DIVISION FINNED WATER-TUBE BOILERS

Similar documents
DIVISION FINNED WATER-TUBE WATER HEATERS

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

Proudly assembled in U.S.A

Proudly assembled in U.S.A

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

Less Than.25% Lead Proudly Assembled in the U.S.A

Less Than.25 Pb Proudly made in the U.S.A

Less Than.25% Lead Proudly Assembled in the U.S.A

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Proudly assembled in U.S.A

Suggested Specifications Prestige Excellence 110

Models HD101 thru 2342B

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

AFUE 95% Heating Input 50,000 to 200,000 Btuh

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube water heaters for heating hot water.

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Models HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb. Proudly made in U.S.A

97% Thermal Efficiency

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Revitalize Building Mechanical Systems (4619)

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube boilers for heating hot water.

C1050ES Tankless Water Heater

Power Flame Incorporated

TABLE OF CONTENTS BRADFORD WHITE BOILERS

Project Name: Location: Engineer: Contractor: I. GENERAL

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Triton Series High Efficiency Boiler

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

New Versa IC Platform

SECTION SAMPLE SPECIFICATION FOR BOILER CONTROLLER CONVERSION KIT

940ES Tankless Water Heater

Hubbell NX500 High Efficiency Gas Condensing Water Heater

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

940ES Tankless Water Heater

Automatic Circulating Water Heaters

C1210ES Tankless Water Heater

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

SECTION HEATING BOILERS

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

CONDENSING HIGH EFFICIENCY BOILERS

High Efficiency Commercial Gas Water Heaters

Date: Project #: Engineer: Prepared By: Bid Date:

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

CAMUS ADVANTUS BOILERS

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Power Flame Incorporated

HIGH EFFICIENCY COMMERCIAL BOILERS

HCLEARFIRE. High-efficiency, modular steam boiler HP

SECTION WATER-TUBE BOILERS

FLEXCORE SERIES MASTERSPEC

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Honeywell SLATE ICM Platform

Originators of the Flexible Water Tube design

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Boiler & Water Heater

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

KN2/4 SERIES MASTER SPECIFICATION

Originators of the Flexible Water Tube design

Get The Edge Over The Competition with The Summit

Boilers Variable Fire Boilers

Raypak Residential Products

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

Transcription:

HI DELTA, TYPE H - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 2000.953 Effective: 10-31-16 Replaces: NEW DIVISION 23 52 33.13 FINNED WATER-TUBE BOILERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired, copper finned-tube hydronic heating boilers B. Related Sections Specifier Note: Use as needed 1. Building Services Piping Division 23 21 00 2. Breeching, Chimneys, and Stacks (Venting) Division 23 51 00 3. HVAC Instrumentation and Controls Division 23 09 00 4. Electrical Division 23 09 33 1.2 REFERENCES A. ANSI Z21.13/CSA 4.9 B. ASME, BPV Section IV C. 2006 UMC, Section 1107.6 D. ANSI/ASHRAE 15-1994, Section 8.13.6 E. National Fuel Gas Code, ANSI Z223.1/NFPA 54 F. I=B=R G. National Electrical Code, ANSI/NFPA 70 H. ASME CSD-1-2012 (when required) 1.3 SUBMITTALS A. Product data sheet (including dimensions, rated capacities, shipping weights, accessories) B. Wiring diagram C. Warranty information D. Installation and operating instructions 1.4 QUALITY ASSURANCE A. Regulatory Requirements 1. ANSI Z21.13/CSA 4.9 2. Local and national air quality regulations for low NOx (< 20 PPM NOx emissions) boilers B. Certifications 1. CSA 2. ASME H Stamp and National Board Listed 1.5 WARRANTY A. Limited one-year warranty from date of installation B. Limited twenty-year thermal shock warranty C. Limited ten-year closed-system heat exchanger warranty - PRODUCTS 2.1 MANUFACTURER A. Raypak, Inc. 1. Contact: 2151 Eastman Ave., Oxnard, CA 93030; Telephone: (805) 278-5300; Fax: (800) 872-9725; Web site: www.raypak.com Project Name / Date Division 23 52 33.13-1

2.2 BOILERS 2. Product: Hi Delta copper finned-tube hydronic boiler(s) A. General 1. The boiler(s) shall be fired with gas at a rated input of BTU/hr. 2. The boiler(s) shall be CSA tested and certified with a minimum thermal efficiency of 84 percent at full fire. 3. The boiler(s) shall be ASME inspected and stamped and National Board registered for 160 PSIG working pressure, complete with a Manufacturer's Data Report. 4. The boiler(s) shall have a floor loading of 65 lbs. /square foot or less. B. Heat Exchanger 1. The heat exchanger shall be of a single-bank, horizontal-grid design with twelve integral copper-finned tubes, each end of which is rolled into an ASME boiler-quality steel tube sheet. 2. The heat exchanger shall be sealed to 160 PSIG-rated cast-iron glass-lined headers with hightemperature silicone "O" rings. 3. The low water volume heat exchanger shall be explosion-proof on the water side and shall carry a twenty-year warranty against thermal shock. 4. The headers shall be secured to the tube sheet by stud bolts with flange nuts to permit inspection and maintenance without removal of external piping connections. 5. The boiler(s) shall be capable of operating at inlet water temperatures as low as 105 F without condensation. 6. The boiler(s) shall be designed to accommodate field changes of either left or right hand plumbing and electrical while leaving the tube bundle in place. C. Burners 1. The tubular burners shall have multiport radial gas orifices, punched ports and slots, be capable of quiet ignition and extinction without flashback at the orifice, and be manufactured from corrosion-resistant, titanium-stabilized stainless steel with low expansion coefficient. 2. The burners will be supplied with a fan-assisted, clean burning, and highly efficient fuel-air mixture. D. Ignition Control System 1. The boilers(s) shall be equipped with a 100 percent safety shutdown. 2. The ignition shall be Hot Surface Ignition type with full flame rectification by remote sensing separate from the ignition source, with a three-try-for-ignition sequence, to ensure consistent operation. 3. The igniter will be located away from the water inlet to protect the device from condensation during start-up. 4. The ignition control module shall include an LED that indicates fifteen (15) individual diagnostic flash codes and transmits any fault codes to the LCD display. 5. Two external viewing ports shall be provided, permitting visual observation of burner operation. E. Gas Train 1. The boiler(s) shall have a firing/leak test valve and pressure test valve as required by CSD-1. 2. The boiler(s) shall have dual-seated main gas valve(s). 3. Gas control trains shall have a redundant safety shut-off feature, main gas regulator, shut-off cock and plugged pressure tapping to meet the requirements of ANSI Z21.13/CSA 4.9. F. Boiler Control 1. The following safety controls shall be provided: a. Fixed High limit control with manual reset. b. Flow switch, mounted and wired. c. PSIG ASME pressure relief valve, piped by the installer to an approved drain. d. Temperature and pressure gauge. G. The boiler(s) shall be equipped with the Versa IC temperature controller with LCD display that incorporates an adjustable energy-saving pump control relay and freeze protection and is factory Project Name / Date Division 23 52 33.13-2

mounted and wired to improve system efficiency; 4 water sensors included (system sensor and indirect DHW tank sensor are shipped loose). H. Firing Mode 1. For model 992C, provide three-stage firing control of the gas input to the boiler. 2. For models 1262C-2342C, provide four-stage firing control of the gas input to the boiler. I. Boiler Diagnostics 1. Provide external LED panel displaying the following water heater status/faults: a. Power on Green b. Call for heat Amber c. Burner firing Blue d. Service Red 2. Provide monitoring of all safeties, internal/external interlocks with fault display by a 3-1/2 in. LCD display: a. System status b. Ignition failure c. False flame d. Ignition proving current (HSI) e. Field Interlock f. Air pressure switch g. Low 24VAC h. Manual reset high limit i. Blocked vent j. Controller alarm k. Flow switch fault l. Sensor failure I. Inlet sensor (open or short) II. Outlet sensor (open or short) III. System sensor (open or short) IV. High limit sensor (open or short) m. Internal control fault n. ID card fault o. Cascade communications error Specifier Note: The following items are options. Delete if not being specified. p. Low water cut-off q. Low gas pressure switch r. High gas pressure switch s. Controller alarm t. Cold Water Start/Cold Water Run (optional) 3. Factory installed Versa IC ignition and control components for staging control of the boiler. 4. Provide ignition module indicating the following flash codes by LED signal and displayed on LCD display: a. 1 flash low air pressure b. 2 flashes flame in the combustion chamber w/o CFH c. 3 flashes ignition lock-out (flame failure) d. 4 flashes low hot surface igniter current e. 5 flashes low 24VAC f. 6 flashes Vent temperature fault (not used) g. 7 flashes Hi-limit fault h. 8 flashes Sensor fault i. 9 flashes Low gas pressure fault j. 10 flashes Water pressure fault (not used) k. 11 flashes Blower speed fault (not used) l. 12 flashes Low water cut off m. 13 flashes Hi-temperature delta T n. 14 flashes Ft-bus communication fault o. 15 flashes General safety fault Project Name / Date Division 23 52 33.13-3

J. Combustion Chamber: The lightweight, high-temperature, multi-piece, interlocking ceramic fiber combustion chamber liner shall be sealed to reduce standby radiation losses, reducing jacket losses and increasing unit efficiency. K. Venting 1. When routed vertically, the boiler s flue material and size shall be in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA54 latest edition (Category I). (1) When routed horizontally, the boiler(s) flue material and size shall meet or exceed the requirements as specified for Category III in the National Fuel Gas Code, ANSI Z223.1/NFPA 54 latest edition. 2. The boiler(s) shall be ducted combustion air ready. L. Cabinet 1. The corrosion-resistant galvanized steel jackets shall be finished with a baked-on epoxy powder coat which is suitable for outdoor installation, applied prior to assembly for complete coverage, and shall incorporate louvers in the outer panels to divert air past heated surfaces. 2. The boiler(s), if located on a combustible floor, shall not require a separate combustible floor base. 3. The boiler(s) shall have the option of venting the flue products either through the top or the back of the unit. 4. Combustion air intake shall be on the left side of the cabinet (standard), right side optional. Specifier Note: The remaining items in this section are options. Delete those that are not being specified. IMPORTANT: The Cold Water Start and Cold Water Run Systems cannot be used on the same boiler. The Low Gas Supply Pressure and FlexGas Manifolds also cannot be used on the same boiler. M. Boiler Operating Controls A. Each boiler shall have the ability to receive a 0 to 10 VDC signal from a Central Energy Management and Direct Drive Control System (EMCS) to vary the setpoint control. Each heater shall have an alarm contact for connection to a central EMCS system. B. Each boiler shall be equipped with Modbus communications compatibility with up to 146 points of data available. a. B-85 Gateway BACnet MS/TP, BACnet IP, N2 Metasys or Modbus TCP (optional) b. B-86 Gateway LonWorks C. System and indirect DHW sensors shall be shipped loose for field installation by installing contractor. The outdoor air sensor is optional. N. Boiler Pump - Refer to Equipment Schedule O. SureRack Boiler Stacking Kit 1. The boilers shall be stacked directly one on top of the other, without offset, to minimize footprint. P. Cold Water Start System 1. The boiler(s) shall be configured with a cold water start automatic proportional by-pass system that ensures the boiler will experience inlet temperatures in excess of 105ºF in less than 7 minutes to avoid damaging condensation. The unit can automatically shut down if the inlet temperature is not achieved within the 7-minute time frame. 2. The cold water start system shall be configured with a three-way diverting valve that is controlled by the Versa IC software that bypasses the correct amount of cold water directly into the system loop to maintain a minimum inlet temperature. The factory-installed boiler inlet temperature sensor shall be utilized for the cold water start system. 3. The control shall have a temperature setting adjustment located in the Setup menu of the Versa IC Control. The inlet temperature range shall be 105 F to 120 F. The PID Logic shall be capable of limiting system overshoot to a maximum of 10 F on initial start-up or call-for-heat. 4. The cold water start system shall be completely wired and mounted at the factory. 5. The control shall have alarm contacts. Q. Cold Water Run System 1. The boiler(s) shall be configured with a cold water run automatic proportional by-pass system Project Name / Date Division 23 52 33.13-4

that ensures the boiler will experience inlet temperatures in excess of 105 F in less than 7 minutes to avoid damaging condensation. The unit can automatically shut down if the inlet temperature is not achieved within the 7-minute time frame. 2. The cold water run system shall be configured with a variable-speed pump that is controlled by the Versa IC software that injects the correct amount of cold water directly into the system loop to maintain a minimum inlet temperature. The factory-installed boiler inlet temperature sensor shall be utilized for the cold water run system. 3. The control shall have a temperature setting adjustment located in the Setup menu of the Versa IC Control. The inlet temperature range shall be 105 F to 120 F. The PID Logic shall be capable of limiting system overshoot to a maximum of 10 F on initial start-up or call-for-heat. 4. The cold water run system shall be completely wired and mounted at the factory. 5. The control shall have alarm contacts. R. Low Gas Supply Pressure Manifold 1. The boiler(s) shall be CSA certified for full-input operation down to 4.0 WC dynamic inlet natural gas supply pressure. S. FlexGas Dual-Fuel Gas Manifold (not offered on model 2002C) 1. The boiler(s) shall be configured with a patented, CSA-certified gas control system that is capable of operating with natural gas or propane gas in a configuration that does not require mechanical disassembly or adjustment of gas or air components. a. The gas switching shall be accomplished by a three-position electrical switch with an OFF position between the Natural and Propane settings including a positive fuel shutdown in both directions to block back-pressure. b. The FlexGas manifold shall as a minimum have two ON/OFF solenoid shutoff valves for natural gas, and a minimum of one ON/OFF solenoid shutoff valve and a lock-up regulator for propane gas, as a safety feature. c. The FlexGas gas manifold shall be capable of accomplishing the fuel changeover in less than sixty seconds. T. TruSeal Direct Vent 1. The boiler(s) shall meet safety standards for direct vent equipment as noted by the 2006 UMC, section 1107.6, ASHRAE 15-1994, section 8.13.6, and ANSI Z21.13/CSA 4.9. 2.3 SOURCE QUALITY CONTROL A. The boiler(s) shall be completely assembled, wired, and fire-tested prior to shipment from the factory. B. The boiler(s) shall be furnished with the sales order, ASME Manufacturer s Data Report, inspection sheet, wiring diagram, rating plate and Installation and Operating Manual. - EXECUTION 3.1 INSTALLATION A. Must comply with 1. Local, state, provincial, and national codes, laws, regulations and ordinances 2. National Fuel Gas Code, NFPA 54/ANSI Z223.1 latest edition 3. National Electrical Code, ANSI/NFPA 70 latest edition 4. Standard for Controls and Safety Devices for Automatically Fired Boilers, ANSI/ASME CSD-1, when required 5. Canada only: CAN/CSA B149 Installation Code and CSA C22.1 CEC Part I 6. Manufacturer s installation instructions, including required service clearances and venting guidelines B. Manufacturer s representative to verify proper and complete installation. 3.2 START-UP A. Shall be performed by Raypak factory-trained personnel. B. Test during operation and adjust if necessary: Project Name / Date Division 23 52 33.13-5

1. Safeties (2.2 - F) 2. Operating Controls (2.3) 3. Static and full load gas supply pressure 4. Gas manifold and blower air pressure C. Submit copy of start-up report to Architect and Engineer. 3.3 TRAINING A. Provide factory-authorized service representative to train maintenance personnel on procedures and schedules related to start-up, shut-down, trouble shooting, servicing, and preventive maintenance. B. Schedule training at least seven days in advance. END OF SECTION Project Name / Date Division 23 52 33.13-6