LIGHT LEVEL REQUIREMENTS MINIMUM ACCEPTABLE FOOT CANDLES

Similar documents
Kitchen south wall, living room north and south wall outlets 3. not working properly; no GFCI.

TABLE LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS ASHRAE Uncovered Parking Areas. Building Grounds. Walkways 10 feet wide or greater

Ho-Chunk Gaming THUNDERBIRD ENGINEERING, INC. MILWAUKEE: (414) MADISON: (608)

Electrical System (N) PANELBOARD "L1" VOLTAGE: 208/120 A, 3P :MAIN C/B PHASE: 3 A :BUSSING WIRE: 4 :MOUNTING

ELECTRICAL SYMBOLS AND ABBREVIATIONS NOT ALL SYMBOLS, DEVICES OR ABBREVIATIONS MAY BE USED

NYC Department of Education

NYC Department of Education

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

F. GENERAL REQUIREMENTS Electrical Design Criteria 2006 Edition 4/3/06 School District Palm Beach County Page-1 of 15

NYC Department of Education

Lindsay Frederick. Lighting + Electrical. Ron Dodson Faculty Advisor. Native American Cultural Center Arizona. Technical Report 2

NYC Department of Education

NYC Department of Education

F. GENERAL REQUIREMENTS Electrical Design Criteria 2009 Edition 11/23/2009 School District Palm Beach County Page-1 of 17

2009 ELECTRICAL CODE REQUIREMENTS

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

White Bear Lake Area Schools District 624 ENERGY GUIDELINES

NYC Department of Education

NYC Department of Education

NYC Department of Education

PLATTEVILLE MIDDLE SCHOOL


NYC Department of Education

Calmeca Academy of Fine Arts and Dual Language

Josefa Ortiz De Dominguez Elementary School

Building Electrical System Overview

Heat Recovery Units. EXTERNAL STATIC REQUIRED (in.h2o) (Pa) MOTOR (Bhp/Hp) (bkw/kw) SPEED (rpm)

ELECTRIC SERVICE EVALUATIONS ELECTRICAL / BOILER REPLACEMENTS. Clarkstown Central School District. June Arch Proj. #

NYC Department of Education

NYC Department of Education

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

Technical II Report Electrical Systems

NYC Department of Education

State College Area School District High School South Building EXISTING CONDITIONS ASSESSMENT

HEALTH/LIFE SAFETY ANNUAL INSPECTION CHECKLIST (ROE)

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

NYC Department of Education

Florence High School / Middle School Page 1 of 3 Florence, WI

NYC Department of Education

Appendix B. Facilities Assessment Report

FORT ERIE SECONDARY SCHOOL FACILITY INFORMATION. Lake Erie Corridor Secondary Schools Accommodation Review

Exhibit A. Mechnical, Plumbing, and Electrical Plan Check and Inspection Fees. Total Cost Per Unit FEE TYPES MECHANICAL PERMIT FEES


NYC Department of Education

NYC Department of Education

ll. Consistency Questions

Charles W Earle Elementary School

GRILLE, REGISTER AND DIFFUSER SCHEDULE

3. 21st Century Learning A. Districtwide Flexible Learning - Allowance for Flexible Furniture $600,000 Subtotal $600,000

Cook - Wissahickon Elementary School

2014 Bond Project Guide

SCHEDULE OF FEES. Penalty Fees. Building Fee Schedule FEE

Executive Summary. CNBC Global Headquarters Christine Cajilig

The following narrative outlines a conceptual electrical Scope of Work for converting the Phase 2 TRW Building to an Exhibition Hall.

NYC Department of Education

Division 26 ELECTRICAL TABLE OF CONTENTS

Oscar DePriest Elementary School

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

Element D Services Electrical

Edward Jenner Elementary Academy of the Arts

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

Richard Henry Lee Elementary School

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003

3520 A Energy Conservation Standards

AN ORDINANCE TO AMEND CHAPTER 7-BUILDING REGULATIONS, ARTICLE 1-UNIFORM CONSTRUCTION CODE, SECTION 7-2 -FEES TO ESTABLISH A NEW FEE SCHEDULE

Sidney Sawyer Elementary School

NYC Department of Education

NORTH CENTRAL MICHIGAN COLLEGE PETOSKEY CAMPUS. Facilities Conditions Assessment Mechanical And Electrical Petoskey, Michigan

NYC Department of Education

Agustin Lara Elementary Academy

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

ALLEGHANY COUNTY PUBLIC SCHOOLS Maintenance Work Request Completion Analysis

John Palmer Elementary School

Michigan State University DESIGN GUIDELINES. ELECTRICAL DESIGN Page 1 TABLE OF CONTENTS 1

ENGINEERING REPORT - MECHANICAL / ELECTRICAL / PLUMBING

Alessandro Volta Elementary School

MUKWONAGO AREA SCHOOL DISTRICT CAPITAL IMPROVEMENT / MAINTENANCE STUDY

Chandler City Hall Chandler, Arizona

Genevieve Melody Elementary School

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

2015 Building Condition Survey Summary Mosaic Associates Architects 02/19/16

FIRE ALARM: BY OTHERS, IF REQUIRED.

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

Ichabod Crane Central School District 2018 Capital Project Preliminary Estimate

AGENDA. 1. Call to Order. 2. Approval of Minutes. 3. Approval of Invoices and Commitments. 4. Review Updated Site Analysis and Permitting

HOLUM EDUCATION CENTER. Architectural. January 13, 2014 DeForest Area School District

FIRE ALARM: BY OTHERS, IF REQUIRED.

Schedule of Approved Fees

NYC Department of Education

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Building Automation System (BAS) Design Criteria

NAZARETH AREA SCHOOL DISTRICT MAINTENANCE DEPARTMENT 357 Tatamy Road, Nazareth, PA FAX

Rocky Mountain Chapter IAEI Annual Meeting Northglenn, CO March 18-19, 2004

SECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...

Library stacks and records storage 150 LB/SF live load

Technical Assignment #2 Electrical Systems Existing Conditions & Building Load Summary

Transcription:

LIGHT LEVEL REQUIREMENTS LOCATION Classrooms and instrumental areas- Study Halls, Lecture Rooms, Art Rooms, Offices, Libraries, Conference Rooms, Work Rooms, Shops, Laboratories and Secondary School Cafeterias. MINIMUM ACCEPTABLE FOOT CANDLES 50 Drafting, Typing and Sewing Rooms. 70 Reception Rooms, Gymnasiums, Auditoriums, Primary School Cafeterias, All-Purpose Rooms and Swimming 30 Pools. Locker Rooms, Washrooms, Toilet Rooms, Corridors containing lockers and Stairways. 10 Corridors without lockers and Storage Rooms. 5 Classrooms for the partially sighted. 70

MDP-GYM SERVICE LOAD CALC Peak Load 129.6 kw Removed Load 0 kw 129.6 kw *1.25 162 kw 93%PF 174.19 kva New Load 184.06 kva Combined Load 358.25 kva Calculations Based on NEC 220.87 PANEL SDP SERVICE LOAD CALCULATIONS CONNECTED LOAD: 'VA/SQFT = 107717VA/4221 SF 25.5 % VA/SQFT SQFT VA First 3VA/SQFT at 100% 1 3 4,221 12,663.00 3-20 VA/SQFT at 75% 0.75 17.00 4,221 53,817.75 Remaining VA/SQFT at 25% 0.25 5.52 4,221 5,824.31 Total kva 72.31 Total Amps 200.94 PANEL PP4 LOAD CALCULATIONS CONNECTED LOAD: 'VA/SQFT = 209369 VA/12044 SF 17.38 % VA/SQFT SQFT VA First 3VA/SQFT at 100% 1 3 12,044 36,132.00 3-20 VA/SQFT at 75% 0.75 14.38 12,044 129,928.12 Remaining VA/SQFT at 25% 0.25 0.00 12,044 0.00 Total kva 166.06 Total Amps 461.48 Calculations Based on NEC 220.86 MECHANICAL EQUIPMENT - ELECTRICAL DATA SCHEDULE EQUIPMENT NAME V-Ф-Hz HP/WATTS/A WIRE AND CONDUIT CIRCUIT BREAKER PANEL;CKT #(S) STARTER/ DISCONNECT BY MC/PC INSTALLED BY EC STARTER/ DISCONNECT BY EC THERMAL MOTOR SWITCH BY EC SUPPLY SMOKE DETECTOR QUANTITY RETURN SMOKE DETECTOR QUANTITY AC-2 120-1-60 0.45 FLA 3/4"C-3#12+1#12GND - - UNIT MOUNTED WIRED TO CU-1. PROVIDE WALL MOUNTED NEMA 5-20R RECEPTACLE FOR ASSOCIATED CONDENSATE PUMP. WIRE TO PP4;71 CU-2 120-1-60 7.6 FLA 3/4"C-2#12+1#12GND 20/1 PP5;1 UNIT MOUNTED AHU-1 120-1-60 0.346 FLA 3/4"C-3#12+1#12GND - - UNIT MOUNTED - - - - WIRED TO HP-1. SEE DETAIL 4. AHU-2 120-1-60 0.346 FLA 3/4"C-3#12+1#12GND - - UNIT MOUNTED - - - - WIRED TO HP-2. SEE DETAIL 4. PROVIDED WITH CONDENSATE PUMP, WIRE TO PP4;71 AHU-3 120-1-60 0.346 FLA 3/4"C-3#12+1#12GND - - UNIT MOUNTED - - - - WIRED TO HP-3. SEE DETAIL 4. PROVIDED WITH CONDENSATE PUMP, WIRE TO SDP;62 AHU-4 120-1-60 0.346 FLA 3/4"C-3#12+1#12GND - - UNIT MOUNTED - - - - WIRED TO HP-4. SEE DETAIL 4. PROVIDED WITH CONDENSATE PUMP, WIRE TO SDP;62 AHU-5 208-1-60 0.9 FLA 3/4"C-3#12+1#12GND - - UNIT MOUNTED WIRED TO HP-5. PROVIDED WITH CONDENSATE PUMP, WIRE TO SDP;62 HP-1 120-1-60 14.6 FLA 3/4"C-2#12+1#12GND 20/1 PP4;43 UNIT MOUNTED - - - - PROVIDE AND INSTALL WP GFI RECEPTACLE AND LIGHT, UNIT MOUNTED, WIRE TO PANEL "PP4" CKT 30. REFER TO DETAIL 3 HP-2 120-1-60 14.6 FLA 3/4"C-2#12+1#12GND 20/1 PP4;45 UNIT MOUNTED - - - - - HP-3 120-1-60 14.6 FLA 3/4"C-2#12+1#12GND 20/1 SDP;44 UNIT MOUNTED - - - - - HP-4 120-1-60 14.6 FLA 3/4"C-2#12+1#12GND 20/1 SDP;46 UNIT MOUNTED - - - - - HP-5 208-1-60 17.3 FLA 3/4"C-2#8+1#8GND 35/2 SDP;68,70 UNIT MOUNTED - - - - - CU-1 208-3-60 18 MCA 3/4"C-3#10+1#10GND 30/3 SDP;74,76,78 UNIT MOUNTED - - - - - CHU-1 120-1-60 2.75 MCA 3/4"C-2#12+1#12GND 20/1 SDP;71 UNIT MOUNTED - - - - - CHU-2 120-1-60 2.75 MCA 3/4"C-2#12+1#12GND 20/1 PP4;46 UNIT MOUNTED - - - - - CHU-3 120-1-60 2.75 MCA 3/4"C-2#12+1#12GND 20/1 PP4;44 UNIT MOUNTED - - - - - CHU-4 120-1-60 2.75 MCA 3/4"C-2#12+1#12GND 20/1 PP4;44 UNIT MOUNTED - - - - - CHU-5 120-1-60 2.75 MCA 3/4"C-2#12+1#12GND 20/1 PP4;46 UNIT MOUNTED - - - - - CHU-6 120-1-60 2.75 MCA 3/4"C-2#12+1#12GND 20/1 PP4;46 UNIT MOUNTED - - - - - CHU-7 120-1-60 2.75 MCA 3/4"C-2#12+1#12GND 20/1 PP4;46 UNIT MOUNTED - - - - - CHU-8 120-1-60 2.75 MCA 3/4"C-2#12+1#12GND 20/1 PP4;44 UNIT MOUNTED - - - - - EF-1 120-1-60 3/4 HP 3/4"C-2#10+1#12GND 25/1 PP4;48 - - UNIT MOUNTED - - - EF-2 120-1-60 3/4 HP 3/4"C-2#10+1#12GND 25/1 SPD;58 - - UNIT MOUNTED - - - EF-3 120-1-60 3/4 HP 3/4"C-2#10+1#12GND 25/1 SPD;60 - - UNIT MOUNTED - - - EF-4 208-1-60 1/3 HP 3/4"C-2#12+1#12GND 20/2 SDP;64;66 - - UNIT MOUNTED - - CONTROLLED BY FUME HOOD SWITCHES REFER TO DETAIL 4/E2-1 EF-5 208-1-60 1/3 HP 3/4"C-2#12+1#12GND 20/2 SPD;54,56 - - UNIT MOUNTED - - - EWH-1 120-1-60 8.4 FLA 3/4"C-2#12+1#12GND 20/1 PP4;69 UNIT MOUNTED - HT-1 208-1-60 17.9 FLA 3/4"C-3#10+1#10GND 30/1 PP5;7,9 ALTERNATE BID H-1. HT-2 208-1-60 17.9 FLA 3/4"C-3#10+1#10GND 30/1 PP5;11,13 ALTERNATE BID H-1 HWH-1 120-1-60 1 FLA 3/4"C-2#12+1#12GND 20/1 SDP;32 - - - - - PROVIDE WALL MOUNTED NEMA 5-20R RECEPTACLE. WIRE ASSOCAITED PUMP TO SDP;36. HWH-2 120-1-60 1 FLA 3/4"C-2#12+1#12GND 20/1 PP5;3 - - - - - PROVIDE WALL MOUNTED NEMA 5-20R RECEPTACLE. WIRE ASSOCAITED PUMP TO PP5;5. RTU-1 208-3-60 274.4 FLA 3"C-3#350kCM+1#4GND 300/3 PP4;79,81,83 UNIT MOUNTED - - 2 4 PROVIDE AND INSTALL WP GFI RECEPTACLE AND LIGHT, UNIT MOUNTED, WIRE TO PANEL "PP4" CKT 30. REFER TO DETAIL 3 RTU-2 208-3-60 50.3 MCA 1"C-3#6+1#8GND 60/3 PP4;73,75,77 UNIT MOUNTED - - 1 1 - RTU-3 208-3-60 85.15 FLA 1-1/2"C-3#1+1#6GND 125/3 SDP;79,81,83 UNIT MOUNTED - - 1 - PROVIDE AND INSTALL WP GFI RECEPTACLE AND LIGHT, UNIT MOUNTED, WIRE TO PANEL "SDP" CKT 69. REFER TO DETAIL 3 RTU-4 208-3-60 29.5 FLA 3/4"C-3#8+1#8GND 50/3 SPD;73,75,77 UNIT MOUNTED - - - - PROVIDE AND INSTALL WP GFI RECEPTACLE AND LIGHT, UNIT MOUNTED, WIRE TO PANEL "SDP" CKT 69. REFER TO DETAIL 3 UV-1 208-1-60 5.6 MCA 3/4"C-2#12+1#12GND 20/1 SDP;43 UNIT MOUNTED - - - - PROVIDED WITH CONDENSATE PUMP CUT PLUG OFF CORD AND WIRE TO SDP;62 FLORAL COOLER 208-3-60 12 FLA 3/4"C-3#12+1#12GND 20/3 SDP; 55,57,59 - UNIT MOUNTED - - - CONDENSING UNIT ON ROOF. 208-3-60 17 FLA 3/4"C-3#10+1#10GND 30/3 SDP; 61,63,65 - UNIT MOUNTED - - - ROOM CONTROL CONSOLE. PROVIDED WITH CONDENSATE PUMP, WIRE TO SDP;62 ATC CONTROL PANEL 120-1-60 1 FLA (E)WIRING 20/1 MCC-2;16 - - - - - LOCATED IN BOILER ROOM. REUSE EXISTING FEED FROM DEMOLISHED CONTROL PANEL

ELECTRICAL 112 PANEL SCHEDULE FOR PANEL: "RP1" 208/120 V, 3PH, 4W, 225A BUS, 225A M.L.O., 22,000A RMS ELECTRICAL 112 PANEL SCHEDULE FOR RELOCATED PANEL: "PP3" 208/120 V, 3PH, 4W, 100A BUS, 100A M.L.O., SQUARE D NQOB ELECTRICAL 112 PANEL SCHEDULE FOR DOUBLE PANEL: "PP5" 208/120 V, 3PH, 4W, 100A BUS, 100A M.L.O., 22,000A RMS NO POLE AMP AMP POLE NO *1 1 20 (E) OVEN No.1 RECEPTACLE (E) OVEN RECEPTACLE 20 1 2* 3 1 20 SPARE (E) FLOOR RECEPTACLES (LEFT) 20 1 4* *5 1 20 EXISTING LOAD (E) CLOSET RECEPTACLES 20 1 6* *7 1 20 (E) WASHROOM RECEPTACLES EXISTING LOAD 20 1 8* 9 1 20 SPARE (E) RECEPTACLES NEAR REFRIGERATOR 20 1 10* *11 1 20 EXISTING LOAD EXISTING LOAD 20 1 12 13 1 20 (E) WALL RECEPTACLES (LEFT) (E) EXHAUST FAN 20 1 14 15 1 20 (E) WALL RECEPTACLES (BETWEEN) (E) EXHAUST FAN 20 1 16 17 1 20 (E) WALL RECEPTACLES (RIGHT) SPARE 20 1 18 19 1 20 (E) STORAGE LIGHTING (E) KITCHEN (FRONT) LIGHTING 20 1 20 21 1 20 (E) CLOSET LIGHTING (E) KITCHEN (LEFT) EMERGENCY LIGHTING 20 1 22 23 1 20 (E) EXHAUST FAN (RIGHT) EXISTING LOAD 20 1 24 25 1 20 (E) EXHAUST FAN (RIGHT) (E) RANGE IN-HOOD LIGHTS 20 1 26 27 1 20 (E) FLOOR RECEPTACLES (LEFT) (E) RANGE ON-HOOD LIGHTS 20 1 28 29 1 20 (E) DRYER RECEPTACLES (E) WASHING MACHINE LIGHT 20 1 30 31 1 20 (E) DRYER RECEPTACLES (E) UNIT HEATER 20 2 32 33 1 20 (E) KITCHEN LIGHTING (RIGHT) 34 35 1 20 SPARE SPARE 20 1 36 37 1 20 SPARE SPARE 20 1 38 39 1 20 SPARE SPARE 20 1 40 41 1 20 SPARE SPARE 20 1 42 * DENOTES CIRCUITS THAT EXIT THE BOTTOM OF THE DEMOLISHED PANEL. THESE CIRCUITS SHALL BE DEMOLISHED AND REWIRED WITH 3/4"C-2#12+1#12GND. ASSUME 60 FEET OF CABLE AND CONDUIT FOR EACH CIRCUIT FROM NEW PANEL LOCATION TO EXISTING DEVICE. ALL OTHER EXISTING CIRCUITS SHALL BE SPLICED IN A JB ABOVE THE CEILING AND EXTENDED TO NEW PANEL LOCATION. EXISTING FEEDER SHALL BE DEMOLISHED. CONTRACTOR SHALL TRACE FEEDER TO CONFRIM PANEL IS WIRED TO (E)MCC-1 IN BOILER ROOM AND RELABEL BREAKER AS SPARE. EC SHALL TRACE ALL BRANCH CIRCUITS AND SHALL PROVIDE AS BUILT DRAWING AND PANEL SCHEDULE. SCIENCE LAB 115 PANEL SCHEDULE FOR PANEL: "SDP" 208/120 V, 3PH, 4W, 400A BUS, 300A M.C.B., 22,000A RMS SERVICE ENTRANCE RATED NO POLE AMP A B C A B C AMP POLE NO 1 1 20 SCIENCE LAB RM. 115 LIGHTING 1416 944 SCIENCE LAB RM. 115 LIGHTING 20 1 2 3 1 20 SCIENCE LAB RM. 116 LIGHTING 1062 211 PREP. ROOMS 117&118 LIGHTING 20 1 4 5 1 20 CORRIDOR LIGHTING 246 240 GAS RELAY PANELS 20 1 6 7 1 20 SCIENCE LAB 116 TABLE RECEPTACLES 720 720 SCIENCE LAB 116 TABLE RECEPTACLES 20 1 8 9 1 20 SCIENCE LAB 116 TABLE RECEPTACLES 720 720 SCIENCE LAB 115 TABLE RECEPTACLES 20 1 10 11 1 20 SCIENCE LAB 115 TABLE RECEPTACLES 720 720 SCIENCE LAB 115 TABLE RECEPTACLES 20 1 12 13 1 20 SCIENCE LAB 116 RECEPTACLES 360 1080 SCIENCE LAB 116 RECEPTACLES 20 1 14 15 1 20 SCIENCE LAB 116 RECEPTACLES 720 900 SCIENCE LAB 116 RECEPTACLES 20 1 16 17 1 20 SCIENCE LAB 116 GOGGLE CASE RECEPTACLE 600 960 SCIENCE LAB 116 REFRIGERATOR RECEPTACLE 20 1 18 19 1 20 SCIENCE LAB 116 DISHWASHER RECEPTACLE 1920 820 SCIENCE LAB 116 FUME HOOD RECEPTACLE 20 1 20 21 1 20 SCIENCE LAB 116 RECEPTACLES 540 360 CORRIDOR RECEPTACLES 20 1 22 23 1 20 SCIENCE LAB 115 RECEPTACLES 900 600 SCIENCE LAB 115 GOGGLE CASE RECEPTACLE 20 1 24 25 1 20 SCIENCE LAB 115 RECEPTACLES 720 360 SCIENCE LAB 115 RECEPTACLES 20 1 26 27 1 20 SCIENCE LAB 115 DISHWASHER RECEPTACLE 1920 960 SCIENCE LAB 115 REFRIGERATOR RECEPTACLE 20 1 28 29 1 20 SCIENCE LAB 115 FUME HOOD RECEPTACLE 820 900 SCIENCE LAB 115 RECEPTACLES 20 1 30 31 1 20 LIFT DISCONNECT 1656 120 HWH-1 15 1 32 33 1 20 ELECTRICAL SHUT DOWN PANEL 500 369 EXTERIOR BUILDING LIGHTING 20 1 34 35 1 20 SMARTBOARD 360 65 HWH-1 PUMP 15 1 36 37 1 20 SMARTBOARD 360 250 FIRE ALARM BOOSTER PUMP 20 1 38 39 1 20 SPARE 0 912 40 ROLLING DOOR 20 2 41 1 20 SPARE 0 912 42 43 1 20 UV-1 538 1788 AHU-3/HP-3 20 1 44 45 1 20 SPARE 0 1788 AHU-3/HP-3 20 1 46 47 1 20 SPARE 0 0 SPARE 20 1 48 49 1 20 SPARE 0 0 SPARE 20 1 50 51 1 20 SPARE 0 0 SPARE 20 1 52 53 1 20 SPARE 0 480 54 EF-5 20 2 55 1440 480 56 57 3 20 FLORAL COOLER CONDENSING UNIT 1440 1656 EF-2 25 1 58 59 1440 1656 EF-3 25 1 60 61 2040 1524 CONDENSATE PUMPS 20 1 62 63 3 30 FLORAL COOLER 2040 480 64 EF-4 20 2 65 2040 480 66 67 1 20 PHOTO CELL 500 2184 68 AHU-5/HP-5 35 2 69 1 20 ROOF TOP RECEPTACLES AND LIGHTS 720 2184 70 71 1 20 CUH-1 264 0 SPARE 20 1 72 73 3540 1728 74 75 3 50 RTU-4 3540 1728 CU-1 30 3 76 77 3540 1728 78 79 10218 80 81 3 125 RTU-3 10218 82 83 10218 84 NO POLE AMP AMP POLE NO 1 2 (E) ROOF TOP AC No. 117 30 2 3 3 20 (E) WALKIN BOX 4 5 SPACE - 1 6 7 (E) RECEPTACLES 20 1 8 9 3 20 (E)FOOD WARMER (E) RECEPTACLES 20 1 10 11 (E) RECEPTACLES 20 1 12 THIS PANEL IS TO BE RELOCATED. ALL FEEDER AND BRANCH CIRCUITS FOR THIS PANEL ARE WIRED THROUGH (E)PANEL "PP2". PROVIDE A NEW WIRING TROUGH NEXT TO (E)PANEL "PP2" TO BE USED FOR SPLICING AND EXTENDING FEEDER AND BRANCH CIRCUITS. ASSUME 4#1+1#8GND FOR THE FEEDER, #12'S FOR ALL CIRCUITS ACCEPT FOR 2,4 WHICH SHALL BE #10. ELECTRICAL 112 NO POLE AMP A B C A B C AMP POLE NO 1 1 20 REFRIGERATOR 576 948 OVERHEAD WARMER 20 1 2 3 750 1380 4 2 20 HEATED PASS THRU CABINET REFRIGERATED SELF SERVE CASE 30 2 5 750 1380 6 7 1380 864 DROP IN FREEZER ICE CREAM 20 1 8 2 30 REFRIGERATED SELF SERVE CASE 9 1380 1584 BACKSTOP 20 1 10 11 1380 1584 BACKSTOP 20 1 12 2 30 REFRIGERATED SELF SERVE CASE 13 1380 1584 BACKSTOP 20 1 14 15 1728 1584 BACKSTOP 20 1 16 2 20 HOT, COLD, FREEZE DROP-IN 17 1728 1584 BACKSTOP 20 1 18 19 1 20 HEATED BLACK GLASS 600 1584 BACKSTOP 20 1 20 21 1 20 OVERHEAD WARMER 948 288 PROJECTION SCREEN 20 1 22 23 1440 288 PROJECTION SCREEN 20 1 24 2 20 HOT, COLD, FREEZE DROP-IN 25 1440 1656 GYM DIVIDER MOTOR 20 1 26 27 1 20 COLD PAN 696 264 PROJECTOR LIFT 20 1 28 29 1 20 REFRIGERATED BASE 696 1080 ROOF TOP RECEPTACLES AND LIGHTS 20 1 30 31 1 20 KITCHEN COUNTER RECEPTACLES 360 360 CAFETERIA FLOOR RECEPTACLES 20 1 32 33 1440 540 CAFETERIA COUNTER RECEPTACLES 20 1 34 2 20 HOT, COLD, FREEZE DROP-IN 35 1440 360 CASHIER RECEPTACLES 20 1 36 37 1000 720 CAFETERIA COUNTER RECEPTACLES 20 1 38 2 20 HEATED BASE 39 1000 1440 40 HOT, COLD, FREEZE DROP-IN 20 2 41 1 20 HEATED BLACK GLASS 600 1440 42 ELECTRICAL 112 PANEL SCHEDULE FOR DOUBLE PANEL: "PP4 LEFT" 208/120 V, 3PH, 4W, 600A BUS, 600A M.L.O., 22,000A RMS 6736 7942 8034 7716 7080 7716 PANEL SCHEDULE FOR DOUBLE PANEL: "PP4 RIGHT" 208/120 V, 3PH, 4W, 600A BUS, 600A M.L.O., 22,000A RMS NO POLE AMP A B C A B C AMP POLE NO 43 1 20 AHU-1/HP-1 1788 792 CUH-3, CUH-4, CUH-8 20 1 44 45 1 20 AHU-2/HP-2 1788 1056 CUH-2, CUH-5, CUH-6, CUH-7 20 1 46 47 1 20 PROJECTOR LIFT 264 1656 EF-1 25 1 48 49 1 20 SCOREBOARD 1200 1440 MULTI-PURPOSE ROOM 100 RECEPTACLES 20 1 50 51 1 20 SCOREBOARD 1200 720 MULTI-PURPOSE ROOM 100 RECEPTACLES 20 1 52 53 1 20 MULTI-PURPOSE RM. 100 LIGHTING 966 360 WATER COOLER RECEPTACLE 20 1 54 55 1 20 MULTI-PURPOSE RM. 100 LIGHTING 966 1080 TOILET RMS. 104&105, LOCKER RMS. 103&106 RECEPTACLES 20 1 56 57 1 20 MULTI-PURPOSE RM. 100 LIGHTING 966 1260 OFFICES 102&107, CORRIDOR C-1A RECEPTACLES 20 1 58 59 1 20 MULTI-PURPOSE RM. 100 LIGHTING 966 900 STORAGE RMS. 101&108, CUST. CLOSET 109 RECEPTACLES 20 1 60 61 1 20 CAFETERIA RM. 111 LIGHTING 717 1260 STORAGE RM. 111A, CORRIDOR C-1 RECEPTACLES 20 1 62 63 1 20 HALL H-1 LIGHTING 657 720 OUTSIDE BUILDING RECEPTACLES 20 1 64 65 1 20 MULTIPLE ROOM LIGHTING-BELOW MULIT PURPOSE RM. 100 1062 180 DATA CLOSET RECEPACLE 20 1 66 67 1 20 MULTIPLE ROOM LIGHTING-BELOW MULIT PURPOSE RM. 101 889 180 DATA CLOSET RECEPACLE 20 1 68 69 1 20 EWH-1 1008 180 DATA CLOSET RECEPACLE 20 1 70 71 1 20 CONDENSATE PUMPS 528 180 STORAGE 110 PA RACK RECEPTACLE 20 1 72 73 4829 6674 74 75 3 60 RTU-2 4829 4117 PANEL "PP5" 100 3 76 77 4829 2713 78 79 32640 80 81 3 300 RTU-1 32640 82 83 32640 84 43028 43088 41255 11426 8053 5989 PHASE A: 14.45 KVA PHASE B: 15.02 KVA PHASE C: 15.75 KVA TOTAL: 45.22 KVA NO POLE AMP A B C A B C AMP POLE NO 1 1 20 AC-2/CU-2 960 520 SITE LIGHTING 20 1 2 3 1 15 HWH-2 120 451 EXTERIOR BUILDING LIGHTING 20 1 4 5 1 15 HWH-2 PUMP 65 250 FIRE ALARM BOOSTER 20 1 6 7 2148 250 DOOR ACCESS JB 20 1 8 2 30 HT-1 9 2148 250 DOOR ACCESS JB 20 1 10 11 2148 250 DOOR ACCESS JB 20 1 12 2 30 HT-2 13 2148 648 14 FIRE SHUTTER 20 2 15 1 20 SMOKE DAMPERS 500 648 16 17 1 20 SPARE 0 0 SPARE 20 1 18 19 1 20 SPARE 0 0 SPARE 20 1 20 21 1 20 SPARE 0 0 SPARE 20 1 22 23 1 20 SPARE 0 0 SPARE 20 1 24 25 1 20 SPARE 0 0 SPARE 20 1 26 27 1 - SPACE 0 0 SPACE - 1 28 29 1 - SPACE 0 0 SPACE - 1 30 31 1 - SPACE 0 0 SPACE - 1 32 33 1 - SPACE 0 0 SPACE - 1 34 35 1 - SPACE 0 0 SPACE - 1 36 37 1 - SPACE 0 0 SPACE - 1 38 39 1 - SPACE 0 0 SPACE - 1 40 41 1 - SPACE 0 0 SPACE - 1 42 GIRLS LOCKER ROOM 5256 2768 2213 1418 1349 500 PANEL SCHEDULE FOR DOUBLE PANEL: "GL1" 208/120 V, 3PH, 4W, 100A BUS, 100A M.L.O., 65,000A RMS PHASE A: 6.67 KVA PHASE B: 4.12 KVA PHASE C: 2.71 KVA TOTAL: 13.50 KVA NO POLE AMP A B C A B C AMP POLE NO 1 1 20 (E) FIRE ALARM BOOSTER 0 0 SPARE 20 1 2 3 1 20 SPARE 0 0 SPARE 20 1 4 5 1 20 SPARE 0 0 SPARE 20 1 6 7 1 20 SPARE 0 0 SPARE 20 1 8 9 1 20 SPARE 0 0 SPARE 20 1 10 11 1 - SPACE 0 0 SPACE - 1 12 13 1 - SPACE 0 0 SPACE - 1 14 15 1 - SPACE 0 0 SPACE - 1 16 17 1 - SPACE 0 0 SPACE - 1 18 19 1 - SPACE 0 0 SPACE - 1 20 21 1 - SPACE 0 0 SPACE - 1 22 23 1 - SPACE 0 0 SPACE - 1 24 25 1 - SPACE 0 0 SPACE - 1 26 27 1 - SPACE 0 0 SPACE - 1 28 29 1 - SPACE 0 0 SPACE - 1 30 31 1 - SPACE 0 0 SPACE - 1 32 33 1 - SPACE 0 0 SPACE - 1 34 35 1 - SPACE 0 0 SPACE - 1 36 37 1 - SPACE 0 0 SPACE - 1 38 39 1 - SPACE 0 0 SPACE - 1 40 41 1 - SPACE 0 0 SPACE - 1 42 0 0 0 0 0 0 PHASE A: 0.00 KVA PHASE B: 0.00 KVA PHASE C: 0.00 KVA TOTAL: 0.00 KVA 25428 23420 21148 11998 12268 8741 PHASE A: 37.43 KVA PHASE B: 35.69 KVA PHASE C: 29.89 KVA TOTAL: 103.00 KVA PHASE A: 54.45 KVA PHASE B: 51.14 KVA PHASE C: 47.24 KVA TOTAL: 152.84 KVA