PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

Similar documents
CABINET RANGES FOR AUTOMATED EXTERNAL DEFIBRILLATORS (AED)

Cold chain monitoring technologies. Facility monitoring

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

600 Range Dialer Installation Manual. Version 1.0

English. Doro CareIP Mobile. User Guide

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

Vehicle Tank Protection TANKSAVE. Fuel anti-theft system. Deters Warns

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

2G & 3G GSM Wireless Beam Alarm

SMS GSM Alarm Messenger

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

2G & 3G GSM Door Contact Alarm

MONECA SMART Smart card hydrant

your silent and loyal servant

System. For a better understanding of this product, please read this user manual thoroughly before using it.

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

IP & SMS Alarm Communicator

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Healthy. Atmosphere. for Pigs and Poultry. for a

SC-F3G User Manual 1.0

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

Med Touch Master Alarm

Description of the. controllers. Description of the. system extension possibilities. RS communication. Front panel made of glass. Control of 2 valves

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

Smart Wireless Sensor

NU2 Smart Power Supply (SPS) Manual

1. Functions of GPS locator ETLOC-30S 3

VIBRA-series: VIBRA, VIBRA +

A-MIP 210 Installation and user guide

GX-Cubic1 Smart Care Medical Alarm Solutionon. Caring for Your Health and Personal Safety


TD flex is an award-winning tailgate detection solution that prevents unauthorized access at: Doors Turnstiles Transfer gates Mantraps Airlocks

DATAssure. Laboratory wireless alarm & monitoring system

OPTIMUM APPLIED SYSTEMS,

2G & 3G GSM Portable PIR Alarm

GLOBAL. InstallatIon & operation manual

Smart Wireless Sensor

GSM RFID VOICE Alarm System

GSM PROTECT ANTI-THEFT ALARM WITH GPS TRACKING & MOBILE PHONE ALERTS

IntesisBox BACnet/IP Server - Notifier ID3000 series

Contents. Best Trusted and Rated Quality Products. PX-1 Stand-Alone Smoke Alarm. PX-1C Radiolink Smoke Alarm. PX-AR Alarm Relay

EASY THE SECURITY SYSTEM BUILT AROUND YOU

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

The WAVE Plus Instant Notification System for Schools and Colleges

Training 2 nd part. Agenda for second part

Now Compa ble With. VL Touchscreen Alarm. Crafted Touchscreen Security System that Revolutionizes Your World. illi tl C

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Home Automation. Product info. Marketed By: BlueSilica Technologies For further details write to

LevelSET S GSM Functionalities Instructions for Commissioning and Use

A-MIP 100 Installation and Operating Manual

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

GX-Cubic1 Smart Care Medical Alarm Solutionon. Caring for Your Health and Personal Safety

MyNice Welcome to your Nice World. The intelligent solution for the integrated management of the alarm system and of the home s automations.

A-MIP 200 Installation and Operating Manual

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

ENTOUCH ONE USER GUIDE


Affordable wireless monitoring without compromise

Section PERIMETER SECURITY SYSTEMS

Continuous, real-time detection, alarming and analysis of partial discharge events

INSTALLATION INSTRUCTIONS and BASIC SYSTEM CONFIGURATION

MOBILE CALL GSM Alarm System User s Manual

Manual GPRS Data Logger PCE-GPRS 2

Multi-Gas-Controller MGC2

EA-430 USER MANUAL. Version

Affordable wireless monitoring without compromise

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

WIRELESS ALARM SYSTEM CR200 >SMART GPRS INTRUSION DETECTION PLUG & PLAY FUNCTIONS SELF-LEARNING, SMART FEATURES TEXT ZONE NAMING

User Manual (LS-GSM-006)

Intellicomfort CH140GSM

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

arm wire free solutions nurse call personal security fire alarms

OJD ITB No Attachment E Duress Alarm Equipment Specifications

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

Access CONTROL. MANAGEMENT Software

Contents. Contents

JA-63 Profi User manual

TELECOMMUNICATION. Telecommunication. Wireless Phone

Dew point set DS 400

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

Tri-Tech Medical Inc.

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

EC-BOS-602/616 AX Security

Monitoring solutions

Wireless M2M Solutions

Contents. Most Trusted and Best Rated Quality Products. PX-1 Stand-Alone Smoke Alarm. PX-1C Radiolink Smoke Alarm.

AmpLight group management

Table of Contents 1. INTRODUCTION 1 2. PANEL INFORMATION 2 3. GETTING STARTED 5 4. CONNECTION TO PANEL WEBPAGE 9 5. DEVICE MANAGEMENT 11

PREVENTIVE PROTECTION PROTECCIÓN PREVENTIVA

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

THX-DL Data Logger USER & INSTALLATION MANUAL V

ThermoControl 0 C - 10 C - 20 C - 30 C

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

Building Automation solutions

Smart Security, Always Connected

1. User features of the GSM dialer

HRX Technical Manual. Version 1.2

Transcription:

PROTECTION CABINETS SUPERVISION CABINETS FOR AUTOMATIC EXTERNAL DEFIBRILLATORS (AEDs)

FEATURES OF AIVIA PROTECTION MODELS H : 423 mm The Aivia range has been designed and manufactured by the French company Pyrescom (ISO 9001 and 14001). All models are CE approved. Aivia models are robust and lightweight. They are made up of two distinct components ; A clear anti-uv treated polycarbonate cover. A green ABS stand, which complies with ISO 3864, International Standard concerning emergency colour codes. Unless they are intended solely for restricted access, cabinets are open access, protected by safety seals. L : 388 mm Weight: 3,5 kg W: 201 mm REGULATED HEATING AND FANNING SYSTEM MAINS POWER SUPPLY Enables AED unit to be stored in +0 C temperatures. Protects unit in -20 C extreme conditions. System activated through heat sensor according to configured thresholds or as preset by user. 24 V DC VLSV (very low safety voltage) LIGHTING AND ALARM SYSTEM BATTERY (AIVIA 100) Day/ Night lighting (sensor). Visual warnings (red flashing LEDs) to indicate malfunctions. Powered by 4 LR20 batteries included. For lighting and alarm systems. TELEPHONE WITH AUTOMATIC DOOR RELEASE BACKUP BATTERY Rechargeable which guarantee essential functions (Opening and telephone module) Analog hands free telephone module with the possibility of configuring two telephone numbers (with or without area code). Automatically calls the second telephone number if the first does not respond. Possibility of reducing telephone functions to avoid 'hoax calls' GSM TELEPHONE The costs of a SIM card and subscription to a mobile telephone network are to be borne by the client. * PYRESCOM RESTRICTED ACCESS OPENING Cabinet opens via digicode or vis RFID badge reader (AIVIA 210 and 230) or remotely via telephone (AIVIA 230). AUDIBLE ALARM SYSTEM Emits when the AIVIA cabinet is opened. From 70 to 105 db 1m, depending on the model.

Indoor models THE AIVIA PROTECTION RANGE Standard features Optional features AIVIA S AIVIA 100 Indoor/ Outdoor models For public safety reasons, the models below are powered by 24 Volts VLSV (Very Low Safety Voltage) AIVIA 200 AIVIA 210 AIVIA 220 REGULATORY COMPLIANCE AIVIA 230 EN 55022 : 2006 EN 55024 : 1998/A1 : 2001/A2 :2003 EN 60 950-1 : 2 006 + A11 : 2 009 Electromagnetic compatibility 2004/108/CE Low Voltage Directive 2006/95/CE Power requirement Minimale : 55 ma. Maximale : 2 400 ma (with heating) Protection index : IP54 Humidity index : 95% without condensation

FEATURES OF AIVIA SUPERVISION MODELS The AIVIA monitoring and supervision and AIVIA Protection ranges possess identical mechanical properties. They are linked to the AIVIAnet central database server via wired Ethernet, the Wifi or the 3G network. AIVIA monitoring and supervision models relay information to the AIVIAnet server regarding any events which may have occurred (if the AED cabinet is opened, in the case of temperature sensor malfunction, if the AED status indicator displays an error...) SUPERVISION AND MONITORING An optical sensor enables constant realtime monitoring of each protective cabinet and the AED they contain. Data concerning any alarms and alerts is immediately relayed to the AIVIAnet server. RFID BADGE READER For maintenance purposes and in the case of restricted access to the AED. THERMAL MIRROR The polycarbonate cover has received a particular finish in order to reduce the greenhouse effect. WIRELESS DATA COMMUNICATION Enables AIVIA protective cabinets to communicate with the AIVIAnet server rather than the Ethernet connection. The costs of a SIM card and subscription to a telephone provider are to be borne by the customer. WiFi Wireless communication. VoiP Voice over Internet Protocol- will require compatible switchboard software. PHOTO CONTROL CAMERA An infra-red lens which takes photographs when the cabinet is opened and the AED removed. Photos are sent to and stocked in the AIVIAnet server. See features of AIVIA Protection models

THE AIVIA SUPERVISION RANGE Fonctionalities AIVIA Supervision models ensure efficient realtime AED monitoring. Users (town halls, institutions, companies...) are therefore not obliged to organise the daily or weekly preventative maintenance visits otherwise recommended by the medical supervisory authorities. AIVIA Supervision models ensure total around the clock monitoring of AIVIA protective cabinets and the AEDs they contain. These models can be programmed to send automatic SMS or Email alerts to authorised personnel. Indoor and Outdoor Models For public safety reasons, the models below are powered by 24 Volts VLSV (very low safety voltage). AIVIA 300 AIVIA 310 Standard features Optional features AIVIA 320 REGULATORY COMPLIANCE AIVIA 330 EN 301 489-3 V1.4.1 : 2 002 EN 302 291-2 V1.1.1 : 2 005 EN 50 364 : 2 001 EN 60 950-1 : 2 006 + A11 : 2 009 Power requirement Minimale : 200 ma. Maximale : 3 000 ma (with heating) Protection index : IP54 Humidity index : 95% without condensation

AIVIAnet A software application for AED monitoring and assistance Restricted access via username/password Multilingual An AED dashboard Can be accessed via any computer connected to the web Record keeping of events Colour coding for alerts Indicator lights anticipate preventative action needing to be taken Statistical data retrieval (Excel retrieval tool) Displays photographs taken when the cabinet is opened and the AED unit removed Configuration of AED alert features (Email, text messages) Configuration of users/ user groups (RFID badge numbers) Geolocation of AIVIA cabinets

AIVIAtech Configuration software with an online diagnostics capacity for AIVIA Protection Range (2XX) and Supervision Range (3XX) CDigicodes for restricted access for both remote and manual opening Three possible telephone settings (pressing a call button, upon opening, upon removal of AED unit) The possibility of programming telephone numbers into the unit Configured thresholds for activating the heating and fanning systems and alert functions Volume and duration settings for the alarm Record keeping of past events Specific configuration for the AIVIA supervision and monitoring range is available : The type of network (LAN, 3G) LAN configuration : IP or DHCP addressing, if necessary proxy parameters 3G configuration : APN code, PIN number AED, serial numbers, pads, battery, batch numbers, expiry dates Location and geolocation data Calibration of the optical sensor used for monitoring units

CUSTOMISE YOUR AIVIA CABINET In addition to the optional features available for each AIVIA model, we offer our clients the possibility of customising their AIVIA units. The figure below shows the chain of survival in the case of sudden cardiac arrest and instructions on how to use the AIVIA cabinet. If they so desire, our clients are able to add a logo and additional text for greater visual impact. TWO STANDS ARE AVAILABLE Designed for both indoor and outdoor use, our BORNAVIE and COLAVIE stands fully comply with current legislation regarding street furniture. These are supplied with green epoxy paint RAL 6024 (the standard colour fully compliant with emergency colour coding ISO 3863). Other colours can be supplied on request. In accordance with ERC and ILCOR guidelines, all stands have been sprayed with the heart symbol and the wording 'AED' and 'DAE'. Other spray coating is available on request. AG3 5754H111 2mm aluminium tube frame with round and square sections. Comes with 8mm COLAVIE Aluminium base and reinforcement 3mm BORNAVIE Aluminium AG3 5754H111 2mm with 8mm base.. DIMENSIONS COLAVIE BORNAVIE Height : 1 639 cm Length : 395 cm Depth : 218 cm Weight : 13 kg A-MIP-DCAV-EN20120611 Height : 2 425 cm Length : 820 cm Depth : 260 cm Weight : 46 kg