Air handling units Compair. Technical Catalogue

Similar documents
COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

Air handling units. Technical Catalogue

Air Handling Units. TopAir / TopAir Plus. Compact unit (plug&play)

Air handling units. Technical Catalogue

We simplify construction

We simplify construction

We simplify construction

Air handling units. Technical Catalogue

Air handling units. Technical Catalogue

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

KOMFORT EC DB Suspended heat recovery air handling units

l i nda b we si mpl i f y c onstr u ction Conforms ErP Ecodesign Lot 6 Residential and non-residential air handling units

Series VENTS VUT R WH ЕС

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

VENTILATION. Effective heat exchange and fresh air ventilation

AIR CONDITIONING UNIT WITH AN INTEGRATED HEAT PUMP

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

TAP v2.10 Version Date: 6/12/13. Document Microprocessor Controller for Tempered Air Products

VEX100 series Air handling units with cross-flow heat exchanger

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Vertical self-contained air conditioner

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

UNITES TERMINALES ET MINI CTA FIDJI

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

AIR HANDLING UNITS ver B

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

RIS V EKO A1/L2 RIS 700 V E L EKO 3.0 AIR HANDLING UNITS. Application

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

EC A1/L2 RIS P EKO RIS 400 P E 0.9 EKO 3.0 AIR HANDLING UNITS. Application

HYDRONIC SYSTEMS WHY CHOOSING BETWEEN ENERGY EFFICIENCY AND ROBUSTNESS?

TopMaster Air Handling unit. Technical data

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

lindab we simplify construction Lindab Compact air handling unit COMPAIR CF Transport, installation, start-up, maintenance and service manual

Integrated VarIable refrigerant flow ahu/pau (r410a)

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

recooler HP EQKR HEAT PUMP

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

TopVent Design Handbook

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

TopMaster Air Handling Unit

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Product catalogue Air handling units. Easy and flexible solutions for any ventilation requirements

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

AIR HANDLING UNITS MANDÍK

Energy Recovery with Cooling and Heating Model ERCH

COMMERCIAL LINE DUPLEX ROTO

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Complements and Accessories

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

PRODUCT GUIDE

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

VERSO Air Handling Units

RIS V EKO NEW! AHU with heat recovery. Centrales de traitement d air avec récupération de chaleur. AHU med varmegenvinding AIR HANDLING UNITS

TSEK VHR EC HEAT RECOVERY UNITS

CONTENT: VEX308 Decentralised ventilation VEX308

DAIKIN Air Handling Unit Modular

Air Handling Units. Geniox. Quick guide

Systemair product news - Fans NEWS

Control system. cabinet

IGH FX / IGH FX EC. Heat Recovery Ventilation Unit

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

SEQUENCE OF OPERATIONS

Hi-Pres Cooling Products Catalogue. Product Catalogue

CLIMASTER ZCF AIR HANDLING UNITS

HCompact2 HA. HCompact2 RHA series Air to air cooling units. HCompact2 IHA series Reversible air to air heat pumps

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

EC L2. and humidity sensors. All units are supplied tested and ready to install.

Heat Recovery Unit HERU. web-version

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Reference Guide for Microprocessor Controller

Technical manual MARK WTW AIRSTREAM _R01

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

Shunt groups and protection against freeze damage

Reference Guide for Microprocessor Controller

Transcription:

Air handling units Compair Technical Catalogue

Overview CompAir CF, CompAir RW, CompAir CF FREE CompAir CompAir is a family of air handling units in seven sizes, designed for volume air flow from 500 up to 11.000 m³/h. The basic characteristics of the unit is high efficient heat recovery of the exhaust air. As an additional option heating and/or cooling can be included. The basic model consists of a high efficient counterflow heat exchanger, an inlet and outlet fans, F7 filters on the inlet side and G4 filter on the outlet side. The basic model is built in one section, so called monoblock. Concerning the customer's requirements the units can be separated in more sections. These units are designed for outdoor and indoor installation. CompAir CF CompAir RW CompAir CF FREE 2

Content CompACT units plug&play 4 CompAir CF, CompAir RW, CompAir CF FREE 4 CompAir CF technical data 6 CompAir RW technical data 8 CompAir CF FREE technical data 10 Page 3

Compact units plug&play CompAir CF, CompAir RW, CompAir CF FREE CompAir CompAir is a family of air handling units in seven sizes, designed for volume air flow from 500 up to 11.000 m³/h. The basic characteristics of the unit is high efficient heat recovery of the exhaust air. As an additional option heating and/or cooling can be included. The basic model consists of a high efficient counterflow heat exchanger, an inlet and outlet fans, F7 filters on the inlet side and G4 filter on the outlet side. The basic model is built in one section, so called monoblock. Concerning the customer's requirements the units can be separated in more sections. These units are designed for outdoor and indoor installation. CompAir CF Basic version: CF: highly efficient counterfow heat exchanger with by-pass function, RW: highly efficient rotary wheel, CF FREE: reversible cooling system (heating and cooling) Inlet and outlet fans with electronically commutated motors and required electronics, filter on inlet and outlet side, upon customer s request: accessories and functions. Housing structure: sound and heat insulated aluminium profiiles and polyamid corner profiles, basic option see panels TopAir/Klimair2: T3, TB3 class. Plus option: panels TopAir Plus; T2, TB2 class. exterior of the panels coated by the RAL 7035. CompAir RW Configurations: compact monoblock [M], splitted [S], inside version [I], outside version [O]. Functions: water heater, water cooler, DX cooler, electrical heater, preheater, heater and cooler. 4

Accessories: PGD display and remote control, larger controllers, different PCO cards, different sensors, roof for outdoor version, an inlet and outlet hood for outdoor version, dampers with actuators, round duct connections, flexible connections, support feet, syphon. Control system, possibilities: continous or step-wise control of heating and cooling, continous control of heat recovery, free cooling function, de-icing protection, setting different air flows, clock card for time schedule, remote control by LCD display, fire sequence, free programming or override, constant pressure control, air flow rate control. Overview of compact air handling units CompAir CF CompAir RW Air flow rate size 1.000 2.000 3.000 4.000 Housing Airflow Heat recovery Type mm m³/h Type Up to % Klimair2/ TopAir/ TopAir Plus Klimair2/ TopAir/ TopAir Plus 50 500 10.700 93 50 1.100 11.500 85 Advantages: seven standard sizes cover all the requirements for residential, small and medium size business buildings, high efficiency up to 90 %, the units are distinguished by the high quality components, the units can be connected to any central control systems with different protocols. Further technical characteristics are available in Technical brochure CompAir on http://www.hidria.com/en/climate/ programs/ahu/. 6.000 8.000 10.000 0 1.500 3.000 4.500 Legend CF RW 6.000 7.500 9.000 10.500 12.000 m³/h 5

CompAir CF technical data Size 1000 2000 3000 4000 6000 8000 10000 Airflow range: (m³/h) 500-1150 1100-2300 2200-3400 3100-4500 4000-6400 6000-8300 8000-10700 Electrical supply: (V) Motor and fan type: 1 x 230 1 x 230 1 x 230 3 x 400 3 x 400 3 x 400 3 x 400 Radial plug-in fan with EC motor Frequency: 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz Input power (per fan): Current draw (per fan): Insulation: 500W 1350 W 1350 W 2500 W 3900 W 3900 W 5400 W 2,5 A 6,7 A 6,8 A 4,0 A 6,2 A 6,2 A 8,6 A 50 mm mineral wool Color: RAL 7035 Filter type: Filter class: Damper exhaust: Damper supply: Condense connection: Panel filter G4/F7 Outlet air damper 24 V actuator Supply (fresh air) damper 24 V actuator DN40 Duct dimension AxC (mm): 630 x 450 935 x 550 1035 x 550 1340 x 550 1660 x 690 1800 x 855 2155 x 855 Heater connections: 3/4 3/4 3/4 3/4 3/4 3/4 1 Cooler connections: 3/4 1 1 1 1 1/2 1 1/2 2 Dimension inside (mm): Monoblock / Splitted (L1+L2+L3) Splitted (L1+L2+L3) Length L (mm): 1670 1850 1970 1970 2360 2690 2690 Length with preheater or heater or cooler (mm): 1980 2160 2280 2280 2670 3000 3000 Length with heater and cooler (mm): 2100 2280 2400 2400 2790 3120 3120 Height H (mm): 1250 1450 1450 1450 1730 2060 2060 Width B (mm): 750 1055 1155 1460 1780 1920 2275 Dimension outside (mm): Monoblock / Splitted (L1+L2+L3) Splitted (L1+L2+L3) Length L (mm): 1880 2060 2180 2180 2690 3020 3020 Length with preheater or heater or cooler (mm): 2190 2370 2490 2490 3000 3330 3330 Length with heater and cooler (mm): 2310 2490 2610 2620 3120 3450 3450 Height H (mm): 1250 1450 1450 1450 1730 2060 2060 Width B/B1 (mm): 750/950 1055/1255 1155/1350 1460/1660 1780/1980 1920/2120 2275/2475 Length with preheater and heater or cooler (mm): inside Length with preheater and heater and cooler (mm): inside Length with preheater and heater or cooler (mm): outside Length with preheater and heater and cooler (mm): outside 2290 2470 2590 2590 2980 3310 3310 2410 2590 2710 2710 3100 3430 3430 2500 2680 2800 2800 3310 3640 3640 2620 2800 2920 2920 3430 3760 3760 Efficiency: up to 90 % Heat recovery: High efficiency counter flow plate heat exchanger Operating temperature: -20 C to 40 C 6

CompAir CF unit dimensions Monoblock inside version Monoblock outside version Splitted inside version Splitted outside version 7

CompAir RW technical data Size 2000 3000 4000 6000 8000 10000 Airflow range: (m³/h) 1100-2700 2100-3500 3100-5100 4500-7500 6500-9100 8000-11500 Electrical supply: (V) Motor and fan type: 1 x 230 1 x 230 3 x 400 3 x 400 3 x 400 3 x 400 Radial plug-in fan with EC motor Frequency: 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz Input power (per fan): Current draw (per fan): Insulation: 1350 W 1350 W 2500 W 3900 W 3900 W 5400 W 6,7 A 6,8 A 4,0 A 6,2 A 6,2 A 8,6 A 50 mm mineral wool Color: RAL 7035 Filter type: Filter class: Damper exhaust: Damper supply: Condense connection: Duct dimension AxC (mm): Panel filter G4/F7 Outlet air damper 24 V actuator Supply (fresh air) damper 24 V actuator DN40 935 x 550 1035 x 550 1340 x 550 1660 x 690 1800 x 855 2155 x 855 Heater connections: 3/4 3/4 3/4 3/4 3/4 1 Cooler connections: 1 1 1 1 1/2 1 1/2 2 Dimension inside/outside (mm): Monoblock / Splitted (L1+L2+L3) Splitted (L1+L2+L3) Length L (mm): 1670 1670 1670 1850 1970 1970 Length with preheater or heater or cooler (mm): 1980 1980 1980 2160 2280 2280 Length with heater and cooler (mm): 2100 2100 2100 2280 2400 2400 Length with preheater and heater or cooler (mm): 2290 2290 2290 2470 2590 2590 Length with preheater and heater and cooler (mm): inside 2410 2410 2410 2590 2710 2710 Height H (mm): 1450 1450 1450 1730 2060 2060 Width B/B1 (mm): 1055/1255 1155/1355 1460/1660 1780/1980 1920/2120 2275/2475 Efficiency: up to 85 % Heat recovery: Rotary wheel 250 mm Operating temperature: -20 C to 40 C 8

CompAir RW unit dimensions Monoblock inside version Monoblock outside version Splitted inside version Splitted outside version 9

CompAir FREE technical data Size 2000 3000 4000 6000 8000 10000 Airflow range: (m³/h) 1150-2300 2300-3500 3500-4600 4600-6400 6400-8300 8300-10700 Electrical supply: (V) Motor and fan type: Input power (per fan): Current draw (per fan): 1 x 230 1 x 230 3 x 400 3 x 400 3 x 400 3 x 400 Radial plug-in fan with EC motor 1350 W 1350 W 2500 W 3900 W 3900 W 5400 W 6,7 A 6,8 A 4,0 A 6,2 A 6,2 A 8,6 A Input power (per compressor) 1765 W 1765 W 2540 W 3300 W 4440 W 4440 W Current max (per compressor) 14 A 14 A 16 A 14,7 A 22 A 22 A Insulation: 50 mm mineral wool Color: RAL 7035 Filter type: Panel filter Filter class: Damper exhaust: Damper supply: Condense connection: G4/F7 Outlet air damper 24 V actuator Supply (fresh air) damper 24 V actuator DN40 Duct dimension AxC (mm): 935 x 550 1035 x 550 1340 x 550 1660 x 690 1800 x 855 2155 x 855 Cooling power to temp. outside 32 C in summer (kw) (min to max air flow): Heating power to temp. outside 0 C in winter (kw) (min to max air flow): 6,7 to 10,7 10,7 to 12,1 17 to 18,6 17,8 to 19,3 25,9 to 26,6 27,4 to 30 3,4 to 3,7 3,7 6 to 11,5 9,5 to 12,8 16,4 16,9 to 21 Dimension inside (mm): Splitted (L1+L2+L3+L4) Splitted (L1+L2+L3+L4) Length L4 910 910 910 910 910 910 Length L with cooling system (mm): 3070 3190 3190 3580 3910 3910 Height H (mm): 1450 1450 1450 1730 2060 2060 Width B (mm): 1055 1155 1460 1780 1920 2275 Dimension outside (mm): Splitted (L1+L2+L3+L4) Splitted (L1+L2+L3+L4) Length L4(mm): 910 910 910 910 910 910 Length L with cooling system (mm): 3280 3400 3400 3910 4240 4240 Length with heater (mm): 3280 3400 3400 3910 4240 4240 Height H (mm): 1450 1450 1450 1730 2060 2060 Width B/B1 (mm): 1055/1255 1155/1350 1460/1660 1780/1980 1920/2120 2275/2475 Length with preheater and heater or only preheater (mm) : inside Length with preheater and heater or only preheater (mm): outside 3380 3500 3500 3890 4220 4220 3590 3710 3710 4220 4550 4550 Efficiency: up to 90 % Heat recovery: Operating temperature cooling system: High efficiency counter flow plate heat exchanger 0 C to 32 C 10

CompAir FREE unit dimensions Splitted inside version Splitted outside version 11

Ordering key CompAir CF (Plus) 1000-FREE-R-I(1)-M-EW-DA1(1)3(1)-FC1234-RC1234-PH1(1)4(1)-FT-RF-SY-ECC1-PGD-PC1-QS1-PS1 PS1 PS2 PS3 x QS1 QS2 x Accessories 2 (regulation): 2x Pressure sensor (room QBM66.201) 2x Pressure sensor (duct QBM66.202) 2x Pressure sensor (airflow QBM66.203) without pressure sensor Sensor CO2 - duct Sensor CO2 - room Without CO2 sensor PC1 PCO Web Card pcoweb PC2 PCO Web Card pcoweb with interface PC3 PCO Card LONFTT3 PC4 PCO Card MODBUS 3 x Without card PGD x Remote controller Without remote controller ECC1-6 (See page 1) x Without ECC SY SYH x RF x FT x Accessories 3 (additional equipment): Syphon Heating syphon Without syphon Roof walleys Without roof walleys Feet Without feet PH1(1)4(1) Protection hood on standard connections 1,4 PH1(2)4(2) Protection hood on back side of unit x Without protection hood RC1234 Round connections on connections 1,2,3,4 RC24 Round connections on connections 2,4 x Without round connections FC1234 Flexible canvas on connections 1,2,3,4 FC24 Flexible canvas on connections 2,4 x Without flexible canvas DA1(1)3(1) DA1(2)3(2) DA1(x)3(x) DA1(1) DA1(2) DA1(x) x Dampers on connections 1,3 - actuator on/off Dampers on connections 1,3 - spring actuator Without actuator on both dampers Damper on connection 1 - actuator on/off Damper on connection 1 - spring actuator Without actuator Without damper and actuator Accessories see connections: 1) supply intake 2) supply outlet 3) exhaust intake 4) exhaust outlet Accessories 1 (function): E Empty section EW Water heater KW Water cooler EW+KW Water heater + water cooler EW+KD Water heater + dx cooler KD Dx cooler EWV Water pre-heater EE(6) Electrical heater (electrical heater power kw) EWV,EW Water pre-heater, water heater EWV,EW+KW Water pre-heater, water heater + cooler EE,EW Electrical pre-heater, water heater EE,EW+KW Electrical pre-heater, water heater + cooler KW(EW) Water reversible coil D/K Dx reversible coil x Without function Unit type: M Monoblock S Splitted I(1) Inside unit with supply on under side I(2) Inside unit with supply on upper side O(1) Outside unit with supply on under side O(2) Outside unit with supply on upper side O(3) Outside unit with bottom connection O(4) Outside unit with bottom connection and frame R Right L Left FREE reversible cooling system Unit size: 1000 2000 3000 4000 6000 8000 10000 Housing type: Plus Plus housing (empty) Basic housing Heat recovery type: CF Counterflow heat exchanger RW Rotary wheel exchanger 12

11

Lindab IMP Klima d.o.o. Godovič 150 5275 Godovič Slovenia T: +386 5 374 30 00 F: +386 5 374 30 82 E: imp-klima@lindab.com Issue 03/13