LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

Similar documents
LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

13 GEP A L P - 1 A

RGE 13 A T - 1 A

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

2 shp 13 lc 1 36 t - 1 a

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

PRPDF16 PRODUCT SPECIFICATIONS PRP DF P A SINGLE STAGE GAS VALVE TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER

MERIT Series R-410A - Upflow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

MERIT SERIES Up Flow / Horizontal

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

T P A 120 S 4 S N 1 Y

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

T S A 048 S 4 N 4 1 T

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

14 AC x

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

ELITE Series Variable Capacity

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

CB X 32 mv

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Visit us at For the latest technical information,

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

ELITE Series R-410A - Two-Stage Compressor

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

T P A 048 S 4 N 4 1 T

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

Corp L2 Revised

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

ELITE Series Variable Capacity

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Commercial High-Efficiency Condensing Units

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

MERIT SERIES Downflow

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

Commercial High-Efficiency Condensing Units

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

ELITE SERIES Downflow - High Efficiency Blower Motor

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

High Heat COP. High/Low Stage

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

Product Data. Fig. 1 - Unit 50VR -A

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

PACKAGE AIR CONDITIONER

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

SKYPAK II, 3 Ton Series, gives you a

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

PRPHP16 PRODUCT SPECIFICATIONS PRP HP P A TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER MINOR REVISION SEQUENCE A = 1ST GENERATION

Lennox 8 Series Single Zone - R-410A

HIGH EFFICIENCY AIR HANDLER

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

GREEN REFRIGERANT R-410A

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

MACH N-407 Heat Pump Air-Cooled Chiller

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

MERIT SERIES Downflow

Transcription:

PA C KA G E D E L E C T R I C / E L E C T R I C LRP4AC Residential - R-40A Bulletin No. 079 July 08 P R O D U C T S P E C I F I C AT I O N S Supersedes Janury 08 SEER - 4.00 to 5 Tons Cooling Capacity -,600 to 57,000 Btuh Optional Electric Heat - 5 to 0 kw MODEL NUMBER IDENTIFICATION L RP 4 AC 36 P - -A Minor Revision Sequence A = st Generation Brand L = Lennox Product Type RP = Residential Packaged Unit Nominal SEER 4 = 4 SEER Unit Type AC = Electric/Electric Unit Major Revision Sequence = st Generation Voltage P = 08/30V-phase-60hz Nominal Cooling Capacity 4 = tons 30 =.5 tons 36 = 3 tons 4 = 3.5 tons 48 = 4 tons 60 = 5 tons

FEATURES CONTENTS Blower Data... 0 Cooling Ratings... 9 Dimensions - Accessories... 3 Dimensions - Unit... Electrical/Electric Heat Data... 7 Electric Heat Capacities... 7 Features... Field Wiring... 8 Installation Clearances... 9 Model Number Identification... Optional Accessories... 6 Specifications... 5 WARRANTY Compressor - Ten year limited warranty in residential installations and five years in non-residential installations. All other covered components - Five years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPROVALS AHRI Certified to AHRI Standard 0/40-008. Units are design certified by ETL Intertek. Cooling system rated according to DOE test procedures. Units are ETL certified for the U.S. and Canada. Packaged unit and components within bonded for grounding to meet safety standards required by UL. Optional electric heaters are ETL listed for the US and Canada and are rated and tested according to DOE test procedures and FTC labeling regulations. Each unit test operated at the factory before shipment ensuring dependable operation at start-up. APPLICATIONS Designed for outdoor installations at ground level or rooftop for residential applications. SUPPLY AIR BLOWER Direct Drive Blower Each blower wheel is statically and dynamically balanced. Multi-speed, direct drive blower motor on 4 through 48 models. Constant-torque ECM direct drive motor on the 60 model. Change in blower speed is easily accomplished by simple wiring change on blower motor. Blower assembly easily removed for servicing See Blower Performance tables. REFRIGERATION SYSTEM R-40A Refrigerant Non-chlorine, ozone friendly, R-40A. Unit pre-charged with refrigerant. See Specification table. Evaporator and Condenser Coils Copper tube with aluminum fin coils. Anti-Microbial Evaporator Coil Drain Pan Anti-Microbial additive resists growth of mold and mildew on drain pan which improves indoor air quality and reduces drain line blockage. Condenser Fan Weather protected heavy duty condenser fan motor with coated steel fan blades for long life. Internally mounted. Totally enclosed motor. Fan guard constructed of corrosion-resistant coated steel. High Pressure Switch Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Automatic reset. Loss of Charge Switch Shuts off unit if suction pressure falls below setting. Provides loss of charge and freeze-up protection. Optional Accessories Drain Pan Overflow Switch Monitors condensate level in drain pan, shuts down unit if drain becomes clogged. LRP4AC - to 5 Ton Packaged Electric / Electric / Page

FEATURES SCROLL COMPRESSOR Compressor features high efficiency with uniform suction flow, constant discharge flow and high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Compressor is installed in the unit on resilient rubber mounts for vibration free operation. Optional Accessories Compressor Crankcase Heater Protects against refrigerant migration that can occur during low ambient operation. Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor. This type of motor normally doesn t need a potential relay and start capacitor. In conditions such as low voltage, this kit may be required to increase the compressor starting torque. Compressor Timed-Off Control Prevents compressor short-cycling and allows time for suction and discharge pressure to equalize. Permits compressor start-up in an unloaded condition. Automatic reset with 5 minute delay between compressor shut-off and start-up. CABINET Conditioned areas insulated with foil faced insulation to minimize heat loss and reduce operating sound levels. Powder paint for maximum durability. Easy service access. Steel louvered panels provides complete coil protection. Airflow Choice Units are shipped in horizontal configuration and can be field converted to downflow (vertical) airflow with optional Downflow Conversion Kit. Electrical Inlets and Service Valves Field wiring inlets are located in one central area of the cabinet. See dimension drawing. Gauge ports are located inside the cabinet. Optional Accessories Downflow Conversion Kit Required for field conversion to downflow (vertical) air. Kit consists of duct covers to block off horizontal air openings on side of unit. Kit also includes drain pan overflow switch to monitor condensate level in drain pan, shuts down unit if drain becomes clogged. Lifting Brackets Available to facilitate rigging of the unit. Clip Curb (Full Perimeter) Mates to unit. Roof curb can be assembled using interlocking tabs to fasten corners together. No tools required. Available in 8 and 4 inch heights. Shipped knocked down. Adjustable Pitch Roof Curb (Full Perimeter) Fully adjustable pitch curb provides a level platform for packaged units allowing flexible installations on roofs with sloped or uneven angles. Adjustable from / to 6/ pitch. Unit hold-down brackets secure packaged unit to curb. Constructed of heavy-gauge galvanized steel with fully welded seams and corners. Rounded corners on flange prevent damage to roof shingles. Built-in drip edge. IAPMO/UMC listed. CBC 03 compliant (California). Seismic rating - Ss=3.73 Ip=.5, wind rating - 55mph. Maximum load rating 800 lbs. LRP4AC - to 5 Ton Packaged Electric / Electric / Page 3

FEATURES CONTROLS Electronic blower control. Single pole contactor. Trade available components. 4 Volt Transformer 40VA transformer furnished and factory installed in control area. Optional Accessories icomfort M30 Smart Wi-Fi Thermostat Wi-Fi-enabled, electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/ Cool. Auto-changeover. Dual-fuel control with optional outdoor sensor. Controls dehumidification during cooling mode and humidification during heating mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy to read 4.3 in. color touchscreen (measured diagonally). LCD display with backlight shows the current and set temperature, time, inside relative humidity, system status (operating mode and schedules) and outside temperature (optional outdoor sensor required). Smooth Setback Recovery starts system early to achieve setpoint at start of program period. Compressor short-cycle protection (5 minutes). Up to four separate schedules are available plus Schedule IQ. One-Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away. Smart Away - Uses geo-fencing technology to determine when the homeowner is within a predetermined distance from the home to operate the system when leaving, away and arriving. Amazon Alexa-enabled, smart-home-compatible. It works with Amazon Echo, Echo Dot and Tap devices. Wi-Fi remote monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. See the icomfort M30 Smart Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. ComfortSense 7500 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/ Cool. Auto-changeover. Dual-fuel control with optional outdoor sensor. Controls dehumidification during cooling mode and humidification during heating mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. See the ComfortSense 7500 Product Specifications bulletin in the Controls section for more information. Remote Outdoor Temperature Sensor Used with the icomfort M30 Smart Thermostat or ComfortSense 7500 Touchscreen Thermostat. When installed outdoors, sensor allows thermostat to display outdoor temperature. Sensor is auto-detected when connected to thermostat. Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. LRP4AC - to 5 Ton Packaged Electric / Electric / Page 4

FEATURES ELECTRIC HEAT (5-0 KW) Field install internal to unit cabinet. Available in several voltages and kw sizes. Helix wound nichrome heating elements exposed directly in air stream resulting in instant heat transfer, low element temperatures and long service life. Cutoff limit control provides positive protection in case of excessive temperatures. Factory assembled with controls installed and wired. AIR FILTER OPTIONS (required) Filters are not furnished - must be field provided. Internal Filter Rack Kits Available for in. thick filters. Kit contains filter rails for mounting filters internal to unit. Filters must be field provided. Filters are available separately. Single Point Power Kits Control Box used with optional electric heat when single power supply is connected to multi-circuit electric heat. SPECIFICATIONS General Data Model No. LRP4AC4 LRP4AC30 LRP4AC36 LRP4AC4 LRP4AC48 LRP4AC60 Nominal Tonnage.5 3 3.5 4 5 Cooling Performance Total cooling capacity - Btuh,600 8,400 34,000 40,000 46,000 57,000 Total unit watts 055 580 3090 3635 480 580 SEER (Btuh/Watt) 4.00 4.00 4.00 4.00 4.00 4.00 EER (Btuh/Watt).00.00.00.00.00.00 Sound Rating Number (db) 78 78 78 78 78 78 AHRI Reference No. 7845700 784570 784570 7845703 7845704 7845705 Refrigerant Type R-40A R-40A R-40A R-40A R-40A R-40A Charge 4 lbs. 6 oz. 4 lbs. 3 oz. 4 lbs. 5 oz. 6 lbs. oz. 6 lbs. 0 oz. 7 lbs. 3 oz. Condensate drain size (fpt) - in. 3/4 3/4 3/4 3/4 3/4 3/4 Outdoor Coil Fan Indoor Blower Motor horsepower /6 /6 /6 /4 /4 /4 Diameter - in. & No. of blades - 4-4 - 4 4-3 4-3 4-3 Blower wheel size dia. x width - in. 0 x 6 0 x 6 0 x 8 0 x 0 0 x 0 x 9 Motor horsepower /3 /3 /3 /3 / Net weight of basic unit - lbs. 33 343 35 44 48 467 Shipping weight of basic unit ( Pkg.) - lbs. 394 406 44 497 50 540 Electrical characteristics (60 hz) 08/30V-ph-60hz AHRI Certified to AHRI Standard 0/40; 95 F outdoor air temperature, 80 F db/67 F wb entering evaporator air. Sound Rating Number rated in accordance with test conditions included in AHRI Standard 70. LRP4AC - to 5 Ton Packaged Electric / Electric / Page 5

OPTIONAL ACCESSORIES - ORDER SEPARATELY Model No. LRP4AC4 LRP4AC30 LRP4AC36 LRP4AC4 LRP4AC48 LRP4AC60 Compressor Crankcase Heater X7 Compressor Hard Start Kit 0J4 88M9 Compressor Timed-Off Control 47J7 Downflow Conversion Kit (includes drain pan overflow switch) U80 U8 Drain Pan Overflow Switch U75 Electric Heat Size - 08/40V-ph Internal Filter Rack Kit (filters not furnished) 5 kw - PHK05BP 0W47 7.5 kw - PHK07BP 0W48 0 kw - PHK0BP 0W49 5 kw - PHK5BP 0W50 0 kw - PHK0BP 0W5 () 0 x 0 + () 4 x 0 U73 () 0 x 0 U74 Lifting Brackets U76 Clip Curbs 8 in. Height 4W7 4W7 4 in. Height 4V68 4V69 Adjustable Pitch Roof Curb Y7975 Single Point Power Kits For 5 kw Electric Heat ASPWR83- For 7.5 kw Electric Heat ASPWR84- For 0 kw Electric Heat ASPWR85- For 5-0 kw Electric Heat ASPWR86- CONTROLS - ORDER SEPARATELY Y7976 3W88 3W89 3W90 3W9 icomfort M30 Smart Wi-Fi Thermostat 5Z69 ComfortSense 7500 Thermostat 3H4 Remote Outdoor Temperature Sensor X658 Filters are not furnished and must be field provided. Remote Outdoor Temperature Sensor is used with residential packaged units. Allows the thermostat to display outdoor temperature. LRP4AC - to 5 Ton Packaged Electric / Electric / Page 6

ELECTRIC HEAT CAPACITIES Input Voltage No of Steps 5 kw 7.5 kw 0 kw 5 kw 0 kw kw KBtuh No of Input Output Steps kw Input KBtuh No of Output Steps kw KBtuh Input Output No of kw KBtuh Steps Input Output No of kw Steps Input KBtuh Output 08 3.8.8 5.6 9. 7.5 5.6. 38. 5 5. 0 4. 4.3 6.3.5 8.4 8.7.6 43 6.8 57.3 30 4.6 5.7 6.9 3.5 9. 3.3 3.8 47 8.4 6.7 40 5 7. 7.5 5.6 0 34. 5 5. 0 68. ELECTRICAL/ELECTRIC HEAT DATA Model No. LRP4AC4 LRP4AC30 LRP4AC36 Line voltage data - 60hz - phase 08/30V 08/30V 08/30V Compressor Rated Load Amps..8 4. Outdoor Fan Motor Locked Rotor Amps 60.8 64 7. Full Load Amps.0.0.0 Locked Rotor Amps.9.9.9 Indoor Blower Motor Maximum Overcurrent Protection Maximum Overcurrent Protection with Optional Single Point Power Supply Minimum Circuit Ampacity Full Load Amps.7.7.0 Locked Rotor Amps 3.9 3.9 4.4 Voltage 08V 40V 08V 40V 08V 40V Unit Only Circuit 5 5 30 30 30 30 5 kw Circuit 5 30 5 30 5 30 7.5 kw Circuit 40 45 40 45 40 45 0 kw Circuit 50 60 50 60 50 60 3 5 kw Circuit - - - - - - 50 60 50 60 Circuit - - - - - - 5 30 5 30 5 kw 5 30 30 30 30 30 7.5 kw 40 45 40 45 40 45 0 kw 50 60 50 60 50 60 5 kw - - - - - - 70 80 70 90 Unit Only Circuit 6.7 6.7 8.7 8.7 0.6 0.6 5 kw Circuit 4.3 7.7 4.3 7.7 4.6 8 7.5 kw Circuit 35.6 40.8 35.6 40.8 35.9 4. 0 kw Circuit 46.8 53.8 46.8 53.8 47. 54. 3 5 kw Circuit - - - - - - 46.8 53.8 47. 54. Minimum Circuit Ampacity with Optional Single Point Power Supply NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. NOTE - Circuit Minimum Circuit Ampacity includes the Blower Motor Full Load Amps. NOTE- Extremes of operating range are plus and minus 0% of line voltage. HACR type breaker or fuse. Circuit - - - - - -.6 6.6 6 5 kw 4.3 7.7 4.3 7.7 4.6 8 7.5 kw 35.6 40.8 35.6 40.8 35.9 4. 0 kw 46.8 53.8 46.8 53.8 47. 54. 5 kw - - - - - - 69.4 79.8 69.7 80. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 3 A separate compressor circuit is required. LRP4AC - to 5 Ton Packaged Electric / Electric / Page 7

ELECTRICAL/ELECTRIC HEAT DATA Model No. LRP4AC4 LRP4AC48 LRP4AC60 Line voltage data - 60hz - phase 08/30V 08/30V 08/30V Compressor Rated Load Amps 5.9 7.9 3.7 Outdoor Fan Motor Indoor Blower Motor Maximum Overcurrent Protection Locked Rotor Amps 85 96 5.5 Full Load Amps.7.7.7 Locked Rotor Amps 3. 3. 3. Full Load Amps.8.8 7.6 Locked Rotor Amps 5.4 6.8 - - - Voltage 08V 40V 08V 40V 08V 40V Unit Only Circuit 40 40 40 40 60 60 5 kw Circuit 30 30 30 30 35 35 7.5 kw Circuit 40 45 40 45 45 50 0 kw Circuit 50 60 50 60 60 60 3 5 kw Circuit 50 60 50 60 60 60 Circuit 5 30 5 30 60 60 3 0 kw Circuit 50 60 50 60 60 60 Circuit 50 60 50 60 60 60 Maximum Overcurrent Protection with Optional Single Point Power Supply Minimum Circuit Ampacity 5 kw 40 40 40 40 60 60 7.5 kw 40 45 40 45 60 60 0 kw 50 60 50 60 60 60 5 kw 80 90 80 90 80 90 0 kw 00 0 00 0 00 5 Unit Only Circuit 4.4 4.4 6.9 6.9 38.9 38.9 5 kw Circuit 5.4 8.8 5.4 8.8 30. 33.6 7.5 kw Circuit 36.7 4.9 36.7 4.9 4.5 46.7 0 kw Circuit 47.9 54.9 47.9 54.9 5.7 59.7 3 5 kw Circuit 47.9 54.9 47.9 54.9 5.7 59.7 Minimum Circuit Ampacity with Optional Single Point Power Supply Circuit.6 6.6 6.6 6 3 0 kw Circuit 47.9 54.9 47.9 54.9 5.7 59.7 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. NOTE - Circuit Minimum Circuit Ampacity includes the Blower Motor Full Load Amps. NOTE- Extremes of operating range are plus and minus 0% of line voltage. HACR type breaker or fuse. Circuit 45. 5. 45. 5. 45. 5. 5 kw 5.4 8.8 6.9 8.8 38.9 38.9 7.5 kw 36.7 4.9 36.7 4.9 4.5 46.7 0 kw 47.9 54.9 47.9 54.9 5.7 59.7 5 kw 70.5 80.9 70.5 80.9 75.3 85.7 0 kw 93 07 93 07 97.8.8 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 3 A separate compressor circuit is required. FIELD WIRING THERMOSTAT (Optional) A B SINGLE PACKAGE UNIT DISCONNECT SWITCH (Not Furnished By Lennox) A Five Wire Low Voltage (Electronic) B Two Wire Power (See Electrical Data Table) If multiple disconnects are used on units with electric heat; there must be two wire power provided for each disconnect Field Wiring Not Furnished LRP4AC - to 5 Ton Packaged Electric / Electric / Page 8

COOLING RATINGS Model No. Indoor Temp DB/WB ºF Outdoor Temperature - DB 65 F 8 F 95 F 05 F 5 F Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw 85/7 3,700 0.6.45 9,00 0.63.73 7,00 0.64.95 5,000 0.7.3,900 0.78.3 LRP4AC4 80/67 8,600 0.68.45 5,700 0.7.7 3,600 0.73.98,00 0.78.5 0,900 0.84.33 75/63 6,00 0.70.46 4,000 0.7.75,300 0.75.96 0,800 0.8.5 9,400 0.87.34 75/57,400.00.46 0,800.00.75 9,600.00.98 9,00.00.6 8,700.00.35 85/7 36,800 0.64.80 34,00 0.65. 3,00 0.66.35 9,800 0.7.6 7,300 0.77.87 LRP4AC30 80/67 33,00 0.7.78 3,400 0.7.07 8,900 0.73.34 6,900 0.78.60 4,800 0.84.87 75/63 30,000 0.76.78 8,00 0.75.09 6,800 0.75.34 5,00 0.8.6 3,300 0.88.88 75/57 7,500.00.79 5,000.00. 3,00.00.35,900.00.6,600.00.87 85/7 45,000 0.68.0 4,300 0.67.58 38,400 0.67.87 36,00 0.7 3.9 33,700 0.76 3.50 LRP4AC36 80/67 4,00 0.73.0 37,400 0.73.53 34,500 0.76.86 3,800 0.79 3.8 3,00 0.8 3.50 75/63 38,500 0.75.9 35,300 0.78.58 3,900 0.80.87 3,000 0.83 3.8 9,00 0.85 3.49 75/57 35,500.00.9 33,000.00.57 3,000.00.87 9,500.00 3.8 7,900.00 3.49 85/7 53,600 0.63.66 50,00 0.65 3.4 47,600 0.67 3.5 43,600 0.73 3.84 39,500 0.79 4.8 LRP4AC4 80/67 50,00 0.69.65 46,000 0.73 3.08 4,700 0.75 3.50 39,500 0.8 3.84 36,300 0.87 4.9 75/63 47,00 0.73.64 4,800 0.76 3.0 39,500 0.79 3.45 36,600 0.84 3.8 33,800 0.89 4.0 75/57 4,800.00.63 38,500.00 3.09 35,300.00 3.44 34,000.00 3.8 3,700.00 4.0 85/7 64,900 0.63 3.5 58,00 0.66 3.63 53,00 0.69 3.99 48,600 0.74 4.38 44,00 0.78 4.76 LRP4AC48 80/67 59,00 0.7 3.04 5,300 0.73 3.5 47,500 0.76 3.97 44,00 0.8 4.36 40,800 0.87 4.76 75/63 53,00 0.74 3.0 47,400 0.78 3.5 4,900 0.8 3.89 40,500 0.85 4.3 38,000 0.89 4.75 75/57 46,500.00.99 4,00.00 3.49 38,700.00 3.87 37,800.00 4.3 36,800.00 4.75 85/7 70,300 0.63 3.50 66,00 0.64 4.9 6,800 0.65 4.7 59,00 0.70 5.7 55,500 0.76 5.8 LRP4AC60 80/67 65,700 0.69 3.47 6,000 0.7 4.08 57,400 0.73 4.69 54,300 0.78 5.4 5,00 0.83 5.78 75/63 6,400 0.7 3.45 56,300 0.74 4. 5,300 0.76 4.63 50,00 0.80 5.9 48,000 0.85 5.75 75/57 54,500.00 3.4 50,00.00 4.09 46,700.00 4.6 46,300.00 5.7 45,900.00 5.73 INSTALLATION CLEARANCES in. mm Front (heat exchanger access) 4 60 Right Side (blower access) 4 60 Left Side (evaporator coil access) 4 60 Back 0 0 Top 48 9 LRP4AC - to 5 Ton Packaged Electric / Electric / Page 9

BLOWER DATA LRP4AC4 AND LRP4AC30 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume at Specific Blower Taps (cfm) Tap Tap 3 Tap 4 Tap 5 0.0 350 0 970 840 0.0 30 080 950 80 0.30 70 050 90 800 0.40 0 000 890 770 0.50 40 970 850 750 0.60 080 90 80 70 0.70 00 870 770 680 0.80 950 800 70 60 NOTE - All air data measured external to unit with dry coil and less filter. LRP4AC36 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume at Specific Blower Taps (cfm) Tap Tap 3 Tap 4 0.0 550 340 0 0.0 500 30 080 0.30 440 60 050 0.40 370 0 00 0.50 300 50 960 0.60 30 080 900 0.70 30 990 80 0.80 00 870 660 NOTE - All air data measured external to unit with dry coil and less filter. LRP4AC4 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume at Specific Blower Taps (cfm) Tap Tap 3 Tap 4 0.0 790 500 070 0.0 740 470 050 0.30 670 430 00 0.40 590 370 980 0.50 50 30 90 0.60 40 40 870 0.70 30 40 80 0.80 0 00 690 NOTE - All air data measured external to unit with dry coil and less filter. LRP4AC - to 5 Ton Packaged Electric / Electric / Page 0

BLOWER DATA LRP4AC48 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume at Specific Blower Taps (cfm) Tap Tap 3 Tap 4 0.0 970 730 50 0.0 890 690 480 0.30 790 600 430 0.40 690 540 370 0.50 600 450 30 0.60 50 360 30 0.70 400 70 40 0.80 80 50 050 NOTE - All air data measured external to unit with dry coil and less filter. LRP4AC60 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume at Specific Blower Taps (cfm) Tap Tap Tap 3 Tap 4 (Low Static Electric Heat) Tap 5 (High Static Electric Heat) 0.0 40 90 400 90 - - - 0.0 00 870 30 870 - - - 0.30 40 80 60 80 - - - 0.40 00 770 00 770 - - - 0.50 060 70 0 - - - 0 0.60 00 670 060 - - - 060 0.70 980 450 980 - - - 980 0.80 950 360 900 - - - 900 NOTE - All air data measured external to unit with dry coil and less filter. Taps 4 and 5 are used with Optional Electric Heat. Refer to Electric Heat nameplate for proper heat tap selection. LRP4AC - to 5 Ton Packaged Electric / Electric / Page

DIMENSIONS - UNIT - INCHES (MM) (5) 46-3/4 (87) -/ (9) DOWNFLOW SUPPLY AIR OPENING DOWNFLOW RETURN AIR OPENING 3-/4 (83) F E (5) B TOP VIEW HORIZONTAL SUPPLY AIR OPENING 4-/4 (36) HORIZONTAL RETURN AIR OPENING 7 (43) A G 3-/4 (83) H 3-/8 (79) 3-/ (89) 8-/8 (06) POWER ENTRY -/8 (9) DIA. KNOCKOUT LOW VOLTAGE ENTRY 7/8 () DIA. KNOCKOUT ELECTRIC HEAT POWER ENTRY CONDENSATE DRAIN 3/4 NPT 8-/8 (460) -3/4 (70) C D C -/4 (57) BACK VIEW RIGHT SIDE VIEW -3/4 (34) Model No. A B C D E in. mm in. mm in. mm in. mm in. mm LRP4AC4, 30, 36 36-7/8 937 46-3/4 87 3-3/8 340 5-7/8 49 6-3/4 45 LRP4AC4, 48, 60 40-7/8 038 55-/4 403 8-/8 467 4-5/8 7 9-3/4 50 Model No. F G H in. mm in. mm in. mm LRP4AC4, 30, 36 4 356 8-/8 74 -/8 56 LRP4AC4, 48, 60 9-/ 495 3-/8 86 6-/8 664 LRP4AC - to 5 Ton Packaged Electric / Electric / Page

DIMENSIONS - ACCESSORIES - INCHES (MM) CLIP CURB 44-5/8 (33) 0 (54) C 33 (838) Unit Mounting Brackets (4) B A SUPPLY OPENING F -7/8 (48) G Insulated Pan Unit Mounting Brackets (4) 8 (03) 4 (356) 8 (03) E RETURN OPENING 3-/8 (79) -5/8 (95) 33 (838) 4 (0) 44 (8) D TYPICAL FLASHING DETAIL WOOD NAILER CURB FRAME COUNTER FLASHING (FIELD SUP PLIED) NOTE - Roof deck may be ommitted within confines of curb. ROOFING FELT (FIELD SUP PLIED) RIGID IN SU LA TION (FIELD SUP PLIED) CANT STRIP (FIELD SUP PLIED) Usage A B C D E in. mm in. mm in. mm in. mm in. mm 4, 30, 36 44-5/8 33 43 09 8 457 44 8 37 940 4, 48, 60 53-/8 349 5 95 4 60 5-/ 334 4 04 Usage F G in. mm in. mm 4, 30, 36 4 356 6-3/4 45 4, 48, 60 9-/ 495 9-3/4 50 LRP4AC - to 5 Ton Packaged Electric / Electric / Page 3

DIMENSIONS - ACCESSORIES - INCHES (MM) ADJUSTABLE PITCH ROOF CURB FRONT FLANGE 8 in. (03 mm) MINIMUM HEIGHT 4 in. (0 mm) DECK PAN UNIT HOLD DOWN BRACKET (4) C B A (5) TYP ADJUSTABLE FROM / to 6/ PITCH SIDES AND BACK FLANGE 6 in. (5 mm) D E F 46-/ (8) (305) 7 (43) SUPPLY OPENING RETURN OPENING 4 (0) G Usage A B C D in. mm in. mm in. mm in. mm 4, 30, 36 47 94 34-/ 876 5 7 33-3/4 857 4, 48, 60 55-/4 403 4-3/8 076 0 54 33 838 Model No. E F G in. mm in. mm in. mm 4, 30, 36 4-/ 368 8-3/4 476 8 457 4, 48, 60 0 508 -/8 537 8-/4 464 LRP4AC - to 5 Ton Packaged Electric / Electric / Page 4

REVISIONS Sections Blower Data Optional Accessories Specifications Description of Change Blower data updated for LRP4AC36. Added icomfort M30 Smart Wi-Fi Thermostat. Added AHRI Reference No. Visit us at www.lennox.com For the latest technical information, www.lennoxpros.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 08 Lennox Industries, Inc.