High Output Vacuum/Pressure Pump

Similar documents
OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

Multiscreen Vacuum Manifold User Guide for ZipPlate micro-spe Plate

USER MANUAL UN-200V / UN-200VH

User Manual. Twin Piston Vacuum Pumps: Oil-less WVP Series: WVP12, WVP10, WVP5, WVP4, WVP3, and WVP2

Thermo Scientific Air Cadet

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2581

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS 2016, 2024, and 8111

OWNER S MANUAL FOR WOB L PISTON VACUUM PUMP MODELS: 2561B B C C C C-25

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: / / / 2047

Refrigerant Recovery Machine. Model No Operating Manual

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2019

MODEL 7000 SUCTION UNIT

OWNER S MANUAL FOR DRY VACUUM PUMP MODELS: 2567B-01, 2567B-50, 2567C-02, 2567C-50

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

OWNER S MANUAL FOR DRY VACUUM PUMP MODELS 2585B-01, 2585B-50, 2585B-55 & 2585Z-50

Instruction Manual Analog Vortex Mixer with Fixed Cup Head

OWNER S MANUAL (English)

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: 2014 / 2032 / 2042 / 2034 / 2044 / 2037 / 2047

Dry, oilfree Diaphragm Pumps

Dry, oilfree Diaphragm Pumps. Highlight NEW MPC 302 Z. 3 Diaphragm Pumps

USER MANUAL SAVE THESE INSTRUCTIONS

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODEL: 2511

High Performance Oilless Residential Light Commercial. Product Leadership Training Service Reliability

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

Operator s Manual. IP-100 Immersion Probe Cooler

HERCULES (110V) (220V) USER S MANUAL

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Aspirator with trap flask FTA-1

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

FTA-1 Aspirator with trap flask

Installation & Operating Guide

Laboport Chemically-resistant Laboratory Pumps and Systems

INSTRUCTION MANUAL. Instruction Manual High Throughput Homogenizer

Installation & Operating Guide

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Booster Compressors N Series. Pressures to 650 psig Capacities 9.5 to 724 cfm

OPERATING MANUAL English Chemical Resistant Diaphragm Pump

Schuco byallied MEDICAL ASPIRATOR. USER'S MANUAL A Caution

OPERATING INSTRUCTIONS

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

LC Series - Light Commercial Pump Station Installation and Operation Manual

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Diaphragm pumps. Operation Manual. Models: 2019C-02 (230V / 50Hz) 2019B-01 (115V / 60Hz) 2019C-50 (230V / 50Hz)

Oil-Sealed Rotary Vane Pumps

OWNER S MANUAL (English)

OWNER S MANUAL FOR CHEMSTAR DRY MODELS: 2070, 2080

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

Series: MBC1-TC Mini Benchtop Temperature Controller

ASPIRE Laboratory Aspirator

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

PowerVac G Single to Twin Conversion Kit [ ]

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg)

Reacti-Therm I and III Heating Modules

Vacuum cleaner Instruction manual

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

Monitored Pneumatic Valves On Series Ported Manifold

MST, INC. MODEL 2002 CARBON MONOXIDE MONITOR OWNER S MANUAL

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

Air Purifier. User s Guide. Important! Oreck Air Purifier with HEPA Filtration. Read this manual carefully, and keep for future reference.

Reacti-Therm I and III Heating/Stirring Modules

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

Environmental Design The tank has separating devices at the exhaust port to prevent oil-spraying and to reduce pollution.

1 L Rotary Vacuum Evaporator Instruction Manual

Models Series Series

Sip Vacuum Cleaner 1400/35 Wet & Dry

Equipment Alert. P-Trap Must Be Installed to Exhaust or Warranty will be Voided. Refer to this Manual for installation Instructions

CC Series VACUUM PUMPS

Cat 5 Pro Vacuum OPERATOR S MANUAL

WHAT ARE THE SPECIFICATIONS FOR THE VACUUM

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

KEEP FOR FUTURE REFERENCE 1 SCFM NOMINAL AIRFLOW SINGLE VACUUM SYSTEM DC-VOLTAGE POWER SYSTEM WITH MANUAL VALVE

BLAST-IT-ALL BUMPER BLASTER

S150 S300 CONSTRUCTION HEATERS. Rev: August 15, 2008 SERVICE AND MAINTENANCE MANUAL No PLEASE RETAIN FOR FUTURE REFERENCE PRODUCTS

Chemical resistant Vacuum Pumps

POWER JET SERIES. IWATA STUDIO SERIES POWER JET SERIES AIR COMPRESSORS IS-900, IS-925 and IS-975

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

USER'S INFORMATION MANUAL

English Manual for Jewelry Casting and Investing The professional choice

PS-2/ES Automated pack & tag machine with IndES fastening system

IWATA STUDIO SERIES MAXX JET AIR COMPRESSOR IS-1000

HEDMAN The HEDMAN Company 189 Gordon St. Elk Grove Village, IL

SAVE THESE INSTRUCTIONS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Bench-Top Vacuum Oven with 28 segments programmable controller

Models Series Series

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

WSU-TFREC Fire Safety Training

CL & CLG Clamp Mount Mixers

Transcription:

High Output Vacuum/Pressure Pump User Guide Catalogue Numbers: WP62 115 60 (115 V, 60 Hz) WP62 220 50 (230 V, 50 Hz, 1.1 A) WP62 100 60 (100 V, 50/60 Hz)

Notice The information in this document is subject to change without notice and should not be construed as a commitment by Millipore Corporation or an affiliated corporation. Neither Millipore Corporation nor any of its affiliated corporations assumes responsibility for any errors that may appear in this document. This manual is believed to be complete and accurate at the time of publication. In no event shall Millipore Corporation or any of its affiliated corporations be liable for incidental or consequential damages in connection with or arising from the use of this manual. 2009 Millipore Corporation. All rights reserved. Millipore and Millex are registered trademarks of Millipore Corporation. The M mark is a trademark of Millipore Corporation. P36512, Rev. E, 05/09

Introduction The Millipore high output vacuum/pressure pump is a continuously-running constant air-flow type unit for use with laboratory equipment. This vacuum/ pressure pump combines the quietness and durability of a diaphragm pump with the performance of a piston-type pump. It compresses air by means of a motor-driven piston. This pump is intended for filtration of liquids or for other continuous or intermittent uses, with all types of filter holders, multi-well devices, manifolds, and other laboratory equipment. CAUTION: Always use the supplied hydrophobic vent filter or a vacuum-flask water trap in conjunction with the pump, as indicated in Figures 1 and 2. Never pump or draw liquids through the pump, as this will damage the pump. The pump has these features: The motor and pump are permanently lubricated. A thermal overload switch with automatic reset protects the motor. Low operating noise is further minimized by rubber feet. A Millex -FA 50 hydrophobic vent filter and 27 in. (69 cm) of 1/4 in. (6 mm) I.D. vacuum tubing are supplied with the pump.

2 www.millipore.com Rules for Safe Operation The motor is thermally protected and will automatically restart unexpectedly when the overload device resets. Do NOT pump flammable or explosive gases or vapors or operate this pump in an atmosphere containing flammable or explosive gases or vapors. Use of this pump in a manner not specifically stated in this user guide may result in severe bodily injury. Read and understand the information in this owner s manual before operating the vacuum/pressure pump. The vacuum/pressure pump should be operated in a dry, clean, and well ventilated area. When the unit is not in use, wrap the power cord around the vacuum/pressure pump and store in a dry place. Do not abuse the cord. Replace the Millex-FA 50 vent filter (SLFA 050 10) if necessary. Inspect hose, plug, and cord for signs of damage before use. Do not use if a deficiency is found. Never operate a damaged unit. Contact Millipore for replacement parts; see Technical Assistance section for details. This vacuum/pressure pump needs no lubrication. Applying oil to any part may result in polluted air delivery to the air-handling equipment and will damage the pump. To operate at maximum efficiency, the pump system must be thoroughly clean. Refer to the Maintenance section for details on properly cleaning the pump. Compressed air blast must never be aimed at anyone because it can cause serious injury. Keep children away. All vacuum/pressure pumps generate heat, even under normal operating conditions. To avoid serious burns, never touch the head parts or tubing during and immediately after operation. When filtering acids, bases, or organic vapors or gases, use the Millipore Chemical Duty Vacuum/Pressure Pump (WP61 115 60, WP61 220 50, WP61 100 60).

High Output Vacuum/Pressure Pump 3 Usage Guidelines Always use the Millex-FA 50 vent filter and 1/4 inch silicone tubing included with the pump when applying vacuum. This will prevent liquids or vapors from entering the pump. A properly attached Millex-FA 50 vent filter is illustrated in Figure 1. For maximum protection of the pump, use the Millex-FA 50 vent filter AND a vacuum trap to protect the pump from vapors and gases. The vacuum trap consists of a 1 liter filtering flask (Millipore cat. no. XX10 047 05), No. 8 stopper (XX10 047 08) and silicone tubing. Additional tubing is available as Millipore cat. no. XX71 000 04. This assembly is illustrated in Figure 2. Never pump or draw liquids through the pump. This will damage the pump. The filter flask and vacuum trap should be emptied after each use. Filter holder Millex-FA 50 filter unit Filter Vacuum flask pump Figure 1. Proper use of Millex-FA 50 filter Filter holder Millex-FA 50 filter unit Filter flask Vacuum trap Vacuum pump Figure 2. Proper use of vacuum trap and Millex-FA 50 filter

4 www.millipore.com Pump Components B A C D Letter A B C D E F G Description Handle Vacuum gauge Pressure gauge Pump head Vacuum valve Pressure valve On/off switch E F G Identification Symbols WARNING ON (Power) OFF (Power) Direction of Pressure Control (Valves)

High Output Vacuum/Pressure Pump 5 How to Use the High Output Vacuum/Pressure Pump The Millipore Vacuum/Pressure Pump is shipped ready for use. See the Specifications section for required operating conditions. CAUTION: The pump is rated for indoor use only. CAUTION: Be sure available power matches unit requirements. A grounded three-conductor AC electrical source is required. Units are available for 115 VAC 60 Hz, 100 VAC 50/60 Hz, or 230 VAC 50 Hz. See the Specifications section for details of electrical supply options available. 1. Unpack the unit and retain all packing material until you verify proper product operation. 2. The unit rests on four vibration isolator pads. Place the unit on a suitable surface, such as a bench, desk, or table. Be sure not to block the ventilation holes located on the motor housing. 3. Select appropriately-sized tubing, according to your application. Use approximately 1/4 in. I.D. tubing to withstand the anticipated pressure or vacuum. CAUTION: During vacuum filtration, use the supplied Millex-FA 50 hydrophobic vent filter, to prevent excessive amounts of liquids or mist from entering the pump (figure 1). For maximum protection, use a vacuum-flask water trap (figure 2). 4. Prepare the necessary equipment or filter holder and connect the tubing to the equipment. Do not connect the tubing to the pump. 5. Plug the power cord into an appropriate electrical source. CAUTION: Do not turn the pump on with equipment or filter holder already attached. If the pump is inadvertently turned on with the tubing fully connected and it does not run, turn off the pump and disconnect the tubing. Restart the pump and then reconnect the tubing. If the pump s thermal overload switch automatically shuts off the motor, disconnect the tubing and allow the pump to cool for at least 10 minutes before restarting. Reconnect the tubing only after the pump is operating. 6. Turn on the pump, using the toggle switch located at the rear of the pump. 7. Connect the tubing from the filter holder or other equipment to the pump and begin your procedure. 8. If using the pump for vacuum: Adjust the vacuum by closing the pressure regulator and opening the vacuum regulator fully (counterclockwise). Slowly tighten down (clockwise) the vacuum regulator until you obtain the desired vacuum reading on the vacuum gauge. If using the pump for pressure: Adjust the pressure by turning the vacuum regulator down fully and opening the pressure fully (counterclockwise). Slowly tighten down (clockwise) the pressure regulator until you obtain the desired pressure reading on the pressure gauge. 9. Turn off the pump when you are finished. Disconnect the tubing first from the pump and then from the filter holder or other equipment.

6 www.millipore.com Maintenance Under normal operating conditions, and using proper handling procedures, the high-output vacuum/pressure pump should provide many hours of trouble-free operation. Millipore dry vacuum/pressure pumps are 100% oil-free. The pump employs a non-lube piston and cylinder. No maintenance is necessary for the bearings. All bearings are sealed and permanently lubricated. Lubrication should not be attempted. The units are built for continuous duty operation with quietness and durability. CAUTION: Do not lubricate any of the parts with oil, grease, or petroleum products. Do not clean with acids, caustics, or chlorinated solvents. Do not replace the connecting rod or motor bearings. Troubleshooting Vacuum Problems Leakage, contamination, and unusual out-gassing are the general causes of problems associated with poor vacuum. To operate at maximum efficiency, a system must be thoroughly clean. If the system is completely clean and free from leaks, and unwarranted vacuum problems still exist, the pump should be checked. A simple criterion for the condition of the pump is the determination of its maximum vacuum capability. This can be accomplished by blocking the intake and reading the vacuum level on the gauge. Pressure Problems Leakage and contamination are the general causes of problems associated with poor pressure. To operate at maximum efficiency, a system must be thoroughly clean. If the system is completely clean and free from leaks, and unwarranted pressure problems still exist, the pump/compressor should be checked by a service technician. Troubleshooting Guide Poor Pumping Speed Poor Pressure Loud Unit Possible Cause Corrective Action Damaged valves Replace flapper valves Debris in valves Remove debris and check for valve damage Damaged O-rings Replace O-rings Loose head Tighten head screws screws Loose fittings Tighten fittings

High Output Vacuum/Pressure Pump 7 Repair Three replacement part kits are available for the high output vacuum/ pressure pump. The accompanying drawing outlines the contents of each of the kits. For further information or for help ordering the correct kit, please contact Millipore Technical Service. Key Description Maintenance Kit WP62 MNT 00 Rebuild Kit (115 V) WP62 RBD NA Rebuild Kit (230 V/100 V) WP62 RBD EU 1 7 2 5 4 1 Handle screws 2 2 2 2 Head screws 4 4 4 3 Head O-ring 1 1 1 4 Pressure regulator assembly 3 6 8 5 Pressure gauge 1 1 6 Vacuum regulator assembly 7 Vacuum gauge 1 1 8 Valve plate assembly (includes flapper [leaf] valves) 1 1 9 10 9 Cylinder O-ring 1 1 1 10 Connecting rod assembly* 1 1 11 Rubber suction feet 11 *The connecting rod assembly shipped with the rebuild kit for the 115 V pump is different from the one shipped with the rebuild kit for the 230 V and 100 V pumps.

8 www.millipore.com Specifications Performance Vacuum Pressure Regulatory Compliance Sound Level Dimensions 27.2 inches of Hg 50 psi continuous, 80 psi intermittent 115 V UL/CSA recognized; 230 V CE compliant 2004/108/EC 2006/95/EC 98/37/EC Less than 60 db(a) WP62 220 50, WP62 115 60 WP62 100 60 Length 8.0 in. (20.3 cm) 7.3 in. (18.5 cm) Width 9.0 in. (22.9 cm) 9.0 in. (22.9 cm) Height 9.8 in. (24.9 cm) 10.2 in. (25.9 cm) Weight (approximate) 11 lbs (5 kg) 14.5 lbs (6.6 kg) Tubing Connectors Stepped 1/4 in. hose barb Materials of Construction Body and pump head Die cast aluminum Pump Type Piston with PTFE seal Leaf valves High grade stainless steel Electrical Specifications 115 V, 60 Hz or 100 V, 50/60 Hz AC shaded-pole, single phase, 1/7 HP motor 3-pronged, grounded cord and plug 230 V, 50 Hz AC Permanent split capacitor, 1/3 HP motor HAR cordage, CEE 7/7 (Schuko) Line voltage limits ±10% of supply voltage Environmental Conditions Temperature 5 C (41 F) to 40 C (104 F) Relative Humidity, Max. 80% for temperatures up to 31 C, decreasing to 50% at 40 C Altitude, Max. 2000 meters Pollution Degree 2, per IEC 664 (indoor usage: lab, office, etc.) Installation Category II, per IEC 624 (local level: appliances, portable equipment, etc.) Air Flow Rates Air flow rates at different vacuum and pressure settings are shown in the next section. For vacuum operation, pump exit pressure is one atmosphere (14.7 psia). To obtain indicated performance, specified operating conditions must be met. Vacuum Flow Rate Pressure Flow Rate mbar in. Hg L/min CFM bar PSIG L/min CFM 1013 0 34 1.2 0 0 34 1.2 840 5 27 0.96 0.5 7.5 34 1.2 670 10 21 0.73 1.0 15 28 1.0 510 15 14 0.48 2.0 29 25 0.9 340 20 7.6 0.27 3.0 44 24 0.83 170 25 2 0.07 5.0 73 17 0.59 98 27.2 0 0 7.0 102 12 0.42

High Output Vacuum/Pressure Pump 9 Product Ordering Information This section lists the catalogue numbers for the High Output Vacuum/ Pressure Pump. See the Technical Assistance section for information about contacting Millipore. You can also buy Millipore products on-line at www.millipore.com. Description Catalogue Number High Output Vacuum/Pressure Pump 115 V, 60 Hz WP62 115 60 230 V, 50 Hz WP62 220 50 100 V, 50/60 Hz WP62 100 60 Replacement Parts Pump Maintenance Kit WP62 MNT 00 includes head O-ring, cylinder O-ring, handle screws, and head screws Pump Rebuild Kit WP62 RBD NA (115V) includes pressure gauge, WP62 RBD EU (100V & 230V) vacuum gauge, valve plate assembly including flapper valves, head O-ring, cylinder O-ring, connecting rod assembly, handle screws, and head screws Millex-FA 50 filter unit, 10/pk SLFA 050 10 Pressure tubing, silicone, 25 ft XX80 000 25 Vacuum tubing, silicone, 4 ft XX71 000 04 Technical Assistance For more information, contact the Millipore office nearest you. In the U.S., call 1-800-MILLIPORE (1-800-645-5476). Outside the U.S., see your Millipore catalogue for the phone number of the office nearest you or go to our web site at www.millipore.com/offices for up-to-date worldwide contact information. You can also visit the tech service page on our web site at www.millipore.com/techservice. Declaration of Conformity Model WP62 220 50 is in conformity with the following directives: Electromagnetic Compatibility (EMC) Directive 2004/108/EC Low Voltage Directive 2006/95/EC Machinery Directive 98/37/EC Warranty The applicable Millipore Warranty and limited liability for products listed in this publication may be found at www.millipore.com (search on Terms and Conditions of Sale ).