Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm).

Similar documents
Ø 1000 * 588 mm 50 kg

GBRD. Multi Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection. Ordering Information. Applications. Features & Benefits

GUSN. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GUSA. Central Loose Tube Cables (Distribution) Universal Indoor/ Outdoor A/I-DQ(ZN)BH Standard Rodent Protection. Ordering Information.

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Duct Cable GYTS-144B1.3

Multipurpose Cables (indoor/outdoor), Multipurpose central tube cable (maxibundle) with glass yarn armouring A-DQ(BN)H 4-24

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

GOF Indoor and Outdoor Cables. Documentation VWL Version 1.1 Source Code M

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

GOF Indoor and Outdoor Cables. Documentation VWL Version 2.2 Source Code R

HELKAMA. Optical Fibre Cables

SPECIAL ELECTRICAL AND OPTICAL CABLES

Fibre Optic Cable. Catalogue.

Fiber Optic Distribution Cables (6-144 Fibers)

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

OPTICAL. Micromodule DW About Us. > IEC nd Ed. According to. > EN nd Ed. FTTx

TELECOM SOLUTIONS CABLE CATALOGUE INNOVATIVE FIBRE OPTIC CABLE SOLUTIONS

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

industry solutions: military

Special Provision No. 683S28 December 2017

Specification No.CSC-131/R-1/DH//UH/P&D/ Technical Specifications. for 24 Fiber/48 Fiber Unarmoured. Underground Fibre.

13-SDMS-02 REV. 00 SPECIFICATIONS FOR NON-METALLIC, TIGHT BUFFERED & RETRACTABLE, MICRO FIBER OPTIC CABLE FOR INTERNAL INSTALLATION

DNVGL-CP-0402 Edition February 2016

Fibre optic media options and trends

Fibre Specification Standards

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Catalogue Telecommunication Cables INTRODUCCIÓN

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

High Performance LSZH Fire Resistant Cable

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Flame Retardant Overall Screened Instrumentation Cables (multicore)

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

FIRE RESISTANT CABLES

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Main features of the JETnet system

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Caledonian Flame Retardant Coaxial Cables

Catalogue Power Cables

Tratos Railway Cables

ENHANCED FIRE PERFORMANCE CABLE

Detection of Solvents using a Distributed Fibre Optic Sensor

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Telecommunication Cables

Installation Considerations for Pipelines

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Lloyd s Register Type Approval System Test Specification Number 3

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

SECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

fire resistant cables

S Low loss coax cables with foamed PE

Caledonian Fire resistant Coaxial Cables

Firecel Safety Cables

TECHNICAL REPORT IEC TR Optical fibre cables Guidelines to the installation of optical fibre cables. colour inside. Edition 2.

Cable technology for highest safety requirements

CHALLENGE OF THE NEW OPTICAL FIBRE TECHNOLOGIES

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

PRODUCT CATALOGUE Norröna

Introduction.

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

FIRE PERFORMANCE CABLE

CATEGORY 6A FTP RJ45 SOLUTION

Connectors for Optic Fibre Cable

WG Buried Fibre Cable Long Perimeter Detection System

Specification Document. Heat-resisting Type Water Leakage Sensor FR-AD

Comtran Cable. Hub-LINK Cables for Transit Applications

The Quality Connection. BETAflam Fire Resistant Safety Cables

Multi-Core Fire Resistant Cable

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Fiber Optic Patch Cord and Pigtails

Single core cables with reduced wall thickness

Catalogue. Instrumentation & Control Cables

(Notices) EUROPEAN COMMISSION

DNVGL-CP-0401 Edition February 2016

THE TRUE FIRE SURVIVAL CABLE

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Test report for a Teldor Cables SLA-6-01X08- ZAHRH-DD Fibre Optic cable to IEC :1999

The Quality Connection. BETAflam Safety cables for highest demands

Fibre (TIA) Field Test Specification

Technical Publication

ITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

Photovoltaic Cables EN H1Z2Z2-K

Transcription:

GCDG Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection Ordering Information Belden European Part Numbers Fibre type / count 4 6 8 12 18 24 30 36 62.5/125-OM1 GCDG104 GCDG106 GCDG108 GCDG112 GCDG118 GCDG124 GCDG130 GCDG136 -OM2 BW /1200 GCDG204 GCDG206 GCDG208 GCDG212 GCDG218 GCDG224 GCDG230 GCDG236 -OM3 GCDG304 GCDG306 GCDG308 GCDG312 GCDG318 GCDG324 GCDG330 GCDG336 -OM2e GCDG404 GCDG406 GCDG408 GCDG412 GCDG418 GCDG424 GCDG430 GCDG436 -OM2 BW 500/500 GCDG504 GCDG506 GCDG508 GCDG512 GCDG518 GCDG524 GCDG530 GCDG536 -OM4 GCDG604 GCDG606 GCDG608 GCDG612 GCDG618 GCDG624 GCDG630 GCDG636 9/125 ITU G.655 GCDG704 GCDG706 GCDG708 GCDG712 GCDG718 GCDG724 GCDG730 GCDG736 9/125 ITU G.652D-OS2 GCDG804 GCDG806 GCDG808 GCDG812 GCDG818 GCDG824 GCDG830 GCDG836 Std. plywood reel (non-returnable) Std. delivery length Ø 1250 * 688 mm 93 kg 2100 ± 100m Applications For outdoor and indoor use in structured (data) wiring systems such as (campus backbone). For outdoor and indoor use in networks for telecom, cable TV and/or broadcast. Easy to install in ducts, tunnels and trenches by means of compressed air or pulling wire. Suitable for direct burial (crush 400 N/cm). Features & Benefits Installation friendly dry interstices between the loose tubes. Predicted lifetime > 30 years. High mechanical and full rodent protection provided by corrugated steel tape (CST) armor.

Construction & Dimensions Cable Specifications (construction in accordance with IEC 60794) 1. Dielectric central element of glass reinforced plastic (GRP), also as protection against kinks, surrounded by swelling yarns. 2. Jelly filled (non-dripping and silicon-free) loose tubes with primary coated optical fibres (Ø 250 ± 15 µm). Individually colour coded optical fibres: red green blue yellow violet pink. 3. The loose tubes are stranded around the central element, if necessary with fillers (PE-natural), surrounded by swelling tape. Colour coding of the loose tubes: 1. red 2. green rest white. 4. Swellable (for the longitudinal watertightness) aramid yarns as strength members. 5. FRNC/LSNH inner jacket. 6. Corrugated Steel Tape Armoring (CST): longitudinally applied steel tape (0.155 mm). 7. Black UV resistant FRNC/LSNH outer jacket. Identification: BELDEN OFC cable type number x fibre type + date-, meter- and P/N marking. Mechanical Data No. of fibres Max. 36 Cable core 6 tubes Ø Central element (mm) 1.9 Ø Loose tube (mm) 1.9 Ø nom./max. (mm) 13.2 / 13.5 Energy of flame (kj/m) 2800 Weight (kg/km) 195 2

Optical Characteristics Characteristics (cabled) Single-Mode Matched-Cladded optical fibres according to ITU. European Partnumber Coding, Position 5 Fibre-Type Mode- Field /Cladding Diameter (um) Attenuation average/ max. (db/km) Dispersion (ps/(nm-km) PMD (ps/km) Cable Cut-off 8 9/125 G.652D OS2 9.2 ± 0.4 125 ± 0.7 1310 1 0.32 / 0.40 0.21 / 0.30 3.5 18 0.2 1260 7 9/125 G.655 8.4 ± 0.6 1 0.25 / 0.30 3.5 8.5 < 0.1 A 1260 Note A- Link design value Characteristics (cabled) Multi-Mode Graded-Index optical fibres according to IEC 60793 European Partnumber Coding, Position 5 Fibre- Type Mode-Field Diameter (um) Attenuati on average/ max. (db/km) Bandwidt h (MHzkm) Ethernet Performance (m) 1GBE 10 GBE Num. Apert. (µm) Refr. Index 1 62.5/125 OM1 62.5 ± 2.5 2.7 / 3.2 0.6 / 1.1 200 275 33 0.275 ± 1.495 1.490 5 OM2 2.4 / 3.0 0.7 / 1.0 82 1.481 1.476 2 OM2 2.3 / 2.8 0.6 / 0.9 1200 82 1.481 1.476 4 OM2e 50 ± 2,5 2,3 / 2,8 0,6 / 0,9 1200 750 2000 110 na 1,481 1,476 3 OM3 2.5 / 3.0 0.5 / 1.0 1500 900 300 1.482 1.477 6 OM4 2.5 / 3.0 0.5 / 1.0 0 900 1.482 1.477 A test report (attenuation) is supplied with each delivery. 3

Mechanical, Physical and/or Environmental Characteristics Requirements Temperature range according to IEC 60794-1-2-F1 Tansport/storage Installation Operation Pulling tension according to IEC 60794-1-2-E1 Long term Short term -30 to + 70 C -5 to + 50 C -30 to + 70 C 3000 N 4000 N Bending radii for fibres and tubes Installation/operation >25 mm Watertightness (core + inner jacket) according to IEC 60794-1-2-F5 Yes Crush resistance according to IEC 60794-1-2-E3 Armoured Central Loose Tube Cable 50 KN/m Bending radii cable Static according to IEC 60794-1-2-E11 Dynamic according to IEC 60794-1-2-E6 Flame retardancy according to IEC 60332-3-22 (EN 50266-2-2) IEC 61034 (EN 50268) Circuit Integrity according to EN 50200 15 x ø 20 x ø Halogen-free according to IEC 60754-2 (EN 50267-2-2) Corrosivity ph 3.5 - µs/cm 100 Guide to installation and handling When laying and installing optical fibre cables it is vitally important not to exceed the specified values set for pulling tension, bending radii and temperature. The installation methods have to be in accordance with the common standards. To ease insertion into tubes by means of compressed air or pulling wire, certified lubricants (e.g. paraffin) may be used. The use of soap or similar substances as lubricants is strictly prohibited. If a cable needs to be fastened, constrictions > 0.3 mm must be prevented. The jelly filling inside the tubes can be removed using a tissue soaked in turpentine. It is advisable to cap the cable-ends during storage. Options Cables for outdoor use only. Non-standard cable constructions, colours, details and/or additional information regarding specifications are available on request. 4

Revision Rev. Description Date Init. 02 OM3+ changed to OM4 12/10/09 JW 03 OS2 added 30/11/09 JW 04 Extended description watertightness, adjust max. Pulling tension (short-term) 22/03/10 SN 05 Changed energy and weight 22/11/10 TvR 06 Add Circuit integrity 06/02/12 SN Date: 15/07/08 Page 1 of 1 Part Number: Orig.: SN Review: GCDG 5