and mounted on pallets. The units are fully wired internally. The controller is preset and has been test-run at the factory. Cables for external components (outdoor air dampers, etc.) are connected to terminals in the electrical connection box. The same applies to the valve actuator for the heating coil. Measurement and control accuracy The supply air sensor, operates with an accuracy of +/-0.4K. The accuracy of the controlled temperature is the same. Unit housing The unit housing and doors are made of galvanised sheet steel with 50 mm mineral wool insulation for low noise to the surroundings. The TA units have large doors that make inspection and maintenance easy. The doors are lockable. The electrical connections are collected in one place to make it easy for the installer. The controls display is connected with a 10 m cable (included) TA Big Unit Voltage V Fuse A Motor kw L P H W Coil kw A B C D E F G H We i g h t kg 6000 HW 400-3-50 3x16 1. Enq 1720 1120 55 750 400 600 260 60 21 7000 HW 400-3-50 3x16 2.5 Enq 1720 1270 670 750 400 800 235 85 335 000 HW 400-3-50 3x20 3.3 Enq 1870 1420 745 00 500 00 260 85 387 11000 HW 400-3-50 3x25 3.6 Enq 1870 1570 820 00 600 1100 235 60 44 14000 HW 400-3-50 3x32 5.1 Enq 2020 1720 85 1050 600 1200 260 110 521 Full selections can be found on our website www.systemair.co.uk 18

K-Fan TA Big EC - Performance Curves 10

K-Fan EC Low Profile AHU s for ceiling void mounting Duties from 0.13 to 0.7 m 3 /s Available in 3 casing sizes Air Handling Units F - Air Handling Unit 3 sizes (from approx. 500 m³/h up to approx. 3.500 m³/h) Modular system, corrosion resistant aluminium profile with plastic corners 20 mm double skinned panels, manufactured from steel sheet with non-flammable mineral wool infill for thermal and acoustic insulation Variety of components (filter, heating, cooling, heat recovery.) Wide unit range: supply, exhaust, combined with/without heat recovery F AHU s F16 CB-23 F30 CH-23 Voltage/Frequency V/50 Hz 230 230 Input power, motors W 1150 1750 Input power, LPHW heater battery kw 14.0 24.0 Max Airflow m 3 /s 0.50 0.6 Fan Section Direct Drive GT1 280E4 GC1 356E4 Speed R.p.m 1210 1160 Current A 5.1 7.6 Sound Pressure level @ 3m db(a) 62 6 Weight kg 7 118 Filter, Supply Bag EU5 EU5 Heat Recovery Supply Units Extract Units Sound power (Lw) db(a) F16 CB-23 Mid frequency band 63 125 250 500 1k 2k 4k 8k LwA Inlet 62 65 67 70 76 74 72 67 LwA Outlet 64 67 6 72 78 76 74 6 LwA Surrounding 42 52 53 56 62 60 58 53 Measuring point: qv = 0.38m 3 /s @ 200Pa Sound power (Lw) db(a) F30 CH-23 Mid frequency band 63 125 250 500 1k 2k 4k 8k LwA Inlet 71 73 76 77 80 7 77 72 LwA Outlet 72 75 78 7 82 81 7 74 LwA Surrounding 45 54 56 5 65 63 61 56 Measuring point: qv = 0.40m 3 /s @ 450Pa 11

K - Air Handling Unit Modular AHU s for internal or External mounting Duties from 0.2 to 4.0 m 3 /s Available in 5 casing sizes 5 sizes (from approx. 500 m³/h up to approx. 15.000 m³/h) Modular system, corrosion resistant aluminium profile with aluminium corners or plastic corners 20 mm double skinned panels, manufactured from steel sheet with nonflammable mineral wool infill for thermal and acoustic insulation Variety of components (filter, heating, cooling, heat recovery,...) Wide unit range: supply, exhaust, combined with/without heat recovery K AHU s F25 CC-23 F42 CG-23 K62 CK-23 Voltage/Frequency V/50 Hz 230 400 400 Input power, motors W 1050 2800 500 Input power, LPHW heater battery kw 12.0 32.0 3.0 Max Airflow m 3 /s 0.36 1.14 1.3 Fan Section Direct Drive GC2 24E4 GC2 283D4 GC2 3D4-A Speed R.p.m 1180 1240 1120 Current A 4.6 4.60.30 Sound Pressure level @ 3m db(a) 60 65 72 Weight kg 8 136 14 Filter, Supply Bag EU5 EU5 EU5 Heat Recovery Supply Units Extract Units 12

K-Fan EC Air Handling Units Maxi - Heat Recovery Unit Complete with integrated control system Low overall height Easy to service EU7 fine filter Available with LPHW or Elec Htg External Roof Cover (Option) The MAXI unit are designed for the ventilation of smaller offices, shops or similar premises. The unit is to be installed horizontally in the attic, above a corridor or similar locations. The EL (Elec heating unit) can also be installed upside down. The MAXI 1100 is manufactured from galvanised sheet steel with 50 mm insulation (30 mm for the inspection covers.) The 2 inspection covers with quick-release fasteners together with removable motors and heat exchange unit facilitate easy service and maintenance. The MAXI 2000 unit is supplied in 2 parts to facilitate easy installation. The MAXI 2000 is manufactured from galvanised sheet steel, double skinned, with 50 mm of Rock-Wool insulation. To facilitate easy maintenance, the access covers are fitted with quick release clips. In addition, the motors and heat exchanger re removable. The heat recovery efficiency is approximately 55-70%. The MAXI EL has an electric re-heater, whilst the MAXI HW uses a hot-water battery for re-heating. A by-pass channel with motorized damper is built into the MAXI 1100 unit and is an optional extra on the MAXI 2000 unit. The integral transformer has a 7-step choice on the MAXI 1100 for fan speed and five-step choices on the MAXI 2000. The SCP control panel has an integral 7-day timer for selecting day and night operating settings. MAXI Voltage V/50Hz Motor W Main Fuse Amps Heater kw Airflow Airflow m 3 /s @ Pa Filters Weight kg 50Pa 100Pa 150Pa 200Pa 250Pa 300Pa 350Pa MAXI 1100EL 400 2x42 16 5 Supply 0.37 0.35 0.32 0.27 0.21 0.1 - EU7 172 Extract 0.33 0.30 0.26 0.22 0.14 0.05 - MAXI 1100HW 230 2x42 10 6.2-7.5 Supply 0.37 0.35 0.32 0.27 0.21 0.1 - EU7 16 Extract 0.33 0.30 0.26 0.22 0.14 0.05 - MAXI 2000EL 400 2x111 25 Supply 0.63 0.60 0.58 0.56 0.53 0.5 0.45 EU7 232 Extract 0.60 0.58 0.55 0.53 0.50 0.47 0.43 MAXI 2000HW 400 2x111 10 10. - 17.0 Supply 0.63 0.60 0.58 0.56 0.53 0.5 0.45 EU7 232 Extract 0.60 0.58 0.55 0.53 0.50 0.47 0.43 Sound power (Lw) db(a) Sound power (Lw) db(a) MAXI 1100 Mid frequency band MAXI 2000 Mid frequency band 63 125 250 500 1k 2k 4k 8k Tot 63 125 250 500 1k 2k 4k 8k Tot LwA Suppy Outlet 63 64 68 68 6 65 63 56 75 LwA Extract Inlet 44 53 47 50 42 40 3 34 56 LwA Surrounding 45 51 50 3 42 35 27 21 53 Measuring point: qv Suppy = 0.21m 3 /s / Extract = 0.18m 3 /s Max. 230V LwA Suppy Outlet 66 71 75 74 77 70 68 61 82 LwA Extract Inlet 64 73 75 75 80 71 6 62 83 LwA Surrounding 40 51 56 4 56 53 51 47 61 Measuring point: qv Suppy = 0.28m 3 /s @ 480Pa / Extract = 0.30m 3 /s @ 454 Pa Accessories MAXI 1100 MAXI 2000 Spring return damper EFD 315 EFD 315 Valve actuator for HW model HWRO HWRO Valve, 2-way TVTA 202 TVTA 452 Valve, 3-way TVTA 203 TVTA 453 By-pass Duct (heat exchanger) Built-in (inc) BP 1500/2000 Circ Duct Adapters - OKM 1500/2000 Cooling battery, water CWK 315 CWK315 Combi Roof Cowl THM THM Combi Wall Cowl VGM VGM Silencer LDC 315 LDC 315 Filter EU7 BFM 1100/7 BFM 2000/7 CO2 Room Sensor CO2RT-DR CO2RT-DR Room temp sensor TG-R5/PT1000 TG-R5/PT1000 Outdoor sensor (wall mounted) TG-R6/PT1000 TG-R6/PT1000 Exhaust air duct sensor TG-KH/PT1000 TG-KH/PT1000 13

K-Fan Maxi - EC Performance & Dimensions Supply Air Extract Air Supply Air Extract Air MAXI 1100 200 200 Purge Extract Repr Supply Souffl Extract Repr Alim entation électrique Alim entation hydraulique ø1/2'' Fresh Air Air neuf In Exhaust Refoul Fresh Air Air neuf In 315 MAXI 2000 Purge Air neuf Reprise Purge Refoulem ent Purge Soufflage Alimentation Air neuf électrique Alimentation hydraulique ø3/4'' Reprise Purge 14 FF Exhaust air fan TF Supply air fan F1 Supply air filter F2 Exhaust air filter GT1 Supply air sensor GT2 Outside air sensor GT3 Exhaust air sensor GT4 Defrost sensor GTO1 Overheat/Frost thermostat GTO2 Emergency thermostat GP1 Pressure switch - filter GP2 Pressure switch - filter GP3 Pressure switch - fan VVX Heat Exchanger ST1 By-pass damper & motor (accessory Maxi 2000) ST2 Damper & motor for heat exchanger ST3 Supply air damper & motor (EFD accessory) ST4 Exhaust air damper & motor (EFD accessory) VB1 Electric Heater Battery (EL Models only)