MODEL ACCELEROMETER

Similar documents
DOG2 MEMS SERIES USB INCLINOMETER

OPERATION MANUAL MODEL 805M1 ACCELEROMETER

MODEL 834M1 ACCELEROMETER

The MiCS-5524 is a compact MOS sensor.

Datasheet CozIR -A CO2 Sensor

SprintIR -6S CO2 Sensor

The MiCS-6814 is a compact MOS sensor with three fully independent sensing elements on one package.

MODEL 4000A & 4001A ACCELEROMETER

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

The MiCS-6814 is a compact MOS sensor with three fully independent sensing elements on one package.

OPERATION MANUAL MODEL & ACCELEROMETER

OPERATION MANUAL Model 8011 & mA

OPERATION MANUAL MODEL 4610 ACCELEROMETER

OPERATION MANUAL MODEL 805 ACCELEROMETER

OPERATION MANUAL MODEL 8102 ACCELEROMETER

DP86 Constant Voltage with Fitting

Standard SPECIFICATIONS FEATURES APPLICATIONS

MS1471 SPECIFICATIONS. PC Board Mountable Pressure Sensor 0-60 mv Output Gage and Absolute Low Cost

PT9150 (Extended Range)

PT9420 (Extended Range)

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

ED-18 Analog Output Series Magnetic Encoder SPECIFICATIONS

OPERATION MANUAL MODEL 3255A ACCELEROMETER

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

Sub psi SPECIFICATIONS

PT9600. Cable Actuated Encoder Reel. General. Environmental

OPERATION MANUAL MODEL 3038 ACCELEROMETER

Cable Actuated Sensor Industrial Incremental Encoder Output

D5100 Industrial Differential Pressure Transducer

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

ELAF LOAD CELL SPECIFICATIONS FEATURES

15203B 25203B 35203B Uniaxial Biaxia Triaxial

Cable Actuated Sensor Industrial User Scalable 4 20mA

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

P125 High Pressure Sensor

M7100 Pressure Transducer

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

Cable Actuated Sensor Industrial User Scalable VDC Output

D5100 Industrial Differential Pressure Transducer

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

MSP100 Pressure Transducer

LOW PRESSURE Intrinsically Safe Transducer AST44LP

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

86BSD Digital Output

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

MSP100 Pressure Transducer

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

M5800 Pressure Transducer with Rotatable Display

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

FC22 Compression Load Cell

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

TS105-10L5.5MM Thermopile Sensor

HM1520LF Relative Humidity Module

OPERATION MANUAL MODEL mA

MSP340 Pressure Transducer

86BSD Digital Output

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

SPECIFICATIONS. SENSOR SOLUTIONS ///LM Page 1 09/2015

M5800 Pressure Transducer with Rotatable Display

86A SPECIFICATIONS. 316L SS Pressure Sensor Small Profile V High Level Output Gage, Absolute ASIC Calibrated

HM1500LF Relative Humidity Module

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

M5200 Industrial Pressure Transducer

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

86BSD Digital Output

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

LMM-H03 Mass Air FLow Sensor

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID

NTC THERMISTOR SENSOR PERFORMANCE

LMM-H04 Mass Air FLow Sensor

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

DOG2 MEMS SERIES CAN J1939 INCLINOMETER

MS4525 SPECIFICATIONS

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR IOS

FC23 Compression Load Cell

MSP300 Pressure Transducer

MEAS PICTAIL PLUS FOR MICROCHIP EXPLORER 16

U5700 Submersible Liquid Level Pressure Transducer

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

The Importance of Pressure Sensors in HVACR Systems

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

U5300 Industrial Pressure Transducer

TSEV01S01C10 SPECIFICATIONS

DSS SERIES. Single Channel Hall Effect Speed Sensor. Product ID

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

WP4086 Condition Monitoring System

MEAS EMITTER ASSEMBLY ELM-4000 SERIES

TESS WIRELESS SENSOR TAG DEMO V1.1

89BSD Digital Output

TESS WIRELESS SENSOR TAG DEMO V1.1

CABLES AND ACCESSORIES FOR TRUBLUE DATA LOGGERS

TSYS02S Digital Temperature Sensor

DTS SERIES CONNECTORS

TE Connectivity's AMP NETCONNECT Cable Management

Transcription:

MODEL 8711-01 ACCELEROMETER SPECIFICATIONS Industrial IEPE Accelerometer Low Cost, Quick Delivery -55 C to +125 C Operating Range Top Exit Connector DIMENSIONS The Model 8711-01 are internally shielded rugged IEPE accelerometers designed for industrial condition monitoring. The accelerometers are available in ±5g to ±80g dynamic ranges and have a flat bandwidth up to greater than 10kHz. The model 8711-01 accelerometer features a top exit MIL-C-5015 connector and is designed to operate in temperature ranges from -55 C to +125 C. FEATURES ±5g, ±10g, ±20g & ±80g Dynamic Ranges Wide bandwidth up to >10kHz Case Isolated, Internally Shielded Hermetically Sealed, Welded Annular Shear Mode Reverse Wiring Protection Stable Temperature Response APPLICATIONS General Purpose Machine Monitoring Industrial Applications Harsh Environments Gearbox Monitoring SENSOR SOLUTIONS /// Model 8711-01 Rev A 9/2015 Page 1

PERFORMANCE SPECIFICATIONS All values are typical at +24 C, 80Hz and 4mA excitation unless otherwise stated. Measurement Specialties reserves the right to update and change these specifications without notice. Standard product parameters are described in PSC-1003 for Plug & Play AC Accelerometers. Parameters DYNAMIC Notes Range (g) ±5 ±10 ±20 ±80 Sensitivity (mv/g) 1000 500 250 100 ±10% Frequency Response (Hz) 0.3-4000 0.3-4000 1-7000 1-7000 ±5% Frequency Response (Hz) 0.1-6000 0.1-6000 0.3-10000 0.3-10000 ±3dB Natural Frequency (Hz) 20000 20000 32000 32000 Non-Linearity (%FSO) ±1 ±1 ±1 ±1 Transverse Sensitivity (%) <5 <5 <5 <5 Shock Limit (g) 2000 2000 5000 5000 Residual Noise (g RMS) 0.00003 0.00005 0.00010 0.00015 Weight (grams) 105 105 88 88 ELECTRICAL Compliance Voltage (Vdc) 18 to 30 See Note 1 Excitation Current (ma) 2 to 10 Bias Voltage (Vdc) 10 to 13 Room Temperature Output Impedance (Ω) <100 Insulation Resistance (MΩ) >100 @100Vdc Warm-up Time (sec) <5 Grounding Case Isolated, Internally Shielded ENVIRONMENTAL Temperature Response (%) See typical temperature response on following page Operating Temperature ( C) -55 to +125 Storage Temperature ( C) -55 to +125 Humidity Hermetically Sealed, IP67 PHYSICAL Sensing Element Case Material Mounting Torque Ceramic (shear mode) Stainless Steel 24 lb-in (2.7 N-m) 1 For full dynamic range a minimum compliance voltage of 24Vdc is recommended Calibration supplied: CS-SENS-0100 NIST Traceable Amplitude Calibration at 80Hz Supplied accessories: AC-A03663 ¼-28 to ¼-28 mounting stud Optional accessories: 316A-XXX Cable Assembly, Straight (XXX designates length in inches, 10ft standard) 318A-XXX Cable Assembly, 90 Degrees (XXX designates length in inches, 10ft standard) AC-D03664 ¼-28 to M5 mounting stud AC-D03665 ¼-28 to M6 mounting stud The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. SENSOR SOLUTIONS /// Model 8711-01 Rev A 9/2015 Page 2

Sensitivity Deviation (%) Typical Frequency Response 40 35 30 25 20 15 10 5 0-5 -10-15 -20-25 -30 Standard Option -35 LF Option -40 0 1 10 100 1000 10000 100000 Frequency (Hz) SENSOR SOLUTIONS /// Model 8711-01 Rev A 9/2015 Page 3

ORDERING INFORMATION PART NUMBERING Model Number+Range 8711LF-01-GGG l l Range (080 is 80g) l Low frequency, required for 5g and 10g ranges Standard model numbers: 8711LF-01-005 8711LF-01-010 8711-01-020 8711-01-080 TE.com/sensorsolutions Measurement Specialties, Inc., a TE Connectivity company. Measurement Specialties, TE Connectivity, TE Connectivity (logo) and EVERY CONNECTION COUNTS are trademarks. All other logos, products and/or company names referred to herein might be trademarks of their respective owners. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, TE Connectivity makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. TE Connectivity s obligations shall only be as set forth in TE Connectivity s Standard Terms and Conditions of Sale for this product and in no case will TE Connectivity be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of TE Connectivity products should make their own evaluation to determine the suitability of each such product for the specific application. 2015 TE Connectivity Ltd. family of companies All Rights Reserved. SENSOR SOLUTIONS /// Model 8711-01 Rev A 9/2015 Page 4

Headquarter Switzerland: Pewatron AG Thurgauerstrasse 66 CH-8050 Zurich Phone +41 44 877 35 00 info@pewatron.com Office Germany: Pewatron Deutschland GmbH Edisonstraße 16 D-85716 Unterschleißheim Phone +49 89 374 288 87-0 info.de@pewatron.com We are here for you. Addresses and Contacts. Sales Germany & Austria Postcode 00000 31999 Postcode 38000 39999 Postcode 80000 99999 Austria Kurt Stritzelberger Phone + 49 89 260 52 80 Mobile + 49 171 803 41 35 kurt.stritzelberger@pewatron.com Postcode 32000 37999 Postcode 40000 79999 Gerhard Vetter Phone + 49 674 394 75 75 Mobile + 49 163 762 74 30 gerhard.vetter@pewatron.com Geometrical sensors Sensor elements Thorsten Ravagni Phone +49 60 479 53 627 thorsten.ravagni@pewatron.com Sales Switzerland & Liechtenstein Postcode 3000 9999 Basil Frei Phone + 41 44 877 35 18 Mobile + 41 76 279 37 26 basil.frei@pewatron.com Postcode 1000 2999 Christian Mohrenstecher Mobile +41 76 444 57 93 christian.mohrenstecher@pewatron.com Sales International Key Accounts Peter Felder Phone + 41 44 877 35 05 Mobile + 41 79 406 49 83 peter.felder@pewatron.com Sales Other Countries / Product Management Pressure Sensors Philipp Kistler Phone + 41 44 877 35 03 philipp.kistler@pewatron.com Gas sensors / Gas sensor modules Load cells Dr. Thomas Clausen Phone + 41 44 877 35 13 thomas.clausen@pewatron.com Flow / Level / Medical products Dr. Adriano Pittarelli Phone +49 8245 774 95 44 adriano.pittarelli@pewatron.com Accelerometers / Level Flow sensor elements Thorsten Ravagni Phone +49 60 479 53 627 thorsten.ravagni@pewatron.com Power supplies Sebastiano Leggio Phone + 41 44 877 35 06 sebastiano.leggio@pewatron.com Linear position sensors Angle sensors Eric Letsch Phone + 41 44 877 35 14 eric.letsch@pewatron.com Drive technology CH Postcode 5000 9999 / DE Roman Homa Mobile + 41 76 444 00 86 roman.homa@pewatron.com Drive technology CH Postcode 1000 4999 / AT / IT / FR Christian Mohrenstecher Mobile +41 76 444 57 93 christian.mohrenstecher@pewatron.com Current sensors Power solutions Osman Coban Phone +49 71 635 363 898 osman.coban@pewatron.com Sensors Power Solutions - Experts on Design-In