Contents 1. GENERAL DESCRIPTION TECHNICAL DATA INSTALLATION...4

Similar documents
User Manual. Reflow Batch Oven Model: X-REFLOW305

LED New Light Source Reflow Oven. Model: T-960

AUTOMATED PRODUCTION SYSTEMS, INC Pine Road Huntingdon Va l l ey PA P h o n e : (215) FA X : (215)

Mini SMT Reflow Oven Model: T-961

Quick-Start Guide Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input Models and

WHA 3000V Hot Air Station

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Table 1. Serie of Digital Room Thermostats.

Operation and Maintenance Manual for the SODRTEK ST 325 Digital Convective Soldering/Desoldering System P/N

FULL CONVECTION REFLOW OVEN

User Manual. Digi-Sense TC9600 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

Jetstream Series HPLC - PELTIER COLUMN-THERMOSTATS 1. GENERALITIES

Oakton TEMP 9500 Advanced Multiparameter Controller

INFRARED IC HEATER Model: T962C. User Manual.

FORCED CONVECTION REFLOW SYSTEM TWS 800A/AZ USER MANUAL

Economical Lead Free Reflow Oven Series

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

I760B-DX BGA Rework System. Operation Manual

1 NORMS AND REGULATIONS Guarantee norms: Environmental notes: Identification:... 15

BTU Units WORKING PROGRAM MANUAL

Repair under control

JOVY SYSTEMS RE User Manual Rev. 1.00

FULL CONVECTION REFLOW OVEN

QUICK BGA2015. Precision BGA Rework System. Features:

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

JOVY SYSTEMS RE-7500 User Manual Rev Index

Oakton TEMP 9000 Advanced Thermocouple Controller

108A OTP1800. Grid Support. General Description

WHA 3000P Hot Air Station

DT968C C.T. BATH CONTROLLER

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it.

Table of Contents DIGITAL DRYING OVEN. Features. Setup. Cautions. Description of the parts. Temperature Controls. Maintenance and Storage

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

Table Of Contents

Cimco Series 21. Series 21 - Operator Instruction Manual INDEX. Description. Standard Instructions 2 to 4. Operating Control Panel 5

aoyue Int732 INSTRUCTION MANUAL Game Console Reworking System

HPS-C-MULTI 6. Hotrunner Controllers. Operating manual. Valid for item numbers:

CG Series Digital Temperature Controller OPERATIONS MANUAL

Instruction manual. Remote control electric IR HEATER

QK-IR2005. User s Manual

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

HA06. User manual. (SDO Hot Air One) HOT AIR / QUARTZ REFLOW OVEN. Version 2.21

DT6500 CONTROLLER. for the ICD PART #: ICD SERIAL #: 1714

Instruction Manual. Programmable Ovens. 625 East Bunker Court Vernon Hills. IL

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

S ATION EWORK ST BGA R

RD-500V RD-500SV ESD SMT REWORK SYSTEM

RD-500V RD-500SV ESD SMT REWORK SYSTEM

ELITE-600 DENTAL PORCELAN FURNACE

Pellet burner PV 180a. User manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT HCT-1000 User Guide

INFRARED IC HEATER. Model: T962. User Manual

Reflow Soldering Guidelines

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

BGA Rework Station TOUCHBGA GM490 User Manual

HIGH QUALITY VAPOR PHASE REFLOW SOLDERING. SMTA Arizona-Sonora December 4th 2012

Installation & Maintenance Manual

ECO N DATE DESCRIPTION OF CHANGE CHG

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

QUICK BGA2015 BGA/SMD Rework System. Operation Manual

touchbga.com TOUCHBGA BGA Rework Station HR6000 User Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

E-THERM /M-400 Medium Volume Lead Free Wave Solder Machine

touchbga.com TOUCHBGA BGA Rework Station GM330 IR+HR User Manual

Conveyor and Batch Reflow Ovens

Specifications Minimum Typical Maximum Unit

NOTEBOOK I 760 BGA/SMD Rework System. Operation Manual

Instruction Manual. Isotemp Programmable Ovens 800 Series

Automatic Isokinetic Sampler ST5

Figure 1-1 Furnace Front Elevation


SMT Quick-Tips: selecting a reflow oven. Robert Voigt, DDM Novastar

Technical Seminar HL-BD82S. Electric Built-In Oven. Panasonic Canada 2013

HOT BAR REFLOW SOLDERING FUNDAMENTALS by Amada Miyachi Europe A high quality Selective Soldering Technology

SN210/310/510, SQ510/810C

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

OPERATING AND MAINTENANCE MANUAL

TEMPERATURE CONTROLLER

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

Accessories for WHA 3000P and WHA 3000V

VIDEO CONTROLS LIMITED

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Technicians Manual Single Compressor

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Electronic Pellet Burner Controller NPBC-V3-1

SEMTIC HEATING

Products documentation (REVISION DATE: 03/10/2011) OMFP6010 (60cm PIROLITIC OVEN)

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

WIRED CONTROLLER MANUAL

Operating Functions Temperature Parameters

BGA Rework Station Pro-660

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Heated and Refrigerated Incubators

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Transcription:

Infrared reflow oven MR10 2 Contents 1. GENERAL DESCRIPTION...3 1.1. TECHNICAL DATA...3 2. INSTALLATION...4 3. CONTROL SYSTEM...5 3.1. CONTROL PANEL...5 4. SOLDERING PARAMETERS SETUP...8 4.1. MANUAL PROFILE SETUP...8 4.1.1. Heater Profile Setup...8 4.1.2. Time Setup...9 4.2. AUTO PROFILING (MR10A ONLY)...9 5. EXAMPLE FOR SOLDERING PROFILES SETUP...11 6. MALFUNCTIONS / ERROR MESSAGES...12 7. LIST OF SPARE PARTS...13 8. ELECTRICAL DIAGRAM...14

Infrared reflow oven MR10 3 1. General Description Mechatronika s infrared reflow oven MR10 ca be used for hardening glue spots as well as for the soldering process on surface mounted printed circuits boards. MR10 controls the process according to previously defined time/temperature profiles, after the PCB has been feeded into transport frame. The transport frame goes through 3 (4) processing sections: initial preheating area preheating area soldering area dwell area (for lead free process) After pressing the START-key the transport frame brings the PCB into the initial preheating area (soldering area), leaving it for T F seconds there while the PCB reaches it's preheating temperature T P1.Then the transport frame travels into preheating and stays at this temperature for T P seconds. So the PCB can reach T P2 temperature, where the volatile components of solder paste vaporise out. Then the transport frame travels into reflow area to melt the solder paste into solid connections (reflow temperature T R for T R seconds). For lead free process transport frame travels back to preheating for T D seconds to create plateau. The soldering process ends with cooling the PCB down, the transport frame will run into its original position, while a optional fan is activated for T C seconds. Separating the soldering process into four explicitly definable phases with microprocessor control and auto profiling system, the PID control and the precise stepper-motordriven transport system realise a highly accurate soldering process control. 1.1. Technical Data pcb size...170x270 mm pcb transport...transport frame, moving back to feeding position after soldering process heating elements... 0,7kW and 1,3kW far infrared heater control... microprocessor, PID-control, 12 soldering profiles power consumption...2kw max, average cycle power 1,4kW power supply...230v±10%; 50Hz dimensions (l x w x h)...900x520x350mm weight...45kg

Infrared reflow oven MR10 4 2. Installation The reflow oven MR10 should be installed according to fig.2 and can be connected to used air flue with fan, which is to be wired to one of the plugs in the rear panel of the machine. So the fan is activated only in the cooling phase of the soldering process. The reflow oven doesn't need any maintenance. If performance of heaters drops, check whether the fuses in the rear panel of the machine are intact and change in case of damage. Fig.2: Installation of MR10

Infrared reflow oven MR10 5 3. Control system Fig.3 shows the functional blocks of MR10 s control system: Fig.3: MR10 control systems 3.1. Control Panel Control panel contains the following functional elements: Main switch LCD display Keyboard Temperature probe plug

Infrared reflow oven MR10 6 Fig.4: MR10 control panel The following information are shown on LCD-display: soldering profile number soldering parameters belonging to this profile actual soldering phase with auto profiling system: actual soldering temperature on pcb The keyboard has the following functions: PROFILE... chooses number of soldering profile TIME... time setup for all soldering phases (F/P/R/D/C) TEMP... temperature setup for all soldering phases (P/R) (-)... reduces value of parameter on display (+)... increases value of parameter on display ENTER... stores parameter on display to memory if pressed during soldering process: stops actual process and starts next one START...starts soldering process STOP... stops actual sequence of soldering process and moves transport frame to feeding position

Infrared reflow oven MR10 7 if pressed during parameter setup process: display shows the actual temperature of heaters

Infrared reflow oven MR10 8 4. Soldering parameters setup The following parameters can be defined for the different soldering profiles: Process time: F... initial preheating time P... preheating time R... reflow time D...dwell time C... cooling time Process temperatures: P... preheating heater temperature R... reflow heater temperature process temp. Tr Tp T P2 T P1 t F tp t R t D tc Process Fig.5: soldering profile time 4.1. Manual Profile Setup For manual setup of soldering process the temperatures of both heater areas and the times, the pcb will stay in them, have to be defined as follows: 4.1.1. Heater Profile Setup For heater temperature setup proceed as follows:

Infrared reflow oven MR10 9 Action, Key System answer press PROFILE key until number of profile to be altered is shown press TEMP key LCD shows actual temperature setup for P- area press (+) or (-) key until right value is shown on display press ENTER key previously defined setup parameters are press TEMP key adjust display value with (+) and (-) key press ENTER key 4.1.2. Time Setup For time setup proceed as follows: stored to memory LCD display proceeds to temperature setup for R-area Action, key press PROFILE key until LCD-display shows the number of the profile to be altered press TIME key press (+) or (-) key until right value is shown on display press ENTER key press TIME key System answer LCD display shows actual time setup (first for phase F) previously defined setup parameters are stored to memory LCD display shows actual time setup for next phase (P)...procedure continues as before for all soldering phases. 4.2. Auto Profiling (MR10A only) Auto profiling mode measures the actual temperature on PCB and compares it with the desired value, thus determining, how long the PCB has to stay in the single heating areas. The actual temperature is measured with means of an temperature probe plugged into the control panel of MR10A, whose active end is fixed to the PCB while running through soldering process. Before auto profiling mode both heater area temperatures have to be defined according to 4.1.1. Then proceed as follows:

Infrared reflow oven MR10 10 Action, key System answer press PROFILE key to reach desired number of the profile desired profile number press ENTER key for several seconds profile setup press TEMP key adjust right value by pressing (-) or (+) key press ENTER key LCD shows actual temperature setup for Tpl (starting temperature for heating process) stores adjusted value to memory...procedure continues as before for defining the other profile temperatures T P2 (end of heating process), T R (reflow temperature) and T C (cooling temperature). press START press ENTER for memorise measured time intervals or STOP to skip them The transport frame goes into the heating areas; control system displays actual time and measured temperature on the PCB. On the end control system displays 4 measured times.

Infrared reflow oven MR10 11 5. Example for soldering profiles setup The following setup parameters should only be the starting point for further tests to reach solid soldering joints: Standard solder paste temperature time T P =180 C t F =15s t P =180s T R =420 C t R =25s t D =0s t C =30s Lead free solder paste temperature time T P =190 C t F =0s t P =150-180s T R =430 C t R =30s t D =20s t C =30s

Infrared reflow oven MR10 12 6. Malfunctions / error messages 6.1 Malfunctions Machine does not start after switch-on Check power connection Check fuses on the rear side of the oven NOT READY message on the display after pressing START key The heaters didn't reach programmed temperatures; press STOP key to terminate Start command or wait for readiness of the heaters If NOT READY message displays longer than 1 hour check the fuses; if fuses are good contact with service 6.2 Error messages on the display Message POSITIONING ERROR INITIALIZATION ERROR OPEN TERMOCOUPLE ERROR EEPROM Meaning Stepper motor miss the position during positioning; if message displays several times contact with service for cleaning positioning system Transport frame didn't reach Home position in programmed time; if motor didn't start check fuses; if transport frame starts, but moves badly contact with service for cleaning positioning system Contact with service for thermocouple changing Eeprom content corrupted; contact with service for advice

Infrared reflow oven MR10 13 7. List of spare parts 1. Thermocouple for heaters MR10.100 2. Thermocouple for auto profiling MR10.105 3. Heater for preheating area MR10.110 4. Heater for soldering (reflow) area MR10.120 5. Control board MR10.200 6. Contactor (relay) MR10.210 7. Keyboard / display assembly MR10.220 8. Motor assembly MR10.230 9. Fan MR10.240

Infrared reflow oven MR10 14 8. Electrical diagram