AQUAMIST Mist Control Center (MCC) Pump Skid Unit. General Description. Technical Data. Page 1 of 8 JANUARY 2016 TFP2270. Worldwide Contacts

Similar documents
Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Technical Data. Minimum Inlet Supply Pressure All MCC Models...0 psi. Minimum Inlet Supply Capacity Match system design calculations

Worldwide Contacts.

Technical Data. Working Pressure Range 20 to 250 psi (1,4 to 17,2 bar)

Technical Data. Approvals The 1-1/2 thru 8 inch (DN40 thru DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

Technical Data. Approvals The 1-1/2 in. to 8 in. (DN40 to DN200) DV-5 Red-E Cabinets are UL Listed and C-UL Listed with the following system types:

DV-5 Red-E Cabinet Integrated Deluge Fire Protection Package. General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP1300. Worldwide Contacts

Model CV-1F Grooved End Swing Check Valves. General Description. Technical Data. Installation. Page 1 of 6 FEBRUARY 2016 TFP1550. Worldwide Contacts

Safer. Smarter. Tyco. I wish I had a flexible FM Approved Water Mist Solution to fit any industrial oil cooker.

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, Dual-Purpose Water Supply, Domestic and Fire Sprinkler System General Description

Worldwide Contacts. Technical Data

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

Technical Data. Sizes 2 12 Inch (DN50 DN300)

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

Technical Data. Sizes 2 in. (DN50) to 16 in. (DN400) Approvals UL and ULC Listed FM Approved

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

Fire Protection Products Technical Data Book Table of Contents, August 2017

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

Care and Maintenance

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Worldwide Contacts.

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

TECHNICAL DATA OBSOLETE

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEU-LECTRIC RELEASE

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

Model QRS Electronic Accelerator (Quick Opening Device) For Dry Pipe or Preaction Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

TECHNICAL DATA. 319a. January 27, 2012

Sprinkler Identification Numbers

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

TECHNICAL DATA DOUBLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC/ PNEUMATIC RELEASE 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Simple On The Outside...

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

TotalPac X Single interlock SUREFIRE system

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

TotalPac 3 Firecyle III Deluge Remote controlled system

Submittal Packages Detailed with Items and Reviewers

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

Sprinkler Identification Number (SIN)

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Sprinkler Identification Numbers

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

TECHNICAL DATA SINGLE INTERLOCKED PREACTION SYSTEM WITH ELECTRIC RELEASE

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

TotalPac X Firecycle III Preaction Double interlock system

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

Pre-Pack INTEGRATED PRE-ACTION SYSTEM

as required for residential sprinklers intended for use in dry pipe systems.

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Deluge & Preac tion Systems

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

ADDITIONAL PRODUCTS 65

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

DOUBLE INTERLOCK, PREACTION SYSTEM WITH ELECTRIC/PNEUMATIC RELEASE

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Water Mist Fire Suppression

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

Transcription:

Worldwide Contacts www.tyco-fire.com AQUAMIST Mist Control Center (MCC) Pump Skid Unit General Description Center (MCC) Pump Skid Unit is a preassembled, self-contained, control center for the Ultra Low Flow AQUA- MIST Systems. The compact skid unit, which has been pre-wired and prepiped, is designed for ease of installation and to reduce time and labor required for field installation. The MCC is factory assembled and functionally tested, ready to connect to the system and an adequate water supply. This unit consists of a positive displacement pump coupled to an electric motor which is factory wired to a full service motor controller. The pump discharge is connected to a pressure regulating loop which redirects unused water to the pump inlet, to a thermal relieving device which provides cooling to the recirculated fluid, and to a pressure relieving loop which will direct water to the pump inlet in the event of a blockage of flow. The MCC is available in six sizes. The MCC-1 and MCC-A are capable of providing a maximum flow rate of 50 gpm (189 lpm); the MCC-2 and MCC-B are capable of providing a maximum flow rate of 100 gpm (378 lpm); the MCC-3 and MCC-C are capable of providing a maximum flow rate of 150 gpm (568 lpm). The MCC is also available with two output pressure settings. The MCC-1, MCC-2 and MCC-3 are set to output a maximum of 250 psi (17,2 bar). The MCC-A, MCC-B and MCC-C are set to output 175 psi (12,1 bar). Technical Data Approvals Center (MCC) Pump Skid Unit is FM Approved as a component of FM Approved TYCO AQUAMIST systems when configured as the wet pipe, deluge, and single interlock preaction system arrangements. These system types are listed in Table A with their Approved applications and Tyco Fire Protection Products (TFPP) Data Sheet numbers. The MCC Pump Skid Unit can also be configured as a double interlock preaction system arrangement that can be used for a performance based design or other non-fm Approved applications. All cabinets, skids, and enclosures which incorporate Approved components, as well as commercial-off-the-shelf industry accepted components, meet the requirements of NFPA 750 and NFPA 20. Working Pressures for MCC-1, MCC-2 and MCC-3 Maximum system pressure: 250 psi (17,2 bar) Maximum working pressure: Up to 240 psi (16,5 bar) Working Pressures for MCC-A, MCC-B and MCC-C Maximum system pressure: 175 psi (12,1 bar) Maximum working pressure: Up to 170 psi (11,7 bar) Page 1 of 8 JANUARY 2016 TFP2270

Page 2 of 8 SYSTEM DISCHARGE CONNECTION PUMP MOTOR CONTROLLER OPTIONAL SYSTEM CONTROL PANEL AIR TANK LOCATION VALVE CABINET (DOOR NOT SHOWN) AUTOMATIC SYSTEM CONTROL VALVE AIR COMPRESSOR LOCATION SYSTEM (MANUAL) SHUT-OFF CONTROL VALVE AIR TANK AND AIR COMPRESSOR NOT INCLUDED IN ALL MODELS MOTOR PUMP AND TRIM WITH PRESSURE RELIEF VALVES FIGURE 1 AQUAMIST MIST CONTROL CENTER PUMP SKID UNIT TYPICAL CONFIGURATION ASSEMBLY WATER SUPPLY CONNECTION System Components Center (MCC) Pump Skid Unit is available in numerous configurations suitable for different applications, including Wet Pipe, Preaction, Single Zone Deluge, and Multiple Zone Deluge. A typical Pump Skid Unit configuration is illustrated in Figure 1 and includes the following: Gear Pump and Electric Motor Driver Refer to Table B Fire Pump Controller Tornatech Model GPA or GPA+GPU Control Panel (Optional) Potter PFC-4410-RC Pressure Relief Valve TYCO RV-1 Data Sheet TFP1585) System (Manual) Shut-off Control Valve GRINNELL BFV-N Data Sheet TFP1510) Thermal Relief Valve Therm-Omega-Tech 154-010100-100 Optional additional components depend upon the configuration ordered, including: Optional Wet Pipe Components Alarm Valve TYCO AV-1 Data Sheet TFP910) Pressure Control Switch Potter PCS-300-1B Water Flow Switch Potter PS-100 Standby Pressure Pump Albany CEP93 Available with 50 Hz and 60 Hz motor

Page 3 of 8 Optional Deluge System Components Deluge Valve Data Sheet TFP1305) Water Flow Switch Potter PS10-2A data sheet.) Electric Actuation Trim Data Sheet TFP1320) Optional Preaction System Components Deluge Valve Data Sheet TFP1305.) Riser Check Valve TYCO CV-1FR Data Sheet TFP950) Single Interlock Preaction System Data Sheet TFP1420) Double Interlock Preaction System Data Sheet TFP1465) The MCC has been designed to readily incorporate 1-1/2 through 3 inch (DN40 through DN80) valve risers. The valve riser and all associated trim is located inside of the Red-E Cabinet. For on-board valve and trim configurations, which are typical for single zone systems, all components are provided pre-assembled, preplumbed, and pre-wired. In this case, the riser and Red-E Cabinet are mounted directly to the pump assembly. For off-board valve and trim configurations, which are typical for multiple zones, or when it is desirable to install the fire protection control valve and the pump in different locations, the pump unit with controller and associated devices is provided as a pre-assembled unit, and each fire protection control valve, trim, and related devices will be provided in one or more stand-alone Red-E Cabinets. Model MCC-1 MCC-2 MCC-3 MCC-A MCC-B MCC-C FM Approved Application HC-1 Data Processing Equipment Rooms/Halls Machinery Spaces & Combustion Turbine Enclosures Industrial Fryer Protection (IFP) Capacity gpm (lpm) System Pressure psi (bar) Design Considerations The system designer must consider and make preparations for use of the TYCO AQUAMIST Mist Control Center (MCC) Pump Skid Unit as follows (Ref. Figure 2 for Installation Dimensions): adequate floor space for installation and maintenance of the unit adequate clearance for opening of pump controller, valve cabinet, and alarm panel doors adequate clearance to maneuver the MCC Pump Skid Unit through hallways and doors as necessary to place the system in its installation location. minimum ambient temperature of 40 F (4 C) TFPP Technical Data Sheet Number Frequency (Hz) TFP2230 TFP2233 TFP2234 TFP2240 TABLE A AQUAMIST MIST CONTROL CENTER PUMP SKID UNIT FM APPROVED APPLICATIONS Pump Model Motor Power hp (kw) 57 (216) 250 (17,2) 50 160-332 HD 25 (19) 56 (212) 250 (17,2) 60 80-440 HD 20 (15) 110 (416) 250 (17,2) 50 300-372 HD 40 (30) 106 (401) 250 (17,2) 60 160-338 HD 40 (30) 166 (628) 250 (17,2) 50 300-368 HD 60 (45) 165 (624) 250 (17,2) 60 330-388 HD 50 (37) 57 (216) 175 (12,1) 50 160-332 HD 25 (19) 56 (212) 175 (12,1) 60 80-440 HD 20 (15) 110 (416) 175 (12,1) 50 300-372 HD 40 (30) 106 (401) 175 (12,1) 60 160-338 HD 40 (30) 166 (628) 175 (12,1) 50 300-368 HD 60 (45) 165 (624) 175 (12,1) 60 330-388 HD 50 (37) TABLE B GEAR PUMP AND ELECTRIC MOTOR DRIVER SELECTION installation of a suitably sized water supply to the water supply header installation of system piping from valve cabinet outlet(s) installation of system piping between pump unit and valve cabinet(s), if necessary installation of drains from main drain header and drip funnel headers installation of pump test header power supply to pump controller power supply to releasing panel power supply to excess pressure pump (Wet Valve models only) installation of detection system components (when required) power supply to air compressor (Preaction models only)

Page 4 of 8 A B Nominal Dimensions Inches (mm) A B MCC-1 & MCC-A 40 (1016,0) 10 (254,0) MCC-2 & MCC-B 52 (1320,8) 15 (381,0) MCC-3 & MCC-C 52 (1320,8) 15 (381,0) FOUNDATION PLAN 10.50" (266,7 mm) 0.75" DIA. (19,1 mm) C 28 (711,2) 30 (762,0) 34 (863,6) D 14 (355,6) 14.75 (374,7) 17 (431,8) E 10.25 (260,4) 13 (330,2) 13 (330,2) C D 66" (1676,4 mm) 77.25" (1962,2 mm) E FIGURE 2 AQUAMIST MIST CONTROL CENTER PUMP SKID UNIT INSTALLATION DIMENSIONS

Page 5 of 8 Installation Center (MCC) Pump Skid Unit must be installed in accordance with this section. Placing and Positioning The MCC should be located with adequate space to ensure access to all serviceable components. Adequate floor space to facilitate opening of the pump controller, valve cabinet, and alarm panel doors should be maintained. The pump unit must be securely mounted or otherwise fastened on a smooth, level, hard surface capable of supporting the full weight of the unit in such a way that pump and motor shaft alignment will be maintained. The pump and motor must be mounted on a common grouted baseplate. The mounting foundation absorbs vibrations, strains, or shock, while providing a permanent, rigid support for the pump skid. System Piping Connection Piping connections to the MCC must be made in accordance with NFPA 20 and NFPA 750, or other installation code acceptable to the authority having jurisdiction. The MCC requires four piping connections: water supply; system connection; main drain; and funnel drain(s). The inlet piping should be equal to, or one size larger than, the pump inlet port connection. The pump should not be operated under static lift conditions without consulting the pump manufacturer. Do not install 45-degree or 90-degree fittings at the pump suction port. When possible, provide at least 20 pipe diameters of straight pipe at the suction port. A pump inlet strainer, as required by NFPA 20, must be equipped with a removable and cleanable suction strainer, and installed at least 10 pipe diameters from the pump suction inlet. (For strainer mesh size selection, refer to specific data sheets of pumps listed in Table A for manufacturer s recommendations.) The net open area of the strainer must be at least 4 times the area of the suction piping. The suction strainer should be located in the horizontal position with the cleanout plug toward the floor. The strainer may, however, be oriented in the vertical position provided that the cleanout plug is facing toward the floor. The pump should not be operated without the strainer in place as foreign material may be large enough to damage the pump. To avoid pump cavitation, the Net Positive Suction Head (NPSH) supplied should exceed the pump manufacturer s required NPSH plus 5 feet of liquid. (Refer to Technical Data Sheets of pumps listed in Table B.) Downstream (on the system side) of the AQUAMIST MCC Pump Skid Unit, a filter or strainer is required at the supply side of each nozzle and at the point of transition to corrosion resistant pipe per NFPA 750. Strainers are ordered separately from the AQUA- MIST MCC Pump Skid Unit. For selection and ordering of inlet and discharge strainers tested and approved for use with the AQUAMIST MCC Pump Skid Unit, refer to the Ordering Procedure section and Table D. A supervised shutoff valve (not included) should be between the water source and the pump inlet to facilitate servicing of the pump unit. Electrical Requirements The standard MCC is delivered preconfigured for 460 volt, 60 Hz 3 phase power. Other voltages and frequencies are available as special order items. Electrical power supplies should be in accordance with National Electric Code (NFPA 70), NFPA 20, and/or equivalent local electrical codes. Power supply conductors must be sized according to the National Electric Code (NFPA 70), or equivalent local electrical code, on a continuous duty basis. The incoming conductors should have a 140 F (60 C) or 167 F (75 C) current rating of not less than 125% of the motor full load current carrying capacity. Conduit entrance can be made only through the bottom gland plate of the controller. Use appropriate waterproof conduit hubs to keep water out of the controller. The pump unit can be special ordered with a wide range of electrical configurations, including alternate voltages and frequencies. For additional details, please contact the Technical Services department. For additional installation instructions, please see the installation, operation, and maintenance manual, AQUAMIST Mist Control Center (MCC) Pump Skid Unit Installer s Manual, (Doc MCCAU001), provided with the AQUA- MIST MCC Pump Skid Unit. In addition to the preceding requirements, it provides information for the following installation steps: placing and positioning of the MCC unit connecting the system piping connecting the electrical circuits programming the control panel setting the automatic control valve setting the pump supply pressure testing and commissioning the system Care and Maintenance Center (MCC) Pump Skid Unit must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must first be obtained from the proper authorities and all personnel who may be affected by this decision must be notified. Inspection, testing, and maintenance must be performed in accordance with the requirements of NFPA 25 and any impairment must be immediately corrected. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of any authorities having jurisdiction. The riser components enclosed within the MCC, however, must be maintained in accordance with their applicable technical data sheets referenced in the System Components section. Contact the installing contractor or product manufacturer with any questions.

Page 6 of 8 10.00 8.00 FLOW RATE IN LITRES PER MINUTE (LPM) (1 GPM = 3,785 LPM) 80 100 200 300 400 600 800 1000 0,600 6.00 0,400 NOMINAL PRESSURE DROP IN POUNDS PER SQUARE INCH (PSI) 4.00 3.00 2.00 1.00 0.80 0.60 1 INCH (DN25) 1-1/4 INCH (DN32) 1-1/2 INCH (DN40) 2 INCH (DN50) AND 2-1/2 INCH (DN65) 3 INCH (DN80) 0,200 0,100 0,080 0,060 0,040 NOMINAL PRESSURE DROP IN BAR (1 PSI = 0,06895 BAR) 0.40 0.30 0,020 0.20 0,010 0.10 20 40 60 80 100 200 300 FLOW RATE IN GALLONS PER MINUTE (GPM) GRAPH A BRONZE SYSTEM STRAINERS NOMINAL PRESSURE LOSS VS. FLOW 0,008

Page 7 of 8 10.00 8.00 6.00 FLOW RATE IN LITRES PER MINUTE (LPM) (1 GPM = 3,785 LPM) 40 60 100 200 300 400 600 1000 0,600 0,400 4.00 3.00 0,200 NOMINAL PRESSURE DROP IN POUNDS PER SQUARE INCH (PSI) 2.00 1.00 0.80 0.60 0.40 1-1/2 INCH (DN40) 2 INCH (DN50) 2-1/2 INCH (DN65) 0,100 0,080 0,060 0,040 NOMINAL PRESSURE DROP IN BAR (1 PSI = 0,06895 BAR) 0.30 0,020 0.20 0,010 0,008 0.10 10 20 40 60 80 100 200 300 FLOW RATE IN GALLONS PER MINUTE (GPM) GRAPH B STAINLESS STEEL SYSTEM STRAINERS NOMINAL PRESSURE LOSS VS. FLOW

Page 8 of 8 P/N MCC-XXXXXX Model 1 MCC-1 2 MCC-2 3 MCC-3 A B C MCC-A MCC-B MCC-C Backup Power 0 No Transfer Switch 1 With Transfer Switch Freq. Electrical Voltage 1 50 380 2 50 415 3 60 208 4 60 230 5 60 460 6 60 575 Valve & Trim Location 1 On-board 2 Off-board Actuation 1 Deluge Electric 2 Wet Pipe Release Panel 0 No Panel 1 PFC-4410 RC 3 Double Interlock Electric-Electric Preaction* 4 Single Interlock Preaction 5 Double Interlock Preaction Pneumatic-Electric* * Non-FM Approved Configuration TABLE C AQUAMIST MIST CONTROL CENTER (MCC) PUMP SKID UNIT PART NUMBER SELECTION Model Size Inches (mm) Connection Material TYCO P/N Watts Mueller 781-SS 0.75 (19) Flange 316SS 3/4" 781-SS Watts Mueller 781-SS 2 (51) Flange 316SS 2" 781-SS Watts Mueller 781-SS 2.5 (64) Flange 316SS 2-1/2" 781-SS SSI-250Y1 1 (25) NPT Bronze 0100-250Y1TB-A2 SSI-250Y1 1.25 (32) NPT Bronze 0125-250Y1TB-A2 SSI-250Y1 1.5 (38) NPT Bronze 0150-250Y1TB-A2 SSI-250Y1 2 (51) NPT Bronze 0200-250Y1TB-A2 SSI-250Y1 2.5 (64) NPT Bronze 0250-250Y1TB-A2 SSI-250Y1 3 (76) NPT Bronze 0300-250Y1TB-A2 TABLE D INLET AND DISCHARGE STRAINER PART NUMBER SELECTION Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product name and part number (P/N). AQUAMIST Mist Control Center (MCC) Pump Skid Unit Specify: AQUAMIST Mist Control Center (MCC) Pump Skid Unit, P/N (specify from Table C) Note: All double-interlock preaction actuation configurations are not FM Approved configurations. Inlet and Discharge Strainer Specify: Strainer, P/N (specify from Table D) GLOBAL HEADQUARTERS 1400 Pennbrook Parkway, Lansdale, PA 19446 Telephone +1-215-362-0700 Copyright 2016 Tyco Fire Products, LP. All rights reserved.