LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

Similar documents
TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

HIWARM kw. Air-water system with external and internal BLDC unit. Total heat recovery multi-purpose units HIWARM PLUS

LER kw. Indoor motor-driven evaporating units. Motor-driven evaporating units LER PLUS

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

HIWARM COMPACT kw

Motor-driven condensing units MTE MTE R-410A

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Galletti Water chillers and heat pumps catalogue

CRIMSON & CRIMSON MAX

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

LZA High efficiency air to water heat pumps with HP compressor

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

LZT High efficiency air to water heat pumps with E.V.I. compressors

Reversible Chillers and Heat Pumps - LEW SERIES kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

PRODUCT GUIDE

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

Modular Air-cooled Chillers

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

HYDRONIC RESIDENTIAL

Air Cooled Chillers & Heat Pumps WinPACK HE-A

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

TECHNICAL MANUAL MCP. Multipurpose - total heat recovery reversible heat pumps. 7 kw - 41 kw


CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Blue Box Epsilon Echos +

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

i-nrg 0061m 0061t Reversible heat pump with inverter compressor, total heat recovery, air source for indoor/outdoor installation 16,3 kw PRANA

Conditioning your ambient, maximising your comfort.

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Aquaflair TRAC-TRAF-TRAH

TECHNICAL MANUAL FOR CHILLERS AND HEAT PUMPS MPE

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

LZT High efficiency air to water heat pumps with E.V.I. compressors

Neosys Product catalogue

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

V-IPER. Installation, use and maintenance manual. Chillers and heat pumps 50 kw kw PLUS

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

RTA TECHNICAL MANUAL AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION O L S E A F RA N

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

pyxis u pyxis ua NEW rcgroupairconditioning

1

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

AQUASNAP JUNIOR 30RHV

WZH Ground source heat pumps

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

TECHNICAL MANUAL FOR CHILLERS AND HEAT PUMPS MPE D

black Thermal power (A7:W45) kw Cooling power (A35;W7) kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

york airside products Tailored air conditioning solutions Introducing the YORK YPRE range of custom air-to-air packaged roof top units

Aquaflair. Residential and Industrial Cooling Systems

PYXIS U PYXIS U. rcgroupairconditioning

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

pyxis pyxisa NEW rcgroupairconditioning

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

Water-cooled chillers with High Speed Centrifugal Compressors

HT V2 HT Split

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

kw COOLING kw HEATING

O L R E RGA ST RA N AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION TECHNICAL MANUAL

unico pf unico pf rcgroupairconditioning

Transcription:

Total heat recovery multi-purpose units LCP Outdoor monobloc air-water unit LCP - kw Heating, cooling, domestic hot water one single system to meet all kinds of needs. Total heat recovery multi-purpose unit PLUS Multi-purpose unit - -pipe system Multi-purpose unit - -pipe system Scroll compressor R-0A R-0A refrigerant Cooling / Heating Total heat recovery in two-pipe and four-pipe systems. High efficiency under part load conditions Production of chilled water up to an air temperature of C Smart Defrost System always able to guarantee continuity in operation. Built-in hydronic unit Access to the tax incentives provided for energy retrofitting Monobloc unit LCP multi-purpose units are air conditioning and domestic hot water (DHW) production units conceived for both residential and industrial use and designed to operate hours a day. They cover a wide range of heating capacities, from to kw, guaranteeing a high thermodynamic efficiency and broad configurability, both in terms of accessories and cooling circuits. All units of the LCP series, regardless of size, can be also made in a low-noise configuration L, in which the compressors and compressor compartment are covered with sound-deadening material and the unit is specially dimensioned so as to be compatible with a reduced fan speed. As for units with refrigerating capacity lower than 00 kw, LCP presents a solution with a double compressor divided into two independent thermodynamic circuits to always assure the unit operation. As for units with cooling power higher than 00 kw, compressors divided in two thermodynamic circuits are available in order to supply the unit power in four steps, perfectly adjusting it to the actual heat load of the system and to reduce inrush current. LCP units can be coupled with both - and -pipe systems, the letter P indicates heat pump for -pipe systems and the letter M indicates multifunctional heat pump for -pipe systems. In both versions, the machine uses the total heat recovery, when a request for contemporary production of cold water (cooling) and hot water (heating/dhw production) is needed. The unit recovers the condensation heat of the cooling system that would otherwise be ejected into the atmosphere. The total recovery LCP heat pumps have been designed for the cooling and the heating of the water destined to air-conditioning and domestic systems in residential, commercial or industrial buildings. 9 VM000-C

LCP - kw MAIN COMPONENTS Refrigerating circuits Heat exchanger Thanks to the presence of two independent thermodynamic circuits, the LCP M is capable of producing hot water for heating while simultaneously carrying out a defrost cycle or guaranteeing the replenishment of domestic hot water. Hydrophilic finned block heat exchangers are installed; these break down the drops of water into particles and reduce the obstruction of the space between one fin and another caused by ice build-up. Thanks to a lower surface tension, the water tends to slide and precipitate by gravity, preventing the formation of frost at low temperatures. Fans //-pole axial-type fans with airfoil-shaped blades made of hybrid plastic/aluminium material, statically and dynamically balanced in two planes, fitted with a protective grille and mounted with rubber vibration dampers placed in between. Option to select the condensation pressure-switch control with variation of the air-flow rate through electronic switching operated fans, to operate in cooling mode at low temperatures (up to - C) AVAILABLE VERSIONS LCP M - -pipe systems Cooling Compressors The scroll compressor today represents the best solution in terms of reliability and efficiency in the range of capacities up to 00 kw per circuit and the best solution in terms of sound power emitted. The use of scroll compressors makes it possible to use low-viscosity oils which, compared to solutions with oil at a high viscosity level, reduce thermal resistance at the evaporator with increases in the evaporation temperature of over. C (more than a.% gain in terms of EER) compared to alternative solutions. Electronic microprocessor controller LCP units are supplied with an Advanced microprocessor controller. In addition to the functions described below, this microprocessor offers the option of custom software features to ensure optimal satisfaction of all system requirements, including control of the unit with step-control or cascade logic. As regards remote communication options, the controls are configured for a connection to advanced BMS systems. Heating LCP P - -pipe systems Cooling Heating Total heat recovery multi-purpose units - LCP C C C C DHW production Cooling + DHW Cooling + Heating C C C C C Operating modes available for an LCP M unit which interfaces with a -pipe system. C Hydraulic circuit manages winter heating and summer air-conditioning while the C one is used for the production of DHW, ensuring this function days per year. In case of simultaneous production of cold (C) and high-temperature water for domestic use (C), the machine is able to recover all the condensation heat on the refrigerant for the production of DHW. Operating modes available for an LCP P unit which interfaces with a -pipe air conditioning system. In this kind of systems, it is possible to request air-conditioning and heating at the same time. For this reason, C and C hydraulic circuits respectively produce cold and hot water. In case of simultaneous operation of C and C hydraulic circuits, the condensation heat of the cooling system is totally recovered for the production of hot water. VM000-C 9

Total heat recovery multi-purpose units LCP Operating modes of the LCP M version C C C Cooling In the Chiller mode the LCP M multifunctional unit chills water to cool a room on the user side, dissipating the condensation heat in air by means of a finned block condenser. Heating The solution to the problem of defrosting During the wintertime period, especially with temperatures ranging between - C and + C, the high ambient relative humidity causes the formation of water condensation around the exchanger fins. Since the exchanger is at a lower temperature than the outdoor air, the water in contact with it ends up hindering the heat exchange necessary for the system to work correctly. A defrost cycle is a temporary reversal of the thermodynamic cycle which switches the unit into the summer mode and melts the ice present between fins. This phase is obviously problematic, since the cooling cycle warms up the exchanger by drawing heat from the room that was previously being heated. The circuit that is defrosting will draw heat on the user side (that is, not on the DHW side) if the unit is LCP M, and will heat on the hot water user side if the unit is LCP P. C In the Heat Pump mode the LCP M unit heats the water in the condenser to provide heating on the user side, absorbing the evaporative cooling capacity in air by means of a finned block heat exchanger. Separate defrosting C C Hot water production (for sanitary use-dhw) In the Production of High-temperature Hot Water for sanitary use (DHW) mode the LCP M multifunctional unit heats water in the second condenser, absorbing the evaporative cooling capacity in air by means of a finned block heat exchanger. C C C C Cooling and hot water production through total recovery In the Chiller + DHW mode the LCP M multifunctional unit can produce chilled water with the simultaneous production of high-temperature hot water for sanitary use, thanks to total heat recovery. C C Simultaneous Hot water production (for example for sanitary use) simultaneously with heating In the Simultaneous DHW Production and Heating mode the LCP M multifunctional unit heats water in parallel, optimally exploiting the complete independence of its thermodynamic circuits. Capacity is equally divided between the two circuits. The LCP unit reduces this problem with the following technical innovations: The two thermodynamic circuits in the LCP M LCP P are completely independent and while one defrosts, the other circuit is able to ensure continuity in the unit s operation, with practically no thermal discomfort for the user. Hydrophilic coils are installed; these break down the drops of water into particles and reduce the obstruction of the space between one fin and another caused by ice build-up. Thanks to a lower surface tension, the water tends to slide and precipitate by gravity, preventing the formation of frost at low temperatures. The software which manages the defrost cycle minimizes the time it takes to complete it and only acts when it is really necessary. The fans are pushed to their maximum capacity at just the right time, that is, when the ice is no longer stuck to the fins, and mechanically ejects it from the heat exchanger. Simultaneous 9 VM000-C

LCP - kw CONFIGURATION The models are completely configurable by selecting the version and the options. To the right is shown an example of configuration. AVAILABLE VERSIONS -pipe system versions LCP..MS Standard execution LCP-ML Low noise execution Version Fields 9 0 LCPPL 0 C 0 C P 0 0 G To verify the compatibility of the options, use the selection software or the price list. -pipe system versions LCP..PS Standard execution LCP-PL Low noise execution CONFIGURATION OPTIONS - POWER SUPPLY 0 00//0 + N 00//0 with transformer 00//0 + N + Circuit breakers 00//0 with transformer+ Circuit breakers - CONTROL MICROPROCESSOR AND THERMAL EXPANSION VALVE C Programmable (LCD x display) + mechanical expansion valve - WATER PUMP ON USER SIDE 0 Absent Single pump Uprated single pump Dual pump for combined operation Dual uprated pump for combined operation Dual pump with timed rotation Dual uprated pump with timed rotation - BUFFER TANK 0 Absent S Buffer tank on user side R Buffer tank on recovery side - WATER PUMP ON RECOVERY SIDE 0 Absent Single pump Uprated single pump Dual pump for combined operation Dual uprated pump for combined operation Dual pump with timed rotation Dual uprated pump with timed rotation - AIR FLOW MODULATION C Condensation control with fans adjusted by potentiometer E Condensation control, EC brushless electronically controlled fans ACCESSORIES A Power factor correction capacitors B Soft-starter kit C ON/OFF status of the compressors D Four Victaulic couplings for quick water IN-OUT connection E Outdoor temperature probe for setpoint compensation F Pressure gauges - ANTIFREEZE KIT 0 Absent E Present, basic unit (heating element only on exchangers) P Present, unit with pump/s and expansion tank S Present, unit with pump/s, expansion tank and tank - REMOTE COMMUNICATION 0 Absent RS Serial board (Modbus or Carel protocol) Lonworks serial board GSM modem kit Ethernet card (SNMP or BACNET protocol) + clock card Ethernet card + clock card + supervision software 9 - HEAT EXCHANGER CONSTRUCTION ON REQUEST 0 Standard R Copper / copper exchangers C Cataphoresis B Fins pre-coated with epoxy paint 0 - PACKING 0 Standard Wooden crate Wooden case - VIBRATION ISOLATION 0 Absent G Rubber vibration dampers at the base of the unit M Spring vibration dampers at the base of the unit - REMOTE CONTROL 0 Absent Remote display for programmable microprocessor G Regulating filter kit (solenoid and tap on the liquid line) H Normative reference other than "9//CE - PED" I Unit lifting kit L Finned heat exchanger protective grille M Metal filters for protecting finned heat exchanger Total heat recovery multi-purpose units - LCP VM000-C 9

Total heat recovery multi-purpose units LCP Rated technical data of models for -pipe systems + DHW LCP MS 9 0 Power supply V-ph-Hz 00-N-0 Cooling mode () Cooling capacity (E) kw,,,,, 0 Power input (E) kw,, 0,,,0,,0, EER (E),,0,,,0,,00,0 ESEER (E),,,9,,,,9, Eurovent efficiency class A B A A B A B B User side water flow l/h 99 9 Water pressure drop (E) kpa 9 Cooling mode + DHW () Cooling capacity kw 0,,,,, 0 0 DHW heating capacity kw,,,0 9, 0 9 Power input kw,, 0,,,,, 0, Total COP,,,,,,9,, User side water flow rate l/h 9 0 00 9 99 User side water pressure drops kpa 0 DHW side water flow rate l/h 0 9 0 0 9 DHW side water pressure drops kpa 0 0 Heating mode or DHW () Heating capacity (E) kw,,,, 9, Power input (E) kw,,,,,,,, COP (E),,,,,9,,, Eurovent efficiency class A A A A A A A A User side water flow rate l/h 9 0 0 9 9 0 User side water pressure drops (E) kpa 0 9 General data Maximum current absorption A 9 Startup current A 9 9 9 9 0 Startup current with softstarter kit A 0 0 9 9 No. of compressors / circuits / / / / / / / / Buffer tank volume dm 00 00 0 0 0 0 0 00 Expansion vessel dm Sound power level () (E) db(a) 0 0 Transport weight unit with pump and tank kg 90 00 0 0 90 0 0 Operating weight unit with pump and full tank kg 0 0 0 0 0 0 0 0 () Water temperature / C, outdoor air temperature C (UNI EN :0) () Water temperature / C, recovery water temperature 0 / C () Water temperature 0 / C, outdoor air temperature C D.B. / C W.B. (UNI EN :0) () Sound power level measured according to UNI EN ISO 9 (E) EUROVENT certified data 9 VM000-C

LCP - kw Rated technical data of models for -pipe systems + DHW LCP MS 9 9 Power supply V-ph-Hz 00-N-0 Cooling mode () Cooling capacity (E) kw 9 0 9 Power input (E) kw 9,,,,, 9, 0 EER (E),99,9,,90,,,9, ESEER (E),,0,,9,0,9,9, Eurovent efficiency class B B C B C C C D User side water flow l/h 099 0 9 Water pressure drop (E) kpa 9 9 9 Cooling mode + DHW () Cooling capacity kw 9 0 DHW heating capacity kw 9 Power input kw,, 0, 0,,0, 9, 0 Total COP,,,9,,,,,0 User side water flow rate l/h 0 9 99 9 9 090 User side water pressure drops kpa 0 0 9 DHW side water flow rate l/h 0 9 9 00 9 DHW side water pressure drops kpa 9 9 9 9 9 Heating mode or DHW () Heating capacity (E) kw 9 Power input (E) kw 0,,,, 0,, 99, 0 COP (E),,,,,,,, Eurovent efficiency class A A A A A A A B User side water flow rate l/h 9 0 9 9 9 90 User side water pressure drops (E) kpa 9 0 General data Maximum current absorption A 0 90 9 Startup current A 0 9 Startup current with softstarter kit A 00 0 9 0 0 No. of compressors / circuits / / / / / / / / Buffer tank volume dm 00 00 00 00 00 Expansion vessel dm Sound power level () (E) db(a) Transport weight unit with pump and tank kg 0 90 90 90 90 0 90 0 Operating weight unit with pump and full tank kg 0 0 0 0 0 0 0 0 Total heat recovery multi-purpose units - LCP () Water temperature / C, outdoor air temperature C (UNI EN :0) () Water temperature / C, recovery water temperature 0 / C () Water temperature 0 / C, outdoor air temperature C D.B. / C W.B. (UNI EN :0) () Sound power level measured according to UNI EN ISO 9 (E) EUROVENT certified data VM000-C 9

Total heat recovery multi-purpose units LCP Rated technical data of models for -pipe systems + DHW LCP ML 9 0 Power supply V-ph-Hz 00-N-0 Cooling mode () Cooling capacity (E) kw 9,,, 0,, 9, 0 Power input (E) kw,, 0,9,0,0,,,0 EER (E),00,,09,9,9,9,, ESEER (E),,,0,,,0,,9 Eurovent efficiency class B C B B C B C C User side water flow l/h 9 9 90 Water pressure drop (E) kpa 0 9 Cooling mode + DHW () Cooling capacity kw 0,,,,, 0 0 DHW heating capacity kw,,,0 9, 0 9 Power input kw,, 0,,,,, 0, Total COP,,,,,,9,, User side water flow rate l/h 9 0 00 9 99 User side water pressure drops kpa 0 DHW side water flow rate l/h 0 9 0 0 9 DHW side water pressure drops kpa 0 0 Heating mode or DHW () Heating capacity (E) kw,0,,0 9, 9,0 Power input (E) kw,, 0,,,,,9,9 COP (E),9,,,,,,,9 Eurovent efficiency class A A A A A A A A User side water flow rate l/h 9 0 0 909 09 9 User side water pressure drops (E) kpa 0 0 0 General data Maximum current absorption A 9 Startup current A 9 9 9 9 0 Startup current with softstarter kit A 0 0 9 9 No. of compressors / circuits / / / / / / / / Buffer tank volume dm 00 00 0 0 0 0 0 00 Expansion vessel dm Sound power level () (E) db(a) 9 Transport weight unit with pump and tank kg 9 00 0 0 0 0 0 0 Operating weight unit with pump and full tank kg 09 0 0 0 0 0 0 () Water temperature / C, outdoor air temperature C (UNI EN :0) () Water temperature / C, recovery water temperature 0 / C () Water temperature 0 / C, outdoor air temperature C D.B. / C W.B. (UNI EN :0) () Sound power level measured according to UNI EN ISO 9 (E) EUROVENT certified data 9 VM000-C

LCP - kw Rated technical data of models for -pipe systems + DHW LCP ML 9 9 Power supply V-ph-Hz 00-N-0 Cooling mode () Cooling capacity (E) kw 9 0 Power input (E) kw, 9,,,,0 9, 0 9 EER (E),9,9,,,,9,9, ESEER (E),9,9,9,,0,9,9,9 Eurovent efficiency class D D C C C C C D User side water flow l/h 99 99 00 0 Water pressure drop (E) kpa 0 Cooling mode + DHW () Cooling capacity kw 9 0 DHW heating capacity kw 9 Power input kw,, 0, 0,,0, 9, 0 Total COP,,,9,,,,,0 User side water flow rate l/h 0 9 99 9 9 090 User side water pressure drops kpa 0 0 9 DHW side water flow rate l/h 0 9 9 00 9 DHW side water pressure drops kpa 9 9 9 9 9 Heating mode or DHW () Heating capacity (E) kw 9 9 Power input (E) kw,0,0,,,, 9,9 0 COP (E),,0,,,,,, Eurovent efficiency class A A A A A A A B User side water flow rate l/h 0 0 9 0 09 9 90 User side water pressure drops (E) kpa 9 General data Maximum current absorption A 0 90 9 Startup current A 0 9 Startup current with softstarter kit A 00 0 9 0 0 No. of compressors / circuits / / / / / / / / Buffer tank volume dm 00 00 00 00 00 Expansion vessel dm Sound power level () (E) db(a) 9 0 Transport weight unit with pump and tank kg 0 0 90 90 90 90 0 0 Operating weight unit with pump and full tank kg 90 0 Total heat recovery multi-purpose units - LCP () Water temperature / C, outdoor air temperature C (UNI EN :0) () Water temperature / C, recovery water temperature 0 / C () Water temperature 0 / C, outdoor air temperature C D.B. / C W.B. (UNI EN :0) () Sound power level measured according to UNI EN ISO 9 (E) EUROVENT certified data VM000-C 99

Total heat recovery multi-purpose units LCP Rated technical data of models for -pipe systems LCP PS 9 0 Power supply V-ph-Hz 00-N-0 Cooling mode () Cooling capacity (E) kw,,,,, 0 Power input (E) kw,, 0,,,0,,0, EER (E),,0,,,0,,00,0 ESEER (E),,,9,,,,9, Eurovent efficiency class A B A A B A B B User side water flow l/h 99 9 Water pressure drop (E) kpa 9 Cooling and heating mode in total heat recovery () Cooling capacity kw 0,,,,, 0 0 Heating capacity kw,,,0 9, 0 9 Power input kw,, 0,,,,, 0, Total COP,,,,,,9,, Cooling side water flow rate l/h 9 0 00 9 99 Cooling side water pressure drops kpa 0 Heating side water flow rate l/h 0 9 0 0 9 Heating side water pressure drops kpa 0 0 Heating mode () Heating capacity (E) kw,,,, 9, Power input (E) kw,,,,,,,, COP (E),,,,,9,,, Eurovent efficiency class A A A A A A A A User side water flow rate l/h 9 0 0 9 9 0 User side water pressure drops (E) kpa 0 9 General data Maximum current absorption A 9 Startup current A 9 9 9 9 0 Startup current with softstarter kit A 0 0 9 9 No. of compressors / circuits / / / / / / / / Buffer tank volume dm 00 00 0 0 0 0 0 00 Expansion vessel dm Sound power level () (E) db(a) 0 0 Transport weight unit with pump and tank kg 9 00 00 00 00 0 0 Operating weight unit with pump and full tank kg 0 09 0 0 00 0 0 0 () Water temperature / C, outdoor air temperature C (UNI EN :0) () Water temperature / C, recovery water temperature 0 / C () Water temperature 0 / C, outdoor air temperature C D.B. / C W.B. (UNI EN :0) () Sound power level measured according to UNI EN ISO 9 (E) EUROVENT certified data 00 VM000-C

LCP - kw Rated technical data of models for -pipe systems LCP PS 9 9 Power supply V-ph-Hz 00-N-0 Cooling mode () Cooling capacity (E) kw 9 0 9 Power input (E) kw 9,,,,, 9, 0 EER (E),99,9,,90,,,9, ESEER (E),,0,,9,0,9,9, Eurovent efficiency class B B C B C C C D User side water flow l/h 099 0 9 Water pressure drop (E) kpa 9 9 9 Cooling and heating mode in total heat recovery () Cooling capacity kw 9 0 Heating capacity kw 9 Power input kw,, 0, 0,,0, 9, 0 Total COP,,,9,,,,,0 Cooling side water flow rate l/h 0 9 99 9 9 090 Cooling side water pressure drops kpa 0 0 9 Heating side water flow rate l/h 0 9 9 00 9 Heating side water pressure drops kpa 9 9 9 9 9 Heating mode () Heating capacity (E) kw 9 Power input (E) kw 0,,,, 0,, 99, 0 COP (E),,,,,,,, Eurovent efficiency class A A A A A A A B User side water flow rate l/h 9 0 9 9 9 90 User side water pressure drops (E) kpa 9 0 General data Maximum current absorption A 0 90 9 Startup current A 0 9 Startup current with softstarter kit A 00 0 9 0 0 No. of compressors / circuits / / / / / / / / Buffer tank volume dm 00 00 00 00 00 Expansion vessel dm Sound power level () (E) db(a) Transport weight unit with pump and tank kg 9 9 9 0 0 0 0 Operating weight unit with pump and full tank kg 9 9 0 0 Total heat recovery multi-purpose units - LCP () Water temperature / C, outdoor air temperature C (UNI EN :0) () Water temperature / C, recovery water temperature 0 / C () Water temperature 0 / C, outdoor air temperature C D.B. / C W.B. (UNI EN :0) () Sound power level measured according to UNI EN ISO 9 (E) EUROVENT certified data VM000-C 0

Total heat recovery multi-purpose units LCP Rated technical data of models for -pipe systems LCP PL 9 0 Power supply V-ph-Hz 00-N-0 Cooling mode () Cooling capacity (E) kw 9,,, 0,, 9, 0 Power input (E) kw,, 0,9,0,0,,,0 EER (E),00,,09,9,9,9,, ESEER (E),,,0,,,0,,9 Eurovent efficiency class B C B B C B C C User side water flow l/h 9 9 90 Water pressure drop (E) kpa 0 9 Cooling and heating mode in total heat recovery () Cooling capacity kw 0,,,,, 0 0 Heating capacity kw,,,0 9, 0 9 Power input kw,, 0,9,0,0,,,0 Total COP,,,,,,9,, Cooling side water flow rate l/h 9 0 00 9 99 Cooling side water pressure drops kpa 0 Heating side water flow rate l/h 0 9 0 0 9 Heating side water pressure drops kpa 0 0 Heating mode () Heating capacity (E) kw,0,,0 9, 9,0 Power input (E) kw,, 0,,,,,9,9 COP (E),9,,,,,,,9 Eurovent efficiency class A A A A A A A A User side water flow rate l/h 9 0 0 909 09 9 User side water pressure drops (E) kpa 0 0 0 General data Maximum current absorption A 9 Startup current A 9 9 9 9 0 Startup current with softstarter kit A 0 0 9 9 No. of compressors / circuits / / / / / / / / Buffer tank volume dm 00 00 0 0 0 0 0 00 Expansion vessel dm Sound power level () (E) db(a) 9 Transport weight unit with pump and tank kg 9 90 00 00 090 0 0 Operating weight unit with pump and full tank kg 09 0 0 0 0 0 0 () Water temperature / C, outdoor air temperature C (UNI EN :0) () Water temperature / C, recovery water temperature 0 / C () Water temperature 0 / C, outdoor air temperature C D.B. / C W.B. (UNI EN :0) () Sound power level measured according to UNI EN ISO 9 (E) EUROVENT certified data 0 VM000-C

LCP - kw Rated technical data of models for -pipe systems LCP PL 9 9 Power supply V-ph-Hz 00-N-0 Cooling mode () Cooling capacity (E) kw 9 0 Power input (E) kw, 9,,,,0 9, 0 9 EER (E),9,9,,,,9,9, ESEER (E),9,9,9,,0,9,9,9 Eurovent efficiency class D D C C C C C D User side water flow l/h 99 99 00 0 Water pressure drop (E) kpa 0 Cooling and heating mode in total heat recovery () Cooling capacity kw 9 0 Heating capacity kw 9 Power input kw. 9....0 9. 0 9 Total COP...9.....0 Cooling side water flow rate l/h 0 9 99 9 9 090 Cooling side water pressure drops kpa 0 0 9 Heating side water flow rate l/h 0 9 9 00 9 Heating side water pressure drops kpa 9 9 9 9 9 Heating mode () Heating capacity (E) kw 9 9 Power input (E) kw,0,0,,,, 9,9 0 COP (E),,0,,,,,, Eurovent efficiency class A A A A A A A B User side water flow rate l/h 0 0 9 0 09 9 90 User side water pressure drops (E) kpa 9 General data Maximum current absorption A 0 90 9 Startup current A 0 9 Startup current with softstarter kit A 00 0 9 0 0 No. of compressors / circuits / / / / / / / / Buffer tank volume dm 00 00 00 00 00 Expansion vessel dm Sound power level () (E) db(a) 9 0 Transport weight unit with pump and tank kg 9 90 0 0 00 Operating weight unit with pump and full tank kg 90 0 Total heat recovery multi-purpose units - LCP () Water temperature / C, outdoor air temperature C (UNI EN :0) () Water temperature / C, recovery water temperature 0 / C () Water temperature 0 / C, outdoor air temperature C D.B. / C W.B. (UNI EN :0) () Sound power level measured according to UNI EN ISO 9 (E) EUROVENT certified data VM000-C 0

Total heat recovery multi-purpose units LCP Dimensional drawings LCP - 0 0 (0) 9 0 90 0 0 9 90 0 90 0 90 0 9 (0) 9 90 0 90 - PIEDINI ANTIVIBRANTI - GRIGLIA DI PROTEZIONE (OPZIONALE) - PUNTI DI SOLLEVAMENTO - INGRESSO ACQUA CALDA (VICTAULIC ") - INGRESSO ACQUA FREDDA (VICTAULIC ") - USCITA ACQUA CALDA (VICTAULIC ") - USCITA ACQUA FREDDA (VICTAULIC ") - INGRESSO ALIMENTAZ. ELETTRICA, LEGEND 0 Vibration dampers Protective grille (optional) Fastening points Hot water inlet (Victaulic ) Cold water inlet (Victaulic ) Hot water outlet (Victaulic ) Model Cold water outlet (Victaulic ) LCP Power supply input LCP Version VM000-C

LCP - kw Dimensional drawings LCP - 9 9 0 0 0 90 0 90 0 90 0 0 90 Total heat recovery multi-purpose units - LCP 0 90 9 0 0 90 9 - PIEDINI ANTIVIBRANTI - GRIGLIA DI PROTEZIONE (OPZIONALE) - PUNTI DI SOLLEVAMENTO - INGRESSO ACQUA CALDA (VICTAULIC ") - INGRESSO ACQUA FREDDA (VICTAULIC ") - USCITA ACQUA CALDA (VICTAULIC ") - USCITA ACQUA FREDDA (VICTAULIC ") - INGRESSO ALIMENTAZ. ELETTRICA LEGEND Vibration dampers Protective grille (optional) Fastening points Hot water inlet (Victaulic ) Cold water inlet (Victaulic ) Hot water outlet (Victaulic ) LCP Cold water outlet (Victaulic ) LCP Power supply input LCP VM000-C Model Version 0,

Total heat recovery multi-purpose units LCP Dimensional drawings LCP 9-0 0 0 90 0 90 0 0 90 0 0 90 90 0 90 0 9 9 9 - PIEDINI ANTIVIBRANTI - GRIGLIA DI PROTEZIONE (OPZIONALE) - PUNTI DI SOLLEVAMENTO - INGRESSO ACQUA CALDA (VICTAULIC /") - INGRESSO ACQUA FREDDA (VICTAULIC /") - USCITA ACQUA CALDA (VICTAULIC /") - USCITA ACQUA FREDDA (VICTAULIC /") - INGRESSO ALIMENTAZ. ELETTRICA LEGEND 0 Vibration dampers Protective grille (optional) Fastening points Hot water inlet (Victaulic ½ ) Cold water inlet (Victaulic ½ ) Hot water outlet (Victaulic ½ ) Model Cold water outlet (Victaulic ½ ) LCP 9 Power supply input LCP 0 Version VM000-C

LCP - kw Dimensional drawings LCP - 9 USER INTERFACE (OPTIONAL) USER INTERFACE (OPTIONAL) 9 0 0 0 0 0 9 00 0 00 00 0 0 Total heat recovery multi-purpose units - LCP 9 0 0 0 0 LEGEND Vibration dampers Protective grille (optional) Fastening points Hot water inlet (Victaulic ) Model Cold water inlet (Victaulic ) LCP Hot water outlet (Victaulic ) LCP Cold water outlet (Victaulic ) LCP Power supply input LCP 9 VM000-C Version 0

Total heat recovery multi-purpose units LCP Dimensional drawings LCP - 9 9 0 0 9 0 * with EC0 FANS 0 9 00 9 9 0 0 0 0* 0* 00 00 00 00 00 * with EC FANS - PIEDINI ANTIVIBRANTI - GRIGLIA DI PROTEZIONE (OPZIONALE) - PUNTI DI SOLLEVAMENTO - PIEDINI ANTIVIBRANTI 0 - GRIGLIA DI PROTEZIONE (OPZIONALE) - USCITA ACQUA CALDA (VICTAULIC ") - INGRESSO ACQUA FREDDA (VICTAULIC ") - INGRESSO ALIMENTAZ. ELETTRICA - USCITA ACQUA FREDDA (VICTAULIC ") 9 - INTERFACCIA UTENTE (OPZIONALE) - INGRESSO ALIMENTAZ. ELETTRICA 0 - USCITA ACQUA FREDDA (VICTAULIC ") - USCITA ACQUA CALDA (VICTAULIC ") 9 - INTERFACCIA 00 UTENTE (OPZIONALE) - INGRESSO ACQUA FREDDA (VICTAULIC ") - INGRESSO ACQUA CALDA (VICTAULIC ") 9 - INGRESSO ACQUA CALDA (VICTAULIC ") - PUNTI DI SOLLEVAMENTO 00 00 LEGEND 0 Vibration dampers Protective grille (optional) Fastening points Hot water inlet (Victaulic ) Cold water inlet (Victaulic ) Hot water outlet (Victaulic ) Cold water outlet (Victaulic ) Power supply input LCP 9 User interface (optional) LCP Model Version VM000-C

LCP - kw Dimensional drawings LCP - 0 0 9 0* 9 00 9 9 9 9 * with EC FANS9 0 0 9 00 00 0 0 0 00 0 ANS 00 00 0 00 0 Total heat recovery multi-purpose units - LCP 00 LEGEND Vibration dampers Protective grille (optional) Fastening points Hot water inlet (Victaulic ) Cold water inlet (Victaulic ) Hot water outlet (Victaulic ) Model Cold water outlet (Victaulic ) LCP Version Power supply input LCP 9 9 User interface (optional) LCP VM000-C 09