Ultramax PB. Floor standing premix gas fired condensing boilers with outputs at 65, 85, 100 & 120kW BOILERS

Similar documents
Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

Thision L. Wall mounted gas fired condensing boilers with individual unit outputs from 48kW to 145kW and multi-boiler cascade sets up to 1140kW

Installation and Operating Manual for the EcoStar 500 Oil Condensing Floor Standing Range Output Range kw

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

Cast Iron Boilers. G Series ( kW)

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Sirius FS. Working towards a cleaner future

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Sirius WH. Working towards a cleaner future

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

Hamworthy. Wessex Modumax. High Efficiency, Fully Modulating Boilers Condensing & Non Condensing, Pre-mix, Gas Fired. Outputs 100kW to 750kW

Installation and Operating Manual for the ProCon 16, 27, 47, 75 & 77 Wall Mounted Condensing Boiler Range.

Hamworthy. Purewell VariHeat

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

Light commercial products. High output boilers Cascade systems

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Hamworthy Fleet Horizontal Floor Standing. Condensing Boilers Natural Gas Outputs 40kW to 350kW 5 YEAR HEAT EXCHANGER WARRANTY

ProCon Streamline Gas Condensing Boiler. Installation and Operating Manual.

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

Hamworthy Fleet Vertical Floor Standing. Condensing Boilers Natural Gas Outputs 80kW to 1050kW 5 YEAR HEAT EXCHANGER WARRANTY

S-AF Floor Standing Condensing Boiler kW

Hamworthy. Stratton Wall Hung. Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW

Hamworthy. Stratton Wall Hung. Stainless Steel Condensing Boilers Natural Gas or LPG Outputs 45kW to 100kW

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

Ultramax Floor Standing Condensing Boiler Operating & Maintenance Manual For Models

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

up to Seasonal efficienc (gross) y ErP Nat Gas 5:1 Part L LPG

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

Planner Documentation THISION L

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

Appliance and Controller Electrical Installation Guide.

Condensing Boiler It s a comfortable decision to make

Remeha Quinta 45 and 65

Remeha Quinta 30. Technical information. High-efficiency. condensing boiler for. wall mounted. installation. Output: kw

range W, Plus Condensing boilers kW Commercial & Industrial Boilers

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

superrange Super Series 4, Super Plus High efficiency modular boilers kW Commercial & Industrial Boilers

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

High Performance Electronic Modulation Automatic Cleaning Easy Installation 4 Power Levels: 9,15,25,42kW. Pellet Boilers. Future of Ecological Heating

Hamworthy. Fleet Wall Hung. Condensing Boilers Natural Gas Outputs 40kW to 150kW 5 YEAR HEAT EXCHANGER WARRANTY

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

Hamworthy. Melbury HE. High Efficiency Steel Shell Power Flame Boilers Gas, Oil, Biofuel or Dual Fuel Burners. Outputs 530kW to 10000kW

Stokvis R40 Boiler Gas-Fired Wall Hung Condensing

95% Hamworthy Fully Modulating, Low NOx, Stainless Steel, Condensing Modular Boilers. Wessex ModuMax mk3. New. Restyled with latest Siemens controls

ENERGY TOP. Condensing boiler solutions

SGE Condensing Gas - Solar Water Heater

CPM WALL HUNG GAS FIRED CONDENSING BOILERS. Installation, Commissioning and Maintenance instructions

GHP AWO 38 Technical overview

Worcester GB162 wall mounted gas-fired condensing boiler series

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

Hamworthy. Varmax. New. Fully modulating, low NOx, stainless steel, condensing boilers Natural Gas or LPG Outputs 120kW to 900kW

GENERAL. Table 2 General Data Boiler W45 W45P W60 W60P W80 W80P 2H - G20-20mbar / 3P - G31-37mbar

ecotec Instructions for installation and servicing Wall hung room sealed fan assisted condensing boiler For the installer

Assessment Schedule - TS.6

Installation and Operating Manual for the ProCon HT 150 & 225 Floor Standing Condensing Boiler Range.

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

Stored Water District Heating Interface Units. Heat Interface Units

ECONOFLAME R6000 LMS GAS FIRED CONDENSING BOILERS

Condensing Heat Exchanger Suitable Gas Fired Ideal GT & GTE boiler ranges

Remeha Quinta 85. Technical information. Remeha Quinta 85. High-efficiency. condensing boiler for wall. mounted installation.

ELECTRIC COMBINATION BOILER. (European Patent No: Design Right Protected.) TH12-450U MRK 2

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Natural Gas Models Only Minimiser G.C. Appliance No. FF FF FF

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

INSTALLATION AND SERVICING

SEALED THERMAL STORE

Strebel SC-B Wall-Hung Condensing Boiler

Domestic Gas Boiler Guide

Domestic Gas Boiler Guide

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

CPM, CPMSP Cascade header kits Installation, Commissioning and Maintenance Instructions

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

EVOMAX CONDENSING BOILER

INDEPENDENT COMBINATION & SYSTEM BOILERS.

Fusion 200, 300 & 500

pressurejetrange Buccaneer GTE, Falcon GTE, Harrier GTE, Viceroy GT, Viscount GTE, Vanguard L Pressure jet boilers kW

Remeha Quinta 115. Technical information. Remeha Quinta 115. High-efficiency. condensing boiler for wall. mounted installation.

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

PRODUCT CATALOGUE

Jetflush 4 Instruction Manual

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

STREBEL S-CB + Cascade Kits

THE REMEHA HIU RANGE Installation, operation and maintenance manual December 2017

EVOMAX CONDENSING BOILER

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Alpha CombiMax 350 and 600

Ridge End. DA Cooks. Progressing Meeting No:2. Neptune Responses Mechanical. 2 nd November 2015

STREBEL S-CB + Boiler Range

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

Condensing Boilers. Floor Mounted - Evomod, Imax Xtra & Imax Plus III. Commercial Heating Solutions.

Transcription:

Ultramax PB Floor standing premix gas fired condensing boilers with outputs at 65, 5, 100 & 120kW BOILERS

Feature packed and powerful Ultramax PB range of floor standing boilers includes four models with outputs at 65, 5, 100 and 120kW. Fully condensing and fabricated from durable stainless steel, these appliances return efficiency up to 109.% with a modulation range up to 6.:1. Low Noise and low NOx emissions are also prime features of the Ultramax PB Boiler. A comprehensive programmable boiler/system controller is included as standard which may be connected to intelligent room controls if desired. As an option, a low loss header can be incorporated into the boiler case as can a plate type heat exchanger to act as a separator to protect the boiler from the possible effects of dirt accumulation in older systems. The flue connection allows for either room sealed or open type application with the capability for extensive lengths of flue to be accommodated. With the footprint area of the largest model at less than 0.51m 2, the Ultramax PB Boilers are frugal on their space requirement making them a perfect choice where space constraints are a key factor in product selection. 2

Put your mind at rest It s easy to ignore your boiler and heating system - until it goes wrong or breaks down. A system failure, especially one caused by lack of maintenance, can be inconvenient and costly. It isn t hard to imagine the difficulties that problems with your heating system can cause. And in some situations lack of heating and hot water can be critical. Similar to your car, a regularly maintained heating system will run more efficiently and any potential problems can be resolved before they develop into major system failure. At MHS Boilers we provide a lifetime maintenance and service solution for your heating system - enabling you to rest safe in the knowledge that we ll take care of it. Go to www.mhsboilers.com and download or request a copy of our Maintenance and Service Solutions brochure. Financially, planned maintenance makes sense too. It avoids major capital outlay and the associated costs of system down time - plus it can keep your fuel costs down as well as ensuring you are minimising your emissions. Our highly skilled and trained service and technical support engineers are only a phone call away 3

Standard features Compact dimensions With a common height and width of 10mm and 710mm respectively and depths from 53mm to 71mm, the Ultramax PB Boilers pack a lot of power into a small space. Clean and quiet Utilising state of the art premix combustion technology; NOx emission does not exceed 33mg/kWh thus easily meeting the stringent requirements for the highest BREEAM points score for (low) NOx pollution. The combustion system is also extremely quiet with noise levels not exceeding 4dBA. Comprehensive controls Included is a control panel that not only manages the operation of the boiler but in addition, if required can control a heating and a hot water circuit with time and temperature scheduling. Alternatively, external controls by others may interface with and control the Ultramax PB Boiler. No need to worry about dirt contamination from old systems As an alternative to the inclusion of a low loss header within the boiler, the appliance may as an option, be supplied with an in-built plate type heat exchanger. This is an ideal option when utilising the Ultramax PB as a retrofit unit onto an aged and possibly very dirty existing system. The plate heat exchanger acts as a positive barrier to any contamination of the new boiler from dirt or sludge that may have accumulated in the old network of pipes and radiators. Weather compensation If required, for comfort and economy, the boiler may be set to operate with direct-on-boiler weather compensated flow temperatures, thus providing VT heating without the need for any additional system components such as mixing valves etc. Option of an in-built low loss header In keeping with modern heating system design characteristics, the typical way of connecting an Ultramax PB Boiler to a heating system is via a low loss header. If desired, as an option, the boiler may be equipped with an internal low loss header thereby simplifying the installation Important information with regard to Part L2 of the Building Regulations Calculated in accordance with the formula given in the Nondomestic heating, cooling and ventilation compliance guide (Compliance with Approved Documents L2A & L2B) the Ultramax PB Boilers have Gross Seasonal Efficiencies of: Model 65 = 96.4%. Model 5 = 96.66%. Model 100 = 96.66%. Model 120 = 96.4%. Warranty The heat exchanger carries a 5 year guarantee; all other components carry a 12 month guarantee. All guarantees are against manufacturing or material defects only. Extending your warrenty with an MHS Boilers Maintenance and Service Plan will ensure long-term optimised heating while minimising your risk of liability beyond the statutory warranty period, and at clearly calculable costs. 4

Dimensions and clearances Optional parallel flue connection top casing panel is delivered packed inside the boiler casing at the r/h side Installation requirements The Ultramax PB series of boilers must be installed in accordance with (as appropriate) the relevant requirements of the Building Regulations, Health and Safety Regulation PM5, IEE Regulations, Gas Safety (Installation & Use) Regulations, National Water Bylaws, Clean Air Act, and any Insurance Company requirements Codes of practice BS 60 Code of Practice for low temperature hot water heating systems for output greater than 45kW, Parts 1, 2 & 3: 19. BS 6644 2005. Specification for installation of gas-fired hot water boilers of rated inputs between 70kW (net) and 1.MW (net) (2nd and 3rd family gases). IGE/UP/2 Gas installation pipework, boosters and compressors on industrial and commercial premises. IGE/UP/10 Installation of gas appliances in industrial and commercial premises, Part 1: Flued appliances. CIBSE Guide Sections B7, B11 and B13. LPG When boilers are fired with LPG it is advisable that gas leakage detection equipment is installed at low level near the boiler/s. 5

Optional hydraulic kits The (base version) Ultramax PB Boiler as in Fig.1 (page10) is an appliance that includes an in-built pump (with residual head performance as detailed in the Technical Data Table on page 5) and can be (as appropriate) directly hydraulically coupled to the central heating system or via an external local low loss header. To enhance the boiler, optional Hydraulic Kits are available as described below. The kits are supplied separately for the installer to apply. Optional in-built low loss header This kit provides a neat and speedy solution to the installation of a low loss header; installation time and space saving 13 4 12 6 7 3 14 5 9 10 1 4 11 3 2 6 1 6 7 1 Drain valve 1 /2" 2 Tube - Pump inlet 3 Compression fittings 4 Tubes - Flow & return connections 5 Low loss header 6 MF elbow 7 Blanking plugs R 1 /2" Seal washers - Flow & return tubes 9 Seal washer - Pump inlet 10 Tube - Boiler flow to low loss header 11 Blanking plug R 1 /4" 12 Cap 3 /4" 13 Vent valve 1 /2" 14 Temperature sensor 10 12 11 5 13 4 3 14 9 4 3 6 1 2 6

Optional in-built boiler protection plate heat exchanger This option for the Ultramax PB Boiler is offered for use when the appliance is being used as a retrofit unit onto an aged system where the system may be contaminated with sludge etc which will cause damage to the new boiler if allowed to pass into the heat exchanger or pump etc. This device acts as a barrier to system contaminants, can also act as a pressure break and will also allow this sealed system type product to be applied to an old open vented existing system where there is risk associated with converting the old system to a sealed and pressurised type. 5 11 9 10 2 15 12 13 7 4 1 1 Plate heat exchanger 2 Expansion vessel for boiler 3 Drain valve 1 /2" 4 Boiler pressure gauge 5 Boiler pressure relief valve 3 /4" 6 Tube - pump inlet 7 Compression fittings Tubes - Flow & return connections 9 Tube - Boiler flow to plate heat exchanger 10 Tube - Expansion vessel connection 15 16 14 12 13 7 3 6 15 11 Reducing elbow 3 /4" x 1 /2" 12 MF elbows 1 /2" 13 Blanking plugs r 1 /2" 14 Seal washer - Pump inlet 15 Seal washers - Flow & return tubes 16 Tube - Boiler pressure relief valve discharge 1" x 150mm 9 5 4 16 6 7 7 10 11 2 1 15 7

Technical data Ultramax Boiler Model PB 65 PB 5 PB 100 PB 120 Product Identification Number Gas Category 0063BQ300 112ELL3P / 112H3P Nominal Heat Output 0/60ºC kw.4-60.0 15.6-77. 17.6-.2 21.9-109. Nominal Heat Output 40/30ºC kw 9.4-65.0 17.0-5.0 19.2-96.3 24.0-120.0 Nominal Heat Input Net kw.6-60.7 16.0-0.0 1.0-90.0 22.5-112.4 Gas Input Natural Gas G20 m3/h 6.2.2 9.32 11.65 Gas Input LPG G31 m3/h 2.42 3.2 3.6 4.6 Inlet Gas Pressure G20 Min/Max mbar 20/25 20/25 20/25 20/25 Inlet Gas Pressure G31 Min/Max mbar 30/50 30/50 30/50 30/50 Max Fluegas Mass G20 kg/h 111.6 147.6 165.6 20. Residual Flue Positive Pressure Max Pa 230 230 230 230 Max Flow Temperature ºC 5 5 5 5 Water Pressure Min/Max bar 1.0/3.0 1.0/3.0 1.0/3.0 1.0/3.0 Residual Pump Head (Standard Blr Version) kpa 11 11 23 15 Flow/Return Connections BSP 1 1 /4" 1 1 /4" 1 1 /4" 1 1 /4" Gas Connection BSP 1 1 /4" 1 1 /4" 1 1 /4" 1 1 /4" Flue Connection Concentric mm 110/150 110/150 110/150 110/150 Flue Connection Parallel mm 2 x 110 2 x 110 2 x 110 2 x 110 Condense Waste Connection Tail mm 25 25 25 25 Water Content l 6.6.4 10.3 12.0 Weight Dry/Wet kg 115/121.6 120/12.4 145/155.3 150/162.0 Electrical Supply Voltage / / Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 Phases Power Consumption Max (inc. internal pump) W 240 321 363 41 Design Water Flow Rate @ t20ºc l/s 0.71 0.93 1.10 1.31 Efficiency @ Full Load Gross/Net % 7./97.5 7.5/97.2 7.5/97.2 7.5/97.2 Efficiency @ 30 % of Full Load Gross/Net % 97.3/10.0 96.9/107.6 96.9/107.6 96.9/107.6 Flue Classification B23, C13, C33, C43, C53, C63, C3 Optional Accessory Items Weight of Low Loss Header kg 9.1 9.1 9.1 9.1 Resistance of Boiler with Inbuilt Low Loss Header kpa 5.3 9.0 13.0 1.0 Weight of Boiler Protection Plate Heat Exchanger kg 14.5 14.5 14.5 16.4 Resistance of Secondary Side of Plate Heat Exchanger kpa 9.5 15.9 21. 1.6 Maximum Pressure - Secondary Side of Plate Heat Exchanger bar 6.0 6.0 6.0 6.0

Filling the system The Initial filling of a sealed heating system, and subsequent refilling, must be by a method that has been approved by the Water Regulation Advisory Scheme (WRAS) for the type of heating system, i.e. Domestic (in-house) Fluid Category 3 (C-3). Non Domestic (other than in-house) Fluid Category 4 (C-4). For Category 4 systems The approved method of filling must comprise of the following components in the arrangement shown; Control Valve, on the Mains Cold Water pipework. Strainer. Verifiable Backflow Device with Reduced Pressure Zone (RPZ Valve) Incorporating a Type BA air gap. Tundish Control Valve, on the Heating System pipework. RPZ MCWS CV Strainer CV Tundish Heating system System water Ultramax PB series boilers must only be installed onto sealed and pressurised systems with a minimum static pressure of 1bar. All systems must be thoroughly cleansed prior to the connection of the boiler and the system water must be dosed with a good quality treatment to prevent corrosion within the system and the formation of scale within the boiler waterways. The chloride content of the fill water must not exceed 200mg/l. Particular care must be taken when installing the boiler onto an old system, with consideration given to the installation of a dirt arrester/filter or the use of the plate heat exchanger option. For specialist advice and water treatment products, contact: Fernox, Tandem House, Marlowe way, Beddington Farm Road, Croydon CR0 4XS. Tel: 020 665 6666 or Betz Dearborn Ltd, Widnes, Cheshire WA UD. Tel: 0151 495 16 Flue system The Ultramax PB Boilers have been tested using 110/150 Concentric Flue and as a result of the examination, the appliances may be used with up to 15m of Concentric Flue Pipe plus 4 x 93 degree bends plus a Concentric Terminal. If planning to install a non room sealed flue; the following data will be of assistance: Boiler Model PB 65 PB 5 PB 100 PB120 Max Resistance of Flue Pa 230 230 230 230 1m Length 110mm Ø PP Flue Gas Tube Pa 1.25 2.25 3.0 4.0 110mm Ø 93º PP Bend Pa 1.25 2.25 3.0 4.0 110mm Ø 45º PP Bend Pa 1.0 1. 2.4 3.2 110mm Ø Open Termination with Bird Mesh Guard Pa 1.25 2.25 3.0 4.0 9

Electrical connection There are two terminal rails located in the upper right hand area of the boiler under a removable cover plate. Low Voltage Terminal Rail Terminal No's 50-51 = QAA 73 modulating room unit (optional extra) 52-53 = Volt free contact room thermostat (alternative to QAA 73) 54-55 = Factory fitted inlet gas pressure switch. Do not tamper. 56-57 = No function 5-59 = HWS sensor (QAZ 36) or thermostat 60-61 = Outside air temperature sensor (QAC34/101) Supplied as standard with boiler Mains Voltage Terminal Rail Terminal L1 = Supply Phase 220-240V 10A N = Supply Neutral E = Earth E = Earth E = Earth E = Earth 1-2 = External Safety Interlock (Remove link to connect a volt free external interlock device) 3 (L) - 4(N) = DHW Primary Pump (max 1Amp) 6(N) - 7 (L) = Factory Fitted Internal Boiler Pump. Do Not Tamper (N) - 9(L) = Heating Circuit Pump (max 1Amp) Optional additional control items A number of optional extra control items are available to enhance the control and or monitoring of the Ultramax PB Boiler. BMS volt free contact alarm interface - Clip-in Module"AGU2.5" (optional extra) will provide volt free contacts to monitor "run" and "fault alarm" status. In addition the AGU2.5 Module allows analogue control input (0-10Vdc & 0-20 m Amp) to be connected to a single boiler. QAA 73 Remote Room Unit, allows time and temperature scheduling of a (weather compensated if required) heating circuit and a hot water circuit, with room influence and optimization if required (For use with a single boiler only). AGU 2.500 Clip-In Module. Allows a 2nd heating circuit, with or without a mixing valve to be connected to a single boiler. RVA 63.20 A controller which provides time and temperature scheduling over two heating circuits (weather compensated if required) (with or without mixing valves) and a hot water circuit. Can be used with a single boiler in addition to the basic function of the boiler and in addition to the connection of an AGU 2.500, i.e. allowing control of up three or four heating circuits. Can also be used in conjunction with a multiple boiler installation by connection to a RVA47 Cascade Manager. RVA 47 A Cascade Manager with capability to control up to 12 boilers plus a heating circuit (weather compensated if required) and a hot water circuit. Note an OCI 420 Clip-in Module is required in each boiler of a multiple boiler installation for bus communication purposes. QAA 70 Remote Room Unit with similar features to the QAA73 Unit described above, but for use in conjunction with an RVA 47 or RVA 63.20 controllers. QAA50 Room sensor with temperature adjustment, can be used as an alternative to the QAA 70 described above. QAA10 Room sensor which can be used as an alternative to the QAA 70 unit described above. Provides tamper-proof room temperature sensing. QAZ36 Hot Water Temperature Sensor for use with a standard boiler or QAZ21 for use with the RVA47 and RVA63.20 Controllers. For specific details on controls applications see the boiler installation manual or contact MHS. 10

Hydraulic schemes Typical single Ultramax PB (standard version) boiler schematic Outside Air Sensor QAA73 Room Unit or Room T/Stat Heating Circuit AAV Ultramax PB (Standard Version) Pump Inbuilt SV Low Velocity Mixing Header Max. Velocity 0.5m/s Indirect Hot Water Calorifier Strainer Cyl. Stat or Sensor Condense Waste FP LSV Expansion Vessel PU LSV Fig.1 Typical scheme for single Ultramax PB boiler with inbuilt optional low loss header or boiler protection plate heat exchanger Outside Air Sensor Ultramax PB with inbuilt low loss header or boiler protection plate heat exchanger SV QAA73 Room Unit or Room T/Stat Heating Circuit Indirect Hot Water Calorifier Note: Boilers equipped with optional boiler protection plate heat exchanger must be provided with (temporary) provision for filling to fill point located within boiler casing Strainer Cyl. Stat or Sensor Condense Waste FP LSV Expansion Vessel PU LSV Fig.2 Typical multiple Ultramax PB installation schematic. If using RVA47 Cascade Manager + OCI420 Communication Clips within boilers from MHS - up to 12 boilers may be controlled Outside Air Sensor Condense Waste Condense Waste SV RVA 47 Cascade Manager Boiler Primary Pump QAA70 Room Unit or Room T/Stat AAV Low Velocity Mixing Header Max. Velocity 0.5m/s Strainer Heating Circuit Indirect Hot Water Calorifier Cyl. Stat or Sensor Note: Boilers equipped with optional boiler protection plate heat exchanger must be provided with (temporary) provision for filling to fill point located within boiler casing * Boiler primary pump - only required when boilers are equipped with boiler protection plate heat exchangers FP LSV Expansion Vessel PU LSV Fig.3 11

BOILERS 3 Juniper West, Fenton Way, Southfields Business Park, Basildon, Essex SS15 6SJ Tel: 0126 546700 Fax: 0126 250 www.mhsboilers.com This publication is issued subject to alteration or withdrawal without notice. The illustrations and specifications are not binding in detail. All offers and sales are subject to the Company's current terms and conditions of sale. RC/040/5911