METEOROLOGICAL INSTRUMENTS

Similar documents
METEOROLOGICAL INSTRUMENTS

METEOROLOGICAL INSTRUMENTS

MODEL MARINE WIND TRACKER

MODEL WIND TRACKER

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

TEC2100 Series Networked Thermostats

field SENSE EC-FS2-001-A

Mark 25 Ultrapure Water Conductivity Analyzer

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Rev D 3/20/17

Laboratory Airflow Monitors & Controls TYPE C STANDARD & NIGHT SETBACK LED & DIGITAL - VAV SYSTEMS

TEC210x-2 Series Networked Thermostats

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

TLM-1 TOWER LIGHT MONITOR V3.0. INSTALLATION and OPERATING INSTRUCTIONS

Software Version 2.01 LEVEL MONITOR MODEL 220

TEC1100 Series Thermostats

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

SEE DISCLAIMER ON REVERSE

Wireless High Bay Sensor (WHS100) Installation Instructions

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

WIO200 Water In Oil measuring instrument

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

Carbon Monoxide Transmitter

WatchDog Wireless Crop Monitor Operation Manual

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

AirGard 385 Fume Hood Monitor

ECO N DATE DESCRIPTION OF CHANGE CHG

Sierra Model 951 Digital Flo-Box. Instruction Manual Part Number IM-951 Revision A 09-05

EXPERT TRI-STAR. Temperature controller. User s Manual

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

Snifter ATEX22 VERSION. User Manual. Distributor

Model SWH-4000 Multi-Technology Mullion 125 KHz and MHz (Flex) Reader Installation Guide. Version A0 Part Number UM-104 September 2005

Sintrol Snifter A2 EX. Manual. Version 1.2.3

International ECO Door Controller Installation Guide

CO Guardian LLC Document: E. AIRPORT DRIVE Date: 11/15/05 OWNERS MANUAL

Emotron M10 Shaft Power Monitor. Instruction manual English

Operation and Maintenance Manual OM 897-3

Pioneer-R16 Gas Monitor Operator s Manual

IFS Fiber Module Installation & Operation Instructions

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

ENGINE MONITOR VOTT MODEL: YEAR WARRANTY

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

RS Pro Infrared Temperature Sensor

Keysight U8030A Series Triple Output DC Power Supply

Model SWH-3000 Proximity Multi-Frequency 125KHz & 13.56MHz (Fixed) Reader Installation Guide. Version A0 Part Number UM-102 September 2005

R Series Remote Annunciators and Expander Installation and Operation Guide

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

IFS Fiber Module Installation & Operation Instructions

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

Sintrol Snifter A1+ Manual. Version 1.2.2

Alarm Tone Generator Model AG17

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

Pump-Down Controller MODEL 4052

Nuclear Associates

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

ECA-DIN. Users Manual. Current and Voltage Alarms. March 2018

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

REC-8R Environmental Control. Operation and Installation Manual

20 Light Remote Annunciator

Process & TeMPerATUre UniversAl input DigiTAl MeTers

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

Section PERIMETER SECURITY SYSTEMS

ESSEX ENGINEERING CORPORATION

CRITICAL ENVIRONMENT MONITOR ALNOR AIRGARD 350 CEM

Dual Input Toroidal Analyzer

Document No

I/A Series 716C 1/16 DIN Temperature Controller

Installation and ZONES: Operation Manual. Model: ON STI-34108

Pet Immune SAW PIR Motion Sensor

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

VX SERIES Wireless Thermostat with Occupancy Sensor

VA301C CONTROLLER WITH BACnet OPTION

WIO200 Water in oil sensor

APC BC300 Series 40kW 208/450/480V User Guide

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

Model 1062 Environment Monitor

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

RS485 MODBUS Module 8AI

AUTOMATION. Operator s Manual RST Series Web Enabled Input Module. Rev. A2, 1/12

Technical Manual. Level Alarm Unit CARLA & WIDS

Beacon 800 Gas Monitor Operator s Manual

Ethernet General Purpose

Wireless External Alarm

IFS Fiber Module Installation & Operation Instructions

F4 Process Controller Installation and Operation Guide

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Booster Power Supply Manual

Performance Thermal Binder

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

Transcription:

METEOROLOGICAL INSTRUMENTS INSTRUCTIONS WIND TRACKER MODEL 06206 R.M. YOUNG COMPANY 2801 AERO PARK DRIVE, TRAVERSE CITY, MICHIGAN 49686, USA TEL: (231) 946-3980 FAX: (231) 946-4772 WEB: www.youngusa.com PN: 06206-90 REV: I111215

MODEL 06206 WIND TRACKER INTRODUCTION The YOUNG Model 06206 Wind Tracker is a compact wind speed and direction display with advanced features such as relative wind angle and NMEA serial I/O making it suitable for shipboard use. FEATURES 3-digit wind speed display 3-digit maximum wind speed or wind direction display Multi-color wind direction display with variability Wind speed and direction alarms with delay RS-485/NMEA serial connections Calibrated 0-5 VDC outputs Display brightness control Compatible with YOUNG wind sensors & 4-20mA inputs PRECAUTIONS SPECIFICATIONS Size: Panel Cutout: 144 mm (5.65 in) x 144 mm (5.65 in) x 36 mm (1.4 in) 138 mm (5.43 in) x 138 mm (5.43 in) Sensors: Wind Monitor-MA (05), Wind Monitor (05), Wind Monitor HD (Hd), Wind Monitor-SE (SEr), Ultrasonic Anemometer (SEr), Wind Monitor-JR (04), Wind Sentry (03) Accuracy: ±0.6% Full Scale NMEA Serial Input & Output: $WIMWV, ddd, R, sss, u, A*c<cr><lf> ddd wind direction in degrees sss wind speed (ss.s for m/s) u units (N knots, K km/hr, M m/s, S statute mph) c NMEA checksum Other inputs: 4-20 ma (0-360 deg, Ldi 0-50 m/s, Ld2 0-100 m/s) Other outputs: 0-5 VDC = 0-360 or 0-540 0-5 VDC = 0-100 m/s Alarm Relays: Input Power: Weight: Normally Open contacts for WS and WD Contact rating 24 VAC or 30 VDC maximum 5A resistive, 2A inductive maximum 12-30 VDC, 3.5 W 1.0 lb (0.45 kg) without AC adapter INDOOR USE ONLY! (Unless placed in approved enclosure) Operating temperature range: 0-50 C (32-122 F), 0-95% RH Use only recommended power sources. (12-30 VDC, 3.5 W ) Disconnect power when connecting or servicing Alarm contact rating 24 VAC/30 VDC, (5 A resistive, 2 A inductive maximum) MOUNTING AND START-UP 1. For best visibility, place the Wind Tracker in a location free of direct sunlight. Mount it using the attached bracket or remove bracket for flush mounting to a bulkhead or panel cutout. Panel cutout dimensions are given in the specifications. An optional rack mounting panel (Model 06280) and protective enclosure (Model 06260) are available from your YOUNG supplier. 2. Connect cables to terminals according to wiring diagram. IMPORTANT NOTE! Please observe correct position of back panel Input Selector Switch according to wiring diagram. 3. Connect GND terminal to suitable earth ground. 4. Insert power supply plug into power jack, plug power supply into a suitable AC wall outlet or connect to suitable 12 to 30 VDC power source to terminals. IMPORTANT NOTE! Do not connect more than one power source to the Wind Tracker at the same time. 5. When power is applied, the Wind Tracker will display firmware version number then begin to display wind information as follows: Wind speed Wind speed units Maximum wind speed or direction degrees Wind direction (single orange indicator) Direction variability (green indicators) Alarm status indicators (if selected) Wind speed & direction averaging indicator (if selected) 6. Observe display to confirm proper operation. Page 1

FRONT PANEL FACTORY DEFAULT SETTINGS INPUT: - Sensor Input Setting: "05" Wind Monitor - Input selector switch position: "Down" (Sensor) OPTIONS: - Averaging: "No" - Right hand display window: "Max Wind Speed" - Alarms: "No" OUTPUT: - Voltage Outputs: 0-5Vdc=0-100m/s / 0-5Vdc = 0-360 - NMEA Serial Output Rate: "FST" IMPORTANT NOTE!: Before connecting any external devices, verify the above settings are compatible with your application. If different, refer to the wiring diagrams in the back of the manual for the correct settings. CHANGING SETTINGS 1. Wind speed display 2. Wind speed units indicator 3. Alarm status indicators 4. Data averaging indicator 5. Maximum wind speed or direction display 6. Wind direction and variability display 7. Brightness control (operate) or Enter key (setup) 8. Maximum Reset (operate) or Select (setup) BACK PANEL Marine Wind Tracker parameters may be inspected or changed in SETUP mode which is enabled by simultaneously pressing both ENTER and SELECT keys for about 4 seconds. When SETUP mode is active, abbreviations identify each function and available options as listed below. The SELECT key changes options or values. The ENTER key saves and moves to the next parameter. Appearance of options depends on parameter settings. Some options may be hidden. DISPLAY SETUP FUNCTION Input / Sensor Type InP 03 Wind Sentry 04 Wind Monitor-Jr 05 Wind Monitor SEr NMEA serial input Ld2 Line Driver 4-20mA input (0-100 m/s) Hd Wind Monitor HD Ldi Line Driver 4-20mA input (0-50 m/s) Wind Speed Units (annunciator blinks) SPd unt SELECT key changes units. ENTER to save NMEA Serial Output Rate Out FSt 16 times per second SLO Once per second Display Averaging (annunciator blinks) dsp no Instantaneous data displayed YES Average data displayed PEr 030 Set averaging period in seconds (0-999). Display will update at this interval. 1. Power input coaxial jack (12-30 VDC) 2. Power input terminals (12-30 VDC) 3. Sensor or 4-20 ma inputs 4. Earth ground connection 5. RS-485 serial input/output 6. 0-5 VDC calibrated outputs 7. Alarm relay connections (Normally Open) 8. Input Selector Switch (Sensor or 4-20mA) Right Display Window Selection dsp SPd Maximum wind speed dir Wind Direction degrees Wind Direction Alarm (annunciator blinks) ALr no Direction alarm not armed YES Direction alarm armed ALr dir SELECT key sets direction alarm sector start. ENTER key saves. ALr SPn SELECT key sets direction alarm sector span. ENTER key saves. Page 2

Wind Speed Alarm (annunciator blinks) ALr no Speed alarm not armed YES Speed alarm armed ALr 000 Alarm set-point. SELECT key increments value. ENTER key saves. Alarm Delay Time dly 030 Alarm delay time in seconds (0-999). SELECT key increments value. ENTER key saves. Sound Snd no No sound YES Audible beep with alarm activations or average update. Wind Direction Voltage Output Scale dir 360 0-360 degrees 540 0-540 degrees Test Functions tst no No test YES Test tst ALr SELECT key closes alarm relays. CAL 0.00 SELECT key alternates between 0.00 and 5.00 VDC output to calibrate external devices. tst dsp SELECT key tests display sections. OPERATION ALARMS Wind speed and direction alarms each have their own set-point, LED status indicator, and relay contacts. The Alarm Delay parameter establishes time duration in or out of the set-point range needed for the alarm to change state. Front panel LEDs indicate alarm status during operation. LED Off LED Steady LED Blinking = Alarm not armed and OFF. Relay open = Alarm armed and OFF. Relay open = Alarm armed and ON. Relay closed. Audible beep if Sound parameter is enabled. Connect one Wind Tracker master to up to 16 remote displays via the RS-485 terminals as shown in wiring diagrams. Remote Wind Trackers display exactly the same information as the master including alarm states. MAX RESET and all display features are controlled by the master unit only. Brightness can be adjusted independently at each Wind Tracker display. VOLTAGE OUTPUTS Calibrated voltage outputs for wind speed and direction are updated 16 times per second. Wind Speed 0-100 m/s = 0.00 to 5.00 VDC. Wind Direction may be scaled for either 0-360 or 0-540 degrees = 0.00 to 5.00 VDC by setting the Direction (dir) parameter. 4-20 ma INPUTS The Wind Tracker accepts 4-20 ma Line Driver inputs with either 0-50 m/s or 0-100 m/s scaling (Ldi and Ld2 input settings). Connect as shown in wiring diagram. The back-panel switch labeled 4-20 ma must be in the UP position. 24VDC power is recommended for most 4-20 ma installations. POWER CONNECTIONS The Wind Tracker operates from a 12 to 30 VDC power source. Power may be connected via the coaxial jack or terminals. These are internally wired in together so DO NOT CONNECT MORE THAN ONE POWER SOURCE AT THE SAME TIME. See wiring diagrams for examples. ERROR MESSAGES Ldi Err 4-20 ma (line driver) signal is missing or outside an acceptable range. Verify connections, signal, and 4-20 ma switch in UP position. SEr Err Unit set to receive RS-485 serial signal (inp=ser), but no serial data detected. Verify NMEA source is working. Verify connections. AVERAGING When averaging is enabled, the front-panel AVG annunciator is illuminated, and average wind speed and direction values are displayed at intervals set by the Period (PEr) parameter. When averaging is disabled, instantaneous wind values are displayed. BRIGHTNESS Adjust display brightness by pressing and holding the left BRIGHT key for 1 second. MAXIMUM or WIND DIRECTION DISPLAY Either MAXIMUM WIND SPEED GUST or numerical WIND DIRECTION appears during operation depending on Right Display Window (dsp) parameter setting. Maximum gust may be reset during normal operation by pressing and holding the RESET key for 1 second. REMOTE DISPLAYS The Marine Wind Tracker may be configured as a remote display by setting the Sensor Input for serial input (InP=SEr) and connecting the RS-485 terminals to a source providing a $WIMWV NMEA wind speed and direction string. This may be any valid NMEA source including another Wind Tracker operating as a master, a Young wind sensor or interface sending the NMEA string, or a shipboard system. With a Marine Wind Tracker as the NMEA source, use these settings: MASTER: Sensor InP = any non-serial device. REMOTE: Sensor InP = SEr Page 3

EMC COMPLIANCE This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. WARRANTY This product is warranted to be free of defects in materials and construction for a period of 12 months from date of initial purchase. Liability is limited to repair or replacement of defective item. A copy of the warranty policy may be obtained from R. M. Young Company. CE COMPLIANCE This product has been tested and complies with European CE requirements for the EMC Directive. Please note that shielded cable must be used. This ISM device complies with Canadian /CES-001. Cet apparei/ism est conforme a Ia norme NMB-001 du Canada. EN55011/CISPR 11, Group 1, Class B device Class B equipment is suitable for use in domestic establishments and in establishments directly connected to a low voltage power supply network which supplies buildings used for domestic purposes. Note: Instrument measurements may be disrupted by conducted RF interference at 13, 35, and 54 MHz. To meet EMC Compliance, a ferrite core (YOUNG 18500) must be installed on the wall adapter DC power cable. The cable must pass through the center hole of the choke at least 4 times, creating 3 loops around the outside as shown below. 18500 FERRITE CHOKE Page 4

WIRING DIAGRAMS WIND SENSOR 05103, 04101, 03002 Page 5

WIRING DIAGRAMS Page 6

WIRING DIAGRAMS SENSOR SETTINGS: Output Mode: RS-485 Output Only Output Format: NMEA Baud Rate: 4800 06206 Wind Tracker with Inp SEr in setup SENSOR SETTINGS: Output Mode: RS-485 Output Only Output Format: NMEA Baud Rate: 4800 06206 Wind Tracker with Inp SEr in setup Page 7

WIRING DIAGRAMS Master-Remote Display Wiring Example Page 8