DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

Similar documents
ROOM-BY-ROOM DEMAND CONTROLLED HEAT RECOVERY VENTILATION

2013 innovation. Room-by-room demand controlled heat recovery ventilation

DXR 230 PREMIUM. dx system INSTALLATION AND MAINTENANCE INSTRUCTION (ENGLISH VERSION)

INSTALLATION AND MAINTENANCE INSTRUCTION (ENGLISH VERSION) dx system DXA 230 PREMIUM. Heat recovery unit with demand control for cupboard installation

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

VENTILATION SOLUTIONS PRODUCTS CATALOGUE

Healthy, comfortable and energy-efficient ventilation

VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS

InspirAIR Home RESIDENTIAL AIR PURIFICATION

Dee Fly Cube 300 and 370. Heat Recovery ventilation

Healthy, comfortable and energy-efficient ventilation

CI/SfB (57.5) November 2008

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Residential Heat Recovery Ventilation. REHVA European Guidebook No 25

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

better ventilation Maximum effect minimum dimensions

KOMFORT EC DB Suspended heat recovery air handling units

Zehnder Comfosystems. ComfoAir 180 Datasheet

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

SELECTION GUIDE AIR PURIFICATION AND CENTRALISED MECHANICAL EXHAUST VENTILATON

BXC AIR EXHAUST GRILLE FOR MECHANICAL VENTILATION WITH AUTOMATIC AIRFLOW CONTROL

That allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

Ventilation Unit Zehnder ComfoAir 350

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

Ventilation unit Zehnder ComfoAir 200

Endura Delta. Demand- and app-controlled ventilation system with heat recovery

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

Breathe Fresh Air at Home

Controlled mechanical ventilation GB 03

Flexit air handling units UNI 2, 3 og 4

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

DATA SHEET 01. Function. Features SUP. OUT EX optional OUT EX OUT SUP OUT SUP. Customized connection possibilities as standard.

InspirAIR Home RESIDENTIAL AIR PURIFICATION

MAKING MODERN LIVING POSSIBLE. Danfoss Air Catalogue. Catalogue DANFOSS HEATING

Healthbox II. Demand controlled ventilation

CENTRALISED MECHANICAL EXTRACT RESIDENTIAL VENTILATION AND AIR PURIFICATION

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

VENTILATION WITH HEAT RECOVERY

SIMPLICITY FULL MODULARITY?

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

Flexit air handling units C2 and UNI 2, 3,4

exhaust air intake air

HRV Enthalpy. Catalogue

Lo-Carbon Sentinel Kinetic Horizontal

CONTENT: VEX308 Decentralised ventilation VEX308

Small Room Heat Recovery Ventilation

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

Ventilation & Heat Recovery. The whole house system from OMNIE

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA VENTILATION EXPORT 01/2018 SILENT VENTILATION

ECO ROOF FAN. A modern, energy-saving roof fan with a DC motor. INSTALLER Register the roof fan for an extended 5 year guarantee!

Think System Solution to get it right first time

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Technical Information HXV - HRV Ventilation

AIR HANDLING UNITS MANDÍK

Outside Air Requirements... SOLVED!

Overview and Specifications

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

SIMPLICITY OR FULL MODULARITY?

SINGLE-ROOM VENTILATION. for schools and public spaces

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

FRESHBOX 100. Single-room heat recovery unit. Air capacity up to 100 m³/h Heat recovery efficiency up to 96 %

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

COMPACT VENTILATION UNITS DUPLEX R5

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

with minimal heat loss for a pleasant and healthy living environment

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Energy Recovery, Wholehouse Ventilation ECO LIVING

air handling units AT THE LEADING EDGE OF AIR FLOW

WHHR Midi & Midi Lite

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Ventilation systems. Indoor air quality for inner well-being

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Indirect Evaporative Air Conditioning FACTORY INSTALLATION (CW-160)

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

recooler HP EQKR HEAT PUMP

Intelligent Air Solutions

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

Passive House Northwest AIA CEU Provider. Aubrey Gewehr March 27, 2015

AIR HANDLING UNITS. AmberAir Compact Smarty RIS EKO 3.0 RIRS EKO 3.0

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

DEMAND-CONTROLLED HOME VENTILATION

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

NEW VENTILATION AIR CONDITIONING AIR CLEANING HEATING SAP-Q APPENDIX Q ELIGIBLE

Transcription:

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

2 AERECO DX system DX SYSTEM A COMPLETELY NEW HEAT RECOVERY VENTILATION RANGE With the experience of a very innovative room-by-room demand controlled heat recovery ventilation (HRV) system, several new products now complete the Aereco HRV range. These products are dedicated to residential applications and can be either installed in false ceiling, thanks to a small thickness, or in kitchen cupboard, due to optimized dimensions.

AERECO DX System 3 BRING SERENITY AND COMFORT IN YOUR HOME WITH THE NEW DX SYSTEM The DX System is a range of smart heat recovery ventilation systems that continually supply pollen-free and dust-free preheated fresh air to living areas, ensuring a comfortable feel-good climate. Using the DynamiX Technology* which consists of a smart airflow control management, the DX System offers optimal indoor air quality and limits all inherent noises from the ventilation system. This technology allows to the DX System to go beyond standard energy recovery, by adapting with accuracy the airflows to the occupants needs in all rooms. Best energy efficiency Whether fully room-by-room demand controlled (Excellence version) or partially room-by-room controlled at the supply and room-by-room controlled at the exhaust (Premium version), the DX System optimally uses the exhaust heat to preheat the fresh air and thus offers an energy-efficient solution, whatever the version. Moreover, the demand controlled management enables to significantly the electrical consumption of the system. The best energy-efficiency class A+ is achieved by all the versions of the DX System. Comfort and Indoor Air Quality at their best The DX System enhances indoor comfort by providing healthy air, at a milder temperature, preheated by the integrated heat exchanger. To feel good at home, the DynamiX Technology, available on Excellence version, adapts, at any time, both supply and exhaust airflows to the occupants needs in every room through accurate sensors (CO 2 or presence). The DynamiX Technology is a smart demand control strategy specific to the DX System which follows two main purposes: to reduce inherent noise from the heat recovery system while guaranteeing the best Indoor Air Quality. Besides, in order to maximise the filters life-time, their dimensions and filtration surface have been totally optimised to prevent from outdoor particles. Touch screen controls for display, setup and diagnosis A colour LCD touch screen allows the occupant to view system parameters, to diagnose operation, to control setups such as automatic bypass temperature, to boost ventilation or to action a free cooling on demand. It also notifies the occupant when the filters need to be replaced. *specific to Excellence version

4 AERECO DX system DYNAMIX TECHNOLOGY : AN OUTSTANDING ENERGY PERFORMANCE THROUGHOUT THE YEAR By combining the benefits of full demand controlled airflows and heat recovery, which are the pillars of the DynamiX technology, the DX System, in Excellence version, delivers outstanding energy performance. Modulation enables a significant reduction in average airflows while providing excellent air quality, with heat losses produced by ventilation lowered by half on average in comparison with a constant airflow ventilation. The heat exchanger operates with a yield of about 87% recovery (DXR efficiency: 82%; DXA efficiency: 93%). Combined, these features achieve about 92% energy savings when compared with a mechanical exhaust ventilation system at constant airflow, with the same indoor air quality. MODULATION 50% savings on the airflows HEAT EXCHANGER 87% + = heat recovery more than 92% savings on air renewal heating 50% savings on electrical consumption The average airflow reduction, due to the demand control ventilation offered by the DX System, also generates important savings on electrical consumption and the impact of this on preheating and fan power (see below) is very positive, saving more than 50% electrical power in comparaison with a constant airflow heat recovery with 92% efficiency. Heat recovery 92% efficiency 50% savings on the electrical consumption Pre-heating (electrical) Fans consumption (electrical) Heat losses through ventilation Aereco DX System heat recovery Average power consumption Conventional heat recovery How a full demand controlled airflows can reduce electrical consumption of the fans In addition to significant energy savings on heat losses, the DX System reduces primary energy consumption by reducing fan power of the unit. The fan type used (highly efficient brushless electronic commutation motors), low pressure operation and average airflow reduction through demand controlled ventilation (50%) allow the DX System to work at an average power greatly reduced compared to that of a standard heat recovery system using one or several speeds. Power consumption is thereby reduced by more than 50%. DX SYSTEM Average airflow Filters kept clean longer = less power consumption By reducing the average airflows (by about 50%) with an equivalent indoor air quality, the DX System reduces the rate of filters clogging, thanks to the reduce volume of air passing through the filters at any given period. Filter durability is doubled compared to traditional heat recovery systems, thereby reducing pressure drops and the power consumption of the motors.

AERECO DX System 5 DX SYSTEM - AS FLEXIBLE AS NEEDED, FOR RENOVATION AND NEW BUILD Through the DX System, a completely new range of heat recovery ventilation systems has been designed by Aereco to offer you the maximal flexibility in your choice for the adequate ventilation solution. False ceiling installation Designed for ceiling installation within the heated space, the DXR provides a truly elegant solution for multi-apartments buildings, where available space for systems is often limited, particularly in renovation projects. Its very low thickness (26 cm) and its reduced width (65 cm) allow easy installation in ceiling spaces (for example in a corridor false ceiling). The DXR unit is compatible with two demand control strategies used in the DX System Premium and Excellence. Wall mounted application The DXA has been specifically designed for cupboards installation. Thanks to its well-fitted dimensions, the DXA can be installed both in kitchen and in other technical rooms, wall-mounted. A creamy white metal sheet covers the front face of the the DXA which allows it to be unnoticed as a technical equipment. The DXA unit is compatible with two demand control strategies used in the DX System Premium and Excellence. SIMPLIFIED INSTALLATION AND EASY FILTERS CHANGE DXR and DXA have been specifically designed to ensure that only one person is required to install them. Wether it is done by using an ingenious concept for the DXR or by specific handles on the side fore the DXA, both of these new products use innovative concept to simplified their installation. Filters can be easily replaced without dismounting the unit, both on the DXR and on the DXA, by just simply removing the trapdoors.

6 AERECO DX system A SMART SYSTEM AVAILABLE IN TWO VERSIONS OPTIMISED FOR THE AIRFLOW CONTROL 5 8 7 6 6 3 2 1 4 5 3 3 3 9 5 5 The DX System is comprised of a heat recovery unit (DXA Unit or DXR Unit 1 ) connected to exhaust and supply ductworks. The counter-flow heat exchanger, integrated into the main unit, ensures the recovery and transfer of most of the energy from the exhaust air to the supply air, thus limiting the energy required to heat the fresh air. Airflows are automatically controlled according to the needs of each dwelling s room (room by room DCV): Outdoor filtered air is supplied 3 in the bedrooms and in the living room. Stale air is extracted 6 from the kitchen, bathroom and WC. On the supply side, depending on the DX System version installed, one or many sensors 5 can adjust the airflow to all main rooms based on the CO 2 level or based on the presence detection. On the exhaust side, the BXC units adjust automatically the airflow, according to parameters read by various sensors: humidity (used in the kitchen, in the bathroom and in WC), presence (can be used in WC). Versions with switch, presence, remote, CO 2 or VOC sensors can also be used for exhaust units. At all times, total supply airflows and total exhaust airflows are measured by the heat recovery unit. These airflows are balanced thanks to an exhaust controlled compensation valve 8. This valve can be located in the bathroom or in the kitchen. In Excellence version only, an additional compensation valve, integrated in the DX Hub 2, adjusts supply compensation airflow, supplying preheated 9 fresh air in the living room, in the kitchen or in a corridor. Compensation valves are linked to dedicated compensation exhaust unit 7 or dedicated compensation supply unit 4. The use of an exhaust compensation valve is also a solution to increase considerably the airflows. This scenario is used in order to get a very efficient over-ventilation mode, also called free cooling mode. To reach the required supply airflows in each main room (bedrooms or living room), dedicated dampers located in the DX Hub 2 modulate room by room supply airflows according to the information sent by each electronic sensors placed in the main rooms. For example, when the main rooms are occupied, the presence or CO 2 sensors that are located in these rooms send the information to the system to adapt the airflow according to the demand. To reach the required exhaust airflows in each technical room (kitchen, bathroom, WC,...), dampers located in the exhaust units modulate room by room extract airflows according to the passive or active sensor placed within each exhaust unit. Supply airflows and exhaust airflows are measured by the use of accurate pressure sensors placed in the heat recovery unit. This allows to calculate with a high accuracy supply and exhaust airflows, without influence of clogging filters or ductwork pressure drop. It ensures the highest efficiency for the system. So that, energy savings are at their maximum.

AERECO DX System 7 Excellence version The Excellence version corresponds to the best HRV solution in terms of indoor air quality and energy savings. In this version, the DX System uses the DynamiX Technology, which consists in adapting airflows room-by-room based on specific needs, while balancing supply and exhaust. An active distribution box, DX Hub, connected to CO 2 or presence sensors located in all the main rooms, adjusts supply airflows through driven dampers. The exhaust airflows are controlled by humidity sensors or presence detectors or other activators included in the exhaust units. Premium version The Premium version keeps the very precise demand control management of the Excellence version, but the supply airflows are controlled globally through at least one CO 2 or presence sensor located in a main room (no active DX Hub is used). Exhaust and supply airflows are permanently balanced. Exhaust airflows are controlled by humidity sensors or presence detectors (notably) built in the exhaust units. The DynamiX Technology, ensures a total quietness of the system and optimal indoor air quality, providing a maximum comfort at home. DX System components: Premium version Excellence version 1 DX Unit Heat recovery unit with balanced demand controlled airflows 1 (DXR or DXA) 1 (DXR or DXA) DXR DXA 2 DX HUB 5 DX HUB 6 DX Hub Distribution box for demand controlled supply airflows - 1 (DX Hub 5 or 6) 3 4 SDC 100 Supply unit SDC 125 Supply unit for balance 1 to 6 1 to 6-1 5 5 S-CO2 CO 2 sensor at least 1 (S-CO2 S-PRE or S-PRE) Presence sensor 1 to 5 (S-CO2 or S-PRE) 6 7 8 BXC Exhaust unit with integrated humidity, presence detection or other sensors BXC b Exhaust unit for balance MCP 125 Exhaust compensation valve 1 to 5 1 to 5 1 1 1 1 9 Preheater Galvanised steel body with built-in resistance 1 (optional) 1 (optional) Touch screen Display and control module for the user also used for maintenance 1 1 Note: Some other components may be used in the system such as condensation exhaust pump, acoustic silencers, etc. See page 18 and page 19.

8 AERECO DX system HIGH QUALITY MANUFACTURE DXR: Top efficient heat recovery unit with a top model size With a base, a distribution box and vital parts all being made of metal, DXR wins on quality and maximum durability. Most of its components (motor, fans, and heat exchanger) are manufactured in Germany and assembled in Aereco, in France. Base Control and power supply box Fans Heat exchanger Condensation receiver Access cover Filter G4 Filter F7 Filter trapdoors

AERECO DX System 9 DXA: So much discreet that it will go unnoticed in the technical room The main material used to produce the DXA, the EPP (Expanded Polypropylene), is a green material, environmentally friendly, 100% recyclable. It does not include any VOC (volatile organic compound), CFC (chlorofluorocarbon) or other compounds known to be particularly harmful to the environment. In addition, weighting only 16 kg, DXA has a very high resistance to weight ratio. Filter F7 Bypass Fan Filter G4 Base Ductwork white metal sheet cover (optional) Exhaust and supply galvanized ducts Base Control and power supply box Fan Bypass Condensate pump / siphon Heat exchanger Filter F7 Condensation receiver Base Interface base Filter trapdoors Condensation receiver White metal sheet cover

10 AERECO DX system DXR - Dimensions in mm 140 140 1260 1160 158 246 258 124 328 714 328 DN160 650 316 DN160 125 DXA - Dimensions in mm ø160 ø160 88 130 1189 101 166 80 240 R2,50 40 1184 R80 545 138 118 R80 248 155 151 554 482 101 164 210 155 248 151 545

AERECO DX System 11 DX Hub 5 - Dimensions in mm DN 160 DN 100 DN 125 DN 100 DX Hub 6 - Dimensions in mm 755 695 129 200 114 100 280 685 636 124 636 100 100 100 200 DN 100 118 151 21,5 640 577 31,5 DN 160 520 494 468 433 151 546 DN 13 Ø13 78 134 254 340 Ø158 126 105 685 DN75 Ø158 695 773

12 AERECO DX system DXR Heat recovery unit for ceiling installation A+ A B C D E F G A+ Standard code Ecodesign Label (EU Ecodesign Directive) DXR 230 DXR1225 A+ (with 2 IAQ sensors) Airflow characteristics Max. airflow m 3 /h 230 Other nominal airflows m 3 /h 80 / 140 / 200 Pressure at exhaust Pa 60 Airflow compensation (filter clogging) automatic Airflow balance (supply and exhaust) automatic Acoustics Sound power level Lw @ 161 m 3 /h, 50 Pa db(a) 40 Sound power level Lwa [ a / b / c / d ] db 40 / 43 / 46 / 49 Electrics Power supply 230 VAC, 50 Hz Motor type EC (x2) Power consumption @ 161 m 3 /h @50 Pa W 34,2 Power consumption @ 230 m 3 /h @145 Pa W 91,0 Sensors connections RJ12 Demand control Compatible versions of DX System Premium / Excellence Min - Max Number of sensors for modulation at supply 1-5 Min - Max Number of sensors for modulation at exhaust 1-5 Sensors type at supply presence / C0 2 Exhaust units type humidity / presence / switch / C0 2 / VOC Characteristics Exchanger aluminium / counter flow type / 82% efficiency Filters on supply air: 1 x F7 / on exhaust air: 1 x G4 Weight kg 46 Colour white Material (main) galvanised steel with phonic and thermal insulation Dimensions mm with duct connectors: 260 x 650 x 1200 / without duct connectors: 260 x 650 x 1160 Certifications CE Installation Max. number of main rooms 6 Max. number of technical rooms 5 Connections 2 x (2 x ø160 mm) Installation horizontal only, to the ceiling / 4 points of attachment Other functions Interface 2,8 colour touch screen interface. Wired to DXR Bypass controlled by outdoor temperature / also used for free cooling Preheating (optional) with resistance in fresh air ductwork from outside Condensation management exhaust through lateral tube / optional condensate pump Temperature of use Installation room frost free: +5 C < T < +50 C Incoming outdoor fresh air or Extract -5 C < T < +50 C without preheating / -26 C < T < +50 C with preheating

AERECO DX System 13 DXA Heat recovery unit for wall installation A+ A B C D E F G A+ DXA 230 Standard code DXA1240 DXA1247 Ecodesign Label (EU Ecodesign Directive) A+ (with 2 IAQ sensors) Airflow characteristics Max. airflow m 3 /h 230 Other nominal airflows m 3 /h 80 / 140 / 200 Pressure at exhaust Pa 60 Airflow compensation (filter clogging) automatic Airflow balance (supply and exhaust) automatic Acoustics Sound power level Lw @ 161 m 3 /h, 50 Pa db(a) 52 Sound power level Lwa [ a / b / c / d ] db 49 / 54 / 59 / 60 Electrics Power supply 230 VAC, 50 Hz Motor type EC (x2) Power consumption @ 161 m 3 /h @50 Pa W 36,5 Power consumption @ 230 m 3 /h @50 Pa W 92,0 Sensors connections RJ12 Demand control Compatible versions of DX System Premium / Excellence Min - Max Number of sensors for modulation at supply 1-5 Min - Max Number of sensors for modulation at exhaust 1-5 Sensors type at supply presence / C0 2 Exhaust units type humidity / presence / switch / C0 2 / VOC Characteristics Exchanger polystyrene / counter flow type / 93% efficiency Filters on supply air: 2 x F7 / on exhaust air: 1 x G4 Weight kg 23 Colour white Material (main) expanded polypropylene (EPP) covered by a white galvanized metal sheet Dimensions mm with duct connectors: 1428 x 552 x 545 without duct connectors: 1188 x 552 x 545 Certifications CE Installation Max. number of main rooms 6 Max. number of technical rooms 5 Connections 2 x (2 x ø160 mm) Installation vertical only, to the wall / 2 x 4 points of attachment Other functions (in option) Interface 2,8 colour touch screen interface / can be built-in or fixed separately Bypass controlled by outdoor temperature / also used for free cooling Preheating (optional) with resistance in fresh air ductwork from outside Condensation management condensate pump exhaust through siphon Temperature of use Installation room frost free: +5 C < T < +50 C Incoming outdoor fresh air or Extract -5 C < T < +50 C without preheating -26 C < T < +50 C with preheating

14 AERECO DX system DXR - Airflow characteristics 350 300 250 200 150 100 50 Pressure in Pa a 0 0 50 100 150 200 250 DXR Unit maximal airflow setting : 80 m 3 /h 140 m 3 /h 200 m 3 /h 230 m 3 /h b Sound power level Lwa a = 40 db b = 43 db c c = 46 db d = 49 db d Airflow in m 3 /h Power in W 100 90 80 70 60 50 40 30 20 10 0 0 50 100 150 200 250 DXR Unit maximal airflow setting : 80 m 3 /h 140 m 3 /h 200 m 3 /h 230 m 3 /h Airflow in m 3 /h DXA - Airflow characteristics 350 300 250 200 150 100 50 Pressure in Pa a 0 0 50 100 150 200 250 DXA Unit maximal airflow setting : 80 m 3 /h 140 m 3 /h 200 m 3 /h 230 m 3 /h b Airflow in m 3 /h Sound power level Lwa a = 49 db b = 54 db c c = 59 db d = 60 db d 100 90 80 70 60 50 40 30 20 10 Power in W 0 0 50 100 150 200 250 DXA Unit maximal airflow setting : 80 m 3 /h 140 m 3 /h 200 m 3 /h 230 m 3 /h Airflow in m 3 /h

AERECO DX System 15 DX HUB 5 Active air supply distribution box Standard code HUB1288 Airflow characteristics Pressure at supply Pa 25 Acoustics Phonic enveloppe Phonic silencers - Electrics Electrical connections (sensors) 5 x RJ12 Characteristics Weight kg 10,9 Dimension mm 592 x 490 x 206 Colour metal Material (main) galvanised steel with phonic and thermal insulation Inlet duct connections (to DXR or DXA) choice among 2 x ø160 mm Outlet duct connections (to the supply units) 5 x ø100 mm + 1 x ø125 mm Installation Installation horizontal or vertical Installation room frost free: +5 C < T < +50 C standard DX HUB 6 Active air supply distribution box Standard code HUB1434 Airflow characteristics Pressure at supply Pa 65 Acoustics Phonic enveloppe Phonic silencers Electrics Electrical connections (sensors) 5 x RJ12 Characteristics Weight kg 18 Dimension mm 695 x 684 x 199 Colour metal Material (main) galvanised steel with phonic and thermal insulation and acoustic silencers Inlet duct connections (to DXR or DXA) choice among 3 x ø160 mm Outlet duct connections (to the supply units) 6 x ø75 mm Installation Installation horizontal or vertical Installation room frost free: +5 C < T < +50 C standard

16 AERECO DX system

AERECO DX System 17 WHICH COMPONENTS FOR WHICH VERSION? DXR, DXA, DX Hub 5, DX Hub 6, exhaust compensation valve, supply units,..., how to choose among all of these different products and how many components are used in the system? The following tools answer to all your questions in a very simple way: The first table is a recap which highlight the diffrences between Excellence version and Premium version. The second table allows you to determine which system suits the best to your project. PREMIUM VERSION EXCELLENCE VERSION Silent operation optimized (DynamiX technology) Indoor Air Quality control strategy global DCV full DCV Indoor Air Quality performance ++ +++ Savings on airflow modulation up to 30 % up to 50 % Filter lifetime (in comparison with constant HRV) up to 30 % longer up to 50 % longer Free cooling mode X X Boost mode X X TO SELECT COMPONENTS FOR YOUR DX SYSTEM INSTALLATION, ANSWER TO THESE 8 QUESTIONS : Your answer : 1 Do you want to install the HRU on a wall (W) or in a false ceiling (C)? W = DXA C = DXR 2 Do you want a DCV which adapts supply airflows room-by-room (R) or globally (G)? R = Excellence G = Premium 3 Do you want to use rigid ducts (R) or semi-flexible ducts (S)? R = DX Hub 5 S = DX Hub 6 4 How many rooms will have to be equipped with presence (P) or CO 2 (C) sensors? (P) Nb of presence sensor = (P) Nb of CO 2 sensor = 5 How many technical rooms will have to be equipped? Nb of BXC = 6 Do you want to have the user interface on a wall (W) or built-in (B) the heat recovery unit? W = Wall B = Built-in 7 Is it for a new building (N) or a refurbishment (R)? N = Siphon R = Pump 8 Does outdoor can reach oftenly a temperature below than -5 C (Y/N)? YES = Preheater NO = No preheater

18 AERECO DX system Heat recovery unit for ceiling installation DXR 230 + DXR1225 AD224 BF14 BXCxxx SDC1107 Exhaust compensation valve Exhaust compensation unit Exhaust unit PREMIUM VERSION: GLOBAL DCV HRV EXCELLENCE VERSION: FULL DCV HRV IHM1195 Wall interface DX HUB 5 CO2 sensor CAP1100 Presence sensor at least 1, up to 5 HUB1288 SDC1108 IHM1293 Wall interface CO2 sensor CAP1100 Presence sensor at least 1, up to 5 OR ² HUB1434 DX HUB 6 Preheater Acoustic silencer IHM1362 CO2 sensor CAP1100 Presence sensor at least 1, up to 5 AD098 Wall interface x1 F7 x1 G4 AD254 Filter kit RJ45 cable 1 / main room up to 6 CAP1101 Supply compensation unit Supply unit 1 / main room up to 5 Siphon ACCESSORIES BASIC ITEMS DXR CAP1101 Condensate pump AD099 Fixing suspension system 5 m : AD197 10 m : AD123 5 m : AD249 10 m : AD250 20 m : AD251 30 m : AD252 RJ12 cable AD106 CAP1101

AERECO DX System DXA 19 Heat recovery unit for wall installation DXA1240 Condensate pump OR DXA1247 DXA230 + Siphon Exhaust compensation valve AD224 BF14 BXCxxx SDC1107 Exhaust compensation unit Exhaust unit Supply unit 1 / main room up to 5 1 / main room up to 6 AD098 Metal white front cover (for IHM 1439) x2 F7 x1 G4 CO2 sensor OR CAP1100 Presence sensor CAP1101 Upper design cover AD449 RJ45 cable Metal white front cover (for IHM 1438) AD555 EX at least 1, up to 5 IHM1439 Built-in interface ACCESSORIES Wall interface AD448 EX AD428 Filter kit IHM1438 PREMIUM VERSION: GLOBAL DCV HRV Preheater IHM1294 RJ12 cable 5 m : AD197 10 m : AD123 Acoustic silencer 5 m : AD249 10 m : AD250 20 m : AD251 30 m : AD252 HUB1288 SDC1108 Supply compensation unit DX HUB 5 EXCELLENCE VERSION: FULL DCV HRV BASIC ITEMS DXA230 + Wall interface OR IHM1295 Built-in interface OR IHM1440 HUB1434 DX HUB 6 Wall interface OR IHM1441 Built-in interface CO2 sensor CAP1100 Presence sensor at least 1, up to 5 CAP1101

Aereco S.A. 62 rue de Lamirault Collégien 77615 MARNE LA VALLEE CEDEX 3 FRANCE tel. +33 1 60 06 26 63 fax +33 1 64 80 47 26 www.aereco.com FLY651GB_v5 Copyright Aereco Images: Aereco, Fotolia All data and pictures in this document are non contractual and are subject to change without prior notice.