TEST REPORT. Junction Box (Dimension 123x78mm) MakelModel No. Raychem /- Serial No. l?qdcg/1641 Quantity/ No. of samples

Similar documents
TEST REPORT Report No.: HN80013/2011 Page: 1 of 7 Date: August 30, 2011

TEST REPORT Reliability Laboratory Report No.: HCD0203/2008

TEST REPORT IEC60529 Edition TD990426C02

EN 60529:1991+A1:2000+A2:2013 Measurement and Test Report

TEMPORARY IMMERSION AND DUST TEST REPORT

TEMPORARY IMMERSION AND DUST TEST REPORT

PURPOSE. 03/08/18 REVISOR SGS/HR RD The purpose ofparts to is to protect public health by establishing

Contact person Date Reference Page Henrik Andersson F (4) Electronics

Certificate of Approval

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

SECTION Fluorescent Dissolved Oxygen Measuring System

EU-Type Examination Certificate

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

PQS Independent type-testing protocol

ENVIRONMENTAL TEST REPORT

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

DUST TEST REPORT. :Gold Apollo Co., Ltd. Company Model Name :A27. Date of Received :APR. 19, 2006 Date of Tested :APR. 19, 2006

Lawnmowers (pedestrian controlled, battery powered)

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Environment Test Report

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

Conventional Feeder Pillar Box

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986

Animals:Goats:Bleat.Calls,Warbling.Baa,Movements.Rubbing,Barn,Medium.Close,Interior,BG.Dog.Barks 01:21.618

C e r t i f i c a t e

Shipboard incinerators with capacities up to 4000 kw

Survey of electrical equipment installed in hazardous areas on tankers

CERTIFICATE of QUALITY TEST

CERTIFICATION OF EXPLOSIVES UNDER G.B. STATUTORY INSTRUMENT No. 2714

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Issued to: Videl S.r.l. Località Ponti di Pievescola Casole d Elsa (SI)

NATIONAL TECHNICAL SYSTEMS

Report No.: SQE Page 2 of 11 Issued: Test Report No. : EMC -- T E S T R E P O R T SQE Equipment under Test : 24Bit Barometer

CERTIFICATION OF EXPLOSIVES UNDER G.B. STATUTORY INSTRUMENT No. 2714

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

PQS Independent type-testing protocol

Sound Pressure Level Test Report Report No. : PH2_09_ Date : 2009/6/30

Not to be reproduced without the permission of Last date for receipt of BIS or used as a STANDARD comments is: 15 July 2012

On Electromagnetic Compatibility

Eligibility Criteria for Participation [Qualification Requirement (QR)]

NF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS

ON THE BUTTON A reference guide to environmental ratings used for push button enclosures

SIMPLIFIED VOYAGE DATA RECORDER (S-VDR)

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

SECTION Free/Available Chlorine Analysis System

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

CERTIFICATION OF EXPLOSIVES UNDER G.B. STATUTORY INSTRUMENT 2016 No 315

ENGROSSED SUBSTITUTE HOUSE BILL State of Washington 60th Legislature 2007 Regular Session

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

INTERNATIONAL STANDARD

GASTEC QA. Approval Requirements 31-2

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

WIO200 Water in oil sensor

Manual Power relay SR853

GASTEC QA. Approval Requirements 31-1

Test Report to AS/NZS :2015. Report No. T160402_S

IQ/OQ Protocol Installation Qualification/ Operation Qualification SteamScrubber & FlaskScrubber Laboratory Glassware Washers

Test Report. Appliance EMF Testing

Quality Assurance Plan for Conducting Radon Measurements

TEST REPORT IEC Safety of laser products - Part 1: Equipment classification and requirements

GASTEC QA. Evaluation Guideline KE 191. Amendment A1 Excess flow valves. KE A1 March 2012

2. Safety instructions

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch

CNBOP-PIB Standard Fire Protection

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

This is a preview - click here to buy the full publication INTERNATIONAL ELECTROTECHNICAL COMMISSION

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ALPHA TRACK. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

MEASUREMENT AND TEST REPORT

SOUND RECEPTION SYSTEM

Model : LPSA-40A Please read this manual carefully before using the instrument Labnics Equipment

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

incubator, the best in its class

Specification for testing to be conducted at periodic surveillance of products and systems

Cavitator Ultrasonic Cleaner Instruction Manual

Size and rating wise typical Third Party Inspection certificates for the models of Valves

E/ECE/324/Rev.1/Add.27/Amend.5 E/ECE/TRANS/505/Rev.1/Add.27/Amend.5

LAB ID and/or LABORATORY NAME: ASSESSOR NAME: ELECTRET by Voltametry. Method Number: ELAP method number SOP Number: Revision Number: SOP Date:

EC TYPE EXAMINATION (Module B) CERTIFICATE MARINE EQUIPMENT DIRECTIVE Certificate No.: 0832-MED-1019

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

REVISION HISTORY Rev Description Author. Approved by Date A Initial release per ECO Dean King Dean King November 16, 2012

Technical-Report for SL Lamp 5 W

EC TYPE EXAMINATION (Module B) CERTIFICATE MARINE EQUIPMENT DIRECTIVE Certificate No.: 0832-MED-1011

Supplementary Installation and Operating Instructions. Category II2G

XB-EFA-8L-BK & XB-EFA-8R-BK

MO n : 12JMC rév A

Certificate of Compliance

EC TYPE EXAMINATION (MODULE B) CERTIFICATE

Acceptance Requirements. Fibre Optic Systems. Revised 12/2017. December 5th, Alexander Kölbel

Installation and Operations Manual

Refrigerated Incubator Model and Operating Instructions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Certificate of Compliance

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

Additional deviations may possibly be found if a complete type test is carried out on the product.

IQ/OQ Protocol Installation Qualification/ Operation Qualification

Transcription:

B 177/178, GIDC Electronics Estate, Sec-25, Gandhinagar-382024 (Under STQC Programme, DIT, Ministry ofcomm. & Infonnation Technology, Govt. ofindia) REPORT NO.: EQP/G0204/0304/2012 Page 1 00 TEST REPORT Service Request Form No. SRFDate: Date of Issue: G0204/2012 16/03/2012 30/03/2012 Name & Address ofthe Customer Mis. Raychem RPG Limited, Ceta Mahal Annexe, 463, Dr.Annie Besant Road, Worli, Mumbai. DESCRIPTION/ IDENTIFICATION OF THE ITEM Nomenclature Junction Box (Dimension 123x78mm) MakelModel No. Raychem /- Serial No. l?qdcg/1641 Quantity/ No. of samples 01 Date ofreceipt ofitem 16/03/2012. Date ofcompletion oftest 19/03/2012 Condition ofequipmentlmaterial on receipt. Good Location where test is performed LAB, EQDC- Gandhinagar Test Specification With reference to IS/IEC 60529: 2001 Clause No. 13.4, 13.6.2, 14.2.7, 14.3 Test facilities used: Nomenclature Make/Model Serial Number Calibration Due Date 1J Dust Chamber C.K. Enterprise/- EQDCG/0203 01/12/2012 2] Water Tank EQDC/- EQDCG/WT-01 - Prepared by:.~j---- Form No.: T/2/GEN.,Issue No: 03, Rev-OS, Dated. 03.11.10

.'''.'''~ - -, ELECTRONICS AND QUALITY DEVELOPMENT CENTRE B 177/178, GillC Electronics Estate, Sec-25, Gandhinagar-382024 (Under STQC Progranune, DlT, Ministry ofcomm. & lnfonnation Technology, Govt. oflndia) REPORT NO.: EQP/G0204/0304/2012 Page 2 of3 TEST RESULT Sr. Test No. Parameters 1 IP6X: (Dust-tight Test) Test Method /Requirement Observations Remarks Ensure the degree of protection provided by the enclosure against penetration of dust by using following test. The EDT is supported in its normal operating position inside the test chamber in which talcum powder is maintained in suspension. The duration ofthe test is eight hours. The protection is satisfactory if no deposit of dust is observable inside the enclosure at the end of the test. After the test no dust found inside the EDT. 2 IPX8: (Temporary Immersion in water Test) Ensure the Degree of Protection provided by the enclosure against water by using following test: Method The EDT is completely immersed in the water. The surface ofthe wilier shall be at least 150 mm above the highest poin(ofthe item. The lowest portion of the item shall be at least 1 meter below the surface ofthe water. The duration ofthe test is Ihr. The water temperature shall not differ from that of the item by more than 5 C. After completion of test the item shall be removed from the water and visually examined for the ingress of water inside the item. Requirement Ingress ofwater shall not be sufficient to interfere the satisfactory operation ofthe equipment. No water found inside. the EDT. I Prepared by: &~ Form No.: T/2/GEN.,Issue No: 03, Rev-OS, Dated 03.11.10

B 177/178, GIDC Electronics Estate, Sec-25, Gandhinagar-382024 (Under STQC Programme, DlT, Ministry ofcomrn. & Infonnation Technology, Govt. ofindia) REPORT NO.: EQPJG0204J0304J2012 Page 3 of3 Remarks: 1) EUT: - Equipment under Test. 2) Holograms having Sr. No. 013570 to 013572 affixed on each page oftest report. NOTE: 1. This report refers only to particular item(s)l equipment(s) submitted for testing. 2. This report shall not be reproduced except in full without the written approval from Director, EQDC (Gandhinagar). 3. The test results reported are valid at the time of and under the stated condition of measurement. 4. Only the test asked for by the party have been carried out. 5. Any anomalies/ discrepancies in this report should be brought to 0 from the date of issue of this re ort. Prepared by: ~ Officer In-CHarge Customer Service Celt

B 177/178, GillC Electronics Estate, Sec-25, Gandhinagar-382024 (Under STQC Progranune, DIT, Ministry ofcomm. & Infonnation Technology, Govt. ofindia) REPORT NO.: EQP/G0214/0314/2012 Page 1 of3 TEST REPORT Service Request Form No. SRFDate: Date ofissue : G0214/2012 20103/2012 30103/2012 Name & Address ofthe Customer Mis. Raychem RPG Limited, Ceta Mahal Annexe, 463, Dr.Annie Besant Road, Worli, Mumbai. DESCRIPTIONI IDENTIFICATION OF THE ITEM Nomenclature Junction Box (Dimension 123x78mm) MakelModel No. Raychem 1--. Serial No. EQDCGI1642 Quantity/ No. of samples 01 Date ofreceipt ofitem 2010312012 Date ofcompletion oftest ~ 23/03/2012 Condition ofequipmentlmaterial on receipt Good. Location where test is performed LAB, EQDC- Gandhinagar Test Specification With reference to IS/IEC 60529: 2001 Clause No. 13.4, 13.6.2, 14.2.7, 14.3 Test facilities used: Nomenclature MakelModel Serial Number Calibration Due Date 1] Dust Chamber C.K. Enterprise/- EQDCG/0203 01112/2012 2] Water Tank EQDCI- EQDCGIWT-01 -- Prepared by: ~J--- Form No.: T/2/GEN.,Issue No: 03, Rev-OS, Dated 03.11.10

B 177/178, GIDC Electronics Estate, Sec-25, Gandhinagar-382024 (Under STQC Programme, DIT, Ministry ofcomrn. & Infonnation Technology, Govt. ofindia) REPORT NO.: EQP/G0214/0314/2012 Page 2 of3 Sr. No. Test Parameters IP6X: (Dust-tight Test) (Dimension 123x78mm) 2 IP X8: (Temporary Immersion in water Test) (Dimension 123x78mm) TEST RESULT Test Method /Requirement Observations Remarks Ensure the degree of protection provided by the enclosure against penetration of dust by using following test. The EUT is supported in its nonnal operating position inside the test chamber in which talcum powder is maintained in suspension. The duration of the test is eight hours. The protection is satisfactory if no deposit of dust is observable inside the enclosure at the end of the test. Ensure the Degree of Protection provided by the enclosure against water by using following test: ~ Method water. The EUT is completely immersed in the The surface of the water shall be at least 150 mm above the highest point of the item. The lowest portion of the item shall be at least 1 meter below the surface of the water. The duration of the test is Ihr. The water temperature shall not differ from that ofthe item by more than 5 C.. After completion of test the item shall be r~moved from the water and visually examined for the ingress of water inside the item. Reguirement Ingress of water shall not be sufficient to interfere the satisfactory operation of the equipment. After the test no dust found inside the EUT. No water found inside the EUT. Prepared by: ~ Form No.: T/2/GEN.,Issue No: 03, Rev-OS, Dated 03.11.10

~\\ yd ~~. g' ELECTRONICS AND QUALITY DEVELOPMENT CENTRE B 177/178, GlDC Electronics Estate, Sec-25, Gandhinagar-382024 (Under STQC Programme, DlT, Ministry ofcornm. & Information Technology, Govt. ofindia) REPORT NO.: EQP/G0214/0314/2012 Instrument Photographs E(!)<~C.... c,i Page 3 of3 " Remarks: 1) EUT: - Equipment under Test. 2)Holograms having Sr. No. 013567 to 013569 affixed on each page of test report. PrepMedby: ~ NOTE: I. This report refers only to particular item(s)/'equipment(s) submitted for testing. 2. This report shall not be reproduced except in full without the written approval from Director, EQDC (Gandhinagar). 3. The test results reported are valid at the time ofand under the stated condition ofin: urement. 4. Only the test asked for by the party have been carried out. 5. Any anomalies! discrepancies in this report should be brought to our no. date ofissue ofthis re ort. Issued by : Name : N' ii S jl a Desi nation: n Char e C