OPERATION GUIDE MODEL CERV-001-PARTA, CERV-001-PARTB CONDITIONING ENERGY RECOVERY VENTILATOR (CERV)

Similar documents
OPERATION GUIDE MODEL CERV-001-PARTA, CERV-001-PARTB CONDITIONING ENERGY RECOVERY VENTILATOR (CERV)

CERV WIRELESS TOUCHSCREEN CONTROLLER USER S MANUAL BUILD EQUINOX REVISION N. HIGH CROSS RD. URBANA, IL

INSTALLATION MANUAL CONDITIONING ENERGY RECOVERY VENTILATOR (CERV) MODEL CERV-001-PARTA, CERV-001-PARTB

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/Dehumidification Devices on the US Market

MAINTAINING A HEALTHY, COMFORTABLE, INDOOR ENVIRONMENT

In Search of the Magic Box: A Review of Crossover Conditioning/Ventilation/ Dehumidification Devices on the US Market

Daikin ENVi Thermostat installation overview

Siemens Thermostats. RDY2000BN Thermostat

Indoor Air Quality Product Brochure.

A Necessity for Preventing Unsafe Backdrafts and Unhealthy Air

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

The ultimate fresh air solution.

Air Conditioning Refrigeration Electrical Work TEL: 0(204) (254)

Verasys System Operation Overview Technical Bulletin

Indoor Air Quality Product Brochure.

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

Fresh Air Solutions Whole-Home Ventilation

Comfort Series. Energy Recovery Ventilator. Why Fresh Air Ventilation is Vital for Today s Energy-Efficient Homes

Outside Air Requirements... SOLVED!

Put the V back in HVAC

OPERATING INSTRUCTIONS

OVEN INDUSTRIES, INC.

Advanced Installation and Configuration Instructions

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

TR Series - The Ultimate ERV

READ AND SAVE THESE INSTRUCTIONS

Home WHOLE-HOME COMFORT SOLUTIONS. Bringing balance. Creating comfort.

HEALTH. Particles. Chemicals

USER GUIDE HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V AND 60H NOVO+, MODEL ERV 90H-V ECM PLEASE READ AND SAVE THESE INSTRUCTIONS

b.) Technical Information:

General HVAC Recommendations

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

IntelliSync Thermostat / Mobile App Frequently Asked Questions

L CONNECTION NETWORK Commercial Controls

MiniCore Ventilator (500, 1000) Series Engineering Guide

Ammonia Detection System Codes and Design Specifications

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

LEED for Homes Points

Emerson Blue Easy Set 1H/1C

Residential Heat & Energy Recovery

VIGÖR HRV PLUS AND VIGÖR ERV

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Troubleshooting the Indoor AHU as a Standard Product

Do More With Less

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

Hydronic & HVAC Control Systems

1F98EZ-1421, Easy Install

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

User s Manual. THE iq Drive SYSTEM USER S INFORMATION IMPORTANT. Variable Speed Ultra-High SEER Split System IMPORTANT NOTE

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

KTIR AIR CONDITIONER SERIES TROUBLESHOOTING

RCS Residential Control Systems Inc.

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

TEC Controller Single Compressor Heat Pump with Reversing Valve Control, Application Application Note Building Technologies

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

WE ARE CONTINUOUSLY ADDING TO AND IMPROVING OUR INDOOR AIR QUALITY PRODUCTS TO PROTECT YOUR FAMILY S HEALTH.

Air Comfort. Installation instructions (English) A

TEC Controller Heating & Cooling Heat Pump with Internal Reversing Valve & Mixed Air Control, Application 2072

Variable Refrigeration Flow Systems Overview 10/11/2016

ATTACHMENT D #1 - HVAC (OIL) - SINGLE FAMILY DWELLINGS Category C: OIL

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2012 Supersedes

The best way to enhance indoor air quality

Temperature Relative Humidity

HVAC for Raters & Inspectors

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

EL-TSTAT-8820 Safety & Installation Instructions

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

Synergy3 Owner s Manual. Owner s Manual. Geothermal Heating Cooling Hot Water

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Better Design, Better Control, Better Systems.

ENERGY RECOVERY VENTILATOR

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

TEC Controller Multiple Compressor Heat Pump with Reversing Valve & Mixed Air Control, Application Application Note

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Job Name Control Systems Description Date

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

HAI Omni-Bus Network Installation. 5. Typical Application

AirTrak. Digital Control System. User Manual. Touchscreen Systems

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

Booster Fan Ducting Kit Installation Instruction for Hybrid Electric Heat Pump Water Heaters

LIGHT COMMERCIAL Heat and Energy Recovery Ventilators

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

- Data Brochure Boiler Control 274

SYST0101CW Product Specifications

RC-2000 Thermostat Installation Instructions

Product Data. Features/Benefits. 33CS Carrier Comfort System Variable Volume and Temperature (VVT )

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE.

Air Conditioning and process cooling Energy Components at a Glance

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

Transcription:

OPERATION GUIDE MODEL CERV-001-PARTA, CERV-001-PARTB CONDITIONING ENERGY RECOVERY VENTILATOR (CERV) BUILD EQUINOX SUPPORT@BUILDEQUINOX.COM (773)-492-1893 REV 0.50-06/16/2016

Contents Overview... 4 CERV Modules... 5 Conditioning Module (PART-A)... 5 Fresh Air Control Module (PART-B)... 5 Other Components... 6 Inline ECM Supply & Exhaust Fans... 6 Wireless Touchscreen Controller... 6 Optional Auxiliary Duct Heater... 6 Optional Wireless Ventilation Switches... 6 Operation Modes... 7 Modes Ventilation... 7 Modes Recirculation... 8 Modes Heating / Cooling... 8 Modes Off... 8 Energy Recovery... 9

OVERVIEW Managing a home's air quality is a demanding job. Between the resident's preferences, the occupancy activity, and the time of year, your home's fresh air ventilation system needs to be flexible enough to handle a dinner party, while being smart enough to know when to cut back and save energy if fresh air is not needed. Build Equinox's CERV is precisely that kind of system. Designed from the ground up to serve you, the CERV's primary mission is to ensure that your home is both healthy and comfortable in a highly energy efficient manner. Most Energy Recovery Ventilators (ERVs) and Heat Recovery Ventilators (HRVs) simply have a fixed ventilation rate for your home, regardless of your occupancy level. Gone for the day? Your ERV/HRV chugging away, needlessly ventilating your home and placing an unnecessary load on your conditioning system. Maybe now you have a few friends over, or you are exercising. Your pollutant level is going to rise, and your fixed ERV/HRV is just going to be sitting there, oblivious to the fact that the home is in desperate need of some fresh air. Not the CERV. The brains of the CERV lie in the Fresh Air Control Module. By constantly monitoring the home's inside and outside temperature, relative humidity, Carbon Dioxide (CO2), and Volatile Organic Compound (VOC) levels, the CERV is able to always maintain a high level of air quality and comfort in the most efficient way. Gone for the day? No problem, the CERV automatically sees the CO2 and VOC levels dropping, and decreases its ventilation rates accordingly. Having friends over? CO2 and VOC levels increase, indicating to the CERV that you need more ventilation. The CERV can take a sizeable load off of the home's conditioning system as well with its conditioning module. Instead of using a typical heat exchanger core, the CERV exchanges energy through air streams with the use of its heat pump, which can actively heat or cool the air if it sees that the house is out of your desired comfort range. This document is meant as a guide, to help you understand what the CERV is, and how it functions to keep your home a healthy and comfortable living environment. Revision 0.50 [06/16/2016] Page 4

CERV MODULES CONDITIONING MODULE (PART-A) Fresh air conditioning and Energy Recovery are both accomplished through the use of the Heat Pump Conditioning Module. This module heats, cools, dehumidifies, and exchanges energy efficiently and quietly, utilizing high quality, long lasting components. The bottom half of the conditioning module contains both the Compressor and the Condenser, which heats the passing air to be supplied inside or exhausted out. At the same time, the top half of the module contains the evaporator, which cools and dehumidifies the passing air to be rejected outside or supplied inside. The refrigeration system is made from high quality appliance components and is a fully sealed system (meaning there are no refrigerant lines to run). Due to the small size of the system, the compressor operates practically without noise. Please see the Operation Modes section below for more information on how this incorporates into the whole system. On the outside of the unit, you will also notice the electrical junction box, which contains the power supply wiring and low voltage frequency input, as well as a threaded PVC drain pipe and white nylon overflow tube. The PVC drain pipe must have an appropriate water trap (as to keep air from being sucked through the drain tube) and can be run either directly to a drain or to a condensate pump. In the chance that the drain becomes plugged, the white nylon overflow tube will allow water to escape the unit. If you ever see water coming out of the overflow tube, immediately shut off the unit and check the PVC drain. FRESH AIR CONTROL MODULE (PART-B) The Fresh Air Control Module contains the intelligence and control capabilities required to maintain a comfortable and healthy indoor environment. The module is composed of two halves, an inlet half and outlet half, which each contain air direction dampers. These dampers are what allow the CERV to move between recirculation/ventilation and heating/cooling modes. Additionally, this module contains the controls electronics as well as the temperature, relative humidity, VOC, and CO2 sensors. Revision 0.50 [06/16/2016] Page 5

OTHER COMPONENTS INLINE ECM SUPPLY & EXHAUST FANS To distribute the fresh air throughout the home, while exhausting stale, polluted air, the CERV utilizes two highly efficient Electronically Controlled Motor (ECM) fans. The Fans are simply wired directly to the Fresh Air Control Module s fan output wires and ducted into the system. Both fans for the system should be independently insulated (if the fans are stacked, there should be insulation separating the two). The fan speeds are fully adjustable, and may be configured through CERV s touchscreen controller. When ducted in the CERV, the typical air flow rates with the fans will be between 100 200 cfm. WIRELESS TOUCHSCREEN CONTROLLER While the CERV contains the complex algorithms to keep your air healthy and comfortable, the CERV Wireless Touchscreen Controller exists as your interface to customize the CERV to fit your needs best. The wireless controller allows you to set your heating and cooling setpoints, VOC and CO2 ventilation setpoints, as well as configure the CERV for use with its auxiliary add-ons like the back-up electric duct heater and the wireless ventilation switches. The touchscreen interface was designed from the ground up to be simple and intuitive, retaining a high degree of usability without having to worry about getting lost in a series of menus. Please see the CERV Wireless Touchscreen Controller Guide for more information. OPTIONAL AUXILIARY DUCT HEATER When the outside temperatures start to get very low, it may be desired to use the Auxiliary Duct Heater to add some heating capacity back into the system. The Auxiliary Duct Heater is a 5kW, 240V inline electric heater, which can be configured by the CERV Wireless Touchscreen Controller in a similar manner as the heating setpoint. Again, the CERV Wireless Touchscreen Controller Guide will provide more information on how the auxiliary heater is set up with your system. Additionally, the CERV Installation Manual details the wiring and installation necessary for the Duct Heater. OPTIONAL WIRELESS VENTILATION SWITCHES Through the use of the Wireless Ventilation Switch add-on, the user gains an extra degree of flexibility with the CERV. Typically, these switches are installed in bathrooms, kitchens, work out rooms, etc., where the occupant knows that they will be producing excess moisture or odors that they want to immediately expel from the building. Triggering the switch will send the CERV into a timed ventilation mode, configurable by the user with the Wireless Controller. In addition to the switches, a small wireless relay box is also required, and is installed in the low voltage junction box of the Fresh Air Control Module. There are two styles of ventilation switches, the PTM-265 Rocker Switch and the Active Circuit Transmitter. The PTM-265 is a battery-free rocker style switch, which can be easily mounted inside an existing junction box, or even kept in a drawer or somewhere out of sight. The Active Circuit Transmitter is a small box that wires inline with an existing light switch, detecting when the switch is turned on or off. Either or both styles may be used, and there is no limit to the number of switches that can be used in the building. Revision 0.50 [06/16/2016] Page 6

OPERATION MODES MODES VENTILATION Air quality management is the CERV s top priority. Once you set your indoor air quality setpoint (measured in parts per million, or ppm), the CERV is always watching to make sure that if the pollutant level exceeds your limit, it is promptly dealt with. What level should the setpoint be set? Studies have shown that levels above 1000ppm can indicate a home may have bad odors and indicate negative effects on productivity, alertness, and general comfort. Depending on the sensitivities of the occupant, the air quality setpoint may vary. Some people may be producing good VOCs, such as incense, cooking smells, etc, and allow their setpoint to reach, say, 1500 ppm, while others may be more sensitive and want tighter control. In the case that the CO2 and VOC sensors do not pick up specific elements that you may be sensitive to, you may also set a minimum ventilation level. A Revision 0.50 [06/16/2016] Page 7

minimum ventilation level will devote a portion of the CERV s operating cycle to ventilation, whether or not the sensors indicate it is needed. There is a balance between ventilation and energy usage, which is important for the homeowner to understand. In general, a lower air quality setpoint will result in better quality air and higher energy consumption, while a higher air quality setpoint will result in lower quality air and lower energy consumption. On one hand, you do not want to be over-ventilating your house and producing unneeded conditioning demands on your systems, while on the other hand, you should not sacrifice your air quality and health in order to save a little bit of energy. In some situations, it will actually be nicer outside than it is inside. The CERV can use this to its advantage by either utilizing Free Heating/Cooling mode, in which the heat pump is disabled, or Vent Heating/Cooling mode, in which the heat pump is actively conditioning the air. With these modes, the CERV is able to operate with a very high efficiency, contributing a significant heating or cooling to the home with very little energy usage. A standard ERV or HRV system will often not have the capability to perform in this way. MODES RECIRCULATION If the indoor air quality pollutant level is below the iaq setpoint, but your heating or cooling setpoint is not satisfied, the CERV will enter a Recirculation mode. In this mode, the CERV will simply heat or cool your air, while recirculating it throughout the house. This will significantly impact the comfort and air quality of the home, keeping it uniform throughout all the living areas. This works especially well when the CERV is working in tandem with a point-source mini split heat pump, where the CERV is able to spread the conditioning power of the mini split to all of the living spaces, eliminating the need for zone control. MODES HEATING / COOLING With the CERV s heat pump module, a small amount of heating or cooling capacity can be efficiently contributed to the home. It is important to note that in some cases the CERV may be able to handle the entire heating and cooling demands on average, it is often recommended to have an additional heating/cooling source (such as a mini split heat pump) for times of very high heating and cooling demands. The compressor operates at a maximum of around 500w, so even with a high COP, the CERV may only deliver 1500-2500w of heating (5000-8500 BTU/hr) or 1000-1500w (3500-5000 BTU/hr) cooling capacity. MODES OFF When there is no demand for heating, cooling, or ventilation, the CERV may simply shut itself off in order to save energy. In this mode, the CERV will move its internal dampers into the Recirculation position, as to keep outside air from coming in, and then turn its fans off. Approximately every 10 minutes, the CERV will perform an Assessment, in which the fans are turned back on for a few minutes (still in Recirculation, but with the heat pump off). If the indoor temperature and air quality is still satisfactory after the assessment period, the CERV will turn back off; otherwise it will enter one of its various other modes depending on the conditions. This assessment period additionally acts as a way to periodically help mix the inside air to create a more uniform comfort and air quality. Revision 0.50 [06/16/2016] Page 8

ENERGY RECOVERY While typical ERVs and HRVs use a simple heat exchanger core or heat recovery wheel, the CERV uses its integrated heat pump for energy recovery. Instead of using a direct heat exchanging methods, which may accomplish a heat recovery effectiveness of 80-90%, the CERV indirectly uses the refrigerant in the heat pump to transfer the heat between air streams, and is able to accomplish a heat recovery effectiveness greater than 100%. As an example, say it is 68F inside and 40F outside; a cool fall day. A typical ERV/HRV will be exchanging energy, but even at a very high efficiency, will be delivering air that is cooler than the inside temperature (~65F for 90% efficiency). The CERV, on the other hand, will be using its heat pump to exchange energy, allowing a heat recovery efficiency closer to 160% (delivering ~85F air inside). This ensures that conditioned air is delivered to your living spaces, increasing your comfort level, rather than feeling cool air being delivered when your home needs to be heated. There may be some times of the year in which it is beneficial to not exchange any energy when ventilating the home. For example, take a cool summer night (60F outside) when your home is still in need of air conditioning (78 inside). A typical ERV/HRV with a high efficiency will be heating the outside air up to ~76F, when it would be much more effective to simply ventilate the home with the 60F outside air. The CERV is able to determine when scenarios like this occur, and promptly act as to maximize comfort and minimize energy consumption in the best way possible. It would simply enter a ventilation cooling mode, but leave the compressor off, so that no energy is being exchanged and fresh, cool air is brought directly into your living areas. Revision 0.50 [06/16/2016] Page 9

TROUBLESHOOTING CERV STARTUP After applying power to the system, neither fan starts and the touchscreen controller shows the not connected wireless connectivity icon Possible Cause 120v not present at PART-B High Voltage (120V) control board damaged Action to resolve 1. Check circuit breaker to see if circuit tripped 2. Measure AC voltage at 120 H and 120L wire connections 3. Open removable panel in PART-B and test AC voltage at output of transformer. 4. Call Build Equinox for further troubleshooting Either supply or exhaust blower does not start Possible Cause Action to resolve Check both fuses inside the PART-B low voltage junction box Blown fuse Check that no shorts exist at either fan Check that the fan has 120VAC supply Fan is damaged Check that PWM input on fan has DC voltage Call Build Equinox for replacement High Voltage (120V) control Open removable panel in PART-B and check for bad connections board damaged Call Build Equinox for further troubleshooting and replacement ERROR MESSAGES CERV Error: Heat Pump Comm The CERV is unable to communicate with the heat pump variable speed inverter Does Heat Possible Cause Action to Resolve Pump Operate? Yes No No No Bad connection between FR to White wire Bad connection between FT to Green wire Bad connection between F+ to Black wire PART-A 120v connection is unpowered Heat pump inverter damaged Check FR, FT, and F+ connections in PART-A Low Voltage Junction Box Check power wiring to ensure 120v at 120 H and 120 N wires in PART-A junction box Call Build Equinox for replacement Revision 0.50 [06/16/2016] Page 10

CERV Error: Heat Pump Freq The CERV can communicate with the heat pump variable speed inverter, but the compressor is not starting because the inverter has not received a speed command. Possible Cause Bad connection between F- to Red wire Loose wire connection inside the CERV Action to Resolve Check F- connection in PART-A Low Voltage Junction Box With the CERV in heating or cooling mode, measure DC voltage between F+ and F- terminals. Typical DC voltage is around 4V. If no voltage available, check wire connections in the PART-A removable panel. CERV Error: Ref # This error exists if a temperature, relative humidity, CO2, or VOC sensor goes bad. Please call Build Equinox with this reference number so a new sensor can be sent for replacement. Revision 0.50 [06/16/2016] Page 11

1103 N. High Cross Rd. Urbana, IL 61802 support@buildequinox.com (773)-492-1893 Build Equinox 2016 All Rights Reserved