Purge Ventilation Unit. Product Manual. ventilation systems TP625

Similar documents
Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

Warnings, Safety Information and Guidance

Heat Recovery Ventilation Units. LED Status Indicator. Product Manual. ventilation systems. auralite compatible HRV units

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

HRV10 Q Plus TP440A TP440ABD TP440ABS. HRV10M Q Plus TP441A TP441ABD TP441ABS. Heat Recovery Ventilation Unit Product Manual

WHHR Midi & Midi Lite

aura-t TP536/GBR ventilation systems

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

Section HMB/HMBE. Section B/BE. Heat Recovery Ventilation Units. LED Status Indicator. Product Manual. ventilation systems

aura-t TP536/EU ventilation systems

Lo-Carbon Quadra Centrifugal Fan

G Installation manual Solitude - dmev unit

Centrif Duo & Centrif Duo Plus

HOTLINE:

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra SELV

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions

Installation and Maintenance

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

ART cm Island Curved Glass

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

PLEASE READ ALL SECTIONS OF THIS GUIDE BEFORE COMMENCING YOUR INSTALLATION AND IN CONJUNCTION WITH YOUR DRAWINGS.

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

Thank you for choosing EnviroVent

Lo-Carbon Quadra Centrifugal Fan

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Lo-Carbon SELV Tempra

Xpelair Simply Silent TM Contour Fan

Installation and Maintenance

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Installation and Wiring Instructions

Exhaust Duct Design Page 1 of (C)

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Installation and Maintenance

Installation and Maintenance

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

VENT TREX. Product Guide

Installation and Maintenance

Xpelair Simply Silent TM DX100 Fan

Installation and Maintenance

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Installation and Maintenance

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

100cm Chimney Hood GB IE

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Thank you for choosing EnviroVent

Xpelair Simply Silent DX150

Stainless Steel Chimney Extractor

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

CG60/ 70/ 80/ 90/ 100 SS/BK

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

Wiring the fan correctly...

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX. Model may vary slightly from images pictured. All measurements are in mm.

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

Silhouette Installation and Wiring Instructions

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Xcell 270 Longlife DC wholehouse heat recovery unit

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

USER MANUAL. ICON60H Version 00. Vertical Glass Hood

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Xpelair Simply Silent DX100

Stainless Steel Chimney Extractor

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

November This product has been reconfigured Please read these instructions

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

User and maintenance manual

GB User and maintenance manual

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

100 FLUEBOOST

Installation manual Mori HR

Instructions for use

Stainless Steel T-Box Extractor

Xpelair Simply Silent DX100B

Cooker Hood Instruction Manual

Transcription:

EN Purge Ventilation Unit TP625 Product Manual ventilation systems

Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this appliance 1. Installation of the appliance and accessories must be carried out by a qualified and suitable competent person and be carried out in clean, dry conditions where dust and humidity are at minimal levels. 2. This manual covers the installation of the Purge Ventilation Unit. 3. All wiring must conform to current I.E.E. Wiring Regulations and all applicable standards and Building Regulations. 4. Inspect the appliance and electrical supply cord. If the supply cord is damaged, it must be replaced by the manufacturer, their service agent or similarly qualified persons in order to avoid a hazard. 5. The unit is supplied with a mains rated 3 core flexible cord (PVC sheathed, brown, blue and green/yellow 0.75mm²). 6. The appliance must be connected to a local double pole isolation switch with a contact separation of at least 3mm. 7. The appliance must be earthed. 8. The appliance is suitable for 220-240V~ 50-60Hz single phase with a fuse rating of 3A. 9. Ensure all cable glands are fully tightened. 10. The unit must be stored in a clean and dry environment. Do not install the appliance in areas where the following may be present or occur; Excessive oil or a grease laden atmosphere, Corrosive or flammable gases, liquids or vapours, Ambient temperatures above 40 C or below -5 C, Humidity levels above 90% or is a wet environment. 11. The appliance is not suitable for installation to the exterior of the dwelling. 12. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children should be supervised to ensure that they do not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 13. Ensure that external grilles are located away from any flue outlet, in accordance with relevant Building Regulations. 14. The unit must not be connected to a tumble dryer or a cooker hood. 15. Precautions must be taken to avoid the back-flow of gases into the room from an open flue appliance. 16. Ensure all ducting is free from debris and and blockages before switching on. 2

Explanation of symbols on the appliance. Read instruction Manual. Risk of Electric Shock. General hazard safety alert. Disconnect the mains supply before removing this cover. Wait until all machine components have completely stopped before touching them. + 3

Contents Warnings, Safety Information and Guidance Important Information 2 Explanation of symbols on the appliance. 3 Product Information Product Features 5 Packaging Contents 5 Recommended Accessories 5 Other Accessories Available 5 Dimensions 6 Component Identification 7 Installation Fixing 8 Ducting Connections 9 Wiring Connection Access 11 Commissioning TP625A 12 Hardware Reset 12 Maintenance Routine Maintenance 13 When this document is viewed as a PDF the headings & sub headings on this page are hyper links to the content. Additionally the page numbers in this document are hyper links back to this contents page. 4

Product Information The Purge Ventilation Unit provides an effective solution for the rapid removal of pollutants from within the home. Product Features Compact low profile unit. Straight forward Installation. Easy access mounting fixings. Commissionable via a single pot. Configurable between Inline flow and right angle flow directions. 220x90mm ducting compatible, reducers / converters available for converting to alternative ducting sizes, such as 204x60, Ø150mm etc. Packaging Contents Inspect the unit when taking delivery. Check the unit for damage and that all accessories have been supplied. Package supplied with; Purge Unit x 1. 220x90 inline port. Product Manual x 1. EuP Documentation. Any shortages or damage must be immediately reported to the supplier. Recommended Accessories Titon recommend the following accessories to be installed with the unit as part of a complete ventilation system solution: Ø150mm sprung backdraft damper. Ø150mm ducting or 220x90mm (depending on system design). 220x90mm to Ø150mm transformation ducting. Ø150mm Mains Actuated Backdraught Damper. TP 630 Ø150mm external wall vent. Internal ceiling or wall vent (depending on system design). 450x300mm ceiling access panel (depending on install location). Ceiling cover plate. Other Accessories Available Titon offer a range of complimentary ducting and unit accessories that could be fitted to this unit if required, such as: Acoustic ducting. Anti-vibration pads. 5

Dimensions The diagram details the overall size of the unit and the additional space required around the unit to allow for commissioning and future servicing and maintenance. 100 150 293 340 540 482 452 265 6

Component Identification Access Cover Optional 90 Inlet Cover Control Board Fan Inlet 220 x 90 Base Unit 7

Installation Fixing 1. The unit must be securely fixed to a smooth flat surface, any orientation is possible. 2. Mark the four fixing hole centres using the unit as a template. 3. Drill suitable holes into the substrate. Always use a fixing type and length suitable for the substrate, if in doubt ask your local fixing specialist for advice. 4. Support the unit and secure in place with the appropriate fixings. 482 265 8

Ducting Connections Titon recommend that: 1. 220x90mm ducting is primarily used for the connection of the extract port to the outside, reducing down to Ø150mm when breaching the external wall and connecting to a wall vent. Backdraught Damper External wall grille / vent to fit here Extract duct work from the unit to external grille / vent 2. Depending on the inlet configuration to the unit there are two options right angle & in-line; 90 option (Ø150 inlet port) connection is direct to the ceiling air intake grille. Ø150mm Inlet port direct to ceiling intake grille Right angle configuration In-line option (220x90mm inlet port) 220x90 ducting is used for connecting to an internal wall or ceiling air intake grille at a different location; where connecting to a ceiling grille a 90 elbow can be used, if connecting to an internal wall grille, such as a linear grille, the elbow is not required. Reducers can be used where required (as in 1.) if connecting to a Ø150 grille spigot, (grilles as specified by the system design). Inline wall option (elbow not required) Ceiling grille option In-line configuration 9

3. Ducting should be insulated where it passes through unheated areas and voids. 4. Unit should be insulated when fitted in unheated areas. 5. Where ducts extend externally above roof level the section above the roof should be insulated or a condensation trap should be fitted just below the roof level. 6. Where ducts pass through fire barriers they must be appropriately fire stopped in accordance with the requirements of Part B Building Regulations (England & Wales). 7. A ducting condensate drain must be fitted to vertical Extract Ports on outside duct work. 8. The condensate drain pipe work must be adequately secured, installed to have a minimum 5 fall and be insulated if any part of the pipe passes through an unheated void. Extract Port Power Cable Gland Commissioning Potentiometer 9. All insulation to be the equivalent of at least 25mm of insulating material with a thermal conductivity of 0.04 W/(mK). 10. Ducting must be installed in such a way that resistance to airflow is minimised. 11. Ducting connected from the Extract Port to the Outside must be to the external air outside the building envelope. 12. All ducting joints including those to this unit must be permanently connected and sealed. 10

Wiring Connection Access As the unit comes fitted with a flying lead no internal access is required to the unit when wiring it up. This unit should be fitted to a latching switch with mains power supply. If this unit is to be fitted with an optional Mains Actuated Backdraught Damper, as recommended by Titon to create a complete purge ventilation system, the Mains Actuated Backdraught Damper, should be wired into and operated by the same latching switch. Stand Alone This Purge Ventilation Unit unit to be fitted to a latching switch with mains power supply. 220-240V~ 50-60Hz L N 2 Pole Isolator 3A Fuse Remote Switch Supply lead from unit With Mains Actuated Backdraught Damper If the Purge Ventilation Unit is to be fitted as part of a complete system with the Mains Actuated Backdraught Damper the Titon Purge Ventilation Unit should be wired into and operated by the same latching switch. 220-240V~ 50-60Hz L N 2 Pole Isolator 3A Fuse Remote Switch Supply lead from Purge unit 2 Pole Isolator Supply lead from Damper unit 11

Commissioning TP625 The fan speed of the Purge Ventilation Unit will require adjustment to ensure that the flow rate is set correctly for the size of the habitable room it will be used in. The fan adjustment is made via a Rotary Potentiometer which can be found on the lid of the unit, a small flat head screwdriver will be required to make the adjustments. In Line Configuration Floor Area 4 Air Changes an Hour System Resistance (Pa) Fan Speed % *m2 l/s m3/hr 50 100 150 200 250 15 40 144 37% 45% 55% 63% 72% 20 53 191 45% 55% 63% 71% 73% 25 66 238 55% 63% 71% 73% 80% 30 80 288 63% 72% 75% 80% 90% 35 96 346 73% 77% 85% 100% 40 110 396 78% 87% 100% 45 120 432 100% 90 Configuration Floor Area 4 Air Changes an Hour System Resistance (Pa) Fan Speed % *m2 l/s m3/hr 50 100 150 200 250 15 40 144 32% 40% 47% 50% 62% 20 53 191 38% 45% 54% 60% 65% 25 66 238 45% 52% 58% 65% 68% 30 80 288 52% 58% 64% 70% 75% 35 96 346 60% 65% 70% 75% 40 110 396 66% 72% 76% 45 120 432 72% *assumed ceiling height 2.4m Hardware Reset Certain conditions (repeated supply interruptions etc.) can activate the automatic motor protection mode. Whereby the fan motors are prevented from operating. This requires a hardware reset to return the unit to normal operating mode, to achieve this power to the unit should be switched off for 5 minutes, restoring the power after this time will reset the hardware of both the motor and PCB. Commissioning settings are not affected during a hardware reset. 12

Routine Maintenance Maintenance All ventilation units require periodic maintenance. Routine maintenance must only be carried out by a suitably qualified and competent person. It is recommended that the Purge Ventilation Unit must be periodically cleaned internally. The maximum time between cleaning will depend on the local environment. Titon recommend the unit be cleaned every 2 3 years at a minimum. In the event of any queries please contact the system installer. WARNING: The unit uses a 220-240V~ 50-60Hz supply and contains rotating mechanical parts. ISOLATE the unit from mains power supply and allow sufficient time for all moving parts to stop before undergoing any Servicing or Maintenance. 13

Service Record Serviced By Company Date Notes 14

Serviced By Company Date Notes 15

In the event of any queries please contact the system installer. Ensure this booklet is passed to the householder once installation & commissioning of the ventilation system is complete. This Product Manual must be kept in the Home Information Pack and used as a service record. Installed by: MARKETING DIVISION 894 The Crescent, Colchester Business Park, Colchester, CO4 9YQ Tel: +44 (0) 1206 713800 Fax: +44 (0) 1206 543126 Email: ventsales@titon.co.uk Web: www.titon.com 2017 TITON DO 5529 Iss 01