Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

Similar documents
WHHR Midi & Midi Lite

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

"Microbox" Continuous Mechanical Extract Ventilation Units. Installation, Operating and Maintenance Instructions

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

low energy environmentally friendly economical residential ventilation with EC motors June 2015 Issue 5

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

HOTLINE:

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Installation and Maintenance

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

Building Regulations 2010: What it means to you.

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

Installation and Maintenance

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Installation and Maintenance

Installation and Maintenance

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Triton Systems Anti-Condensation Products Data Pack

Installation and Maintenance

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

Mechanical Ventilation with Heat Recovery: Designing and implementing a robust and effective ventilation system

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

MODEL: BV400 Part No:

Installation and Maintenance

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Lo-Carbon Sentinel Kinetic Horizontal

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

VENTILATION DESIGNED FOR CARE HOMES

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

CI/SfB (57.7) 1st edition

Installation and Maintenance

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

HOTLINE:

Domestic & Commercial Fans

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

Warnings, Safety Information and Guidance

ECO dmev Decentralised MEV

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

Thank you for choosing EnviroVent

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Lo-Carbon Quadra SELV

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery

Energy Efficient Air Distribution Systems

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Polypipe Ventilation Specifiers Guide

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Lo-Carbon Quadra Centrifugal Fan

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

Xcell 270 Longlife DC wholehouse heat recovery unit

EVP61/91/101/121. Extractor. Installation, use and maintenance.

CVE ECO 2 Range. System Brochure Continuous Mechanical Extract Ventilation Appendix Q Eligible

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Ventilation & Heat Recovery. The whole house system from OMNIE

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

Air Flow Solutions. A Guide to Specifing and Installing Residential Ventilation

MRXBOX95AB-WH2 (with automatic summer bypass)

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Centrif Duo & Centrif Duo Plus

ECo 2 Wall USER GUIDE FOR RESIDENT

HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions

Thank you for choosing EnviroVent

BUILDING STANDARDS SUPPORTING GUIDANCE DOMESTIC VENTILATION

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

G Installation manual Solitude - dmev unit

Transcription:

Residential Carbon Friendly Ventilation SAP Q Eligible ventilation

Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation About Appendix Q SAP is the Government's Standard Assessment Procedure for Energy Rating of Dwellings and was adopted as part of the UK national methodology for calculation of the energy performance of buildings. It is used to demonstrate compliance with building regulations for dwellings - Part L (England and Wales), Section 6 (Scotland) and Part F (Northern Ireland) - and to provide energy ratings for dwellings. Appendix Q was introduced to promote energy efficient ventilation products which offer benefits in SAP and DER (Dwelling Emission Rate) calculations. Products are tested (by BRE) to provide a specific fan power performance and heat exchange efficiency which can then be used to calculate energy saving. The Appendix Q process gives prominence to the most efficient ventilation products and offers recognition for improved performances. Products which are listed (SAP Q Eligible) have met the stringent criteria of the testing processes resulting in products which can be depended on to provide proper ventilation whilst complying with all the current Building Regulations requirements. SAP Q Eligible products also offer the best energy efficiency and performance at the lowest carbon output, and, at the same time, help to protect the environment both inside and out. Vectaire's range of SAP Q Eligible products utilise the latest, innovative technologies to ensure that all the environmental criteria are met, whilst providing ventilation of a style and capacity to maintain a comfortable environment and a good level of air quality inside the home. Tel: +44(0)1494 522333 Fax: +44(0)1494 522337 Page 2 Email: sales@vectaire.co.uk Web: www.vectaire.co.uk

Whole House Mechanical Ventilation - MVHR, MEV, dmev SAP Q ELIGIBLE PRODUCTS Energy Efficient Ventilation Which Products to Choose Pollution in the home has been identified as a contributory factor in the rise of respiratory and allergy problems. Too little ventilation causes excessive condensation which leads to dampness, mould growth, a musty smell and a general deterioration of the fabric of the building. Too much ventilation will lead to increased running costs, physical discomfort for the occupants (as well as harming the environment by the excessive use of energy). The answer lies in well thought out, efficient ventilation, with low noise levels and running costs. "WHHR100/90DC-B" (MVHR) Whole house ventilation unit with heat recovery: DC motor for high efficiency low energy usage. Suitable for installation in homes and offices recovering 92% of heat from extracted, polluted air. Continuous running with choice of trickle and boost speeds. "WHHR125DC - Aera" (MVHR) Whole house ventilation unit with heat recovery: DC motor for high efficiency low energy usage. Suitable for installation in homes and offices recovering up to 93% of heat from extracted, polluted air. Continuous running with choice of trickle and boost speeds. "MBOX125/2DC-B" (MEV) Slimline whole house mechanical extract ventilation unit for homes or offices with energy saving DC motor, giving continuous ventilation with a choice of trickle speeds and allowing user to boost capacity when necessary. "E-Smile" (Decentralised MEV) High performance, low energy, 3 speed fan for installation in all domestic wet rooms. It runs continuously at a preselectable level (depending on siting) allowing user to boost to maximum performance when required. Tel: +44(0)1494 522333 Fax: +44(0)1494 522337 Page 3 Email: sales@vectaire.co.uk Web: www.vectaire.co.uk

Whole House Mechanical Ventilation with Heat Recovery - MVHR WHHR100/60DC This MVHR - WHHR100/60DC - is an efficient, slimline, low energy solution to controlling condensation and pollution. It provides low level continuous ventilation in a kitchen and up to six wet rooms, extracting moist, polluted air and replacing it with fresh, filtered air - recovering up to 64% of the heat from the outgoing flow. The user can to boost to maximum performance when required. The WHHR100/60DC is easily installed in the loft or roof void, or a cupboard The noise level and running costs are extremely low, and it is compliant with Parts L and F of the Building Regulations Tel: +44(0)1494 522333 Fax: +44(0)1494 522337 Page 16 Email: sales@vectaire.co.uk Web: www.vectaire.co.uk

Whole House Mechanical Ventilation with Heat Recovery - MVHR WHHR100/60DC Technical Characteristics FEATURES SAP Q eligible (MVHR) residential whole house heat recovery unit for providing continuous ventilation in kitchen and up to 6 additional wet rooms maximum airflow 94 l/sec suitable for areas up to 260m 2 up to 64% of heat recovered from stale air extracted from warm, moist rooms replacing it with fresh, filtered, warmed air to create a constant, comfortable, healthy environment easy to install and maintain for fitting into lofts, voids, false ceilings or cupboards variable choice of low (trickle) speed and boost options for optimum setting at installation the boost speed can be triggered by a switched live connection from a range of devices: - PIRFF (passive infra red)* - DRH240 (dynamic remote humidistat)* - THM (thermostat)* - a light switch (if more than one light switch is used, each one must be a double pole switch) - a remote switch/pull cord (*PIRFF, DRH240 and THM may have integral over-run timer which controls the length of time that the fan will continue to operate at its boost speed after the boost has been switched off.) low noise levels low running costs gives extra security by removing need to open windows 3 year warranty Vectaire Ltd can supply all accessories for use with these units, including air filter cassettes, silencers, fire dampers, air valves, ducting, outside grilles and wall cowls SPECIFICATION compact, low profile unit - only 200mm deep casing manufactured from galvanised sheet with an epoxy finish thermo-acoustic lining in polypropylene to prevent thermal bridging to outside low energy DC brushless motor for optimum combination of high performance, low noise levels and low energy consumption impellers are single width, single inlet, direct drive and backward curved for higher efficiency pre-wired for easy electrical connection operates in temperatures up to 60ºC uses standard, disposable G3 filters cross flow heat exchanger for greater efficiency and increased separation of airflows Vectaire Ltd offers a design service to ensure that the unit installed is the best possible to provide efficient, effective, low energy and low running cost ventilation. Vectaire can also organise installation and commissioning of these products LOFT OR VOID INSTALLATION Incoming fresh air Warmed fresh air Extracted warm, moist, stale air Cooled outgoing stale air WHHR100/90DC COMPLIES WITH Part L1A and L1B of Building Regulations for enhanced energy saving capability Part F of Building Regulations for reliable, efficient ventilation manufactured to BS EN ISO 9001 complies with IEC 60335-2-80, LVD2006/95/CE and EMC 2004/108/CE European Directive against radio interference and electro-magnetic compatibility CE marked SAP Q eligible Tel: +44(0)1494 522333 Fax: +44(0)1494 522337 Page 17 Email: sales@vectaire.co.uk Web: www.vectaire.co.uk

Whole House Mechanical Ventilation with Heat Recovery - MVHR WHHR100/60DC Technical Characteristics - SAP Results RESULTS for SAP CALCULATIONS ENERGY LEVEL PERFORMANCE - using rigid ducting only Exhaust Terminal Configuration Fan Speed Setting Specific Fan Power (W/l/s) Heat Exchange Efficiency (%) Kitchen + 1 additional wet room 100% variable 0.73 64 Kitchen + 2 additional wet rooms 100% variable 0.70 61 Kitchen + 3 additional wet rooms 100% variable 0.74 59 Kitchen + 4 additional wet rooms 100% variable 0.80 55 Kitchen + 5 additional wet rooms 100% variable 0.94 54 Kitchen + 6 additional wet rooms 100% variable 1.08 52 Figures from BRE test results RESULTS for Approved Document F Exhaust Terminal Configuration Fan Speed Setting Total Exhaust Flow Rate (l/sec) Total Supply Flow Rate (l/sec) Kitchen + 1 additional wet room 100% variable 15.0 15.0 Kitchen + 2 additional wet rooms 100% variable 21.0 21.0 Kitchen + 3 additional wet rooms 100% variable 27.0 27.0 Kitchen + 4 additional wet rooms 100% variable 33.0 33.0 Kitchen + 5 additional wet rooms 100% variable 39.0 39.0 Kitchen + 6 additional wet rooms 100% variable 45.0 45.0 Figures from BRE test results Tel: +44(0)1494 522333 Fax: +44(0)1494 522337 Page 18 Email: sales@vectaire.co.uk Web: www.vectaire.co.uk

Whole House Mechanical Ventilation with Heat Recovery - MVHR WHHR100/60DC Technical Characteristics - Performance & Dimensions curves are for guidance only 200 180 160 140 Speed Watts db(a) @ 3m Max Speed 104 42 7 73 40 6 53 37 5 39 34 4 28 31 3 21 27 2 15 22 1 11 16 Available Pressure Pa 120 100 80 60 40 20 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 litres/second Dimensions (mm) Tel: +44(0)1494 522333 Fax: +44(0)1494 522337 Page 19 Email: sales@vectaire.co.uk Web: www.vectaire.co.uk

Other Vectaire SAP Q Eligible Products WHHR125DC WHHRC180DC WHHR150DC WHHRM300DC can be installed over cooker hood also available with summer by-pass WHHR250DC WHHR400DC can be installed over cooker hood also available with summer by-pass Vectaire Ltd Lincoln Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel: +44(0)1494 522333 Fax: +44(0)1494 522337 Email: sales@vectaire.co.uk Web: www.vectaire.co.uk Vectaire Ltd reserves the right to alter specifications as part of its policy of continuous development July2011/SAP Eligible products E & O.E

"WHHR100/60DC" Whole House Heat Recovery Unit with Low Energy DC Motor - for domestic and commercial use Installation, Operating and Maintenance Instructions

Page 2 "WHHR100/60DC" - WHOLE HOUSE HEAT RECOVERY UNITS INSTALLATION AND OPERATING INSTRUCTIONS Safety Notice It is important to read this Instruction Manual carefully before installing or using the product. Following these instructions will ensure that your ventilation system is installed, commissioned and used properly and continues to operate effectively. Vectaire will not be held responsible and will not accept liability for any damage caused to persons or property through failure to follow the guidance provided in this manual. It should always be available with the product for easy reference. Your unit SHOULD NOT be switched off. It is designed to run continuously. If it is switched off indoor pollutant and moisture levels may increase. WHHR100/60DC: 5"/125mm spigot, for dwellings up to 260m 2, max capacity 94 l/sec General Information The Vectaire WHHR100/60DC heat recovery system provides whole house mechanical ventilation to living areas, bedrooms, kitchen and bathrooms. They extract stale, contaminated air from kitchens, utility rooms and bathrooms, and use the heat recovered from this air to warm fresh, incoming air to create a flow of fresh air throughout the dwelling. The extract and intake air streams are separated to avoid contamination. Heat is reclaimed from extracted air and used, via the heat exchanger, to warm incoming fresh air. The system will operate continuously to create a stable, comfortable, healthy environment avoiding the use of excessive energy and saving heat already generated. The heat recovery unit will generally be installed in the loft of a house or the void above the ceiling in an apartment (but may be installed in a cupboard) and will be connected by hidden ductwork to vents sited in the ceilings of the rooms which require ventilation. Each unit is commissioned individually allowing its performance to be tailored to suit the performance required. There will be a facility to boost the extraction rate when desired (e.g when cooking or bathing or pollutant levels rise). This may be done automatically or manually. The system is designed to run continuously and should NOT be switched off except for maintenance or filter replacement. Features SAP Q Eligible whole house heat recovery units giving continuous ventilation in the kitchen and up to six additional wet rooms low noise levels variable choice low (trickle) speed and boost options for optimum setting at installation boost speed can be triggered by a switched live connection from a variety of external devices including: - PIRFF (passive infra red)* - DRH240 (dynamic remote humidistat)* - THM (thermostat)* - a light switch (if more than one light switch is used, each one must be a double pole switch) - a remote switch/pull cord (*PIRFF, DRH240 and THM may have integral over-run timer which controls the length of time that the fan will continue to operate at its boost speed after the boost has been switched off.) Installation MUST be carried out by suitably qualified personnel and MUST be in accordance with current IEE regulations and all appropriate standards and applicable regulatory guidance.

Page 3 WHHR100/60DC Installation IT IS IMPORTANT THESE THESE INSTRUCTIONS ARE READ FULLY BEFORE INSTALLATION This product should not be used for any purpose other than that for which it was designed and as shown in this leaflet. All packaging should be removed and the unit checked for damage in transit. If there is any damage, please contact your supplier The WHHR 100/60DC will generally be fitted into a loft or ceiling void. In order to comply with Construction (Design & Management) Regulations, sufficient access for safe maintenance (recommended on an annual basis), or removal following installation, MUST be provided for this product. See dimensions above. Fire Dampers must be fitted to duct work at appropriate locations in accordance with Building Regulations Flue gases from fuel-burning equipment must not be drawn into a living area. If any room from which air is extracted contains a fuel burning appliance, such as a central heating boiler, then its flue must be of the sealed or balanced flue type, or allowance must be made for an adequate supply of air into the room. The unit must NOT be be installed: - where there is excessive oil or grease - where there are hazardous gases, liquids or vapours that are flammable or corrosive - in ambient temperatures above 50ºC or lower than 5ºC - in humidity levels above 90% or in a wet environment Where possible the unit should NOT be installed directly above a bedroom or living room. The condensation drain must be fitted, and if insulated use the equivalent of at least 25mm of insulating material with a thermal conductivity of 0.04 W/(mK) Care should be taken to ensure that ducting is free from blockages before switching on the unit as this may invalidate your guarantee External grilles should be located a minimum of 600mm from any flue outlet in accordance with all Regulations The unit must be connected to a 230v, 50Hz single phase electrical supply fused at 3A. A fused spur box, or triple pole switch having a minimum contact separation of 3mm must be used for isolation. The product should only be connected to the mains electricity supply or electrical outlet if: - your electrical voltage and frequency correspond to those shown on the rating label. - the capacity of your electricity supply is sufficiently powerful to operate the product at its maximum power. If one of the spigots is not connected to ducting a safety grille MUST be fitted to that spigot, so that it is impossible for any moving part to be touched. This appliance is not suitable for installation on the outside of a building Installation of the appliance MUST be carried out by a qualified and suitably competent person and should be carried out in clean, dry conditions where dust and humidity are at minimal levels. It should only be installed after other building works have been completed and the building in which it is installed cleaned. Failure to comply with any of the above points will have an impact on the validity of the guarantee.

Page 4 Duct and Duct Connections (refer to design drawing) 4 x 125mm nominal diameter spigots are provided for the connection of ducting. These are clearly marked for correct connection of the supply and exhaust ducts. Flexible duct fits over the spigots, whilst rigid duct fits into the spigots. Where ducts are exposed in unheated areas, they should be insulated (except for the exhaust duct from the unit to the atmosphere), The duct layout must be designed to suit the requirements of the ventilation/recovery system and building lay out. If the ducting passes through a fire wall/barrier, suitable fire dampers must be installed. Where rigid duct is used, it should be installed using the least number of fittings to minimise air flow resist ance. Where possible, final connection to the grilles and unit should be made with a flexible connection. Where flexible ducts are used, ensure that: - duct runs are kept as short as possible - the duct is stretched so that it is smooth and straight - where bends are necessary, they have large radii (ie avoid sharp bends) - the duct is not crushed if in a restricted area The inlet for the fresh air supply can be directly from outside, or from within a ventilated roof space. If the sup ply is directly from outside, it must have an external wall grille fitted if supplied through a wall, or a recognised roof terminal if supplied through a roof. If the supply is from a ventilated roof space, it must be protected by a filter box. Condensation (the unit may sometimes produce condensation which must be drained away. A 15mm dia pipe connection is provided on this unit). A 15mm dia pipe must be fitted to the pipe connection. If any part of the condensate drain is in an unheated space it MUST be insulated with the equivalent of at least 25mm of insulating material with a thermal conductivity of 0.04 W/(mK). The drain must incorporate a U-bend to prevent air penetration. The pipe must drain into the normal household drainage system. The unit must be tilted towards the side carryng the condensation exit point. It should be installed horizontally with a 3º tilt towards the condensation drain used (equivalent of raising the opposite end by approximately 25mm).. Four possible condensation drain points are provided, which allow the installer to turn the unit through 180 O to simplify duct layout and connections. Electrical Connection WARNING: these appliances must be earthed and all wiring must conform to current IEE Regulations and all applicable standards and Building Regulations. The unit is suitable for 230V, 50Hz Single phase supply fused at 3A. The unit is supplied with a mains rated 4 core flexible cord (black, brown, grey and green/yellow) A triple pole isolation switch with contact separation of at least 3mm must be used to connect the appliance to the fixed wiring when using the Switched Live. Boost controls must not be located within 1 metre of a cooker or where they may be affected by excessive heat or moisture Boost controls should be clearly identified and conveniently located. The boost switch wiring cable access is via a 12mm cable gland. The boost speed can be triggered by a switched live connection from a variety of external devices including: - PIRFF (passive infra red)* - DRH240 (dynamic remote humidistat)* - THM (thermostat)* - a light switch (if more than one light switch is used, each one must be a double pole switch) - a remote switch/pull cord (*PIRFF, DRH240 and THM may have integral over-run timer which controls the length of time that the fan will continue to operate at its boost speed after the boost has been switched off.)

Page 5 Commissioning The units operate by extracting warm, stale air from kitchens, WCs, bathrooms etc, and passing it into a heat exchanger and out to the atmosphere. Another fan draws in cool, fresh air and passes it through the same heat exchanger, where it is heated by the outgoing, stale air. When the unit is set up and running, the minimum setting on the speed control switch must relate to the designed volume air flow. The variable air flow from minimum to maximum allows the unit to extract a greater volume to cope with any increase in the build up of condensation or foul air, ie cooking etc. Before starting the commissioning procedure, refer to the design drawing for correct air flows. N.B extract and supply air volumes will not always be equal. When setting up, therefore, the extract system should be the datum. Installation of the appliance MUST be carried out by a qualified and suitably competent person and should be carried out in clean, dry conditions where dust and humidity are at minimal levels. It should only be installed after other building works have been completed and the building in which it is installed cleaned. Failure to comply with any of the above points will have an impact on the validity of the guarantee. Commissioning Procedure Ensure that the exhaust and supply grilles or valves are open. Turn the electrical supply ON and set the fan speed control to TRICKLE. Check the air flows at the grilles or valves, and adjust to suit the design figures by turning the centre of the valve clockwise to decrease the airflow, and anticlockwise to increase the airflow. If the airflow is still not correct proceed as follows: - turn the electrical supply OFF - remove the electrical access cover - locate the trickle speed adjustment (see Wiring Diagrams) and adjust as required. - turn the electrical supply ON. Re-measure the air flows at the grilles or valves as detailed above, and repeat the procedure until the correct air flows are achieved. Adjust the Boost Speed to requirement and ensure that the air flows increase when the boost switch is acti vated. Cleaning and Maintenance WARNING: The unit uses a 230V supply and contains rotating mechanical parts. Before carrying out any maintenance or cleaning operations the mains electrical supply MUST be disconnected. The air filters and heat exchanger of the Vectaire WHHR100/60DC should be cleaned regularly by a suitably qualified person (the frequency of cleaning will vary depending on the installation environment). Filters should be replaced after a maximum of 3 cleaning cycles. Filter and Heat Exchanger access: Remove the centre screw and the four corner screws located on the larger access panel Completely remove the panel To clean the filters and heat exchanger: Remove the access panel Slide out the filters that are fitted either side of the heat exchanger as shown. Clean the filters carefully using a vacuum cleaner. Carefully remove any dust from the face of the heat exchanger using a vacuum cleaner. Never use water or any other fluids to clean the heat exchanger. Return the heat exchanger and filters to their original position. Replace the front cover and ensure it is securely located at the top before tightening all screws. Power to the unit can now be restored. Filter Replacement Filters should be replaced annually or after a maximum of 3 cleaning cycles. Replacement filters are available from Vectaire - call us on +44 (0) 1494 522333 or via sales@vectaire.co.uk

Page 6 WHHR100/60DCFeb 2011 Vectaire Ltd, Lincoln Road, Cressex Business Park, High Wycombe, Buckinghamshire, HP12 3RH Tel: +44 (0)1494 522333. Fax: +44 (0)1494 522337. Email: sales@vectaire.co.uk E & O.E