WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

Similar documents
CAUTION: EXPLOSIVE! Explosion Protection Made by WAGO

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Product Information to the manual

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Engineering Guideline. pac- Carriers Type Universal

Instrumentation Products and Applications

Manual. WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-xxx Definition of Terms, Marking and Installation Regulations. Version 1.0.

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

SITRANS T temperature transmitters A broad product family for every application. sitrans

Engineering Guideline. pac-carriers Type for TRICON system TRICONEX TMR PLC

Se vuoi ricevere aggiornamenti e novità compila i tuoi dati - In attesa di iniziare

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

explosion protection automation global partner of the process industry

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

Safe area; Zone 1 and Zone 2

Rosemount 3051CFC Compact Flowmeter

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Model 144H. Product Data Sheet , Rev DB February Content

Operating Instructions Edition 02/2007

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Electronic Pressure Digest. Pressure and Temperature Transmitters

Temperature measurement with SITRANS T siemens.com/processinstrumentation

Dräger REGARD -1 Control System

Temperature Measurement

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Dräger Polytron 7000 Fixed gas detector

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Model 144H. Product Data Sheet , Rev DB February Content

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Sitron s CF Line of Flow Switch Monitors

Size and rating wise typical Third Party Inspection certificates for the models of Valves

Temperature Measurement Transmitters for field mounting

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

WAGO Lighting Management The Lighting Control Solution Stay in Control of Your System

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Level gauges Series LS Level indicator, switch and transmitter for liquids

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Thermostats. Innovative solutions for the toughest requirements

Dräger Flame 2100 Flame Detection

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

Dräger Polytron Pulsar 2 Open Path Gas Detector

GETTING STARTED GUIDE NI AI/8 AO/4 DIO, 0 V to 5 V, 12 Bit, 20 ks/s Aggregate

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

EtherCAT Box Modules (EPxxxx-xxxx)

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

FAHM Co. Temperature Transmitter PTT74 Series

Dräger Polytron 5100 EC Detection of toxic gases and vapors

INTERFACE AND SYSTEM SOLUTIONS. Explosion protection for automation

Dräger Flame 2500 Flame Detection

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

GROUNDING MONITORING DEVICES AND SYSTEMS

Emerson Superheat Control. The smart solution for your application

Annubar Flowmeter Series

Application Guideline. FOUNDATION TM fieldbus for LEPIU. Prepared by: Thomas Klatt Business Development Manager

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

EU RO MUTUAL RECOGNITION TYPE APPROVAL CERTIFICATE

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

The SharpEye 40/40I (IR3) Flame Detection

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

Temperature Solutions Line Card

SYSTEMS PRODUCT OVERVIEW

... RD0-TI-Ex8.FF.* Temperature Multi-Input Device for Cabinet Installation. Features. Assembly. Function. Connection. Zone 1

Rosemount 2051T In-Line Pressure Transmitter

Laser Level Measurement Products. Introducing the New LLT100

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

Rosemount 2051T In-line Pressure Transmitter

HAUBER-Elektronik. Product overview. Condition monitoring Mechanical protection in compliance with DIN ISO 10816

Rosemount 3051CFP Integral Orifice Flowmeter

ue short form catalog Leaders in Safety, Alarm & emergency Shutdown

Hazardous Area Zirconia Oxygen Systems

FUNCTIONAL SAFETY MANUAL

OPTIBAR DP 7060 Supplementary Instructions

Rosemount 3144P Rosemount 3144P Temperature Transmitter

Dräger Flame 2700 (Multi-IR) Flame Detection

BDI-FLX B URST SY STE M BENEFITS BDI-FLX AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS

CRYOGENIC TEMPERATURE SENSOR SOLUTIONS FOR LIQUEFIED NATURAL GAS (LNG) TANK STORAGE

COMPACT FLAME CONTROLLER CFC 1000

Bernstein product overview

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

I.S. Interfaces. for the Process Industry. display. i.s. interface. isolation. temperature. universal

Dräger REGARD -1 Control System

ORIGA-SENSOFLEX Displacement Measuring System for Cylinder Series OSP-P

OPTIBAR P 1010/2010 C Supplementary instructions

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

SITRANS F M MAG 3100 P:

Dräger Flame 2500 (IR3) Flame Detection

Safety Transmitter / Logic Solver Hybrids. Standards Certification Education & Training Publishing Conferences & Exhibits

EXCELLENCE in Solutions Products Service

Rosemount 848T High Density Temperature Measurement Family

COMPACT FLAME CONTROLLER CFC 2000

Products and performance

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Transcription:

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

USE IN HAZARDOUS LOCATIONS Fieldbus-Independent I/O for Hazardous Areas In many plants across the chemical and petrochemical industries, as well as in the production and process automation sectors, installations are operated that process explosive gas- or dust-air mixtures. This is why electrical equipment must be explosion-proof in order to avoid injuries to personnel and damage to facilities. The blue Ex i Modules from the WAGO-I/O- SYSTEM 750 are designed for intrinsically safe applications in hazardous locations, providing users with all the benefits of modern fieldbus technology in a standard node. When installed in Zone 2/22, the system provides a safe, easy and cost-effective connection to sensors and actuators of Zones 0/20 and 1/21. It is ready for worldwide use thanks to extensive approvals (e.g., IECEx, as well as ABS, DNV, GL for marine applications). Zone 2/22 Zone 1/21 Zone 0/20

istock.com/ lagereek Globally approved for: NAMUR mining environments explosive gas environments explosive dust environments onshore/offshore environments (e.g., gas tankers, oil/gas pipelines) ATEX 94/9/EG r ANSI/ISA 12.12.01 HART

USE IN A VARIETY OF APPLICATIONS Rupture Disc with Pressure Switch per NAMUR From rupture disc feedback to valve limit switches, WAGO s compact 8-Channel Input Modules per NAMUR recommendation are the right choice for every application. Level Measurement: 4 20 ma Simple, safe and compact whether it s a level, temperature or pressure transmitter: The AI Modules (4 20 ma) are the backbone of WAGO s extremely compact and versatile remote I/O-System. Control Valve: 4 20 ma Specify the position control valves and related I/P converters can be easily controlled via WAGO s intrinsically safe 4 20 ma AO Modules. Zone 1 Zone 2 Flow Measurement (HART): 4 20 ma WAGO s HART AI Modules allow up to four auxiliary variables to be read in parallel, such as temperature and viscosity in addition to mass flow. Valve Interface Control valves via WAGO s intrinsically safe and short-circuit proof DO Modules for solenoid valve control and benefit from the advantages of modern fieldbus technology. Pt100 Resistance Thermometer Directly integrate both thermocouples and resistance sensors via WAGO s intrinsically safe AI Modules in low-interference environments no head transmitter required.

INTRINSICALLY SAFE MODULES OVERVIEW Supply Module 24 VDC 1.0 A Ex i, 750-606 PD Meter via Meter Module The pulse outputs of oval gear meters can be easily connected and evaluated via WAGO s intrinsically safe Meter Modules per DIN EN 60947-5-6 (NAMUR). Digital Input Modules 1DI NAMUR Ex i, 750-435 2DI NAMUR Ex i, 750-438 8DI NAMUR Ex i, 750-439 4F-Ex i DI 24 V PROFIsafe V2 ipar, 750-663/000-003 Digital Output Modules 2DO 24 VDC Ex i, 750-535 2DO Relay Ex i, 750-538 Analog Input Modules 2AI 4 20 ma Ex i, 750-485 2AI 4 20 ma HART Ex i, 750-484 2AI RTD Ex i, 750-481/003-000 2AI TC Ex i, 750-487/003-000 Analog Output Modules 2AO 0 20 ma Ex i, 750-585 2AO 4 20 ma Ex i, 750-586 Power Supplies for Zone 2 The perfect addition to WAGO s remote I/O-System for use in Zone 2 (Class 1, Div. 2): WAGO s EPSITRON ECO Power line of power supplies, including 2.5, 5 and 10 A models. Specialty Modules Up/Down Counter Ex i, 750-633 Power Supplies EPSITRON ECO POWER 24 VDC (22 28 V) / 2.5 A, 787-712 24 VDC (22 28 V) / 5 A, 787-722 24 VDC (22 28 V) / 10 A, 787-732

WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 32385 Minden Hansastraße 27 32423 Minden info@wago.com www.wago.com Headquarters +49 571/ 887-0 Sales +49 571/ 887-222 Order Service +49 571/ 887-44333 Fax +49 571/ 887-8 44169 0888-0150/0100-6901 EX FLYER 1.0 US 04/2016-00 Printed in Germany Subject to design changes WAGO is a registered trademark of WAGO Verwaltungsgesellschaft mbh. Copyright WAGO Kontakttechnik GmbH & Co. KG All rights reserved. The content and structure of the WAGO websites, catalogs, videos, and other WAGO media are subject to copyright. Distribution or modification to the contents of these pages and videos is prohibited. Furthermore, the content may neither be copied nor made available to third parties for commercial purposes. Also subject to copyright are the images and videos that were made available to WAGO Kontakttechnik GmbH & Co. KG by third parties.