Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.!

Similar documents
Technical Information- Dishwasher MDB8750AWB MDB8750AWQ MDB8750AWS MDB8750AWW MDB9750AWB MDB9750AWQ MDB9750AWS MDB9750AWW

JDB4000AWB JDB4000AWQ JDB4000AWS JDB4000AWW MDB5600AWB MDB5600AWQ MDB5600AWS MDB5600AWW

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing.

CAUTION. To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing. MDBTT50AW*

CAUTION All safety information must be followed as provided in this Technical Sheet and in Service Manual RS

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

FOR SERVICE TECHNICIAN S USE ONLY

REPAIR PART DIAGRAMS. Pages: 1-6

Q7100A,C Thermostat Subbases

Q7100A,C,D Thermostat Subbases

CAUTION. No-Load Performance, Controls in Normal Position

Bottom Mount Refrigerator---Technical Information

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 !

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%

Installation Guide. Contractor Hotline:

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

R8182D,E,F,H,J Combination Protectorelay Primary Control and Aquastat Controller

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

Fast Track Troubleshooting

L8151A Triple Aquastat Relay

DryAire DRYING CABINET

ARGO AR SERIES CONTROLS

Q7300H Series 2000 Commercial Thermostat Subbases

TACOTHERM FRESH PETA (C/CL)

CAUTION: ELECTRICAL HAZARD

TACOTHERM FRESH PETA X (C/CL)

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

Q7300L Series 2000 Commercial Thermostat Subbases

MODEL L-1X & L-1X16 Installation & Operations

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

FDJ SERIES Jockey Pump Controllers Features

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

FOR SERVICE TECHNICIAN S USE ONLY

Owner s Manual. Keep with machine for reference PKD24A INSTALLATION & OPERATION. Rev

MODEL GL-X INSTALLATION & OPERATION

AVPTC. Air Handlers 1½ to 5 Tons

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

L7224A,C; L7248A,C,L Oil Electronic Aquastat Controllers

Laundry. Models Shown: ALW880QAW And ALE866SBW

Owner s Manual GLC MANUAL INSTALLATION SERVICE PARTS REV.1.00

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

SERVICE NOTEBOOK BUILT-IN REFRIGERATOR VCSB481 / VCSB482

Image Key Part Number Description Substitution Qty.

Fast Track Troubleshooting

Table Of Contents. Introduction... Page 1. Specifications... Page 2. Diagrams... Page 3. Uncrating... Page 4. Ice Machine...

FOR SERVICE TECHNICIAN S USE ONLY

DIAGNOSTIC GUIDE DAMP DRY TEST

Standard Features. Performance/Capacities

MODEL CMA-180UC SERVICE & PARTS MANUAL Rev 1.10

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

LMR Electric Fire Pump Controllers Features

Bottom Mount Refrigerator Technical Information

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

GLC/GW-100 MANUAL INSTALLATION SERVICE PARTS REV.1.01

WASHING MACHINE SERVICE MANUAL CAUTION READ THIS MANUAL CAREFULLY TO DIAGNOSE PROBLEMS CORRECTLY BEFORE SERVICING THE UNIT.

Water Boilers ME10EN, ME15EN. Table of Contents

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

Customer Service. Washer Service Manual Compiled From , ,

Installation Guide.

AUTOMATIC WASHER STUDY COURSE

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

LMR Electric Fire Pump Controllers Features

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

RANGE. 2600/1950 Watts. 240/208 Volts BAKE ELEMENT /2100 Watts. 240/208 Volts. 90 degree BAKE ELEMENT Watts.

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

EUCC SERIES Upright 24" Conveyor Dual Rinse Dishwashing Machine

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Product Information and Technical Guide

Stainless Steel Condensing Boiler Connection Instructions To Additional Heating Devices

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

FDF Foam Pump Controllers Features

W8703A Damper Interface Module

Shelleybasic. Parts List For Replacements Parts Only Shelleybasic Is No Longer In Production As Of April 2016

EUCCW SERIES Upright 29" Conveyor Dual Rinse Dishwashing Machine

AMABRA04005_AFL_COVER 5/26/04 9:08 AM Page 1 For the latest product information, visit AMANA PRODUCT GUIDE APRIL 2004 Amana Product Gui

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

Service Manual. Modular Crescent Cuber Models KM-1301SAJ-E. hoshizakiamerica.com

Industrial Air Heaters


MODEL L-1X & L-1X16 Installation & Operations

SELECTING A MOTOR MOTORS

L7224A,C; L7248A,C,L Oil and Electric Boiler Electronic Aquastat Controllers

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

Direct Vent Service Manual

28 1/2"* 72.4 cm. (*28 1/2 " to include hinges.) 41 3/4" 106 cm. 27" 68.6 cm. 28 1/2"* 72.4 cm. (includes hinges.) 28 1/2"* 41 3/4" 106 cm

Fast Track Troubleshooting

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10% Temperature Relationship Test Chart.

Heat Pump Water Heater. Table of Contents

Service Manual For MCR27S, MCR48S, MCR72S, MCR27U, MCR48U, MCR72U MCF27U, MCF48U, MCF72U. Visit us on the web at

Transcription:

echnical Information- Dishwasher JD51AWP RJDW7A Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or repair of this unit.! CAUION All safety information must be followed as provided in this echnical Sheet. o avoid risk of electrical shock, personal injury, or death, disconnect power to unit and discharge capacitor before servicing, unless Models JD51AWP RJDW7A Models JD51AWP RJDW7A Power Source Wash cycles * Voltage AC 1 VAC Heavy Wash X Amperage (Single Unit) 15 A Normal Wash X Frequency Hz Light Wash X Motor horsepower 1/3 Rinse Only X Receptacle N/A *Extended Wash X Plug N/A *Quick Wash Dimensions Features X Height overall 33 ½ to 35 ¼ Accuemp X Width 3 1/ Sani Rinse X Depth 3 7/ Extra Rinse Weight *1 Wash Un-crated 5 lbs. Heated Dry X Delay Start X Control Lock *On selected models only September 3 1 15

Component Specifications o avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless Illustration Component est Procedure Results Dishwasher Motor U (Motor Common) to (Motor CW and CCW Main). rotation viewed from shaft end. See section Motor Connections and Diagram for wiring contacts. 3 to Ω 1/3HP 1V/hz,.5 amps, 35 RPM Full Load wattage, 55 watts Locked Rotor 33 Amps Dishwasher imer See imer Chart / Wiring Diagram for troubleshooting. Water valve 1V/hz, 7 watts 1.5 ±.15 gpm at - 1 psi (Float switch) to (Common) 95 Ω (his value assumes the float switch is closed). Vent wax motor PU/ (Vent) to (Common). 9 Ω Dispenser wax motor N (Dispenser) to (Common). Ω September 3 15

Component Specifications o avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless Illustration Component est Procedure Results Motor Relay Coil RELAY imer PK Common PK Push utton Switch See switch matrix for troubleshooting. POSIION CIRCUIRY FUNCION 1 3 5 7 R HEAER DRY OFF HEAER DRY ON EMP SENSE OFF EMP SENSE ON EXEND OFF EXEND ON Legend: " = Circuit Open = Circuit Closed oost hermostat Close on emperature drop @ 135 F ± 5 F (emp) Open on emperature drop @ 15 F ± 5 F (emp) Infinite Ω = Open Ω = Closed Heater 1v/hz, 5 watts ± 5% in air, 3 watts ± 5% in coldwater /K(Heater) to (Common). 1 Ω (his value assumes the high limit thermostat is closed). September 3 3 15

Motor Connections and Diagram o avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless Wire harness Connection plug lue (Common) Gray (Wash) Red (Drain) Yellow (Main) 1/3HP 1V/hz,.5 amps, 35 RPM 15 September 3

imer Chart / Wiring Diagram o avoid risk of electrical shock, personal injury, or death, disconnect power to washer before servicing, unless CAM NO. CAM HROW IMER INFMAION FUNCION DEENS % * 1 1 1 IMER MO CLEAN HEAER DRY MAIN WINDING HEAER EXENDED ACCU EMP CON. DUY WAX MO WAER VALVE WINDING WINDING IME CHAR- 1 SECONDS PER INERVAL 5 1 15 5 3 35 5 5 55 5 CONACS OPEN -1 SECONDS CONACS CLOSED 9-15 SECONDS CONACS OPEN 9-15 SECONDS CONACS OPEN CONACS CLOSED CONACS OPEN C LOSED * ONE SI DED DEEN HOUR MAKE-UP - SEAL / RINSE / EX. AC CU EMP EX. AC CU EMP HEAED DRY HEAED DRY RINSE DRY CYCLE LIGH CYCLE CLEAN - DISPENSE NMAL CYCLE HEAVY OFF RINSE ONLY OFF KEY WIRES NO CONNECED WIRES CONNECED ON SOME MODELS NOE: ALL SWICHES SHOWN IN HE "ON" POSIION * L1 K IMER CONNNEC (WIR E INSERION SIDE) DO SWICH OPEN CL OSED K K EW EXENDED A ACCU EMP HD HEAED DRY IMER MO IMER COL CODE UA K LACK U LUE R ROWN GRAY GN GREEN ANGE PK PINK PU PURPLE RED N AN IE YELLOW NOE: SOME WIRES HAVE SRIPES. SRIPED WIRES ARE LAELED WIH HE SOLID COL FIRS AND HE SRIPE COL S ECOND. EXAMPLE: A RED WIRE WIH A LACK S RIPE WOULD E LAELED K PK 1 R N N DO SWICH U K C WIRE COL IS LUE UNLESS OHERWISE SPECIFIED 1 1 OPEN CLOSED CLEAN FLOA SWICH WAER VALVE 1 1 1 N N OOS H'S R K R EW R R HEAING A K K SELEC SWICH LI MI H'S K K HD K K HEAER VEN MO MAIN RELAY MO CONNEC PU PU U PK U PK September 3 5 15