Room air quality sensors

Similar documents
Room Air Quality Sensors

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

Duct Air Quality Sensors

QPM21 Series Duct CO 2 and Air Quality Sensors

Room Temperature Sensors

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Duct Temperature Sensors

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

for relative humidity and temperature with calibration certificates

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

QFM21... Duct sensors. Symaro. for relative humidity and temperature

for relative humidity and temperature

for relative humidity and temperature

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

Indoor Air Quality Controller

Room Temperature Sensor

Room Temperature Controller

Semi flush-mount room thermostat

Room Temperature Sensors

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Room thermostats with LCD for wall mounting

Room Temperature Controller

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Room Temperature Controller with LCD

Duct Temperature Sensors

RDH10. Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Preliminary Release. Room Temperature

Room Temperature Controllers

Flush-mounted room thermostat

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

PRELIMINARY EDITION

Room Temperature Controller

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Use. For 2-pipe fan coils

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Differential pressure sensors

No. Icon Name Function

WRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet

Flush-mounted room thermostats

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

WRF04 CO 2 RS485 Modbus

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

Wall-mounted room thermostat with LCD

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

The fan is switched to the selected speed via control output Q1, Q2 or Q3.

Wireless room thermostat with LCD

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Self-learning Room Temperature Controller

Danfoss gas detection units

Room thermostat with Auto Timer, Option External Input

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Immersion Temperature Controller

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Room thermostat with 24-hour time switch and large LCD

RVL479. Heating Controller. for use with a partner unit

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

SIMRAD GD10PE IR GAS DETECTOR

RVP310. Heating Controller. Building Technologies HVAC Products

Flame Safeguards LFE10. Building Technologies HVAC Products

RVL480. Heating Controller

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

RVL481. Heating Controller. including d.h.w. heating

Indoor Air Quality Controller

SIMRAD GD10 IR GAS DETECTOR

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Room Unit. Building Technologies SYNERGYR

Self-learning Room Temperature Controller

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

Semi flush-mount room thermostats

UV Flame Supervision System

Application guide RDG160 Remote control

Self-learning Room Temperature Controller

Room thermostat with Auto Timer, Option External Input

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Self-learning Room Temperature Controller

RVL470. Heating Controller. Use. Functions. Series B

LC1350 Level Controller

Room thermostats with LCD RDD100..

Flame Safeguards LFE10. Building Technologies HVAC Products

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

Room thermostat with Auto Timer, Option External Input

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

MANDÍK MEASUREMENT AND CONTROL SYSTEM

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Multifunction IAQ Monitor

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Transcription:

1 961 1961P01 QPA20 QPA20 D 1961P02 Room air quality sensors QPA20 Use With maintenance-free CO 2 sensing element based on optical infrared absorption measurement (NDIR 1) ) and depending on the type of sensor VOC 2) sensing element based on a heated tin dioxide semiconductor CO 2 temperature and CO 2 humidity-temperature multi-sensor No recalibrations required Operating voltage AC 24 V or DC 15 3 Signal outputs DC 0...1 1) NDIR = Non dispersive infrared 2) VOC = volatile organic compounds (also called mixed gas) In ventilation and air conditioning plants to enhance room comfort and optimize energy consumption by providing demand-controlled ventilation. The sensor acquires: CO 2 concentrations as an indication of occupancy in rooms where smoking is prohibited VOC concentrations as an indication of odors such as tobacco smoke, body odor, or material fumes in the room Relative humidity in the room Room temperature The QPA20 can be used as a: Control sensor Transmitter for building automation and control systems and / or display units Typical use: Acquisition of CO 2 and VOC concentrations: In party rooms, lounges, fair pavilions and exhibition halls, restaurants, canteens, shopping malls, athletic centers, sales rooms, and conference rooms Acquisition of CO 2 concentrations: In rooms with varying occupancy levels where smoking is prohibited, e.g. museums, theaters, movie theaters, auditoriums, office spaces, and school rooms CE1N1961en 22.08.2008 Building Technologies

Important! QPA20 sensors may not be deployed as safety devices, e.g. as gas or smoke warning devices! Type summary Product number CO 2 measuring range VOC sensitivity Temperature measuring range Humidity measuring range Display of measured value QPA2000 0 2000 ppm --- --- --- No QPA2002 0 2000 ppm Low (R1) Normal (R2) High (R3) QPA2002D 0 2000 ppm Low (R1) Normal (R2) High (R3) --- --- No --- --- Yes QPA2060 0 2000 ppm --- 0...50 C / 35...+35 C --- No QPA2060D 0 2000 ppm --- 0...50 C / 35...+35 C --- Yes QPA2062 0 2000 ppm --- 0...50 C / 35...+35 C 0...100 % No QPA2062D 0 2000 ppm --- 0...50 C / 35...+35 C 0...100 % Yes Ordering Equipment combinations Mode of operation When ordering, please give name and product number, e.g.: Room air quality sensor QPA2002 QPA20 sensors are designed for deployment with all types of systems and devices capable of acquiring and handling the DC 0...1 output signal from the sensor. CO 2 concentrations Function diagram CO 2 (output U1) CO 2 /VOC concentration only with QPA2002 and QPA2002D Symaro TM air quality sensors acquire the CO 2 concentration by infrared absorption measurement (NDIR). Due to an additional integrated reference light source, the measurement is always accurate and no service or recalibration needed, thus reducing service costs. The resulting output signal DC 0...1 is proportional to the CO 2 content of ambient air. 10 8 6 4 2 0 U1 [V] 0 400 800 1200 1600 2000 1961D01 CO 2 [ppm] The sensor acquires and evaluates the CO 2 / VOC concentration and transforms it to a ventilation demand signal. It represents the result of maximum selection of the CO 2 measuring signal and the filtered VOC measuring signal. With maximum selection, the 2 demand signals are compared and depending on the result and the selected VOC sensitivity provided as common air quality demand. The ventilation demand signal is provided via output U2 as a DC 0 1 signal to be supplied to the ventilation controller. 2/8

Ventilation demand diagram (output U2) U2 [V] Max (CO, VOC) 2 [ppm] VOC sensitivity Response time "VOC signal" Relative humidity only with QPA2062 and QPA2062D Temperature only with QPA206 Using the shorting plug on the setting element for the measuring range allows for changing the impact of VOC ventilation demand on maximum selection against CO 2 ventilation demand. The position in the center (R2) produces normal sensitivity of the VOC signal (factory setting). The 2 other positions are used to increase (R3) or decrease (R1) VOC sensitivity. Before the processor handles a change of the measured VOC value for maximum selection, a response time of 3 minutes for every Volt the signal value changes is observed. The sensor acquires the relative humidity in the room with a capacitive humidity sensing element whose capacitance changes as a function of relative humidity. An electronic measuring circuit converts the signal from the sensing element to a continuous DC 0...1 signal, corresponding to a relative humidity range of 0...100 %. The sensor acquires the room temperature with a sensing element whose electrical resistance changes as a function of the temperature. The change is converted to an active DC 0...1 output signal ( 0...50 C or 35...+35 C). Mechanical design The units are designed for wall mounting and can be deployed with most types of commercially available recessed conduit boxes. The cables can be introduced from the rear (concealed wiring), from below or above (surface-run wires) through knockout openings. The units consist of 2 major sections: Casing and baseplate. Both snap together but can be again detached. The measuring circuit, the sensing elements, and the setting elements are located on a printed circuit board in the unit. The mounting base carries the connection terminals. 3/8

Setting elements R1 R2 R3 X4 Test function active X4 U1 U2 1 F C X4 R1 R2 R3 X4 Display Temperature unit F 1 QPA2000/2002/2060 QPA2002D/2060D C 1961Z04en X4 R1 R2 X4 R3 * Test function active X4 U1 U2 U3 1 F C X17 R1 R2 R3 Display Temperature unit 1 F QPA2062 QPA2062D C * Set either X4 or X17 into test function, but not both at the same time. X17 U1 U2 U3 1 The setting elements can be accessed after removing the mounting base. for the measuring range with QPA2000 Meaning of the different shorting plug positions: For the CO 2 measuring range: Shorting plug in the mid position (R2) = 0 2000 ppm (factory setting) with QPA2002 and QPA2002D with QPA206 For CO 2 / VOC weighting: Shorting plug in the upper position (R1) = VOC sensitivity "low" Shorting plug in the mid position (R2) = VOC sensitivity "normal" (factory setting) Shorting plug in the lower position (R3) = VOC sensitivity "high" For the temperature measuring range: 4/8

Shorting plug in the upper position (R1) = 35...+35 C Shorting plug in the mid position (R2) = 0...50 C (factory setting) for the active test function for changeover of the temperature display Behavior in the event of fault All types QPA2002 QPA2060 and QPA2060D QPA2062 and QPA2062D Display of measured values Disposal Shorting plug for the measuring range in the vertical position: The signal output delivers the values according to table "Test function active". Meaning of the different shorting plug positions: For the unit of temperature: Shorting plug in the horizontal, lower position = C (factory setting) Shorting plug in the horizontal, upper position = F In the event of CO 2 failure, 1 is present at signal output U1 (after 60 seconds) In the event of CO 2 or VOC failure, 1 is present at signal output U2 (after 60 seconds) If the temperature sensor becomes faulty, is present at signal output U2 If the temperature sensor becomes faulty, is present at signal output U3, and the humidity signal at signal output U2 increases to 1 (after 60 seconds) If the humidity sensor becomes faulty, 1 is present at signal output U2 (after 60 seconds), and the temperature signal remains active With sensors type QPA2002D, QPA2060D and QPA2062D, the measured values can be read on an LCD. The following measured values are displayed: CO 2 : In ppm CO 2 + VOC: As a bar chart (4 bars U2 = 2 V, 20 bars U2 = 1) Temperature: In C or F Humidity: In % The major plastic components are labeled with material references in compliance with ISO / DIS 11 469 to allow for environmentally compatible disposal. Engineering notes Cable routing and cable selection The sensor must be powered by a transformer for safety extra low-voltage (SELV) with separate windings, suited for 100 % duty. Size and fuse it in compliance with local safety regulations. When sizing the transformer, consider the power consumption of the sensor. For information about wiring, see the data sheets of the devices with which the sensor is used. Observe maximum permissible cable lengths. When laying the cables, remember that electrical interference is greater the longer the cables run parallel and the smaller the distance between them. On applications with EMC problems, use shielded cables. For secondary power lines and signal lines, use twisted-pair cables. Mounting notes Mounting location Mounting instructions Inner wall of the room to be ventilated, not in niches, not behind curtains, not above or near heat sources, and not exposed to direct light from spot lights. Do not expose the sensor to direct solar radiation. Seal the end of the conduit at the sensor to prevent false measurements due to drafts through the conduit. Mounting instructions are enclosed in the package. 5/8

Commissioning notes The sensor s functions can be checked 30 minutes after applying power: Checking the CO 2 function: In well ventilated rooms, the sensor shows the CO 2 concentration of the outside air. This is typically, 360 ppm (the sensor s measuring accuracy must be considered). Also, a basic functional check can be made by exhaling on the sensor. In this case, remember that the sensor s rate of response is purposely delayed (time constant t 90 = 5 min) Checking the VOC function: Touch the sensor with a cotton ball dowsed in alcohol (e.g. gas from a cigarette lighter, without lighting a flame) Ventilation should start when the preset switching level of the connected controller is reached. After applying power to the types of sensor with display, Init appears for about 6 seconds. Technical data Power supply Cable lengths for measuring signal Functional data "CO 2 " Functional data "Maximum selection of CO 2 and VOC" with QPA2002 and QPA2002D Functional data "r.h." with QPA2062 and QPA2062D Functional data "Temperature" with QPA206 Display of measured value Protective data Electrical connections Environmental conditions Operating voltage (SELV) Frequency Power consumption Perm. cable lengths (MW = measured value) Measuring accuracy at 23 C and 1013 hpa Temperature dependency in the range of -5 45 C Long-time drift Time constant t 90 AC 24 V ± 20 % or DC 15 3 50 / 60 Hz at AC 24 V 2 VA See data sheet of the device handling the signal 0...2000 ppm ±(50 ppm + 2 % MW) ± 2 ppm / C typically ±20 ppm p.a. <5 min Output signal, linear (terminal U1) DC 0...1 0...2000 ppm, max. ± 1 ma Recalibration-free 8 years 0...2000 ppm VOC sensitivity See "Type summary" Output signal, linear (terminal U2) DC 0...1 0...2000 ppm, max. ± 1 ma Response time "VOC signal" t VOC Range of use Measuring accuracy at 23 C and AC 24 V 0 95 % r.h. 30 70 % r.h. Temperature dependency Time constant 3 min / V 0...95 % r.h. (non-condensing) 0 100 % r.h. ± 5 % r.h. ± 3 % r.h. (typically) 0.1 % r.h. / C approx. 20 s Output signal, linear (terminal U2) DC 0...1 0...100 % r.h., max. ± 1 ma Measuring element Measuring accuracy at AC 24 V in the range of 15...35 C 35...+50 C Time constant t 63 0...50 C (R2, R3) or 35...+ 35 C (R1) NTC 10 kω ± 0.8 K ± 1 K 8.5 min Output signal, linear (terminal U2 or U3) DC 0...1 0...50 C / 35...+ 35 C Max. ± 1 ma With QPA2002D, QPA2060D, QPA2062D LCD Degree of protection of housing IP 30 to IEC 60 529 Safety class III to EN 60 730 Screw terminals for 1 2.5 mm 2 or 2 1.5 mm 2 Operation to Climatic conditions Temperature (housing incl. electronics) Humidity Mechanical conditions IEC 60 721-3-3 Class 3K3 0...50 C 0 95 % r.h. (non-condensing) class 3M2 6/8

Materials and colors Standards Weight Transport to Climatic conditions Temperature Humidity Mechanical conditions Cover Housing Mounting plate Sensor (complete) Packaging Product safety Automatic electrical controls for household and similar use EN 60 730-1 Electromagnetic compatibility Immunity QPA2062, QPA2062D Immunity QPA2000, QPA2002, QPA2002D, QPA2060D, QPA2060D Emissions conformity to conformity to Australian EMC Framework Radio Interference Emission Standard conformity UL 916 Incl. packaging Without display With display IEC 60 721-3-2 Class 2K3 25...+ 70 C < 95 % r.h. Class 2M2 ASA + PC, NCS S 0502- (white) ASA + PC, NCS 2801-Y43R (gray) PC, NCS 2801-Y43R (gray) Silicone-free Corrugated cardboard EN 61 000-6-1 EN 61 000-6-2 EN 61 000-6-3 EMC directive 2004/108/EC Radio Communication Act 1992 AS / NZS 3548 approx. 0.10 kg approx. 0.12 kg ppm = parts per million (number of parts per one million parts) Room sensors with active outputs have power dissipation influencing temperature measurement. The degree of influence depends on the operating voltage and is compensated at AC 24 V operating voltage in Symaro TM room sensors. All other operating voltages may result in over- or undercompensation. Furthermore, the measuring accuracy is influenced by the following: - Prevailing air flow - Wall surface (rough, smooth) - Type of wall (wood, plaster, concrete, brick) - Location of wall (inside, outdoors). In an installed sensor, the application-specific measuring accuracy becomes constant after about a 1-hour operating time. It can be adjusted by a higher system (e.g. controller) as needed. 7/8

Connection terminals QPA2000 QPA2002, QPA2002D 0 CO 2 CO 2 CO 2 / VOC U1 0 U1 U2 196101 196102 QPA2060, QPA2060D QPA2062, QPA2062D R1 = -35...+35 C / CO 2 R2 = 0...50 C CO 2 r.h. 0 U1 U2 0 U1 U2 196103 R1 = -35...+35 C / R2 = 0...50 C U3 196104 0 U1 U2 U3 System potential AC 24 V (SELV) or DC 15...3 System neutral and measuring neutral Signal output DC 0...1 Signal output DC 0...1 Signal output DC 0...1 Dimensions (in mm) 4,2 9,5 100 56 60 90 36 56 60 1961M01 Drilling plan 8/8 2005-2008 Siemens Switzerland Ltd. Subject to change