CYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced.

Similar documents
Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

CBP - DOUBLE INLET FANS WITH FORWARD CURVED IMPELLERS

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

Inline mixed-flow fans with the air capacity up to 1850 m 3 /h

BATHROOM EXTRACT FANS SILENT-100 Series

Inline mixed-flow fans with the air capacity up to 450 m 3 /h

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK

Finned Tube Air Heaters Type WD/GG (RVS)

KOMFORT EC DB Suspended heat recovery air handling units

ROOFMASTER STEF-HT ROOF FAN

UNIJET CAR PARK VENTILATION SYSTEM

COR Series AIR CURTAINS. Air curtains. Dimensions (mm) Accessories. Technical characteristics

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

KITCHEN EXTRACTORS K Series

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

Offices. Conference halls. Kindergartens Libraries. Restaurants. Schools. Sport halls. Shops

Q (m3/h)

Air circulation. Xpelair air circulation products are able to provide for your fixed or spot cooling needs throughout the year.

SVK2 EX SVK2 SVV2 SVH2 ROOF FANS

EEDEN technical data ERHQ AA

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

CONDENSING UNITS AIR COOLED CONDENSER. COOLING ONLY

Remote Air Cooled Condensers C2 Series

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

High bay LED lighting fixture

Unit heater with accessories

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

Pure competence in air. NOVENCO BUILDING & INDUSTRY PRODUCT BROCHURE

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

0.4 m 3 /s. Plastic and Steel cased fan Units. Round Fans. Latest EC Fan Technology. Compact and Powerful. Easy to install

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

SINGLE PHASE RANGE BD BD 19/19 M4 1/5 BD 19/19 M6 1

FHHT 18 3 PHASE /32A / 400V ELECTRIC HEATER PRODUCT MANUAL P

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

Domestic & Commercial Fans

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Recessed. Air Curtain. Fig 1. Recessed air curtain

Practical Consideration of Noise from Fans

POWERPLUS SPP Product Brochure

NOVENCO BUILDING & INDUSTRY PRODUCTS. Products

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

Roof top SPACE RPC 450Z R407C M011

intarpack intarpack axial MDE / BDE series air-cooled condensing units High power in the smallest space. Tropicalised design for ambient temperature

Monitoring Pump Performance with Vibration. Mitchell Stansloski, PhD, PE

Axial fans The right fan for every house

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

EHH SERIES DRAW THROUGH FAN COILS CFM

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Application guide Installation, operating and maintenance manual AIRCUBE - KSCM/KSHM. Providing indoor climate comfort

Compact Horizontal Air-Air Heat Pump Model RTH 07L to 30L. Technical information. Ref.: N

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

technical data Fan coil unit FWB small duct unit

Technical Data Ducted Three Phase Split System Air Conditioner

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

High temperature air-to-water heat pumps

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

Selecting the Correct Fan

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Horizontal Split Case Pumps Type U

Fan Heaters Type VLEx

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

(57.7) X. March 2006 PRODUCTS. ... the complete solution

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Bruksanvisning Directions for use

TEMPORARY SPECIFICATION FOR REFERENCE

Novenco jet fans. AUO / ARO / AUT / ART / CGF January 2010

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

HasconWing. Fixed or variable airfoil profile axial impellers

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Industrial Ventilation

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

CRU 200 and 500 Series Condensate Recovery Units

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

ELFOEnergy Extended Inverter

Johnson Electric

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

Transformer oil coolers BETA & CETA

Transcription:

CYLINDRICAL CASED AXIAL FLOW FANS COMPACT Series TCBB (aluminium impellers) Range of cylindrical cased axial fans fitted with aluminium impellers and manufactured from high grade rolled galvanised steel and protect- ed against corrosion by cataforesis primer and black polyester paint finish. All models are supplied with pre-wired wiring junction box located on the outside of the fan casing for easy wiring access. Available, depending upon the model, with single phase motors with 4 poles. Motors All the motors are IP65 (1), Class F insulation (2), equipped with thermal protection. All motors are speed controllable by autotransformer except /4-560, /4-630, Electrical supplies: Single phase 230V-50Hz. (Capacitor located inside the wiring terminal box). (1) Working temperatures from -40ºC to 70ºC Additional Information Standard air direction: form (B) configuration (Impeller over Motor); A P P L I C A T I O N S Warehouses Workshops Commercial premises Car parks Corrosion resistance Terminal box Impeller dynamically balanced Rolled steel casings and motor support protected by cataforesis primer and black polyester paint finish. Stainless steel screws Wiring terminal box with cable gland PG-11 Impellers are dynamically balanced, according to ISO 1940 standard, giving vibration free operation 88

CYLINDRICAL CASED AXIAL FLOW FANS COMPACT series Cylindrical cased axial flow fans TCBB A P P L I C A T I O N S Warehouses Workshops Commercial premises Car rks Corrosion resistance Terminal box Impeller dynamically balanced Rolled steel casings and motor support protected by cataforesis primer and black polyester paint finish. Stainless steel screws Wiring terminal box with cable gland PG-11 Impellers are dynamically balanced, according to ISO 1940 standard, giving vibration free operation 89

Supply voltages and frequencies Mains supply Motor type Connection Speed voltage SINGLE PHASE 230V 50Hz See wiring 230V 50Hz diagram Single Acoustic characteristics The sound levels NPS- shown in the technical characteristic chart, correspond to the value of sound pressure db(a), measured in free field conditions at a distance equivalent to three times the diameter of the impeller with a minimum of 1.5 meters. Sound power level spectrum in db(a) at the corresponding octave band average frequencies in Hz. LwA ASP QMAX 63 125 250 500 1000 2000 4000 8000 4-250/H 44 50 57 58 60 59 53 4 2 4-315/H 37 47 57 61 66 63 57 4 8 4-355/H 39 59 56 65 70 66 61 5 2 4-400/H 41 62 58 67 74 70 66 4 3 4-450/H 41 57 60 69 73 71 65 5 5 4-500/H 44 61 64 73 76 75 68 5 9 4-560/L 44 60 66 75 78 76 71 6 2 4-560/H 46 61 67 76 80 78 72 6 4 4-630/L 46 60 69 78 82 80 75 67 90

Technical characteristics for models with ALUMINIUM impellers Before installation check that the product electrical characteristics listed on the data plate label (Voltage, power, frequency etc) match those of the intended electrical supply. Explosion proof types only work at an ambient temperature between -30ºC and +40ºC. Model Speed (r.p.m.) Maximum power absorbed (W) at 230 V Maximum current (A) SINGLE PHASE 4 POLES Sound pressure level (db(a)) Maximum air volume TCBB/4-250/H 1330 60 0,3 52 1250 8,0 TCBB/4-315/H 1300 100 0,6 54 2340 11,0 TCBB/4-355/H 1225 200 1,0 58 3470 13,2 TCBB/4-400/H 1200 340 1,6 60 5100 15,5 TCBB/4-450/H 1370 620 2,7 62 7100 21,0 TCBB/4-500/H 1300 800 3,5 66 9710 25,0 TCBB/4-560/L 1300 1240 5,8 67 11750 33,0 TCBB/4-560/H 1340 1680 7,7 69 13780 34,7 TCBB/4-630/L 1280 1800 8,4 70 16100 40,0 (m 3 /h) Weight (kg) Speed* controller Cylindrical cased axial flow fans TCBB Three phase speed controllers (RMT) or inverter controller (VFKB/VFTM) 91

Dimensions (mm) Number Model Ø A Ø B C Ø D Ø E of holes N 250 327 292 170 254 10 4 315 386 355 170 315 10 8 355 426 395 170 355 10 8 400 487 450 170 400 12 8 450 537 500 180 450 12 8 500 595 560 180 500 12 12 560 655 620 240 560 12 12 630 725 690 240 630 12 12

Performance curves - Series TCBB Q = Air volume in, m 3 /hr and m 3 /s. Pe = Static pressure in mmwg and. Dry air at 20ºC and 760 mmhg. Air flow data in accordance with the following standards: UNE 100-212-89, BS 848, rt 1; AMCA 210-85 and ASHRAE 51-1985. Performance curve characteristics for the Compact cased axial fans with plastic impellers (TCFB/T) correspond with the curves illustrated for the Compact Plate Axial fans (pages 65 to 67). Typical fan selection: Do not select the working point in the coloured area. To find the working point it is first necessary to plot the system resistance curve. The working point lies at the intersection between that curve and the fan performance curve. Example: Required air volume 13.100 m 3 /h at 18 mmwg Fan working point 14.150 m 3 /h at 21 mmwg mm WG Do Not Select a Fan with a Working Point in this Area Required Air Volume System Resistance Curve Working Point of Fan Pe mmwg 4 pole - 250-315 - 355-400 Pe mmwg 4 pole - 450-500 - 560 96