Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

Similar documents
Models Series Series

Models Series Series

Model Series Series

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

FLANGE-MOUNT CENTRIFUGAL PUMPS

316 Stainless Steel Close- Coupled Self-Priming Flexible Impeller Pumps

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

CLOSED COUPLED CENTRIFUGAL PUMPS

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

17 U.S. gallon portable low profile drain with electric pump

SHURFLO 316 STAINLESS STEEL CLOSE-COUPLED SELF-PRIMING FLEXIBLE IMPELLER PUMPS OPERATION INSTRUCTIONS, PERFORMANCE, SPECIFICATIONS & PARTS MANUAL

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

12 Impeller Replacement

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

Model: Series. PumpAgents.com - buy pumps and parts online. DESIGNER STYLED MARINE TOILET With Integral Bowl Rinse Water/Waste Evacuation Pump

SHURflo Bronze Pedestal Self-Priming Flexible Impeller Pumps

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Specifications Information and Repair Parts Manual 316A-95, 316B-95, 393A-95, 393B A-95 thru 394D-95, 399A-95

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S12 S16

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

Series P. Installation & Maintenance. Materials: A - CPVC B - Polypropylene C - PVDF

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

568X, 587X, 588X Series

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

MECHANICAL SEAL REPLACEMENT UNPACKING MAINTENANCE. Figure 1 & 2 - Mechanical Seal Replacement

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

REF. NO Clamp Assembly 8 1 set Gasket (4 per set) S.S. Lock-washer 3/8 x 1/ Brass Impeller 3.

489 & 490 Series CAST IRON UNITS BRONZE UNITS STAINLESS STEEL UNITS MAINTENANCE. Figure 1 - Mechanical Seal Replacement

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

Model 53 Macerator Pump Installation, Operation, Repair Manual

5. CONDENSATE PUMPS/UNITS

SERIES ES BASE MOUNTED TURBINE PUMPS

DUPLEX CONDENSATE TANK SYSTEM

The Marine Throne. Model TMT S/37045/X-Series QUIET - FLUSH ELECTRIC TOILET. "all the comforts of home" FEATURES SPECIFICATIONS INSTALLATION

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

SPARUS 160 ENERGY EFFICIENT AQUACULTURE DUTY PUMP

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

HORIZONTAL AGITATOR ASSEMBLY

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET CONVERSION FEATURES. Model Series INSTALLATION

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

Industrial. Solutions brands you trust. Product Overview

Full-line Product Overview

These pumps offer unique capabilities which are either not available or costly to acquire with other pumps.

SMF PUMP OWNER S MANUAL

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

User s Manual and Operating Instructions

Please read the following installation instructions first after purchasing this product or transporting it to another location.

Penguin. Series P. Vertical Pump

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

The sealless FLUX F 424

SERIES 'HE' PLASTIC HORIZONTAL PUMP MODEL: H2 x1½

Series PX. Installation & Maintenance. Models: PX-3 PX-5 PX-7 1/2-HF PX-10-HF PX-15-HF. Materials: A - CPVC

D14 & D18 Upright Vacuum

OWNER S MANUAL #DC2000Y #DC2000YCF 2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2000Y Global Rd.

Owner s Manual CMC100 Dehumidifier

Types TMUB, TMUAH and. J Jockey Pumps

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

SAFETY AND OPERATING MANUAL

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

CPVC Horizontal. Series HV. Centrifugal Pump. Flows to 132 GPM Pressure to 81 Ft. TDH. Model HV-1 1/2DV

Owner s Manual CMC100 Dehumidifier

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

PumpAgents.com - Click here for Pricing/Ordering PAR MAX3 Models Series 3.4GPM/12.8LPM

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

STAINLESS STEEL UNITS

Flexible Impeller Pumps in the Food Industry

Model K 3000 G Part No

INSTRUCTION AND REPAIR MANUAL

USER MANUAL UN-200V / UN-200VH

5-Gallon Pail Mixer OWNERS MANUAL M-2000 SERIES MIXERS. Contents: Page: Safety, General & Receiving... 2 Operation... 3 Parts List...

SECTION STEAM CONDENSATE PUMPS

QUICK PRIME INSTALLATION AND SERVICE MANUAL

Teflon Rotary Drum Pump

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

"S" SERIES IMMERSIBLE PUMP OWNER'S MANUAL INSTALLATION OPERATION PARTS Models S2 S4 S5 SS6 SS7 S8

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

1 L Rotary Vacuum Evaporator Instruction Manual

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Model HD 3501 Part No High Pressure Washer Operator Manual

LC Series - Light Commercial Pump Station Installation and Operation Manual

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

Air Driven Sewer Pipe Tapping Machine Instruction and Maintenance Manual

Model K 5800 G Part No

Transcription:

PumpAgents.com - Click here for Pricing/Ordering Model 6050-Series SELF-PRIMING PUMPS FEATURES Body: Impeller: Shaft: Wearplate: Shaft Seal: Ports: Motor: Weight: Bronze Construction JABSCO Nitrile 316 Stainless Steel Impeller Sleeve over Steel Motor Shaft Replaceable Lip Type 1" NPT, Internal 3/4 HP, Capacitor Type, Open Drip Proof or Totally Enclosed Fan Cooled, Overload Protector, 1725 RPM, 60 Hz, Single Phase, 115/230 Vac, with 8 foot cord and plug wired for 115 Vac operation. MOTOR IS NOT EXPLOSION PROOF! 35-1/2 lb (approx.) (16.1 kg) Model 6050-Series VARIATIONS AVAILABLE MODEL DESCRIPTION TYPICAL APPLICATIONS MARINE: Bait Tank Circulation; Washdown, Utility Dockside Pump, INDUSTRIAL: Industrial Filling Systems; Utility Shop Pump; Transfer Gum Arabic, Transfer Distilled Water; Recharge Water Softeners; Ice Water Recirculation; Hydro-static Pressure Testing; Sump Pumping. FOOD, BEVERAGE & DAIRY: Circulate Cooling Water; Defrost Refrigeration Coils; Fill Drums; Wash Down Equipment and Floors; Utility Pump. HOME: Fill and Empty Tubs, Pools; Empty Basements and Cesspools; Water Systems; Water Lawns and Gardens; Remove Water from Low Areas; Recharge Water Softeners. PLUMBING: Empty Clogged Drains; Empty Sumps, Smks and Tubs; Pump Out Water Closets. 6050-0003 Open Drip Proof Motor 6050-0013 Totally Enclosed Fan Cooled Motor HEAD CAPACITY TABLE TOTAL HEAD CAPACITY Feet Metres Litres PSI kg/cm2 of of GPM per Water Water Min. 4.3 0,3 10 3,0 23.0 87 8.7 0,6 20 6,1 22.0 83 17.3 1,2 40 12,2 19.5 74 26.0 1,8 60 18,3 15.5 59 Progressively longer life may be expected as operating pressures are reduced. Table shows approximate Head-Flow for new pump in U.S. gallons and litres with nitrile impeller. FARM: Fill Tractor Tires, Water Tanks; Pump out Silo Pits (liquid manure); Flush and Clean Animal Pens. CONTRACTORS: Remove Water from Excavations; Supply Water to Mortar Boxes; Cement Mixing; Washdown Equipment.! WARNING Explosion hazard. Do not use where flammable vapors are present. Do not pump solvents, thinners or gasoline. To do so can cause an explosion which can result in injury or death.

OPERATING INSTRUCTIONS 1. INSTALLATION - Pump maybe mounted in any position without loss of efficiency; however, it is suggested that the pump head be down if vertical mounting is desired. The rotation of the motor shaft determines the location of the pump intake and discharge ports. Intake is on right when looking at pump end cover. 2. DRIVE - DIRECT. 3. SELF-PRIMING - Pump will produce a suction lift approaching 10 feet when dry and a lift up to 22 feet when primed. BE SURE SUCTION LINES ARE AIRTIGHT or pump will not self-prime. SERVICE INSTRUCTIONS DISASSEMBLY 1. Remove end cover and end cover gasket. 2. Remove impeller. 3. Loosen cam screw and remove cam. Clean off sealant. 4. Remove wearplate with screwdriver or hooked wire. 5. Loosen nut at body clamp and remove body from motor. 6. Press out seal from motor mounting end of body towards impeller bore. 4. RUNNING DRY - Unit depends on liquid pumped for lubrication. DO NOT RUN DRY for more than 30 seconds. Lack of liquid will damage impeller. 5. NOTICE - Do not pump solvents, thinners, highly concentrated organic acids. Impeller and pump damage may occur. If corrosive fluids must be handled, consult Jabsco Chemical Resistance Chart ( which is available upon request from ITT Jabsco). Pump life will be prolonged if pump is flushed with water after each use or after each work day. 6. PRESSURES - For continuous operation, discharge pressure should not exceed 20 psi (1,4 kg/cm2). 7. TEMPERATURES - Nitrile impeller supplied in pump is recommended for liquid temperatures of 50 to 180 F (10 to 83 C). 8. FREEZING WEATHER - Drain unit by loosening the end cover. 9. To prevent run dry damage of the impeller, it is recommended that a Jabsco vacuum switch model 4732-0000 be installed. 10. GASKET - Use standard pump part. A thicker gasket will reduce priming ability. A thinner gasket will cause impeller to bind. Standard Gasket is 0.010 thick. 11. SPARE PARTS - A Jabsco Service Kit 90058-0003 should be kept on hand to service all but the most badly worn 6050 pumps. 7. Slide O-ring off shaft. NOTE: Inspect all parts for wear or damage and replace, if necessary. When returning pump to factory for repair, do not send motor unless it requires replacement. It is suggested that you contact local motor manufacturer's distributor for service. ASSEMBLY 1. Press seal into seal bore with lip facing toward the impeller bore. 2. Install wearplate, aligning slot with dowel pin in body. 3. Apply a thin coat of sealant to top of cam and cam screw threads. Install cam and secure with cam screw. 4. Lubricate impeller bore with water pump grease and install impeller in body. Use care not to damage seal lip with impeller sleeve. 5. Install gasket and end cover, securing with end cover screws. 6. Install 0-ring on motor shaft and position 1/4" from motor boss. 7. Apply a liberal coating of grease to the 0. D. of the motor shaft. 8. Align ding in impeller with shaft keyway and install on motor. 9. Secure nut at clamp. Do not overtighten.

EXPLODED VIEW PARTS LISTS Key Part Number Description Qty. Req. 1 91003-0010 Screws (End Cover) 6 2 11831-0000 End Cover 1 3* 890-0000 Gasket 1 4* 6056-0003 Impeller Nitrile 1 6056-0001 Impeller Neoprene (opt) 1 5 934-0000 Cam 1 6 4156-0010 Wearplate 1 7* 92700-0080 Seal 1 8 91004-0090 Screw (Cam) 1 9 6054-0000 Body 1 10 18736-0000 Motor (ODP) 1 18738-0000 Motor (TEFC) 1 11 91105-0030 Nut (pump to motor bolt) 1 12 91095-0090 Bolt (pump to motor) 1 13 6398-0000 O-Ring 1 14 92650-0070 Plug 1 90058-0001 Service Kit Neoprene 90058-0003 Service Kit Nitrile 6065-0003 Pump Head * Included in Service Kit

TO EQUIP WITH VACUUM SWITCH 1. Disconnect pump from power source. 2. Install vacuum switch (Jabsco model 4732-0000) in tapped hole on top of inlet port with nipple provided. (Seal threads prior to assembly.) 3. To connect switch to motor see Fig. 1. Remove cord from motor. Connect switch to motor terminals using length of cord supplied with switch. Connect cord to line terminals of switch, attach ground wire. 4. Plug into 110 Vac outlet and hold down restart lever on switch until the pump primes. SPECIAL ATTENTION 1. Constant vibration of the vacuum switch's restart lever indicates: (A) An air leak. This will usually show up when the pump is first started. All suction lines should be checked for loose connections. (B) A worn impeller. Impeller should be replaced. 2. Intermittent stopping and starting of pump indicates that the unit is operating against excessive discharge pressure. DIMENSIONAL DRAWING INCHES (millimetres) Fig. 1. Wiring Diagram for Vacuum Switch 8 ft cord and 3 prong plug wired for 115 Vac operation THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO THE JABSCO ONE YEAR LIMITED WARRANTY, WHICH IS AVAILABLE FOR YOUR INSPECTION UPON REQUEST.

For technical advice or service please take your pump into your local pump service center. To order pump or parts or for pricing please go to the following links : Jabsco Pumps Home >> Jabsco Pumps stock list >>