DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Similar documents
HOTLINE:

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

WHHR Midi & Midi Lite

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Installation and Maintenance

Installation and Maintenance

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

Installation and Maintenance

Thank you for choosing EnviroVent

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Installation and Maintenance

Xcell 270 Longlife DC wholehouse heat recovery unit

Installation and Maintenance

Installation and Maintenance

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

Installation and Maintenance

MODEL: BV400 Part No:

VENTILATION. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions. Models: HRX2-S, HRX2-B, HRX2-FP, HRX2-BFP

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

HR200WK Through the wall Heat Recovery Ventilator

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Lo-Carbon Quadra SELV

60cm Integrated Turbo Extractor

Lo-Carbon SELV Tempra

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

HOTLINE:

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Centrif Duo & Centrif Duo Plus

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Lo-Carbon Quadra Centrifugal Fan

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

Lo-Carbon T-series Window & Roof Models

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

November This product has been reconfigured Please read these instructions

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

KUDOS. Instruction leaflet

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Lo-Carbon Quadra Centrifugal Fan

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

GUH90 90 cm Canopy Hood

Sentinel. Kinetic MVHR Range. Installation & Commissioning. Stock Ref. N PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Installation & Operating Instructions

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts.

BWT6.3GL Cooker Hood 60 cm Glass chimney hood

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

Lo-Carbon Sentinel Kinetic Horizontal

Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide

60cm Chimney Extractor

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Stainless Steel Chimney Extractor

Stainless Steel Chimney Extractor

air pump 2700/4500 ? 2YEAR GUARANTEE UK AIRPUMP _33435 CASC /10/ :16 Page 1

irconcentre.co.uk airooncentre.co.uk

EVG Extractors. Manual for Installation, Use and Maintenance

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

NTD-125-*, NTD-204-* & NTD-220-* Nuaire Round & Rectangular Thermal Ducting Installation Guide

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

EDD61 & EDD91 Extractors

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

AP-EH500-L/RQA9837. Installation Guide

Transcription:

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit Stock Ref. N DC Heat Recovery Unit MVHR 443423 Installation, Maintenance & Users Instructions PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Index Page No 1. GENERAL 3 2. PRODUCT DESCRIPTION 4 3. TECHNICAL SPECIFICATIONS 5 4. FITTING THE UNIT IN BRIEF 5 5. INSTALLATION DIAGRAM 6 6. CONNECTING THE CONDENSATE DRAIN 7-8 7. INSTALLATION 9 7.1 MOUNTING THE UNIT 9 7.2 CONNECTING THE DUCTWORK 9 8. ELECTRICAL CONNECTIONS 10 8.1 WIRING DIAGRAM 10 9. USER MAINTENANCE 11 9.1 CLEANING THE FILTERS 11 9.2 CLEANING THE HEAT EXCHANGER 12 10. SPARES 13 INSTALLATION CHECKLIST 14 2

DC HEAT RECOVERY UNIT MVHR INSTALLATION AND MAINTENANCE INSTRUCTIONS Read the following instructions in conjunction with the illustrations before commencing installation. 1.GENERAL IMPORTANT POINTS TO NOTE 1. THIS APPLIANCE IS INTENDED FOR PERMANENT CONNECTION TO THE MAINS ELECTRICAL SUPPLY FIXED WIRING AND MUST BE INSTALLED BY A SUITABLY QUALIFIED PERSON. 2. THIS APPLIANCE MUST BE SITED AND CONNECTED IN ACCORDANCE WITH CURRENT UK BUILDING, FACTORY AND IEE WIRING REGULATIONS (BS7671) OR THE APPROPRIATE NATIONAL REGULATIONS IN YOUR COUNTRY. 3. WIRING TO THE APPLIANCE IN THE UK MUST BE VIA A FUSED AND SWITCHED CONNECTION UNIT INCORPORATING A DOUBLE POLE SWITCH WITH 3mm CONTACT SEPARATION AND CONFORMING TO BS5733 OR BS1363 PART 4. A 3 AMP BS1362 FUSE SHOULD BE FITTED TO THE CONNECTION UNIT, WHICH MUST BE LOCATED OUTSIDE OF A ROOM CONTAINING A FIXED BATH OR SHOWER. 4. WARNING: THIS APPLIANCE IS CLASS I AND IT MUST THEREFORE BE EARTHED. 5. CHECK THE RATING LABEL ON THE APPLIANCE TO ENSURE THAT THE ELECTRICAL SUPPLY IS COMPATIBLE WITH THE APPLIANCE WHICH IS RATED AT 220-240V 50 Hz AC. 6. THIS APPLIANCE MUST BE SITED OUT OF REACH OF ANY PERSON USING A FIXED BATH OR SHOWER. 7. THE UNIT S CONDENSATE DRAIN MUST BE CONNECTED TO THE BUILDING WASTE WATER DRAINAGE SYSTEM. 8. THIS APPLIANCE MUST BE SITED AWAY FROM DIRECT SOURCES OF HEAT IN EXCESS OF 40 DEGREES C. 9. UNIT MUST BE SITED IN A FROST FREE LOCATION. 10. SITE THE APPLIANCE AND ARRANGE THE ASSOCIATED DUCTING AND GRILLES TO PROVIDE A BALANCED CIRCULATION OF AIR. 11. THE EXTERNAL INTAKE TERMINALS ASSOCIATED WITH THIS APPLIANCE MUST BE SITED AT LEAST 600mm AWAY FROM THE FLUE OF A FUEL BURNING APPLIANCE/ OTHER EXTERNAL GRILLE. 12. ALL SAFETY REGULATIONS AND REQUIREMENTS MUST BE STRICTLY FOLLOWED TO PREVENT HAZARDS TO LIFE AND PROPERTY BOTH DURING AND AFTER INSTALLATION AND DURING ANY SUBSEQUENT MAINTENANCE AND SERVICING. 13. SWITCH OFF THE MAINS ELECTRICAL SUPPLY BEFORE COMMENCING INSTALLATION, MAINTENANCE OR SERVICING. 14. IF THE DUCTWORK PASSES THROUGH AN UNHEATED LOFT VOID OR SIMILAR LOCATION, IT MUST BE INSULATED. 15. CERTAIN APPLICATIONS MAY REQUIRE THE INSTALLATION OF SOUND ATTENUATION TO ACHIEVE THE SOUND LEVELS REQUIRED. 16. THIS APPLIANCE IS NOT INTENDED FOR USE BY YOUNG CHILDREN OR INFIRM PERSONS WITHOUT SUPERVISION. 17. YOUNG CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE. DO NOT switch off the unit except for servicing & maintenance - it is designed to run continuously. If the unit is switched off, indoor pollutants and moisture levels may increase and become a danger to your health and damage your home. It is important to follow the advice in this user manual and correctly maintain the system to ensure a healthy indoor environment. Disposal This product should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority for recycling advice. 3

2. PRODUCT DESCRIPTION The DC Heat Recovery MVHR unit is a mechanical ventilation/heat recovery (MVHR) unit for domestic and commercial applications. It is designed for connection to 125mm-diameter ducting. The unit s two fans and heat exchanger arrangement simultaneously supply and extract air while transferring heat from the stale exhaust airflow to the fresh intake airflow. This provides up to 91% heat recovery from the stale extracted air. Separation of the exhaust airflow and intake airflow is maintained throughout the unit. The fan motors have maintenance free, self lubricating long life bearings and are fitted with thermal overload protection, which in the event of a fault causing a motor to overheat will cut off the electrical supply to that motor. If this occurs, isolate the unit, check for any obstructions, leave the unit for a short time for the motor to cool before reconnecting the power supply. If the fault reoccurs, isolate the power supply and call a service engineer. The fans in this unit are low energy EC motors with a constant (100% adjustable) air volume. The EU3 filters in the unit ensure that the fresh supply air is clean as it enters the home. Also the extract air from the property is filtered to protect the heat exchanger from unwanted contamination. Check filters regularly and clean if necessary. The unit is delivered complete with a mounting plate, fitting instructions, fixing kit and a condensation discharge fitting. Left Hand configuration shown From atmosphere Extract from dwelling To atmosphere Supply to dwelling Condensate exit on Atmosphere side (See connecting the condensate drain section). Filters Filter access covers Front Panel 4

3. Technical specifications Maximum flow (Free Discharge) Low and Medium flow and optional sensor inputs 280 m 3 /h (78 l/sec) 0-100% adjustable on each speed. Set on installation Dimensions (w x h x d) [mm] 560 x 635 x 260 Spigot diameter [mm] Ø125 External diameter condensate discharge [mm] 22 Filter class Weight Supply voltage [V~/Hz] Power (Watts) Protection degree EU3 14 kg 230 / 50Hz / 1Ph Maximum 150W IPX2 Thermal efficiency up to % 91% 4. Fitting the DC MVHR unit in brief Please ensure that you read each section of this leaflet carefully. This section is just a brief overview of each installation stage. 1. Dismantle the DC MVHR unit in accordance with the diagram and text on page 6. 2. Mounting plate: Mounted by means of stand off feet, screws and plugs supplied, vertically or horizontally. Use the drilling template on the side of the box to locate the hole positions, ensuring that there is enough space around the unit so that the duct work and the condensation drain can be fitted (see pages 7 & 8 for details of which side of the unit the condensate drain should be fitted). 3. Reassemble the DC MVHR unit in accordance with the diagram and text on page 6. 4. When the HR unit has been installed, the ducting can be completed. Remember that both ducts to and from the outside will be fitted to one side of the unit and the ducts to and from the home are attached to the other side of the unit refer to (page 9). 5. When the duct runs are completed, and an appropriate electrical supply is present see page 10 for wiring details, the installation can be completed. For further information about the operation, adjustment and maintenance of the unit, read the following pages carefully. 5

5. Installation diagram OUTLET/INLET SPIGOTS INTERCONNECTING STUDS (Unscrew) COVER FIXING SCREWS & PLUGS METAL BACKPLATE MOTOR ASSEMBLY CELL 1. Pull the front cover off the four Velcro fixings. 2. Place the unit flat on the floor and unscrew and keep the four stud retaining screws. 3. Without damaging the rubber seal carefully separate the moulded top half of the unit from the bottom half by pulling the casing straight forward. 4. Unscrew the four forward protruding studs and keep in a safe place. 5. Stand unit upright to separate the metal wall mounting plate from the bottom half of the casing. Pull the casing forward leaving the rear protruding studs attached to the metal backplate. 6. Secure the metal base plate with the rear studs still attached to the wall 7. Re-assembly of the unit to the wall mounted backplate with the protruding studs is the reverse of the removal procedure 6

6. Connecting condensation drain The condensation drain must be mounted at the bottom of the HR heat recovery unit with the fitting supplied. Use a 20mm hole saw to cut the hole, take care to cut on the correct side of the unit according to left or right handed configuration. Use silicon sealant to seal the condensation fitting to the HR unit. The drain must discharge into the household drainage system and must be insulated. Follow the steps below:- 1. Lay the unit on a flat level surface [1] and carefully slide the heat recovery cell out from the housing [2] put the cell to one side. 2. Determine what side you want the condensate drain to be (see page 8 for left and right hand positioning), if mounting the unit vertically the condensate hole needs to be in position shown at its lowest point to allow the condensate to run out [3] (image shown for right hand installation). 3. If mounting the unit horizontally then position the condensate hole in position shown [4] (image shown for right hand installation). 4. Use a 20mm hole saw to cut-out the correct bung, Clean away any debris from drilling the hole. 5. Screw the condensation fitting as shown [5] and silicone seal to create a water tight seal. 6. Connect up to the household drainage system. 7. Ensure that the drain incorporates a U-bend to prevent air penetration. 8. Ensure that the distance between the unit and the U-bend is adequate for de-mounting and cleaning if required. 9. Condensate drain supplied:- 22mm standard PVC [1] [2] [3] [4] [5] 7

Drain position when mounting the unit vertically. OUTSIDE INSIDE THE HOME OUTSIDE LEFT HAND RIGHT HAND Drain position when mounting the unit horizontally. TO ATMOSPHERE FROM ATMOSHERE EXTRACT FROM DWELLING SUPPLY TO DWELLING SUPPLY TO DWELLING EXTRACT FROM DWELLING FROM ATMOSHERE TO ATMOSPHERE TO ATMOSPHERE FROM ATMOSHERE EXTRACT FROM DWELLING SUPPLY TO DWELLING SUPPLY TO DWELLING EXTRACT FROM DWELLING FROM ATMOSHERE TO ATMOSPHERE OUTSIDE INSIDE THE HOME OUTSIDE LEFT HAND RIGHT HAND IMPORTANT:- FOR HORIZONTAL MOUNTING ENSURE 4 SLOPE DOWNWARDS TOWARDS CONDENSATE DRAIN POSITION 8

7. Installation 7.1 Mounting the DC MVHR unit The mounting plate of the DC MVHR unit can be fitted directly to the wall or joists with the supplied screws, plugs and stand off feet. For wall fitting use the template on the side of the box supplied. Ensure that there is enough space for the condensation fitting and ducts to be connected. The position of the electrical power supply (a fused switched isolator) must not be mounted above or closer than 1m to a cooker where it could be affected by excessive heat or moisture. The unit is designed to be mounted in a kitchen cupboard / on the wall, or horizontally in a loft/void. Make sure there is enough free space at the front of the appliance for accessing/cleaning the filters and carrying out maintenance on the appliance. Important Note:- When fitting on its back make sure that a minimum of 4 downwards slope towards the condensate drain is maintained to ensure proper drainage of condensation. 7.2 Connecting ducts When the DC MVHR heat recovery unit has been installed the ducts can be fitted. The ducts to and from the home are on one side of the unit. The ducts to and from outside are on the opposite side. In order to prevent condensation on the outside of the exterior air intake duct and the air exhaust duct, both ducts must be insulated. We recommend that rigid ducting is used to within 150mm of the appliance. The last connection to the unit maybe made in flexible ducting. If flexible ducting is used it should be fully extended with no drooping over joists but without placing any strain on the terminal or fixings. We recommend a minimum distance of 200mm between the appliance and any sharp bends in the duct work, To ensure that the noise levels are kept to a minimum. Connection example DC MVHR heat recovery unit. B A = Min 1 Metre (optimum 2 metres) Between intake & exhaust terminals. B = Intake duct from roof C = Exhaust duct from roof D = DC MVHR unit E = Ducts from and to the house F = Condensation drain A C Fig.2. E D F 9

8 Electrical connections The appliance must be earthed. All wiring must conform to B.S 7671:IEE wiring regulations. And be completed by a qualified electrician. This appliance is suitable for 230v ~ 50Hz single phase supply fused at 3 amps. The appliance is supplied with a mains flexible cable (PVC sheathed, 6-core 0.75mm²). A double pole switch having a minimum contact separation of 3.0mm must be used to provide isolation for the unit. Switch Positions Function Trickle (Low) (R1) 100% adjustable Medium (R2) 100% adjustable Purge (High) (R3) 100% adjustable Remote Switch Positions (R4) 100% adjustable (R5) 100% adjustable Upon installation the fan should be started in High speed mode to ensure optimum performance of the fans and switched to the required continuous ventilation setting. The fan speed controller must not be mounted above or closer then 1m to a cooker where it could be affected by excessive heat or moisture. 8.1 Wiring Diagram A five speed control switch (3 x manual, 2 x external sensors) is supplied. Each fan speed must be adjusted to suit dwelling on installation (R1/R2/R3). Any optional external sensors, i.e.: CO2, Humidity, Timer/Clock, Motion/PIR must also be adjusted when connected (R4, R5). Important all the external sensors must have volt free contacts. Suggested set points are shown for general purpose ventilation (trickle, medium, purge) which enable manual boost for purge (maximum) ventilation and/or override of external sensors when fitted. 10

9. User Maintenance User maintenance is limited to periodically cleaning the filters and the heat recovery cube. The unit should not be used without filters. Cleaning intervals can be extended in areas of relatively low air pollution levels. The filters should be replaced annually or after a maximum of 3 cleaning cycles 9.1 Cleaning the filters by user Switch off the power supply Remove front panel Carefully remove filter covers Carefully remove the 2 filters Gently vacuum the outside of the filters as shown After cleaning replace the filters Replace filter covers Replace front panel Switch power back on and check unit is operating normally 11

9. User Maintenance 9.2 Cleaning the heat exchanger by user 1. Switch off the power supply & remove the front panel 2. Unscrew the 4 screws on the front of the unit. Carefully remove the front half of the unit and put to one side. 3. Carefully remove the heat exchanger. Clean the heat exchanger with warm soapy water, use a suitable sterilising agent to sterilise. Allow to dry fully before proceeding. 4. Reassemble the unit taking care not to damage the rubber seals 12

10. Spares 5 3 6 2 4 1 ITEM PART NUMBER DESCRIPTION 1 444364 FRONT COVER (WHITE) 2 444363 FILTER COVER (SET OF 2) 3 443889 FILTERS (PACK OF 2) 4 444362 HEAT RECOVERY CELL 5 444374 E.C FANS 6 444360 CONDENSATION DRAIN 13

MVHR Installation Checklist REQUIRED TO BE COMPLETE TO COMPLY WITH CONDITIONS OF WARRANTY, but does not affect statutory rights. This is a short check list of good practice do s and don ts that may affect the safety or functionality of the installation. It is not a complete list of what is required. They must be complied with in order to ensure that the installation performs as expected. Unit Serial number: Installer s name: Check Date and initials 1. Is the unit stable and horizontal with room around it to allow maintenance? 2. Is any flexible ducting pulled taut to prevent moisture collection and avoids airflow issues? 3. Is any flexible ducting crushed which will cause airflow issues? 4. Are all joints in the ductwork sealed to prevent air leakage? 5. Is the ducting insulated to prevent condensation and cooling or heating of the air? 6. Does the condensate drain a) have the correct slope to ensure water runs away and b) is fitted with a trap to prevent smells coming back into unit? 7. If the condensate drain passes through a cold space is it insulated to prevent freezing? See the Installation Guide and Checklist at: http://www.sap-appendixq.org.uk/documents/mvhr_installation_guide_final.pdf 442920 D 1012 14