TT302 (200W) Wireless receiver Pull cord Dimmer

Similar documents
Foil Heaters. Installation Manual: TECHNICAL HELPLINE

ECOLEC PANEL HEATERS GENERAL NOTES.

Installation & User Instructions: Model: e600s e600gf e700s e1000s e1000gf e1030gf/2/3 e1500gf/2/3

Installation & User Instructions:

Operation Manual Model: Light Switch Combo Universal Dimmer Module Item No.: WMR-252. Specification. Wiring

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

Installation & User Instructions: Model: Arizona/Broadway/Corsano/Compton/Compton1000/Corbiere/Empire /Newark/Newark1000/Qube/Tribeca

PUDDLE PUMP PUDDLE PUMP. MODEL No: PSP125 OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

DEVIL CERAMIC SPACE HEATERS

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

MAJIK ENGLISH 11/20/02 11:30 AM Page 1 M A J I K O W N E R S M A N U A L

Safety and Instruction Manual

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

identity installation & maintenance instructions customer/technical services guarantee

Guide to sollysta Wiring Accessories

Electronic Thermostat With RF

HERSCHEL SUMMIT 2600 HERSCHEL SUMMIT 2600R Ceiling or Wall-mounted Infrared Heaters

Installation Manual. Frost Protection Cable. Warmup Ireland Web: Telephone:

ART cm Island Curved Glass

Electronic Instantaneous Water Heaters Models: ES3, ES4 & ES6

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

PERFORMANCE SLIMMING BELT

Conception Wall Fire. Instruction Manual THE SCIENCE BEHIND CLEAN.

GEM-C Wireless User & Installation Manual. Revision October Apollo Solar Electric Limited. Documentation

52 CEILING FAN. Owner s Manual Models #50336, 50337

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

Pie Warmer. Instruction manual. Model: GF454-A/GF455-A

Universal Fan and Light Remote Control

Underfloor Heating Inscreed Cable System

CLEAN WATER PUMP. MODEL No: Hippo4A OPERATION & MAINTENANCE INSTRUCTIONS. Part No:

Installation Instructions

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

TIMEGUARD WEATHERSAFE OUTDOOR POWER RANGE INSTALLATION & OPERATING INSTRUCTIONS


Ecostrad Amalfi. Wall-mounted Infrared Heater INSTALLATION & OPERATING INSTRUCTIONS. 3kg 2 Years (excludes lamp & remote control) IP65

CentaurPlus ZW and HRT4-ZW

CR9986. Please read this manual before use. Dual Alarm CD Clock Radio 5/19/2005, 8:28 AM. Sound for Generations ROBERTS. CR9986 Rev 1.

Mi HOME INSTALLATION AND INFORMATION GUIDE. Mi Home

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

Hozelock Ltd. Midpoint Park, Birmingham B76 1AB. England Tel: +44 (0)

ISCG90SS _03 ISCG90SS

CG60/ 70/ 80/ 90/ 100 SS/BK

Electrisaver User and Installation Instructions

18 INCH HIGH VELOCITY FLOOR FAN

ROBERTS. FM / MW dual alarm clock radio with instant time set. Please read this manual before use

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

Dimmer Switch (3 Gang)

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR CARE GIFT SET MODEL C85003

Universal Dimmer E450UD Series. Installation Instructions

From.

SUBMERSIBLE WATER PUMPS

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

INSTRUCTION MANUAL MNBX14

SURFACE WARM CEILING HEATERS

USE & CARE MANUAL INSET ELECTRIC FIRE WITH DOWNLIGHTS. CO9145 V1_140812

WARNING: THIS APPLIANCE MUST BE EARTHED. Replacing fuse covers: Replacement fuse covers: Changing the plug: Removing the plug. Disposing of the plug

FW422. Integrated In Column Larder Fridge. Installation, use and maintenance.

On/off button with booster (max) function* Fine filter Prefilter. Dust container Release button Charging indicator light. Vacuum cleaning cover

PERSONAL HEATER OWNER S GUIDE

Installation and Safety Instructions Cone Wall Light with PIR Stainless Steel Model: S083S

IMPERIAL FIRES CAST 1 / 2 INSTRUCTIONS IMPERIAL FIRES LTD. SAXON BUSINESS PARK HANBURY ROAD STOKE PRIOR BROMSGROVE B60 4AD

model VH200 vornado.com WHOLE ROOM HEATER OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

CR9976 ROBERTS. Auto Set Dual Alarm CD Clock Radio. Sound for Generations. Please read this manual before use

52 BERKSHIRE CEILING FAN

MEH600/900 MEP600/900 Extractors. Manual for Installation, Use and Maintenance

Operating Instructions

12W Round LED Wall/Ceiling Light with Microwave Sensor

STEAM WALLPAPER STRIPPER MODEL HTW5

USE & CARE MANUAL WALL HANGING FIRE. CO9126 V2_110512

DIMAX DIMAX D GB F I E NL. Installation and operating instructions Universal dimmer DIMAX 532. Minimum DIMAX 532.

START-LINE Receiver ACD-200. SMART Home USER MANUAL. Version 1.0 Visit for the most recent user manuals MAINS SOCKET DIMMER

LOW TEMPERATURE DEHUMIDIFIER DES 80 OWNER S MANUAL

TOUCHDOWN 48 CEILING FAN

Heated Display Merchandiser. Instruction Manual. Models: GC875-A / GC876-A / GC877-A

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

100cm Chimney Hood GB IE

Curv-infrared.com. The Smarter Way. To Heat Your Home. Installation & Operating Instructions For Cürv, Flat, Towel Rail and Mirror Infrared Heaters

Box60/ 70/ 90. Box60_70_90 v8

Whole Room Dryer WRD, WRD/110

CARMEL 48 CEILING FAN

SPRINGHILL 44 CEILING FAN

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Installation instructions

200W Frostwatch Radiant Heater Operation Manual

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

SC2000Y, SC2000YST, SC2000YM

PTC Tower Heater. Instruction Manual THE SCIENCE BEHIND HEAT.

User Instruction Manual

EVX101 Extractor Installation, Use and Maintenance

Owner s Manual. Digital Thermostat. Non-Programmable

Space Saver. Installation and user manual. Issue 001 March 2018 ENGLISH UK IRL SmithsEP.co.uk. Issue March 2018 smithsep.co.

Surface Warm Ceiling Heaters

ORIGINAL INSTRUCTIONS

CR9934 ROBERTS. PLL Dual Alarm Clock Radio. Sound for Generations. Please read this manual before use

EVG Extractors. Manual for Installation, Use and Maintenance

Installation & Operating Instructions. Models: Desire, Ignite & Hereford Electric Stoves

User Instruction Manual

ELECTRIC WALL HANGING FIREPLACE SUITE FUI0005_V2_ USE & CARE MANUAL

ITEM # BUILDER S SERIES CEILING FAN MODEL #41391

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

Transcription:

TT302 (200W) Wireless receiver Pull cord Dimmer Product Description The TT302 Wireless receiver allows you to convert a standard 1 way light switch or pull cord in to a taptile compatible Dimmer circuit and is designed to be paired only with buttons 4 or 5 on the Taptile Sensor. Product Compatibility For use with or in series with incandescent lighting only. The following lighting types are NOT compatible with the TT402 Wireless Inline Dimmers: G23, Metal Halide High Pressure sodium, CLF, Linear/Compact Fluorescents (non dimmable), SLE PRO, PLE C Pro, Single Ended High Pressure Lamps, Non dimmable LED lamps The TT 402 Wireless Inline Dimmers are COMPATIBLE with the following lighting types: G9 Strip & Architectural PAR30 PAR36 SES (Candle/Round PAR38 PAR20 GLS BC GLS ES GU10 SBC (Candle/Round) K1/9/11/12 G4 G6.35 MR16 MR11 NOTE: The performance of dimmable compact fluorescent bulbs is subject to user preference, as flickering may occur. NOTE: Dimmable LEDs bulbs must provide sufficient load in order to allow the TT402 to function. Wiring multiple bulbs increase the load on the TT402.

Product Specifications: Pull cord Dimmer: TT302 Power: 230V ~ 50Hz Max Load 210W (Incandescent Lighting) Internal Fuse: 2A, 130 degrees Celsius Range: 30 Metres (Open Distance) Frequency: 433.92MHz Indoor Use Only Warning: Never Exceed the Product Specification INSTALLATION WARNINGS: BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY Always read the instructions carefully before starting any installation and keep them for future reference. If you are in any doubt on the installation process, consult a qualified electrician. This product should be installed in accordance with the relevant sections of the building regulations code, and the current edition of the IEE Wiring Regulations (BS 7671: Requirements for electrical installations) and appropriate statutory regulations. Do not install dimmable receivers on lighting circuits used to supply other products such as extractor fans and shaver socket outlets. Do not exceed the Taptile Sensor s Maximum Power Rating of 210W. As of 1st April 2004, new installations in the UK should be wired using the EU harmonised colours for the supply conductors: New colours: BROWN = Live BLUE = Neutral Earth = Yellow/Green Old colours: RED = Live BLACK = Neutral The old colours ceased in April 2006. Electrical installations in bathrooms, kitchens, gardens, floor and heating systems, swimming pools, saunas and extra low voltage lighting are classed as special installations and must be certified by an approved competent electrical contractor conforming to Part P, requirements of BS 7671:2001 and appropriate statutory regulations.

Installation: Do not use the Wireless Pull cord Dimmer with low voltage lighting transformers, fluorescent bulbs, and energy saving lighting or fans, incorrect installation may damage the Wireless Pull cord Dimmer. In case of any doubt consult a qualified electrician. 1. Isolate from the mains supply, then remove the existing switch and disconnect the wiring from the switch terminals on the back of the light switch. 2. Ensure the wall box is free from plaster, projecting screw heads or any other debris. The Pull cord Dimmer is designed to fit into a 25mm back box, if required a deeper back box or a proprietary spacer can be used between the Pull cord Dimmer and the wall. 3. Wire the mains cable to the Pull cord Dimmer following the diagram below: Making sure the live cable is connected to " " terminal and, the switch live wire to the " " terminal. 4. Connect the two switching wires from the Pull cord Dimmer to the original light switch, making sure 1 way operation is used. 5. Make sure all terminals and earth connections are correctly wired, secure and no bare wire is showing. 6. Reconnect the mains supply ensuring that the Dimmer is secure and no wires can cause harm or short out. You will now need to program the Wireless Pull cord Dimmer Please refer to your Taptile installation manual for the pairing procedure. Alternatively instructions for pairing the Taptile Sensor can be downloaded from our website at: http://www.taptilecontrols.com 7. Replace the switch cover making sure no wires are trapped between the switch plate and the wall. Do not over tighten the switch plate as this could crack or distort the switch.

Interference Occasionally receivers can interfere with each other. It is therefore recommended that receivers are not placed with in 1 meter of each other For low voltage products the transformer should be sited as far away from the receiver as possible. RF Range The radio signals operating distance is reduced when the signal has to pass through walls or ceiling. The radio signals will reduce significantly with foil coated ceilings, or metallic coated loft insulation. Please consider placement, and allow for potential movement if radio reception is an issue.

Warranty Taptile and Taptile Controls are registered trademarks of GPEG International Ltd. Taptile Controls are fully CE compliant and accredited by Intertek Ltd. Our confidence in Taptile technology and product quality means that every Taptile Touch Sensor can have their 2 year standard warranty extended to 10 years by simply registering your products serial number on our web site within 30 days of purchase. Upon receiving your completed Warranty Registration, we will e mail you a warranty confirmation. During the period of the warranty, GPEG International Ltd will arrange for the Taptile Touch Sensor to be repaired or (at our discretion) replaced free of charge. If the Taptile Sensor fails due to damage caused during installation, this Warranty does not apply. GPEG International Ltd shall in no event be liable for incidental or consequential damages, including, but not limited to extra utility expenses or damages to property and interiors. All external Taptile items such as the power adaptor and wireless receivers, come with a 2 year warranty from date of purchase, except as provided below. The cost of repair or replacement of the product is your only remedy under this Warranty which does not affect your statutory rights. Such cost does not extend to any cost other than the direct cost of repair or replacement by GPEG and does not extend to the costs associated with retiling, rewiring, plastering or any other remedial work. GPEG International Ltd is not responsible for Damage or repairs required as a consequence of faulty installation or application Damage as a result of floods, fires, winds, lightning, accidents, corrosive environment or other conditions beyond the control of GPEG Use of components, fittings or accessories not compatible with the Taptile Sensor Products installed outside the United Kingdom Normal maintenance as described in the installation and operating manual Parts not supplied or designated by GPEG Damage or repairs required as a result of any improper use, maintenance, operation or servicing Failure to start due to interruption and/or inadequate electrical service Changes in the appearance of the product that does not affect its performance Damage caused through lack of protection by an RCD at all times