COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

Similar documents
Compliance without compromise Safety without sacrifice

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance.

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Fluke-Direct.com

Safety requirements for voltage testing instruments

Arc Flash Protection Training - NFPA 70e Electrical Safety

INSPECT & MONITOR 24/7 SOLUTIONS FOR ELECTRICAL CABINETS. IR Windows & AX8 Thermal Imaging Temperature Sensor

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

INFRARED WINDOW SERIES

May is National Electrical Safety Month, an AND THE ELECTRICAL INSPECTOR. by Mark Hilbert and Laura L. Hildreth

NFPA 70E Elevates Safety. with Heightened Risk Awareness

The safe way to verify the absence of voltage.

VeriSafe Absence of Voltage Tester The safe way to verify the absence of voltage

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

IMPROVE SAFETY WITH ARC FLASH LABELING COMPLY WITH THE 2015 NFPA 70E REGULATIONS

HESNI ANNUAL CONFERENCE May 3, 2012 Aramark Conference Center, Downers Grove

SEL Arc-Flash Solutions

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

White Paper. OSHA and NFPA 70 Understanding NFPA 70 and its. Implications in Electrical Inspections Abstract: iriss.com

NFPA 70E Electrical Safety & Arc Flash Training

NFPA 70E Electrical Safety in the Workplace

Arc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

Guide to Compliance with the Electrical Workplace Safety Standards in the United States

SEL Arc-Flash Solutions

Arc Fault Detection Devices (AFDDs) Protecting People and Property

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

Electrical Safety Compliance: NFPA 70E

CAP Series ,,,,, The Clear Choice. CAP Series Features: Who Says Infrared Windows Have to be Round? Certifications:

62 MAX/62 MAX + Infrared Thermometer

HOW-TO CONDUCT A WEEKLY SAFETY MEETING

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

62 MAX/62 MAX + Infrared Thermometer

NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In?

NFPA 70E. Electrical Safety in the Workplace. KTR Associates. Joseph Deane, PE. Engineering Solutions

700G Series. Pressure Gauge. Safety Information

How to reduce exposure to arc flash hazards

MT4 MAX/MT4 MAX + Infrared Thermometer

New Recognition Certification for Access Hardware INDUSTRY ARTICLE

Professional Seminar. The Electrically Safe Workplace. Understanding the NFPA 70E Electrical Safety Standard, 2012 Edition ...

2012 Edition. Tech Topics: Standards & Codes. Note 4, Issue 1. Points of Interest: Introduction. Background. Changes to Definitions in Article 100

Arc Flash Codes & Compliance: What You Need to Know to Deliver Both Protection and Performance

HOW TO CHOOSE THE RIGHT PROTECTION FOR FIRES, FLASH FIRES & ARC FLASHES

The Basics Arc Flash Protection

IR Viewing Windows and Arc Ratings Dispelling the myth of Arc-Resistant IR Viewing Windows

Protection for the Industry that Powers the Planet

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

You work hard on your panel. we work hard in your panel. PRODUCTS FOR

Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our

Product Specifications 480 VAC, 175A Main Power Distribution Panel

Predictive Maintenance Training

IEEE Std IEEE Recommended Practice for Electrical Installations on Shipboard Safety Considerations

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

Promoting Electrical Safety through NFPA 70E Standards Adherence

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

Designed for testing three-phase circuits up to 600V Install on line or load side of electrical disconnect Detects absence of AC and DC voltage

Faster and smarter ways to protect what matters most. Our Next Generation portfolio

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

PROTECTING AGAINST ARC FLASH HAZARDS

NFPA 70E Edition Update

Regional Training. Seminar. » EasyPower Hands-On» Protective Device Coordination» Arc Flash Hazard Analysis. March 12-16, 2018 Austin, TX

Infrared Windows and Arc Ratings: Dispelling the Myth of Arc-Resistant IR Windows

Dräger QuadGard Control System

GARN WHS 3200 Addendum to the Owner s Manual

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

Electrical Safety for Facility Managers and Building Owners

Users Manual. Air Velocity Meter

Dräger PIR 3000 Detection of flammable gases and vapours

Halyester Totally insulated enclosure system. Degree of protection up to IP66. Product Aid. Multifunctional Enclosure Systems for all Environments

COMBUSTIBLE DUST HAZARD RECOGNITION

64 Max IR Thermometer

Product Specifications 480 VAC, 70A Main Power Distribution Panel

POINT HELIDECK LIGHTS PRL-LSM LED v4 LOW SURFACE MOUNT LIGHT

Eldon Product Overview

Protection from Electric Shock and Arc Flash. Meeting OSHA Regulations and NFPA 70E Standards.

Product Specifications Auto Restart Main Power Distribution Panel

Contractor Safety. Workplace Safety & Environmental Division

How to spot and address potential process problems using thermal imaging

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

Infrared Thermometer

Directive on Laser Safety. NRC Occupational Safety and Health Manual

A Powerful Case for Infrared Windows

ONTARIO Electrical Safety Report. 10th Edition

Brian McCauley December 2017

Product Specifications MaxLumen MRI LED Diffused Lighting

NFPA 70E STANDARD FOR ELECTRICAL SAFETY IN THE WORKPLACE 2012 Edition

Product Specifications Linear Accelerator Relay Junction Box

Safety Meeting Topic #37 NFPA 70E What is it?

Infrared Thermometer. Getting Started

Dräger REGARD -1 Control System

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

Sioux E-Series. All-Electric Compact Industrial Steam Cleaners & Pressure Washers. Sioux E-Series All-Electric Steam Cleaners and Pressure Washers

The Signal Is Clear TM

NFPA 70E Arc Flash Considerations for MV Equipment. By: Dominik Pieniazek, P.E. HV Engineering, LLC

Transcription:

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER ClirVu Series IR Windows

Safety shouldn t be secondary If Fluke has learned anything in more than 65 years, it s not to compromise quality in order to beat a competitor s price. Asking, How well can we make it? versus How cheaply can we make it? may not win price wars, but it has established Fluke as the standard of excellence, and the preferred name in test and measurement equipment. Every time you open a panel cover, you expose yourself to the potential dangers of arc flash. 99.9 % of all arc flash incidents occur when the panel door is opened. Eliminate that risk with ClirVu IR windows. Compliance. The future is clear. Better safe than sorry, is becoming a modern mantra for companies who want protection from the physical and economic tragedies that can result from arc flash incidents. If there s ever a problem, it won t be a question of whether or not you ve done the minimums, but whether you ve done as much as possible to protect your people. With Fluke IR Windows comes the confidence that when it comes to the safety of your people, you have not compromised. 1

Fluke ClirVu IR Windows Not just a better window a clearer view. The solution Don t open the panel door. Once a ClirVu IR Window is installed, there s no more need to power down or remove panels you may never have to open the panel door again. Inspections are conducted quickly, easily, and of course, safely. Decreasing risks of arc flash may also result in lower insurance costs. Your greatest investment is not what s behind the panel, so when Fluke made the decision to manufacture infrared windows, our priority was to offer the ultimate protection for the electricians, engineers and inspectors who risk their lives doing their jobs. At the same time, the quest for safety has led to numerous technological advancements resulting in faster installation and inspections. It s safe to say, ClirVu is all you need to be both compliant and more productive at your job. www.fluke.com/irwindows 2

When a product far exceeds the minimum safety and performance standards, that s confidence. That s Fluke Fast installation with AutoGround design less than 5 minutes. Yes, five minutes. That s about how long it takes to install a Fluke ClirVu CV Series IR Window, the only IR Window with AutoGround. With its AutoGround design, Fluke has eliminated the need to separately ground each metal component of the window. The time saved and safety benefits from installation alone clearly make Fluke the preferred choice. Torture Tested to the highest arc blast test ratings IEEE C37.20.7: 63 ka Arc tested at KEMA UL 50/50E/50V, UL1558, IEC60529-1: IP67, IEC 60068, NEMA 4/12, CSA C22.2 NO. 14-13:2012, and CE Grounds instantly to metal enclosure with patent-pending AutoGround process Maintains panel arc test ratings up to 63 ka when properly installed Convenience at the turn of a key ClirVu IR Windows are designed with hinged covers that can be easily opened with the quarter turn latch or key to perform an infrared inspections. The covers also protect the windows from accidental exterior impact. 3

It s time Save time with quick and easy installation 5 minutes or less! One technician One hole with standard Greenlee punch Panel door does not need to be removed Grounds instantly to metal enclosure with patent-pending AutoGround process Maintains panel arc test ratings up to 63 ka when properly installed 1 2 Lock out tag out Can you afford not to install ClirVu IR Windows? Arc flash accidents can cost an employer in excess of a million dollars. Lost production, equipment and facility repair and replacement may just scratch the surface of costs. There s always the potential for lawsuits, skyrocketing insurance premiums, and staggering fines from OSHA (or other occupational safety bodies around the world). Of course, the monetary costs are overshadowed by serious injuries, or the loss of a valued employee s life. Fluke ClirVu IR Windows gives you and your company an extra layer of protection to avoid the tragedy of an arc-flash incident. Punch hole 3 Attach and secure cover Watch the video at fluke.com/install www.fluke.com/irwindows 4

The line 100 mm (4 in), 75 mm (3 in) and 50 mm (2 in) 50 mm (2 in) Fluke ClirVu IR Windows are Torture Tested From a northern Canadian winter to a California desert to the corrosive conditions of offshore oil rigs and anywhere in between, you can count on ClirVu IR Windows to stand up to the challenge. No more removing the panel door for installation. A significant reduction of work permit requirements and NFPA 70E processes are now in your future Full PPE is often not required so inspections are done faster and more comfortable Built to the highest arc blast protection (63 ka arc tested): High temperature silicon gaskets Mounting and door latches provide high pressure gasket compression Die cast components are manufactured with the highest strength alloys Jam nut screws are made from 4037 steel, heat treated to 160,000 psi tensile Torture Tested to the highest test ratings IEEE C37.20.7 63 ka Arc tested at KEMA, UL 50/50E/50V, UL1558, IEC60529-1: IP67, IEC 60068, NEMA 4/12, CSA C22.2 NO. 14-13:2012, and CE Corrosion and UV resistance for challenging outdoor environments 75 mm (3 in) 5 95 mm (4 in)

Hierarchy of controls Occupational Health and Safety Organization (OSHA) and the National Fire Protection Association (NFPA) recommend the system of Hierarchy of Controls to minimize or eliminate exposure to occupational hazards. OSHA and NFPA are United States organizations but the Hierarchy of Controls concept is relevant worldwide. Most effective Elimination/substitution removes a hazard all together or controls a hazard by substituting something in its place that would be non-hazardous or less hazardous. Engineering controls physical changes or modifications designed to eliminate or reduce hazardous exposure to equipment or a work environment. This is the preferred method for eliminating and reducing workplace hazards. Safe work practice controls safe work practices are designed to change the way a job is performed to remove the employee from exposure to the workplace hazard. Administrative controls changes to include additional backup workers, breaks and the rotation of workers to reduce exposure to work hazards. Personal protective equipment protective equipment or clothing worn by employees to reduce injuries or exposure to hazardous or toxic substances. IR Window installations fall into this category Arc flash facts Least effective The arc flash itself can achieve temperatures in excess of 35,000 F. Source: National Fire Protection Association Approximately 2,000 workers will be admitted to hospital burn units this year due to thermal burns from arc flash or arc blast accidents. Source: National Fire Protection Association 5 to 10 arc flash explosions occur every day in the US. Source: CapShell, Inc. www.fluke.com/irwindows 6

Specifications Model CV400 CV401 CV300 CV301 CV200 CV201 CLKT Size 95 mm (4 in) 75 mm (3 in) 50 mm (2 in) 100 mm, 75 mm and 50 mm (4, 3 and 2 in) General Voltage range Any Any NEMA environment type Type 4/12 (indoor/outdoor) Type 3/12 AutoGround Yes Yes ClirVu Optic Yes Yes Operating temperature Ratings and testing Arc-tested (IEEE C37.20.7) UL 50 V component recognition UL 50/NEMA environmental rating -40 C to +232 C (-40 F to +450 F) and +260 C (500 F) intermittent -40 C to +232 C (-40 F to +450 F) 63 ka for 30 cycles @ 60Hz at KEMA 50 ka for 30 cycles @ 60 Hz at KEMA Yes NEMA Type 4/12 NEMA Type 3/12 UL1558 Yes No CSA C22.2 No. Yes Yes CSA type rating Type 4 Type 3/12 IP rating IP67 at TUV IP55 Lloyds Register Up to 11 kv marine switchgear, indoor or outdoor (offshore only) Vibration rating IEC60068-2-6 at TUV IEC60068-2-6 Humidity rating IEC60068-2-3 at TUV IEC60068-2-3 Install Actual mounting hole diameter required Greenlee Punch Kit = Punch / Die 115.42 mm (4.544 in) 89.89 mm (3.539 in) 61.37 mm (2.416 in) 742BB = 2984AV / 2983AV 739BB = 1431AV / 1432AV 76BB = 441AV / 442AV Yes 50 mm 43.2 mm (1.7 in); 75 mm 69.9 mm (2.75 in); 100 mm 92 mm (3.62 in) 50 mm 06974/04013; 75 mm 04247/04246; 100 mm Hole Saw Only Door Latch Hand Turn Security Key Hand Turn Security Key Hand Turn Security Key Hand turn Optics Optic insert diameter 95 mm (3.74 in) 75 mm (2.96 in) 50 mm (1.97 in) 100 mm, 75 mm and 50 mm (4, 3 and 2 in) Warranty Lifetime replacement against manufacturing defects For more detailed specifications download datasheets at www.fluke.com/irwindows Fluke. The Most Trusted Tools in the World. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands Web: www.fluke.co.uk For more information call: In Europe/M-East/Africa +31 (0) 40 2 675 200 or Fax +31 (0) 40 2 675 222 Fluke (UK) Ltd. 52 Hurricane Way Norwich, Norfolk NR6 6JB United Kingdom Tel.: +44 (0) 20 7942 0700 Fax: +44 (0) 20 7942 0701 E-mail: industrial@uk.fluke.nl Web: www.fluke.co.uk 2006-2013 Fluke Corporation. All rights reserved. Data subject to alteration without notice. 10/2013 Pub_ID: 12099-eng Modification of this document is not permitted without written permission from Fluke Corporation.