How to deal with ...R410A MITSUBISHI ELECTRIC R32 R125 R410A AIRCONDITIO NING

Similar documents
Chapter 2. Alternatives to HCFCs and their Characteristics

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

14. The center port of the manifold is used for evacuation, charging and refrigerant recovery.

COLD. Basic Training Course II. November ESSE - Wilhelm Nießen

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

This chapter is devided into two sections:

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Some of these procedures need to be performed to conform to requirements of the Clean Air Act.

Responsible Care Product Stewardship for Refrigerants

Refrigerant Glide and Effect on Performances Declaration

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Practical Fundamentals of Heating, Ventilation and Air Conditioning (HVAC) for Engineers and Technicians

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

REFRIGERANT CHANGEOVER

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

High Efficiency Technologies for Small and Medium-Sized Air Conditioning Equipment Using R410A. Hitachi Appliances, Inc.

Refrigeration air dryer

General. Applications and Accessories for Oil Diffusion Pumps. leybold. Application. Accessories LEYBOJET 630 DIP DIP DIP DIP 30000

Energy Use in Refrigeration Systems

R-407A R-448A R-449A

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

A Comparison Between Refrigerants Used In Air Conditioning

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

The First 100+ Terms

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

Repair instruction and handling for Isobutane (R600a) refrigerant.

Chapter 10. Refrigeration and Heat Pump Systems

CHAPTER 1 INTRODUCTION

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Design of LPG Refrigeration System

1 TECHNICAL CHANGES. MUZ-A09NA MUZ-A09NA - 1 MUZ-A09NA - U1 MUZ-A09NA - U2 1. Refrigerant system diagram has been changed.

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

REFRIGERATION DRYERS OP 05 - OP 190

Thermodynamics I. Refrigeration and Heat Pump Cycles

Chapter 9. Refrigeration and Liquefaction

B. A. T. Basic Appliance Training

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Sarthak Thakar, 2 R.P.Prajapati 1

Natural refrigerants - naturally efficient

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Chapter 10 Lyes KADEM [Thermodynamics II] 2007

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

Ammonia. Background on ammonia as a refrigerant

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Compressed air preparation Compressed air storage Moisture management. Catalog #1

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

HVAC Fundamentals & Refrigeration Cycle

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

The Essentials Of Working With R-410A

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Refrigerant trends especially focusing on CO 2

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Refrigeration Technology in Building Services Engineering

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Purpose of Refrigeration

Transcritical CO2 Bottle Cooler Development

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 10 SYSTEM CHARGING

ROCOOL For commissioning, maintenance work and documentation of refrigeration systems of all kinds An absolute all-rounder due to the unique

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Refrigerants and lubricants

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Vacuum Switch, Differential Pressure Adapter, Switching Amplifier

CHAPTER 1 INTRODUCTION

F Series - Refrigeration dryers

BOGE AIR. THE AIR TO WORK. Refrigerant Dryers RA Series

Cooling Fundamentals

SERVICE ON HOUSEHOLD REFRIGERATORS & FREEZERS

UEE11 Electrotechnology. Training Package. UEENEEJ108A Recover, pressure test, evacuate, charge and leak test refrigerants SAMPLE.

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Refrigeration and Air-Conditioning

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

March 10, 2016 San Joaquin Valley RETA Meeting

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Scroll Chillers Transition from HCFC-22 to HFCs

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

Commercial Refrigeration

HIGH QUALITY VAPOR PHASE REFLOW SOLDERING. SMTA Arizona-Sonora December 4th 2012

Hybrid Conversion Kit Procedure Guide

A Review Paper on Comparative Study of Household- Refrigerator with Alternative Low Global Warming Potential Refrigerants

Case 15 Refrigeration System for Chemical Fertilizer Plant Ammonia Storage

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

O NEof Premium tools for professionals!

Refrigeration Cycle Demonstration Unit R633

LPG Refrigerator. October 2017 IJIRT Volume 4 Issue 5 ISSN:

Chapter 11 REFRIGERATION CYCLES

Evaluation and Development of Air-conditioners using Low GWP Refrigerant

Transcription:

How to deal with R32 R125 R410A...R410A MITSUBISHI ELECTRIC AIRCONDITIO NING

R410A Contents What is R410A?......................................... 3 Expressions........................................... 4 Properties............................................ 5 Copper pipe work....................................... 6 Proper evacuation....................................... 7 The texts, illustrations, diagrams and examples in this manual are only intended as help for the handling and proper use of the refrigerant R410A. All information contained in this brochure was carefully researched and checked. If you have any questions regarding the installation and operation of the equipment described in this manual, please do not hesitate to contact the following address: MITSUBISHI ELECTRIC EUROPE B.V. AIR CONDITIONING GOTHAER STR. 8 D-40880 RATINGEN Phone: ++49 2102 / 486-1800 Fax: ++49 2102 / 486-7910 www.mitsubishi-electric-aircon.de All rights reserved. No part of this manual may be reproduced, stored in a retrieval system or transcribed, in any form or by any means electronic, mechanical, photocopying, recording or otherwise without express prior permission in writing from MITSUBISHI ELECTRIC EUROPE B.V. MITSUBISHI ELECTRIC EUROPE B.V. reserves the right to change the specifications of its products and/or the contents of this manual at any time and without prior notice. Editorial Responsibility Art. no. XXXXXX Michael Lechte 11/2002 2

What is R410A? R410A What is R410A? R410A is a refrigerant that was developed as a substitute for R22 and R13 B1. R410A is nearly azeotropic and is a mixture of equal parts of R32 and R125. In practical terms, R410A has the same properties as R22. The refrigerant R407C has no ozone depletion potential (ODP). Because of the relatively high density and the high energetic efficiency it is possible to reduce the size of device components (condenser / compressor unit, the evaporator part, piping, etc.). The very high condenser pressures compared to the R22 (R22: 43 C, 15.8 bar; R410A: 42 C, 26 bar) prevent the conversion of older systems to R410A refrigerant. Because all components such as compressors, liquefiers, collectors, evaporators, piping, etc. must all be designed or developed to withstand these high pressures. As refrigeration equipment oil an ester oil is used, as was the case prior to the introduction of R407C and with other refrigerants. During installation there are no special points that need to be observed in comparison to R407C refrigerant. Just as a reminder, here are the most important points again: Always work with absolute cleanliness! Solder only under safety gas! Evacuate the system properly! Always fill the system exclusively with fluid! 3

R410A Expressions Expressions ODP Ozon Depletion Potential The Ozone Depletion Potential of R11 was standardized to 1. There is no unit or measurement for ODP, only comparative classifications. R410A has an ODP of 0, therefore no ozone depletion potential. GWP Global Warming Potential The Global Warming Potential indicates the ability of a gas to store energy as well as the residency period of the gas in the atmosphere. As a basis for comparisons carbon dioxide [CO2] is used. CO2 resides in the atmosphere for over 500 years. The GWP100 refers to a 100 year residency period. If other periods of time are selected, then it is indicated by a footnote (e.g. GWP20). 4

Properties R410A Properties R410A an azeotropic mixture: The refrigerant R410A is a mixture of refrigerants that was developed as a substitute for CFC, e.g. R22 and R502. R410A is a mixture (or blend) of: R32 60% R125 40% Properties of azeotropic mixtures: In contrast to R407C (zeotropic mixture) the phase change of azeotropic mixtures takes place at almost constant temperature during the liquefaction or evaporation process. So R410A has a negligibly small temperature glide. Pressure [bar] Isotherms Pc Isobars Po tg 0 ~ Enthalpy [kj/kg] tg = temperature glide, for R410A nearly 0 K 5

R410A Copper pipe work Copper pipe work Use only copper pipes complying with DIN (German Industrial Standards) regulations. Cut the piping only with a pipe cutter. Remove burrs with care. Make sure that no swarf or other impurities get into the piping. Solder joints must be bare and clean. Do not clean the pipe connections with emery paper as this leaves traces on the soft surface of the copper. Solder flows best on smooth surfaces. To clean the copper pipes use steel wool or a cleaning fleece. Ensure that solder joints are made only using safety gas. Use dry nitrogen or forming gas. During soldering without a safety gas, oxygen can get to the solder joint and copper oxide is produced at the pipe surface. The copper oxide is washed off the surface of the pipe once the refrigerator is put into operation and it then circulates with the refrigerant. Due to the high compressor final temperature, the oxides can cause the refrigerant and refrigeration unit oil to decompose. The result is defects in operation. 6

Proper evacuation R410A Proper evacuation A decisive factor for the problem-free operation of the air-conditioning system is proper evacuation of the cooling system. Through the evacuation air and moisture are removed from the piping and all system components. Why do refrigeration systems have to be evacuated? Through the evacuation the following harmful effects are prevented: Foreign gas collects in the condenser. That causes the pressure in the condenser to increase and the compression temperature to rise. Moisture leads to undesirable reactions in the refrigerant circuit and can result in the injection valve icing up. The polyester oils used in the R410A refrigeration units are hydroscopic, i.e. they take up moisture from the air. Moisture (water) must be removed at all costs to prevent chemical reactions in the system (hydrolysis). Hydrolysis products are polyvalent alcohols and carboxylic acids. Air (oxygen) reacts with the refrigeration unit oil and may lead to faults (e.g. compressor failure). To be able to remove water from the system it must be evaporated. For that the pressure in the piping must be reduced to such an extent that the ambient temperature is sufficient to evaporate the water. 7

R410A Proper evacuation The boiling point By way of example: the boiling point of water at sea level is 100 C. However, at a height of 4800 m and an atmospheric pressure of 555 mbar the boiling point has fallen to 84 C. Therefore, in this case it means, depending on the season, attaining a pressure in the piping system that causes the water in the system to evaporate at ambient temperatures of 25 C insummer or at about 5 C at colder times of year. It is evident that in summer it is relatively easy to reach the required pressure. In winter, however, it is hardly possible to evacuate a system properly. The boiling point is dependent on the pressure being exerted on the fluid. The higher the pressure, the higher is the boiling temperature; the lower the pressure, the lower is the boiling point. Steam pressure curve t Ps 5 C 0,009 bar 10 C 0,012 bar 15 C 0,017 bar 20 C 0,023 bar 25 C 0,042 bar To know what pressure has to be attained to cause the fluid in the system to evaporate at the corresponding ambient temperature, a glance at the adjacent table should suffice: At an atmospheric temperature of 15 C the refrigerant circuit must be evacuated to a minimum of 0.017 bar to obtain system drying. 8

Proper evacuation R410A The right tools The right tools are required to enable the refrigeration system to be properly evacuated and dried. These include: Selection of the vacuum pump The right pressure gauge Selection of vacuum measuring instruments Selection of the right vacuum pump In order to attain these low vapor pressures a modern vacuum pump is required. The required pumping capacity of the pump Sv depends on the size of the air-conditioning unit: small air conditioners Sv = 1 m³/ h up to 2.5 kw cooling capacity small and middle air conditioners Sv = 4 8 m³/ h from 2.5 up to 11 kw cooling capacity big air conditioners Sv = 8 15 m³/ h above 11 kw cooling capacity A one or two-step rotary slide valve vacuum pump should be used. Its pumping performance is down to approx. 0.3 mbar for one-step and approx. 0.05 mbar for the two-step vacuum pump. 9

R410A Proper evacuation The pressure gauge The low pressure gauge mounted on the pressure gauge is not suitable for measuring vacuum. One cannot rely on conventional displays when determining the pressure attained in the system. In areas of low pressure they are too inaccurate and hard to read because of their small dimensions. Use an absolute vacuum measuring meter for determining the vacuum. Suitable vacuum measuring gauges To determine accurately the pressure in the system and whether the desired vacuum has been attained a vacuum or torr meter is indispensable. A professional evacuation requires such an instrument. 10

Proper evacuation R410A Handy tips for evacuation Before a system evacuation can be undertaken a check for potential leaks is absolutely essential. Such leaks may be discovered at soldering joints or flange screw connections. The evacuation can only start once the system has been properly pressure tested and found to be leakproof. In the case of large systems it is recommended to break the vacuum. That means, at a pressure of about 12 mbar to fill the system with dried nitrogen and then to re-evacuate it again. This causes the residual water vapour in the piping to be diluted and enables it to be pumped out more easily. In order to save time, evacuation should be carried out simultaneously on the suction and pressure sides. Also the use of tubes that are as short and of large a diameter ( 1 / 2 ") as possible saves time as well. Conclusion If you follow closely the few instructions in this small brochure and always work cleanly, just as you have learnt in training, you will have no problems in handling the refrigerant R410A. Satisfied customers will be grateful to you. 11

MITSUBISHI ELECTRIC AIRCONDITIO NING MITSUBISHI ELECTRIC EUROPE B.V. AIR CONDITIONING DIVISION, GOTHAER STR. 8, D-40880 RATINGEN www.mitsubishi-electric-aircon.de Specifications subject to change without notice. Printed in Germany 11/2002 Art.no. 148033