CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

Similar documents
Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

HCLEARFIRE. High-efficiency, modular steam boiler HP

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

CLEARFIRE HIGH-MASS CONDENSING FIRETUBE BOILER 500 TO 2,000 MBH

MODEL M5M. High-Efficiency Packaged Watertube Boiler MMBTU

FLX FLEXTUBE. The Widest Range of Hydronic and Steam Watertube Boiler Systems 1,500 to 25,000 MBTU/HR (35-600HP)

Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

ClearFire - Hydronic Startup Report

PROFIRE -E SERIES BURNERS

CFLC ClearFire Condensing Boiler. Boiler Book 05/2018

Originators of the Flexible Water Tube design

CAMUS. two-pass counter flow fire tube commercial boilers. for hydronic heating and hot water supply TURNDOWN RATIO! HYDRONICS LTD. Rev.

ULTRA HIGH EFFICIENCY CONDENSING BOILERS MILLION BTU/HR

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Automatic Circulating Water Heaters

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

CFC-E ClearFire Condensing Boiler. Boiler Book 09/2017

Originators of the Flexible Water Tube design

Originators of the Flexible Water Tube design

INDUSTRIAL WATERTUBE BOILERS

CONDENSING HIGH EFFICIENCY BOILERS

Suggested Specifications Prestige Excellence 110

The world s standard in efficiency. CBEX FIRETUBE

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Cleaver-Brooks Webinars

New Features RIELLO ARRAY. v2.0. High Efficiency Condensing Boiler MBH.

Triton Series High Efficiency Boiler

WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE BOILERS

WATER-TUBE POOL HEATERS

Boilers Variable Fire Boilers

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series

AM Rapid Recovery Water Heaters

TABLE OF CONTENTS BRADFORD WHITE BOILERS

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

DIVISION FINNED WATER-TUBE BOILERS

FXLF-9. High Efficiency Water Heaters and Boilers

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

FINNED WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

HIGH EFFICIENCY COMMERCIAL BOILERS

DIVISION FINNED WATER-TUBE WATER HEATERS

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

FINNED WATER-TUBE POOL HEATERS

CONDEXA PRO EXCELLENCE AND VERSATILITY

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Table Of Contents. Clearfire Condensing Boiler Model CFC

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER

Revitalize Building Mechanical Systems (4619)

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

TOTAL SYSTEM EFFICIENCY: CONTROL STRATEGIES & SYSTEM DISTRIBUTION. David Grassl PE Mechanical Engineer Principal

P-K MACH 'n' ROLL DOMESTIC HOT WATER AND COMFORT HEAT SYSTEM

ClearFire. Startup Guide. Model CFH. Horizontal Steam Boiler

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

Power Flame Incorporated

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

Benchmark. High-Efficiency Boilers. AERCO.com

Proudly assembled in U.S.A

Proudly assembled in U.S.A

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

Williams & Davis Boilers

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

Commercial Tankless Rack System

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Medium Mass Boilers. Maxim Power VT

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

Williams & Davis Boilers

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

CLEARFIRE MODEL CFW MBH Hot Water Vertical Boiler

Now Available with PVC & Polypropylene Vent Configurations

CONDENSING, MODULATING, HOT WATER SUPPLY, POOL, AND HYDRONIC HEATING BOILERS

Raypak Residential Products

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Gas-Fired Condensing Boilers A Green Start To Space & Water Heating

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

The WCGH High Efficiency Commercial Water Heater with Storage Tank

Commercial Boilers and Domestic Water Heaters APG-5

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

Benchmark. High-Efficiency Boilers

Proven Heritage RTS STANDARD EQUIPMENT. (413) FAX: (413) You can rely on Smith Cast Iron

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

Transcription:

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

Unmatched Efficiency and Low-NOx Technology in a Condensing Boiler The ClearFire -C is a completely integrated solution with firetube heat exchanger, premix burner and boiler management controls. The advanced heat exchange design in the ClearFire-C allows the boiler to achieve efficiencies up to 99%, and the modulating premix burner delivers high turndown and NOx levels to less than 20 ppm. This boiler is ideal for central heating applications and indirect hot water supply for working pressures up to 125 psig. 3 ClearFire C 500 3,300 MBTU/hr 2 4 1 CONDENSING HYDRONIC Features Metal fiber premix modulating burner for ultralow NOx emissions Patented ALUFER firetube heat exchanger Dual temperature returns provide 6+% efficiency gain 6 8 5 Optional dual gas train for critical backup fuel source Fresh air inlet connection for sealed combustion Thermal shock resistance Low hydraulic resistance (ideal for primary variable flow applications) Capable of handling low flow situations, meaning no flow switch is required High water volume content to reduce cycling, so no buffer tank required Designed for Maximum Efficiency 1 Falcon control for boiler modulation, safety and system integration 2 Premix modulating blower assembly 3 1:1 fuel-air ratio gas valve control 4 Metal fiber premix burner for ultra-low emissions 5 Patented ALUFER firetubes for maximum condensing efficiency 6 Dual temperature return connections for 6+% efficiency gain 7 Flue condensation collection reservoir No minimum temperature requirement Easy-access, hinged burner boiler lid to aid burner servicing Low NOx SCAQMD pre-certified culus listed for natural and propane gas Manufactured to ASME section IV Low noise with less than 70 dba at 3 feet 2

Intelligent Integrated Controls Boilers The Cleaver-Brooks Falcon is a proven boiler/burner management control that provides an intuitive operator interface featuring integrated burner sequencing, trending, flame safety, modulation, alarms, lockout, and much more, ensuring your boiler system operates at peak efficiency, while providing necessary safety and reliability. The Cleaver-Brooks Falcon control with integrated lead/lag optimizes the boiler room s operational efficiency while delivering precise temperature control to meet heating demands. The Cleaver-Brooks Falcon can communicate with your building s Energy Management System (EMS), which helps maximize overall system efficiency. User-friendly Controls Touch-screen graphics with trending Multiple loop PID set point control (central heat, domestic hot water and lead/lag) Configurable lead/lag control to match system requirements Pump, valve, damper enable/disable Outdoor temperature reset Post shutdown pump delay Remote enable and set point ModBus (RS485) Communications Optimal Hydronic Boiler Room Management The ClearFire -C condensing boiler operates most efficiently at reduced firing rates. The Falcon lead/lag control is uniquely capable of taking advantage of the CFC s combustion and thermal performance characteristics to sequence and modulate CFC boilers to maximize system efficiency. Energy Management System The Falcon lead/lag control uses the common base load firing rate method to sequence and modulate a multiple-boiler system. This approach optimizes the boilers operating efficiency while minimizing energy-wasting short cycling. The elimination of short cycling minimizes purge and standby losses, while extending the life and reliability of your boiler system. 101% 99% 97% 95% 93% 91% 89% 87% Percent Efficiency Single Return Efficiency as a Function of Temperature 85% Return Water Temperature 60 80 100 120 140 160 Firing Rate Percentage 20 50 75 100 3

The Latest Boiler Design Technology The ClearFire -C, featuring ALUFER technology, is the best condensing boiler on the market. Designed from the ground up to provide maximum condensing efficiency, the most reliable operation and complete system design flexibility. The dual return advantage provides a 6%+ efficiency gain. The ClearFire-C was designed with the boiler operator in mind; from the hinged burner to the built-in service platform, no other boiler is as easy to maintain. ALUFER FIRETUBE TECHNOLOGY HEAT EXCHANGER Every aspect of the true counterflow design is engineered to ensure the maximum effective heat transfer possible. Our proven firetube arrangement ensures reliability and longevity. The large water volume and low pressure drop inherent in our firetube design make it ideal for variable flow primary pumping applications. MODULATING PREMIX BURNER Our heat exchanger features the ALUFER firetube technology and is constructed from an inner (fireside) aluminum alloy finned surface, diefitted within an outer duplex stainless steel tube, providing exceptional heat exchange characteristics. The corrosion-resistant properties of the ALUFER firetube assure long life and reliability of the boiler. 4Thermal conductivity is 10 times greater than stainless alone 4Fireside is divided into 10 flow channels for maximum heat transfer and condensing performance The modulating premix burner and linkageless control automatically adjust the air/ gas mixture for maximum efficiency and optimum turndown. A symmetrical, 360 even-temperature heat output is achieved from the burner, providing clean combustion with ultra-low NOx emissions of less than 20 ppm as standard and less than 9 ppm as optional. WARRANTY In addition to the standard warranty, the pressure vessel is warranted (nonprorated) for 20 years against thermal shock and 10 years against fireside condensation corrosion. The burner canister is warranted for five years. 4Provides the maximum effective heating surface where it is needed the most 4Heating surface up to five times larger than other condensing boilers 4

Dual Return Advantage Boilers The ClearFire -C and ClearFire -LC s Dual Return Advantage offers more opportunity to improve system efficiency. Most hydronic systems blend returns from different loops, compromising the performance of your condensing boiler system. The combination of our counterflow heat exchanger and ALUFER firetubes is what allows you to connect a cold (less than 130F) return to the lower inlet connection and connect a high-temperature (greater than 140F) return to the upper inlet connection, realizing a 6+% gain in efficiency by achieving true condensing performance even in applications with high-pressure heating loops. Load 1 Load 2 10-30% of Total Load 180 F 120 F 180 F 150 F 80 F 150 F 80 F Make-Up Water Domestic Hot Water Dual Return High Efficiency as a Function of Low-Temperature Return Flow Percentage 98.0% 96.0% Blended 140 F 94.0% 92.0% 90.0% 88.0% Percent Efficiency $ 25% (low) 80 F 75% (high) 160 F 86.0% Percent Firing Rate 20% 40% 60% 80% 100% 5

ClearFire -C Boiler Dimensions and Ratings Plan view I Rear view Side view 6

Boilers ITEM DIMENSIONS BOILER MODEL 500 750 1000 1500 1800 2500 3300 maximum input (BTU/hr) 500,000 750,000 1,000,000 1,500,000 1,800,000 2,500,000 3,300,000 A overall height 71.9" 71.9" 75.4" 81.5" 81.5" 81.9" 85" B overall width 32.3" 32.3" 36.6" 43.7" 43.7" 50.8" 61.3" C overall depth 48.9" 48.9" 64.0" 65.6" 65.6" 72.3" 86.3" D width less casing 26.8" 26.8" 31.1" 38.2" 38.2" 45.3" 55.5" E gas connection to top of casing 7.8" 7.8" 9.2" 9.5" 9.5" 9.4" 10" F gas connection to floor 64.1" 64.1" 66.2" 72" 72" 72.5" 75" G side of casing to gas connection 2.5" 2.5" 3.8" 4.9" 4.3" 5.2" 5.1" H boiler centerline to air inlet 4.3" 4.3" 3.9" 7.0" 7.0" 7.0" 7.1" I floor to bottom of base 10.3 10.3 10.3 10.3 10.3 10.3 10.3 J floor to top of stack connection 18.6" 18.6" 18.1" 19.1" 19.1" 20.9" 21.4" K centerline to centerline of stack stub 15.4" 15.4" 16.9" 21.0" 21.0" 28.1" 35.8" L rear of boiler to centerline of stack stub 5.4" 5.4" 7.5" 8.1" 8.1" 8.6" 10.0" M front of boiler to rear of casing 38.8" 38.8" 49.6" 49.4" 49.4" 56.5" 67" N control panel projection 4.1" 4.1" 4.1" 4.1" 4.1" 4.1" 4.3" O casing height 56.2" 56.2" 60" 65.4" 65.4" 65.4" 67" P air vent line projection 7.8" 7.8" 7.3" 8.1" 8.1" 8.7" 4.7" Q floor to centerline of lower return connection 19.7" 19.7" 20" 21.1" 22" 23" 24.1" R floor to centerline of upper return connection 28.5 28.5 29 31 33 34.5 35.5 S floor to centerline of supply connection 54.4" 54.4" 56.6" 57.5" 56.9" 56.8" 59.1" T floor to centerline of air vent 59.9" 59.9" 62" 62.9" 62.9" 64.8" 66.4" AA boiler adjustment foot height 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" 2.5" AB height above boiler for burner service 14" 14" 14" 14" 14" 14" 18" CONNECTIONS U water supply, 150 rf flg 2 1/2" 2 1/2" 2 1/2" 3" 4" 5" 5" V boiler air vent, npt 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" W electrical conduit, left or right 1.6" 1.6" 1.6" 1.6" 1.6" 1.6" 1.6" X boiler drain, npt 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" 1 1/2" Y flue gas nominal od, left or right option 6" 6" 8" 10" 12" 12" 12" Z combustion air option 4" or 6" 4" or 6" 4" or 6" 6" or 8" 6" or 8" 8" 8" BB gas connection, npt 1" 1" 1" 1 1/2" 1 1/2" 1 1/2" 2" CC condensate drain, npt 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1" DD water return (upper) rf flange 2 1/2" 2 1/2" 2 1/2" 3" 4" 5" 5" EE water return (lower) rf flange 2 1/2" 2 1/2" 2 1/2" 3" 4" 5" 5" relief valve outlet (125# setting) 1" 1" 1" 1" 1" 1" 1" voltage fan motor 115/1 115/1 115/1 115/1 115/1 115/1 208-240/3 voltage control circuit 115/1 115/1 115/1 115/1 115/1 115/1 115/1 RATINGS btu/hr output @ sea level to 2000' nat gas* 480,000 697,000 940,000 1,410,000 1,690,000 2,412,500 3,184,500 shipping weight, lbs. 1,160 1,160 1,795 2,225 2,505 3,640 4,835 operating weight, lbs. 1,585 1,585 2,545 3,165 3,325 4,685 6,570 inlet gas pressure, lo fire/hi fire "w.c. 6.8/5.0 6.8/5.0 6.8/5.0 10.0/7.0 7.0/5.0 9.5/8.0 6.8 max. amp draw fan @ 115V/1PH 4.0 4.0 4.0 8.5 12.0 12.0 6.9** amp draw control circuit 1.3 1.3 1.5 1.5 2.0 2.0 2.3 fireside heating surface 185 185 307 445 596 937 1,258 Notes: * Output based on return water temperature at 80 F ** AMP draw @ 208V/3PH 7

Total Integration goes far beyond boilers. For more than 80 years, Cleaver-Brooks has built a reputation for innovation in the boiler solutions industry. We remain committed to introducing technology and products that enable a more energy-efficient and environmentally friendly generation of steam and hot water. When you come to us for a condensing boiler solution, you can know that each element is created to the highest standards and all will work together seamlessly to give you a highly efficient and reliable solution for protecting your boiler system. To learn more, please call or visit us online. Boiler system icons are copyrights of Cleaver-Brooks, Inc. Packaged Boiler Systems 221 Law Street Thomasville, GA 31792 USA 800-250-5883 info@cleaverbrooks.com cleaverbrooks.com Printed in the USA 2014 Cleaver-Brooks, Inc CB-7957 01/14