alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

Similar documents
LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

Immunity. P/N: ver.b

CSB 200. Microwave barrier. Outdoor Detector 200m Range DIGILON INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

FW-KP WIRELESS KEYPAD

INSTALLATION INSTRUCTIONS

installation & operation manual

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

Advanced DIGITAL Wired PIR Motion Detector

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

Description. Optex Incorporated

Extended Range DUAL TEC Motion Sensor

Figure 1. These Installation Instructions -1- K4866 4/00 OmniProx Reader Model Series OP-10/20/30/40

Twin Photobeam Detectors Manual

External Wireless Sounder

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

FW-RA-LED Remote Multiplex Annunciator Panels

General Description. Industrial LuNAR DT AM Grade 3 Features

Long-Range Barrier Sensors

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

External Wireless Sounder

RILEVATORI DI MOVIMENTO DA INTERNO serie unum

Radar Sensor. Radar Security Detector Model No. : DND-30L/30W, DND-60L/60W, DND-90L/90W. Feature. Specification. Reference

ADVANCED ADAPTIVE TM PIR/MICROWAVE TECHNOLOGY SENSOR

WIRELESS OUTDOOR DUAL TECHNOLOGY MOTION DETECTOR AOD-200

DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

DD205RF/TX Detector Installation Sheet

SECURITY PRODUCTS CATALOGUE

English. Italiano. Português. Françias. Español

SECURITY PRODUCTS CATALOGUE

LMA LINE MONITOR ALERT USER S MANUAL

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

PIR-100B User Manual

STANDARD FEATURES SPECIFICATIONS

D-TECT Dual Tech. GJD360 Triple Technology External Detector

CZ-6A Six Zone Interface Module

D-TECT 3 IP. GJD260 IP Motion Detector

SC-6 Six Supervised Control Module

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

D-Tect 2 GJD300 Quad PIR Movement Detector

Intrusion Outdoor Protection Perimeter

LUX Hardwired - Installation Notes

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

EVD-1 Installation, Operation, and Instruction Manual

INSTALLATION INSTRUCTIONS and OPERATING GUIDE

English. Series. Installation and Use Manual

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

Active Infrared Multi Beam Sensors

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

MADE TO PROTECT OUTDOOR DUAL-TECH CURTAIN DETECTORS AGATE / AOCD-250

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

Radio Frequency Do s & Don ts

Active Infrared Multi Beam Sensors. R Series

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

D-TECT 2 IP. GJD230 IP Motion Detector

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

CLIP PG2 PowerG Wireless, Curtain, PIR Motion Detector

Commercial Series TriTech Motion Detector. Reference Guide

1126 Series Ceiling Mount PIR Motion Detector

WorkZone PreView Sensor Manual

Passive Infrared Motion Detector 5420/90P. Installation Instructions

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

Hardwired Alarm Accessories

HX-80NRAM. High Mount Outdoor Detector

RAM-208. Remote Multiplex Annunciator Panel. Wiring & Installation Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

1125 PIR Motion Detector

Figure 1. Figure 2. See notes 1 and 2 below.

PART NO: TSMS. Designed in Australia by. Instruction Manual. Factory Car Alarm Upgrade Providing Alarm Notification Via SMS Messaging N517

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

Home & Yard Alert Long Range System Home & Yard Alert Extended Long Range System

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

DI601AM Outdoor PIR/AM Detector Installation Sheet

Intrusion sensors. We listened to you

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

DH200PL Intelligent Air Duct Smoke Detector with Extended Air Speed Range

Commercial Series TriTech+ Motion Detector with Anti-mask

SEC Signature Process Gas Analyzer

PreView WorkSight. WS6220 WS6215 WS6210 Sensor Operating Manual.

4500 THERMOSTAT INSTALLATION INSTRUCTIONS

INTRODUCTION INSTALLATION N7635-3V2 8/ EN Series RF Receiver INSTALLATION AND SETUP GUIDE

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

RAM-216. Remote Multiplex Annunciator Panel. Wiring & Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE SIGNAL SILENCE

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

FEATURES OPTION 1.DESCRIPTION AND OPERATION 2.DETECTION AREA PASSIVE INFRARED AND MICROWAVE COMBINATION DETECTOR. No.

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

D2E Duct Smoke Detector

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

Transcription:

ELECTRONIC ENGINEERING LTD. MRX-300N Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL P/N 7101297 Rev. A Y.S/A.Y 1

The MRX-300N is unique PIR and Microwave detector for outdoor and harsh environment applications. It comprises Double Dual Mirror Optics and advanced Doppler detector inside stylist rigid plastic body. The Mirror DOUBLE DUAL optics improves the focus and the level of energy received by the Pyro Sensor. This special mirror optics combined with state of the art MW Doppler sensor assures eliminating of false alarms while maintaining high security standards for the detection of human intruders into a protected area. The detection sensitivity and range is controlled by digital rotary switch allowing 16 calibration levels, so that the effective pattern will be set for every installation environment and protection site. The MRX-300N is designed to protect large areas and can easily be installed on any type of wall in order to provide a solid protection of the area while rejects interferences alarm of birds and small animals due to shop patented PET MASK optics. The MRX-300N is designed for continuous round-the-clock operation and keeps its characteristics within a wide temperature and humidity range. MRX-300N 2

MRX 300N FEATURES DOUBLE DUAL PYRO sensor. Full pattern double mirrors optics. MW detection based on Doppler concept. FET based DRO with strip line antenna. VLSI based electronics with movement speed spectrum analysis. N.O. & N. C. Relays switched at the same time. Height installation calibrations free, from 1.5m to 3.0m Pet Immunity up for pet and small animals up 40kg. 16 levels of MW and PIR sensitivity adjustment. Environmental immunity. Temperature compensation. Micro controller signal processing. Tamper and tilt full protection. Walk test and detection sound indication. Unique waterproof and seal plastic design. Detection Range: Up to 40m (with LR Mirrors) Detect human intruders walking, running or crawling. No maintenance required. High RFI/EMI Immunity. Protection from: direct sunlight, wind up to 30 m/sec, snow and rain, small animals, removing the top cover, housing pulling out or destruction. 3

Selecting mounting location The installation of the MRX-300N requires straight and solid base for the detector and setting of front panel against the center of protected area. Local conditions of the protected zone must be free from obstacles like walls, fences, trees and ditches or other microwave detectors and systems of anti-intrusion surveillance. The bracket provides MRX-300N installation on the wall, allows changing the installation angle (vertically and horizontally) in wide range (FIG.2). The wall should be leveled with a maximum slope angle of 10. Choose a location most likely to intercept an intruder according to detection pattern in FIG.: 6. Avoid the following Installation Locations: Facing direct sunlight. Facing alarm areas subject to rapid temperature changes. shop Wall angle of more then 10º from perpendicular line. Mounting at more then 10º Deviation from horizontal line. Facing metal doors. Avoid installation of MRX-300N on the following type of ground: Thick vegetation, Grass (un-mown), Water, Sand and a Metal. NOTE: Recommended installation height is 3m. The DOUBLE DUAL high quality sensor detects motion crossing the beam; it is less sensitive detecting motion towards the detector. The MRX-300N performs best when provided with a constant and stable environment. In order to ensure suitable operation of the MRX-300N type of ground should be one of the following: Asphalt, Cement, Soil, Clay, Gravel or Grass (mown). 4

Mounting the detector Fig.1. Cover opening Fig.2. Wiring and and Installation positioning Use the MRX-300N back bracket for wall installation. Remove top cover by unscrew the holding screw at the bottom side of the bracket. Attach bracket to the wall using 4 screws and anchors (See fig. 1). Insert the wire through the line/hole wire bracket under silicon gasket (See fig. 2). Access for wiring connections is easy via the terminal block located on the PCB. See fig. 3. For detector alignment, unscrew the plastic wing nut, adjust the detector facing against the center of protected area and straighten the nut. Replace the detector top cover. Screw the holding screw. 5

TERMINAL BLOCK CONNECTIONS - 12V + EOL NC C NO EOL TAMPER EOL 1 2 3 4 5 6 7 8 9 10 Fig.3. Wiring connections Terminal 1 - Marked - (GND) - Connect to the ground of the control panel. Terminal 2 - Marked + (+12V) - Connect to a positive Voltage of 8.2-16Vdc source (usually from the alarm control unit) Terminals 4,5 & 6 - Marked NC C NO - These are the output relay contacts of the detector. Connect to a normally closed or normally opened zone in the control unit. When an intruder is detected, alarm relays (N.O. and N.C.) will switch for 1.8 sec. Terminals 8 & 9 - Marked TAMPER - If a Tamper function is required connect these Terminals to a 24-hour normally closed protective zone in the control unit. If the top cover of the detector is opened or the detector is detached from installation wall, an immediate alarm signal will be sent to the control unit. Terminals 3,7 & 10 - Marked EOL - End of line optional terminals for end of line resistors connections. WIRE SIZE REQUIREMENTS Use #22 AWG or larger wires. Use the following table to determine required wire gauge and length. Wire Gauge: # 22 20 18 16 Wire Length: m 205 310 510 870 Ft. 800 1200 2000 3400 6

TOP PCB LAYOUT Block Connector Tilt Mode Jumper (JP4) Buzzer Mode Jumper (JP3) LED Mode Jumper (JP2) Rotary Switch Fig.4. Interface PCB layout LED INDICATORS YELLOW LED - MW detection, is blinking during warm up period and self testing GREEN LED - PIR detection RED LED - Alarm 7

TEST AND TUNING SENSITIVITY AND RANGE ADJUSTMENT The calibration of range and sensitivity is performed by single digital 16 position rotary switch. There are 3 groups of switch setting according to detection range. Each group is divided to several levels of sensitivity according to installation environment. The sensitivity levels values changed upon the mirror optic type. 0 Noise Area F 1 WA Low Risk Risk High Risk Very High Risk E 2 Very High Risk alarm High Risk D 3 LR shop Noise Area High Risk Risk C 4 Extreme Noise Area Low Risk Low Risk B 5 A 6 WA LR 7 9 8 Low Risk Low Risk 15m WA 7m 21m Risk 28m 40m LR Low Risk High Risk High Risk 15m High Risk Installation Hight: 3m Bracket Angle: 0 Very High Risk Noise Area Fig.5. Rotary switch setting 8

For WA (Wide Angle) mirror optic TOP VIEW WA mirror 90.5 (PIR) 10m 5m MW pattern 0m 21m 30m 5m 10m ` SIDE VIEW 2.4m 5m 10m 21m 30m Fig.6. WA PIR + MW Detection Pattern Group alarm A - positions 0 5 set sensitivity for 21m shop detection range Group B - positions 6 A set sensitivity for 15m detection range Group C - positions B F set sensitivity for 7m detection range For LR (Long Range) mirror optic (optional Model MRX-300N-LR) Group A - positions 0 and 1 set sensitivity for 40m detection range Group B - positions 6 and 7 set sensitivity for28m detection range Group C - positions B and C set sensitivity for 15m detection range Each range group includes 5 or 6 setting levels according to environmental condition risk. For example: If detector is used for 15m range in open space with sunlight set switch to position 8 or 9. 9

JUMPERS SETTING LED Mode Jumper (JP2) Connect a jumper between the marked terminals to enable or disable the LED (ON or OFF). LED OFF OFF LED ON LED ON OFF LED ON Buzzer Mode Jumper (JP3) Buzzer provides the sound indication of Alarm signal. If a buzzer function is required, connect a jumper in position ON, if it is not required in position OFF. BUZZER OFF Buzzer OFF ON OFF alarm Buzzer ON shop ON The buzzer function is useful during walk test when sunlight dazzling the LED. Tilt Mode Jumper (JP4) Two tilts protect detector from undesirable attempts to pull off from installation place. Tilts fix position change also in horizontal and vertical directions and send signal to Tamper terminals. If a tilt function is required, connect a jumper in position ON, if it is not required in position OFF. Tilt OFF BUZZER OFF TILT ON Tilt ON OFF TILT ON You must reset the detector from Control Panel before the new settings will take effect 10

Test procedure Walk Test After tuning the sensitivity, connect 12Vdc power to the system. Allow 2 minute warm-up time. Make sure that the protected area is cleared of all people. 1. Start walking slowly across the detection zone. 2. Listen to ALARM sound whenever motion is detected (The red LED lights also whenever motion is detected). 3. Allow 5 sec. between each test for the detector to stabilize. NOTE: Walk Test procedure should be conducted, at least once a year, to confirm proper operation and coverage of the detector. 11

SPECIFICATIONS Optic Detection Method WA Mirror Pattern Microwave Frequency Microwave Output Power Microwave Harmonic emission Scope (Length of protection zone) Power Supply Voltage DOUBLE DUAL element PIR & MW 90.5 with 30 zones detection 10.525 GHz +/-3MHz Min. + 13dBm IERP - 7.3dBm Max. 21m (WA mirror) max10. 40m (LR mirror) 8.2...16 V Current consumption Active: 27mA ± 3mA Standby: 17mA ± 3mA Relay contacts values N.C 28Vdc 0.1 A with 10 Ohm protection resistors N.O 28Vdc 0.1 A with 10 Ohm protection resistors Warm up Period 120 Sec (Max.) Alarm Period 1.8 Sec (Max.) N.C 28 Vdc Maximum current 0.1 A - open when Tamper Switch cover is removed Detection Speed (Target velocity) 0.3... 3 m/sec Dimensions of unit with bracket Weight Operating temperature range Weatherproofing RFI Protection EMI Protection Visible Light Protection 192mm x 153mm x 251mm 0.55 Kg -20 C ~ +60 C All openings with gasket and sealed IP 65 compatible 30V/m 10 1000 MHz 50,000V of electrical interference from lightning or power through Stable against halogen light, sunlight or reflecting light * Specifications are subject to change without prior notice. 12

CROW LIMITED WARRANTY (CROW) warrants this product to be free from defects in materials and workmanship under normal use and service for a period of one year from the last day of the week and year whose numbers are printed on the printed circuit board inside this product. CROW s obligation is limited to repairing or replacing this product, at its option, free of charge for materials or labor, if it is proved to be defective in materials or workmanship under normal use and service. CROW shall have no obligation under this Limited Warranty or otherwise if the product is altered or improperly repaired or serviced by anyone other then CROW. There are no warranties, expressed or implied, of merchantability or fitness for a particular purpose or otherwise, which extend beyond the description on the face hereof. In no case shall CROW be liable to anyone for any consequential or incidental damages for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever, even if the loss or damage is caused by CROW s own negligence or fault. CROW does not represent that this product can not be compromised or circumvented; that this product will prevent any person injury or property loss or damage by burglary, robbery, fire or otherwise; or that this product will in all cases provide adequate warning or protection. Purchaser understands that a properly installed and maintained product can only reduce the risk of burglary, robbery or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result. Consequently, CROW shall have no liability for any personal injury; property damage or any other loss based on claim that this product failed to give any warning. However, if CROW is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, CROW s maximum liability shall not in any case exceed the purchase price of this product, which shall be the complete and exclusive remedy against CROW. 13

ELECTRONIC ENGINEERING LTD. ISRAEL: USA: CROW ELECTRONIC ENGINEERING LTD. 57 Hamelacha St., Holon 58855 Tel: +972-3-5569937 Fax: +972-3-5592981 E-mail: support@crow.co.il CROW ELECTRONIC ENGINEERING LTD. 2160 North Central Road, Fort Lee, N.J. 07024 Tel: 1-800-GET-CROW or +201-944-0005 Fax: +1-201-944-1199 E-mail: crow@nis.net AUSTRALIA: alarm CROW AUSTRALIA shop PTY. LTD. 429 Nepean HWY Brighton East Vic 3187 Tel: +61-3-9596-7222 Fax: +61-3-9596-0888 E-mail: crow@crowaust.com.au POLAND: VIDICON UL. PLOCKA 17, 01-231 WARSZAWA, POLAND Tel: +48-22-632-5543 Fax: +48-22- 631-3808 E-mail: vidicon@vidicon.pl LATIN AMERICA: ITALY: CROW LATIN AMERICA 168 SE IST Street, Suite # 501, MIAMI, FL 33131 USA Tel: +1-305-372-0334 Fax: +1-305-372-8053 E-mail: crowlatinamerica@aol.com DEATRONIC VIA Giulianello 4/14 00178 ROMA, ITALY Tel: +39-0676-12912 Fax: +39-0676-12601 E-mail: info@deatronic.com 14