ADDENDUM NO:2 AGAINST TENDER FOR DESIGN, ENGINEERING, SUPPLY, INSTALLATION, TESTING, COMMISSIONING AND POST WARRANTY AMC OF RIM SEAL FIRE PROTECTION SYSTEM FOR BPCL- MUMBAI REFINERY (BPCL MR) TENDER CRFQ NO. 1000198686 (E-TENDER REF NO.13020)
ADDENDUM NO:2 AGAINST TENDER CRFQ NO. 1000198686 (E-TENDER REF NO.13020) DESIGN, ENGINEERING, SUPPLY, INSTALLATION, TESTING, COMMISSIONING AND POST WARRANTY AMC OF RIM SEAL FIRE PROTECTION SYSTEM FOR BPCL-MUMBAI REFINERY (BPCL MR) Sl No TENDER ANNEXURE/ CLAUSE AND SUBCLAUSE TENDER CLAUSE DESCRIPTION DESCRIPTION OF ADDENDUM ANNEXURE-A-SPECIFICATIONS CLAUSE 5. LINEAR HEAT DETECTION (LHD) SYSTEM. SUB- 1 CLAUSE 5.1 PRINCIPLE OF OPERATION The Detection system shall be site configurable for rate of rise and maximum The system shall be able to sense the rapid rate of rise or preset maximum temperature or both to ensure that any incipient fire on rim seal is detected within 10 seconds of occurrence. temperature at two different alarm thresholds at Graphic console & rim seal main fire alarm panel. The logic should be such that alarm should come for initiating actuation if there is rate of rise and also when max. temperature is reached. This will ensure that even if one fails other will work. ANNEXURE-A-SPECIFICATIONS CLAUSE 5.2 :LHD Mounting 2 The sensor tube shall be located on the external face of the weather shield so that it can be inspected without the need for removal of any seal components. The sensor tube shall be located above primary seal and below weather shield plate. ANNEXURE-A-SPECIFICATIONS CLAUSE 5. LINEAR HEAT 3 DETECTION (LHD) SYSTEM AND SUB-CLAUSE 5.3 The linear heat detection system shall provide fire alarm / fault signals separately for each tank at the rim seal main fire alarm panel at Fire station Control Room / LCP/PH1/PH5/ARU control rooms. Provision of signals at both locations i.e Fire station control room and LCP/PH1 ANNEXURE-A-SPECIFICATIONS CLAUSE 12 ELECTRICAL & 4 INSTRUMENTATION SYSTEM. SUB CLAUSE (c) Cables laid above ground shall be in GI Cable trays or suitable size To add: New cable tray to be provided as per approved drawing. ANNEXURE-A SPECIFICATIONS CLAUSE13.0 5 INSTRUMENTATION SPECIFICATIONS. SUB CLAUSE 13.7 All tubes shall be of SS 316 L and its OD shall be in mm. All tubes fittings shall be of SS- 316, double compression, suitable for tubes in mm OD. All the coupling To add: Only vendors like M/s Parker & Swagelock shall be considered. / connections shall be swage lock or approved equivalent. SPECIFICATIONS CLAUSE. -14.2- FACTORY ACCEPTANCE 6 TEST SPECIFICATIONS CLAUSE 17.0 7 DOCUMENTATION:Documents to be furnished with offer/bid:(4 copies).sub Clause (f) ANNEXURE-A-SPECIFICATIONS CLAUSE 21.BIDDER S 8 SCOPE OF SUPPLY/WORK AND SUB-CLAUSE (f) One such test shall be performed for every 50 % units ordered in random manner as decided by the owner. Bill of Material indicative for 8m,9.14m,12m, 30m, 34m,36m, 44m, 49.2m, 53m & 79m dia tank To arrange / carryout Factory acceptance test for various sub-systems of the tender specifications FAT shall be conducted for one Tank (as decided by BPCL) with two system modules. Tentative Bill of materials shall be provided as per tank list provided in tender. Material for one tank (as decided by BPCL), with two set of system modules, should be kept at vendors works for FAT. After the FAT, the above material shall be despatched to BPCL ANNEXURE-A-SPECIFICATIONS CLAUSE 21.0 Bidder s Scope 9 of Supply/work:Sub Clause o) Provision of Uninterrupted power supply at the Rim seal main Fire Alarm panel at Fire station control room for uninterrupted operation of entire rim seal fire protection system.ups shall be single phase parallel redundant,with bypass transformer,static voltage stabilizer and battery bank(plante type) with 2 hours backup UPS shall be provided with 2 sets of rectifiers and inverters. 230 Volts UPS Power(Single point) shall be made available at P/H1 and P/H ANNEXURE-A. SPECIFICATIONS CLAUSE 21.0 Bidder s Scope 10 5.Bidder shall supply and install 230 Volts power distribution board at P/H1 and of Supply/work:Sub Clause p) P/H 5 for further distribution. UPS and distribution board not required. Output of UPS is 230V AC.Bidder shall ensure that all the equpment shall be suitable for 230V AC power supply. ANNEXURE-A SPECIFICATIONS CLAUSE 21.0 Bidder s Scope 11 of Supply/work:Sub Clause t) Suitable Water supply arrangement for re-filling each foam modules mounted over tank roofs shall be made. G.I. Piping is required to be laid from tank roof top Additional Information: GI piping not required; high pressure flexible hose of sufficient to the nearest fire water hydrant line along the road outside the dyke area & length to be provided with suitable end fittings standard 63 mm instantaneous male hose coupling shall be fitted at the end for connectivity wit nearest fire hydrant. 1
ADDENDUM NO:2 AGAINST TENDER CRFQ NO. 1000198686 (E-TENDER REF NO.13020) DESIGN, ENGINEERING, SUPPLY, INSTALLATION, TESTING, COMMISSIONING AND POST WARRANTY AMC OF RIM SEAL FIRE PROTECTION SYSTEM FOR BPCL-MUMBAI REFINERY (BPCL MR) Sl No TENDER ANNEXURE/ CLAUSE AND SUBCLAUSE TENDER CLAUSE DESCRIPTION DESCRIPTION OF ADDENDUM 12 SPECIFICATIONS CLAUSE 8.4 Graphic Console (HMI) One Graphic Console of adequate capacity (LG/Samsung/Sony/Panasonic make 21 inch LCD) with software shall be provided in the control room to monitor Rim seal Fire protection system installed on all the tanks. SPECIFICATIONS CLAUSE 21.Bidder s Scope of 13 Supply/work:SUB CLAUSE (q) Supply & Installation of One Graphic Console of adequate hardware (LG/Samsung/Sony/Panasonic make 21 inch size LCD) with software for graphical representation of unique site based layout of tank farm indicating tanks being protected by rim seal fire protection system, LCP s & Repeater station. The software shall have features of tank number with active pop-up, event logging, history and prints. Additional Information: New Graphic Console has to be supplied or the system should be hooked up with existing Graphic Console. SPECIFICATIONS, ANNEXURE IV, TECHNICAL 14 SPECIFICATION FOR VARIOUS INSTRUMENTS, SUB CLAUSE 6. Graphic Console (1 &16) Graphic Console : Make:DELL / HP / IBM Monitor:21.5" Full HD Wide screen Flat panel with provision to accept input from two work stations with toggle button to select the work station. SPECIFICATIONS ANNEXURE-IV TECHNICAL 15 SPECIFICATIONS FOR VARIOUS INSTRUMENTS, SUB CLAUSE-3 Pressure switch as per tender specs. Element type: Bellows Connection size & Type: 1/2: NPT(F) Element of Pressure Switch (Type: Diaphragm) is acceptable.pressure switch shall have pneumatic connection of ¼ NPT(F). ANNEXURE-A-SPECIFICATIONS -ANNEXURE-VI. SL NO. 7 16 SOLENOID OPERATED VALVE ASCO / HERION To add: ROTEX make SOV is also acceptable ANNEXURE-A-SPECIFICATIONS -ANNEXURE-VI. SL NO. 8 GI 17 CABLE TRAYS PATNY & CO / TECHNOFAB / INDIANA / SADHANA/ IDS Composites/ National Galvaniser /Vatco /Steelite/Ratan Engineering To add: The following sub vendors are also acceptable; M.M Engg/Silverline/Superelectro ANNEXURE-A-SPECIFICATIONS -ANNEXURE-VI. SL NO. 19 To add: The following sub vendors are also acceptable; 18 24 V BULK POWER SUPPLY UNIT Lamda, Cosel, Phoenix, Siemens, Quint Omron/Turk Technical specification Part II-Instruction to bidder on Vendor shall provide the Instrumentation System Design Philosophy for the 19 Specification for RIM Seal system for Floating roof tanks.phase IIentire 19 nos. tanks RIM seal system Clause No:11. Vendor shall provide the Instrumentation System Design Philosophy for the entire 9nos. tanks RIM seal system. 20 OFC cables OFC cables can be used, however check the communication protocol for this. 21 FIRE SUPPRESSION SYSTEM - FOAM DISCHARGE PIPING Flanged joint with metallic gaskets acceptable. 22 ANNEXURE-B SCC. CLAUSE 16. PROGRESS REPORTS Progress report shall be submitted on a weekly basis, covering overall scenario of the work Progress report shall be submitted on fort-nightly basis 2
ADDENDUM NO:2 AGAINST TENDER CRFQ NO. 1000198686 (E-TENDER REF NO.13020) DESIGN, ENGINEERING, SUPPLY, INSTALLATION, TESTING, COMMISSIONING AND POST WARRANTY AMC OF RIM SEAL FIRE PROTECTION SYSTEM FOR BPCL-MUMBAI REFINERY (BPCL MR) Sl No TENDER ANNEXURE/ CLAUSE AND SUBCLAUSE TENDER CLAUSE DESCRIPTION DESCRIPTION OF ADDENDUM ANNEXURE-B, SCC, CLAUSE NO NO. 27- EVALUATION 23 CRITERIA Priced Bids shall be evaluated on overall landed cost basis including all taxes and duties, TPI charges, freight etc and loading on commercial deviations (if any), less eligible Cenvat/VAT Credit. The evaluation shall be based on the overall lowest quote basis considering the sum of the prices for Part-1 (Supply), Part-II (Site works) and Part-III (Post Warranty Annual Maintenance Charges for 3 years) including all taxes and duties, TPI charges, freight etc and loading on commercial deviations (if any), less eligible Cenvat/VAT Credit. ANNEXURE-B, SCC, CLAUSE NO. 36- STORAGE OF 24 MATERIALS AND CONSTRUCTION OF SITE SHED- SUB CLAUSE 36.1 Contractor has to find a suitable place with prior approval of Engineer-in-charge for the storage of all types of equipments, machineries, materials, consumables, tools & tackles and working place, site shed. To add: Contractor to arrange their own container office/store room, space will be provided within BPCL premises. Power for lighting, water will be provided free of cost. Necessary/wiring/cabling required for it shall be done by the vendor. 25 BID DUE DATE The due date of the tender is extended till 27.12.2013, 11:00 Hrs (IST). In view of this, the following in the tender undergoes change; COVER PAGE OF THE TENDER Tender Calendar Details as per Addendum No:1 Stage Name Start Date Tender Release 20.11.2013 Site Visit/ Pre Bid meeting Pre-qualification bid opening Un-priced Bid Opening End Date And Time 20.12.2013 (11:00 Hrs IST) 05.12.2013 Between 1000 Hrs to 1600 Hrs at BPCL Mumbai Refinery 20.12.2013 (11:15 Hrs IST) Will be intimated Priced Bid Opening Will be intimated Will be intimated Will be intimated Stage Name Revised Tender Calendar Details Start Date Tender Release 20.11.2013 Site Visit/ Pre Bid meeting Pre-qualification bid opening Un-priced Bid Opening End Date And Time 27.12.2013 (11:00 Hrs IST) 05.12.2013 Between 1000 Hrs to 1600 Hrs at BPCL Mumbai Refinery 27.12.2013 (11:15 Hrs IST) Will be intimated Priced Bid Opening Will be intimated Will be intimated Will be intimated NOTICE INVITING TENDER Tender due date: 20th December 2013, 11:00 Hrs. IST. (As per Addendum No:1) Revised Tender due date: 27th December 2013, 11:00 Hrs. IST. ALL OTHER TERMS AND CONDITIONS OF THE ORIGINAL TENDER REMAIN UNALTERED. This Addendum shall form the part of tender document and shall be duly signed, stamped and submitted by bidder along with the techno-commercial (unpriced) bid. Date: 20th December 2013 (For) Dy. General Manager (CPO-Refineries) Central Procurement Organisation (Refineries), Mumbai Refinery, Mahul, Mumbai-400 074 3