TSEK VHR EC HEAT RECOVERY UNITS

Similar documents
HEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel:

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION HEAT RECOVERY UNITS VHR MODELS

KOMFORT EC DB Suspended heat recovery air handling units

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

INSTALLATION OPERATION & MAINTENANCE INSTRUCTION

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Heat Recovery Units. Heat Recovery Units

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

TEVHR. Heat Recovery Ventilators

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

TEVHR. Heat Recovery Ventilators

Heat and energy recovery ventilators

HEAT RECOVERY DEVICES

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

FOUR-HOME-CEILING Ceiling Type Residential Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

TEVHR. Heat Recovery Ventilator

The Sentinel Kinetic Horizontal Range

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Lo-Carbon Sentinel Kinetic Horizontal

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Series VENTS VUT R WH ЕС

Chiller units and air-water heat pumps RANGE OPERATING LIMITS

INSTALLATION OPERATION MAINTENANCE INSTRUCTION HEAT PUMP HEAT RECOVERY UNITS VHR MODELS

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

The new Xcell EC High Efficiency Range Fresh air pure and simple

AIR HANDLING UNITS ver B

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

FOUR-FHR Counter Flow Heat Recovery Unit. is a registered trademark of Doğu İklimlendirme A.Ş.

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Small Room Heat Recovery Ventilation

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

TopMaster Air Handling unit. Technical data

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

CONTENT: VEX308 Decentralised ventilation VEX308

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

AHU Plus. DX Air Handling Units

IGH FX / IGH FX EC. Heat Recovery Ventilation Unit

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

Auxiliary Equipment and Accessories

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

HRV Enthalpy. Catalogue

VENTILATION & HEATING CATALOGUE.

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

FLEXIT S4 X/TT - A4 X/TT S7 X/TT - A7 X/TT

ECONET PREMIUM FAQ TROUBLE-SHOOTING: GT 21 GT 20 GT 00 GF 10 GT 10. Start by checking all indata for the air handling unit.

Roof top SPACE RPC 450Z R407C M011

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

DAIKIN Air Handling Unit Modular

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

EHW KH PF HIGH EFFICIENTY AIR CONDITONING UNITS TECHNICAL CATALOGUE

Sentinel Demand Energy Recovery Ventilation

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Ventilation unit Zehnder ComfoAir 200

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Zehnder ComfoAir 550. Ventilation unit

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

MRXBOXAB-ECO3 MRXBOX-ECO3

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

TopMaster Air Handling unit. Installation instructions

MRXBOXAB-ECO2 MRXBOX-ECO2

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Heat Recovery Air Handling Units

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

HCompact2 HA. Compact air-air stand-alone units. Compact horizontal Reduced dimensions Centrifugal fans RANGE DESCRIPTION OPERATING LIMITS SERIES

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

New rooftop series UATYQ-ABAY1 AFC2Y1 AFC3Y1. Extensive option package included in all models. ErP. years warranty. compliant 2018

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

DOMEKT ReCU 400VE(W)CF-EC-C4 Series Air Handling Units Installation and Maintenance Service Manual

MODEL: BV400 Part No:

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Flexit air handling units C2 and UNI 2, 3,4

Transcription:

TSEK EC HEAT RECOVERY UNITS TS EN ISO 9001:2008 SN: 01 100 901925

General Information TSEK VENCO Heat Recovery Ventilation Units () are designed for saving energy and also improving indoor air quality. units provide the facilities of air-conditioning applications (residential, commercial and industrial areas) by using plate type exchangers, recovering heat from air to air. The heat is effectively transferred from warm to cold air by the exchangers with high conductivity, efficiency and performance. Excellent sound and heat isolation with fully insulated powder coated cabinet Electronic Controller Supplied with the unit as standard 7 standard models, with TSEK certification, CE marked and GOST-R certification in compliance with applicable directives, High efficient, direct driven EC Fans with low noise level, Proper ventilation with two 5-speed fans controlled separately, The compact design provides easy installation and maintenance, Aluminum plate type heat exchangers with high conductivity and performance. Energy recovery exchangers also available Indoor air quality with polyurethane filters,

Specifications SIMX MODEL 04 EC 07 EC 09 EC 11 EC 16 EC 29 EC 36 EC 51 EC Air Flow 0 Pa* l/s 126 200 235 324 454 660 860 1078 Air Flow 150 Pa* l/s 92 151 195 275 395 600 924 980 Heat Recovery Efficiency % Efficiency up to 70%, depending on working conditions Electrical Data 230 Volt / 50 Hz / 1~ W 2x85 2x85 2X170 2X170 2X450 2X500 2X740 2X750 Specific Fan Power SFP** SFP 1,01 1,01 1,29 1,09 1,73 1,4 1,53 1,36 Air Filter Polyurethane Filters for Fresh and Exhaust Air *External static pressure **According to EN 13779 at 150 Pa operating point SIMX MODEL 04 EC 07 EC 09 EC 11 EC 16 EC 29 EC 36 EC 51 EC Length (mm) L 800 900 900 940 1.115 1.585 1.635 1.700 Width (mm) W 740 860 860 1.020 1.030 1.030 1.150 1.210 Height (mm) H 295 335 335 450 430 435 680 700 Duct Connection (mm) Ø d 160 200 200 200 300 355 400 450 Weight (kg) 28 40 40 63 65 90 140 155 Other Dimensions (mm) W1 180 215 215 250 255 255 260 290 W2 195 225 225 270 265 265 250 270 W3 180 215 215 250 255 255 300 350 W4 195 225 225 270 265 265 245 270 Service Clearance (mm) LS 400 450 450 500 550 550 600 600

Air Flow - External Static Pressure

Electronic Control & Sensors FEC - Functional Electronic Controller FEC is supplied with Venco Heat Recovery Units as standard and it has the following features. Unit On/Off Control Adjusting Fresh Air Speed and Exhaust Air Speed Separately (5 Stages) It is possible to supply and exhaust the air depending on the request. Also positive or negative pressure can be obtained in the ventilation room. Control of Electrical Heater Manually or Automatically Venco Electrical Heaters can be controlled with FEC. Thus, there is no need another controller. It is possible to turn the heater On or Off and adjust stages manually. Also it can be controlled automatically depending on the set temperature. If heat recovery unit or its supply air fan is turned off, fresh air fan keeps working for 30 seconds to cool the heater. And FEC doesn t allow the electrical heater to run if fresh air fan of heat recovery unit isn t working. Control of Hot / Cold Water Coil Valve Manually or Automatically The 2-way valve or 3-way valve of the hot water coil can be controlled as On/Off by FEC. It is possible to open or close the valve of the water coil manually. Also it can be controlled automatically depending on the set temperature by FEC. Connectability to Building Management System (BMS) and VRV/VRF Systems FEC can turn the heat recovery unit on or off depending on the signal from BMS, VRV/VRF System or similar automation systems. And it can send a status signal of being On or Off to these applications. Timer Function It is possible to set the requested running hours of the heat recovery unit. Thus, heat recovery unit can run differently on the requested working days, Saturday and Sunday. By-pass Damper Control (Optional) Please look at the accessories page for more information about by-pass damper. Control of Air Quality (Optional) and Carbon Dioxide (Optional) Sensors It is possible to improve indoor air quality by using air quality or carbon dioxide sensors. The fan speed is adjusted automatically from the carbondioxide sensor or air quality sensor that could be connected to the unit. PIR Detector(optional) Heat Recovery Unit can run depending on the signal from the PIR detector that is connected to the unit by using FEC. Control with Modbus FEC can communicate with a BMS through Modbus Network. This allows the BMS to monitor the heat recovery unit and control all parameters of the unit. Warning for Clogged Filter (Optional) FEC gives warning when the filters are dirty. Frost Protection for Heat Exchanger (Optional) When the freezing temperature is detected, fresh air fan switches to minimum stage and exhaust air fan switches to maximum stage automatically. Electronic Controller Functional (FEC)

ACCESSORIES Duct Type Electrical Heater (VCE) VENCO electrical heaters have TSEK certification, CE marked and GOST-R certification. The technical specifications of products meet the essential requirements in the directives EMC 89/336/EEC and are tested according to the standards EN 55014-1, EN 61000-3-2/3-3 for EMC. Electrical heaters are produced in single phase or three phase upon request in standard spiral duct dimensions. The heaters have two overheating protections. VENCO electrical heaters are used with heat recovery units frequently. The electrical heaters can be used for two different purposes. It can be used when the outdoor temperature is low as a preheater to prevent freezing inside the heat exchanger It can be used as post heater to bring the fresh air temperature to the comfort conditions. The standard electrical heaters capacity and their specifications are at the following table. Electrical Heater VCE 04 VCE 07 VCE 09 VCE 11 VCE 16 v VCE 36 VCE 51 Capacity 1(0,5+0,5) KW 2(1+1) 3(1,5+1,5) 3(1,5+1,5) 4(2+2) 7(3,5+,3,5) 10(5+5) 12(6+6) Electrical Data 230 V / 1~ 400 V / 3~ Duct Type Water Coil (-) VENCO duct water coils are produced as hot water coil () or cold water coil () at standard capacities. High efficient heat transfer can be achieved with high performance heat exchangers. The design provides fast and easy installation and maintenance. Hot Water Coil 04 07 09 11 16 29 36 51 Heating Capacity 2,2 3,7 5,3 5,7 7,5 14,4 21,2 28,9 Pressure Drop Pa 9 21 20 22 22 25 25 25 Cold Water Coil 04 07 09 11 16 29 36 51 Heating Capacity 1,5 1,9 3,1 3,2 4,1 8,6 11,2 17,3 Pressure Drop Pa 23 38 36 40 40 45 45 44

By-Pass Connection Kit (BCK) VENCO Heat recovery units are used to transfer the heat from the exhaust air to supply air. In the transition seasons, it is much more suitable to supply the fresh air directly to indoor by not passing through the heat exchanger. By-pass connection kit allows controlling the outdoor air automatically and supplying the outdoor air directly to the indoor when it is necessary. Heat recovery units with BCK have the following heights and weights. By-Pass Kit Model BCK 04 BCK 07 BCK 09 BCK 11 BCK 16 BCK 20 BCK 23 BCK 29 BCK 36 BCK 51 Height* mm 340 400 400 475 520 520 520 520 700 920 Weight* kg 40 45 45 75 75 85 100 125 145 190 * Total values for the units with BCK

Distributed by: Simx Limited Ph: +64 9 259 1660 Technical Support Ph: +64 9 916 2099 Email: hvac@simx.co.nz www.simx.co.nz Simx reserves the right to alter technical specifications without prior warning