Experimental Evaluation of a Gas Engine Driven Heat Pump Incorporated with Heat Recovery Subsystems for Water Heating Applications

Similar documents
The Performance of Mixture Refrigerant R134a/R152a in a Novel Gas Engine-Driven Heat Pump System

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Performance of an Improved Household Refrigerator/Freezer

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Shortcut Model for Predicting Refrigeration Cycle Performance

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Modelling the Performance of a Diffusion Absorption Refrigeration System

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

Performance investigation of Air-conditioning system using ejector as expansion device

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Compendium DES July 2016, CARN

Adsorption refrigeration system using waste heat

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Global Journal of Engineering Science and Research Management

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer

System Modeling of Gas Engine Driven Heat Pump

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

The Effect of the Ventilation and the Control Mode on the Performance of a VRV System in Cooling and Heating Modes

Compression of Fins pipe and simple Heat pipe Using CFD

Combination unit to support instruction in Thermodunamics, Fluid Mechanics, and Heat Transfer

Control Method Of Circulating Refrigerant Amount For Heat Pump System

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

INTERNATIONAL JOURNAL OF APPLIED ENGINEERING RESEARCH, DINDIGUL Volume 1, No 4, 2011

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

HEAT PUMPS WITH HYDROCARBONS AS REFRIGERANTS FOR SMALL RESIDENTIAL BUILDINGS

DEVELOPMENT OF A DYNAMIC HEAT PUMP DRYER TEST BENCH TO DEMONSTRATE ENERGETICAL OPTIMIZATION POSSIBILITIES BY REPLICATING REAL LIFE DRYING PROCESSES

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

MINIMISING THE RISK OF WATER HAMMER AND OTHER PROBLEMS AT THE BEGINNING OF STAGNATION OF SOLAR THERMAL PLANTS- A THEORETICAL APPROACH

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

THERMAL ANALYSIS OF CAR AIR COOLER

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

DIRA S.L. (Desenvolupament, Investigació i Recerca Aplicada S.L.)

EXPERIMENTAL EVALUATION OF CONDENSATION HEAT TRANSFER COEFFICIENT OF R-417A IN HORIZONTAL TUBES

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Simscape Refrigerant Loop Product

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Efficiency of Non-Azeotropic Refrigerant Cycle

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

DEMONSTRATION OF A MICROCHANNEL HEAT EXCHANGER FOR OPERATION IN A REVERSIBLE HEAT PUMP SYSTEM

Enhancement of COP in Vapour Compression Refrigeration System

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

IR-REVERSIBILITY ANALYSIS OF A SPLIT TYPE AIRCONDITIONER USING R600a AS REFRIGERANT

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

Numerical Simulation of a New Cooling System for Commercial Aircrafts

Brazed Plate Heat Exchanger for CO Applications

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Figure 1: Schematic of internal heat exchanger vapor-injection cycle

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

A study of Transient Performance of A Cascade Heat Pump System

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Experimental Study on the Performance of Twisted Capillary Tube

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Transcription:

Experimental Evaluation of a Gas Engine Driven Heat Pump Incorporated with Heat Recovery Subsystems for Water Heating Applications E. Elgendy 1,*, G. Boye 1, J. Schmidt 1, A. Khalil 2, M. Fatouh 3 1 Institute of Fluid Dynamics and Thermodynamics, Faculty of Process and System Engineering, Otto-von-Guericke University, Universitätsplatz 2 D-39106 Magdeburg, Germany 2 Mechanical Power Engineering Department, Faculty of Engineering, Cairo University, Giza 12316, Egypt 3 Mechanical Power Engineering Department, Faculty of Engineering at El-Mattaria, Helwan University, Masaken El-Helmia P.O., Cairo 11718, Egypt * Corresponding author. Tel: +493916712558, Fax: +493916712762, E-mail: essam.elgendy@st.ovgu.de Abstract: Engine waste heat recovery represents one of the main advantages of a engine heat pump (GEHP) as compared to conventional heat pump system. Engine waste heat can be recovered to heat the supply water (at high ambient air temperature) or to evaporate the refrigerant in the refrigerant circuit (at low air ambient temperature). At the middle range of ambient air temperature (10:15 C), the two possibilities are valid but the GEHP performance is different. The present work is aimed at comparing the performance characteristics of the engine heat pump with waste heat recovery subsystems for supplying the hot water demands. In order to achieve this objective, a test facility was developed and then experiments were performed over a wide range of condenser water inlet temperature (34 C to 48 C) and at ambient temperature of 13 C. Performance of the engine heat pump was characterized by the supply water outlet temperature, heating capacity, engine energy consumption and primary energy ratio. The results showed that a water outlet temperature up to 70 C is obtained when the recovered engine heat is transferred to the supply water circuit. On the contrary, a higher condenser heating capacity (13%) and higher engine energy consumption (12.8%) are obtained when the recovered engine heat is transferred to the refrigerant circuit. Furthermore, primary energy ratio of the engine heat pump is increased by 17.5% when recovered engine heat is transferred to the supply water circuit. Also, GEHP incorporated with heat recovery subsystems can be used for utilizing the waste heat to provide efficient supply of hot water. Keywords: Gas engine heat pump, Heating mode, Water heating, Primary energy ratio, Engine waste heat recovery. 1. 0BIntroduction In Europe, more than 50% of the total final energy consumption depends on fossil fuel [1]. However, environmental pollution problems increase with consumption of fossil fuels. In order to solve these problems, a development for alternative energy sources and improvement of energy utilization efficiency are required. Heat pumps (HPs) play an important role in solving energy and environment problems as they can improve the overall energy utilization efficiency and can work with environmentally friendly refrigerants [2-4]. Heat pumps can be divided into many categories according to energy sources, namely electric driven heat pumps (EHPs), ground-source heat pumps (GSHPs), solar-assisted heat pumps and engine driven heat pumps (GEHPs). A GEHP usually consists of a reversible vapor compression heat pump with an open compressor driven by an engine. In recent years, the GEHP has been paid more attention due to its advantage of reducing the energy consumption, especially in the heating process. Another two advantages of the GEHP are (1) the ability to recover the waste heat released by the engine cylinder jacket and exhaust and (2) the easy modulation of compressor speed by adjusting the supply. Therefore, the GEHP has a better performance than that of the electric driven heat pump (EHP), especially in the heating mode [5]. 891

Performance characteristics of the GEHP during heating mode were evaluated by many investigators using theoretical modeling [5-7] and experimental approach [8]. Regarding to theoretical modeling of the GEHP, Zhang et al. [5] analyzed the effect of both ambient temperature and engine speed on t he heating performance of air to water GEHP based on steady state model. Their results proved that the engine speed had a remarkable effect on both the engine and the heat pump, but ambient air temperature had a little influence on the engine performance. Yang et al. [6] reported an intelligent control simulation model for the GEHP system in heating mode to study the dynamic characteristics of the system. The results showed that the model was very effective in analyzing the effects of the control system. The steady state accuracy of the intelligent control scheme was higher than that of the fuzzy controller. Sanaye and Chahartaghi [7] predicted the performance of the GEHP under cooling and heating operating modes and then compared the simulation and experimental results for various amounts of suction and discharge pressures, fuel consumption and coefficient of performance. They noted that error percentages of suction and discharge pressures, fuel consumption and coefficient of performance are 3.4%, 4%, 6.7% and 7.2% for cooling mode, respectively, and 3.7%, 5.4%, 8.1% and 7.8% for heating mode, respectively. Regarding to the experimental studies of the GEHP, Lazzarin and Noro [8] evaluated the performance of S. Nicola plant in Vicenza during three years of operation. Plant heating loads are supplied using the GEHP and two condensing boilers. Recovered engine heat is used in water heating. The economic analysis was taken into account while the energy efficiencies were not taken into considerations. The above review revealed that various investigations on m odeling of the GEHPs are available in the literature while there is a lack of experimental data on the GEHPs working with R22 alternatives such as R410A. Thus, the present work is carried out with the aim of evaluating the performance characteristics of the GEHP used in water heating incorporated with different heat recovery sub-systems. In order to achieve this aim, a test facility of the GEHP is constructed and equipped with the necessary instrumentation. This paper is organized as follows. The experimental apparatus to predict the performance of characteristics of the GEHP is described in Section 2 while the data reduction manipulation is given in Section 3. This is followed by the experimental results and discussion in Section 4. Finally, conclusions based on the present work results are reported in Section 6. 2. Experimental apparatus Fig. 1 shows a s chematic diagram of the experimental apparatus, which includes three circuits; namely primary working fluid circuit, engine coolant circuit and secondary working fluid circuit. R410A is used as a primary working fluid while both air and water are used as secondary heat transfer fluids at the heat source (evaporator) and the heat sink (condenser). In the engine coolant circuit, both ethylene-water mixture (65% by volume) and propylene-water mixture (45% by volume) are used as cooling mediums. Pre-calibrated PT100 sensors are used to measure operating temperatures while digital pressure gauges are used to determine the operating pressures at four locations in the refrigerant circuit of the heat pump. The mass flow rate of refrigerant is measured using KROHNE Optimass 7000-T10 while engine coolant and water flow rates are measured using Ultego-II flow sensors. The measurement locations are shown in Fig. 1. All the measuring instruments have been installed and connected to 64 channels in the data acquisition cards (FP-1000). The control system has been established using PRIVA software which provides several possibilities for indoor unit selection and consequently system operation. All the measured data are recorded using DIAdem software and analyzed using an EES program [9] to evaluate the system performance. Performance 892

characteristics of the system in both cooling, heating and combined modes were published by Elgendy et al. [10-12]. Evaporator V Subcooler 13 8 2 9 V 4 V 3 F Flow 28 p Pressure Sub heat exchanger ϑ Temperature 12 11 V 6 Radiator Heat 23 22 24 recovery 18 V 5 19 26 25 F 5 10 7 F 1 p 3 WP 1 WP 2 17 Condenser 16 6 p 4 Thermostat F 2 5 Reversing valve 21 Engine 2 p 2 20 WP 3 F 4 27 F 3 Hot water tank (1) 14 Hot water tank (2) 3 4 V 1 15 Oil separator Compressor (2) Compressor (1) 1 p 1 Accumulator R410A Propylene glycol-water Ethylene glycol-water Water Fig. 1. Schematic diagram of the experimental apparatus with measuring point locations. 2.1. Primary working fluid circuit The primary working fluid circuit is a vapor compression heat pump. It comprises an expansion device, an evaporator, an open compressor and a condenser followed by a subcooler. The expansion device is an electronic expansion valve whereas the compressor is a scroll open type with swept volume of 104cm 3 /rev. The type of condenser is a plate heat exchanger with a heat transfer area of 4.6m 2. Two pressure-stats, one on the suction side and the other on t he discharged side, are used to protect the compressor from under and over operating pressures. If the pressure exceeds its limits, the compressor would be automatically disconnected. In order to reduce the heat transfer to and from the surroundings, the primary fluid circuit is thermally insulated. As the refrigerant flows to the compressors (state point 1), the compressors raise the pressure of the refrigerant and deliver superheated vapor (state point 2) to the condenser (state point 5) through an oil separator and a reversing valve. The condensation heat of refrigerant vapor is released to the water flowing through the condenser. Thus, R410A vapor gets condensed (state point 6) and its mass flow rate is measured using flow-meter F 1 before it flows to the sub-cooler. The liquid refrigerant in the sub-cooler is sub-cooled (state point 8) by transfer its heat to the throttled refrigerant flowing through valve V 2. Then, the refrigerant is throttled using expansion devices V 3 and V 4 and evaporated inside either the evaporator or the sub heat exchanger using the heat transferred from either ambient air or the recovered heat from the engine, respectively. Superheated refrigerant coming out of sub-cooler (state point 10), 893

sub heat exchanger (state point 12) and outdoor unit (state point 13) are mixed (state point 15) before entering the accumulator and then returning back to the compressors (state point 1). 2.2. Secondary fluid circuit The experimental apparatus has two secondary heat transfer fluid circuits; namely hot water circuit and outdoor air circuit. The hot water circuit contains a hot water tank of 1m 3 capacity, a hot water pump, a condenser and control valves. The water pump (single phase, variable speed) is used to suck and pump the hot water through the condenser and hot water pipeline. The hot water flow rate is adjusted via pump speed. The hot water circuit is thermally insulated to minimize heat loss. The outdoor air circuit consists of an air filter, a fan and an evaporator. The hot water coming out of the condenser (state point 17) is pumped to a storage tank (1) using variable speed water pump WP 1. Storage tank (1) is used for hot water coming from the engine heat recovery while storage tank (2) is used for the hot water coming out of the condenser. The volume flow rates of hot waters are measured using ultrasonic flow meters F 2 and F 5, respectively. 2.3. Engine coolant circuit The engine coolant circuit includes a engine, a coolant tank, a coolant pump, valves and coolant pipeline. Coolant discharged from the coolant pump (state point 20) is heated by the heat released from the engine block and exhaust (state point 21). The heated coolant returns to the coolant pump by making a shortcut via a thermostat valve when the coolant temperature is low (lower than 53 C) at engine start-up. When the coolant temperature is high (higher than 53 C) the coolant flows into sub heat exchanger while it flows through all of sub heat exchanger, radiator and heat recovery heat exchangers when the coolant temperature is very high (higher than 67 C). The outlet coolant from both heat recovery heat exchanger (state point 25) and radiator (state point 26) is mixed (state point 27) and its volume flow rate is measured using ultrasonic flow meter (F 3 ) before returning back to the coolant pump. Heat gained in the heat recovery heat exchanger is supplied to the water in the tank (1) using propylene-water mixture as a working medium (state points 18 and 19). According to engine heat recovered utilization (from the engine block and exhaust ), the system can be worked in two sub modes: Mode-I: in which the recovered engine heat is transferred to the secondary water circuit in order to reach higher hot water supply (using the heat recovery heat exchanger). So, valves V 3 and V 5 are closed while V 6 is open. Mode-II: in which the recovered engine heat is transferred to the primary refrigerant circuit to evaporate the working fluid, especially at low ambient air temperature (using the sub heat exchanger). Hence, valves V 3 and V 5 are open while V 6 is closed. 3. Data reduction Using the measured data of operating pressures and temperatures of R410A, ethylene glycolwater mixture, propylene glycol-water mixture and water, the specific enthalpy values at the inlet and outlet of each component (h 1 h 27 ) are estimated. Then, energy and mass balances are carried out for the main components of the engine heat pump to compute their loads in addition to the overall system performance. Condenser heat load ( Q con ) can be written based on either primary working fluid (Eq. 1.a) or secondary working fluid (Eq. 1.b) as follows; = M (h h ) (1.a) Qcon ref,p 5 6 894

and are = V ρ (h h ) (1.b) Qcon con,w w 17 16 Applying energy balance around sub-cooler, the secondary refrigerant mass flow rate ( M ) flowing through sub-cooler can be calculated as follows; Q M sub ref,s = (h h ) (2.a) where, 10 9 ref, s = M (h h ) (2.b) Qsub ref,p 7 8 M ref,p is the primary refrigerant mass flow rate, which is measured using flow meter FR1R. Gas engine heat recovery ( Q ) can be calculated using Eq. (3); HR = V ρ (h h ). (3) QHR hw w 19 18 Ultrasonic flow meters FR2R FR5R used to measure condenser water ( V con, w ) and hot water ( V hw ) volume flow rates through the condenser and heat recovery heat exchanger, respectively. Primary energy ratio (PER), engine heat consumption ( Q ) and total heating capacity ( Q tot ) are the main parameters to be considered in the performance evaluation of the GEHP [13]. PER and Q can be expressed as follows; PER tot Q tot = Q, (4) Q = Q + Q, (5) con HR Q = V LHV, (6) where LHV is the lower heating value and V diaphragm meter. is the measured volume flow rate using 4. 3BResults and discussions Fig. 2 shows comparison of performance characteristics of the GEHP for the prescribed mode-i and mode-ii and at ambient temperature of 13 C. In mode-i, recovered engine heat is transferred to the water supply while recovered engine heat is transferred to the refrigerant in mode-ii. The system hot water outlet temperature was adjusted between 35 C and 70 C to 895

Outlet water temperatures ( C) 100 80 60 40 20 0 ϑ cond,wat ϑ h,wat ϑ amb,av =13 C Mode-I Mode-II (A) 30 25 Mode-I Mode-II Heat loads (kw) 20 15 10 5 0.. Q cond Q. Q HR (B) 1.4 1.3 Mode-I Mode-II PER (-) 1.2 1.1 1.0 0.9 (C) 34 36 38 40 42 44 46 48 50 Condenser water inlet temperature ( C) Fig. 2. Effect of condenser water inlet temperature on the performance characteristics of the GEHP for Mode-I and Mode-II. (A) outlet water temperatures, (B) heat loads and (C) PER. provide heating requirements for several applications like shaving, residential dish washing and laundry [14]. 896

4.1. Effect of condenser water inlet temperature Measured condenser and heat recovery water outlet temperatures against the condenser water inlet temperature are presented in Fig. 2.A, which indicates that condenser and heat recovery water outlet temperatures increase when condenser water inlet temperature increases. Variations of actual heat loads with condenser water inlet temperature are shown in Fig. 2.B. It is evident from this figure that total heating capacity and engine heat recovery decrease while engine energy consumption Q increases as condenser water inlet temperature increases. It is observed that both of the condenser and heat recovery water temperature differences decrease causing the decrease of total heating capacity. In general, as the condenser water inlet temperature changes from 37 C to 48 C, total heating capacity decreases by 8.3% and 4.7% while engine energy consumption increases by 14.1% and 11.9% for mode-i and mode-ii, respectively. The effect of condenser water inlet temperature on PER can be predicted from Fig. 2.C. A higher condenser water inlet temperature yields a lower PER. This trend is mainly due to both decrease in total heating capacity and increase in the engine energy consumption as shown in Fig. 2.C. Clearly, primary energy ratio of the GEHP decreases by 27.2% and 17.3% as the condenser water inlet temperature varies from 37 C to 48 C for mode-i and mode-ii, respectively. 4.2. Comparison between mode-i and mode-ii Comparison of the measured condenser and heat recovery water outlet temperatures for mode-i and mode-ii are presented in Fig. 2.A. In the two modes, the condenser water outlet temperature lies between 35 C and 50 C. For mode-i, a higher hot water temperature (up to 70 C) can be achieved as a result of recovered engine heat transfer. Variations of actual heat loads for the modes are shown in Fig. 2.B. It is evident from this figure that condenser heating capacity and engine energy consumption are high when recovered engine heat is transferred to refrigerant. In general, both condenser heating capacity and engine energy consumption increase by 13% and 12.4% as an average values, respectively. So, it is better to transfer recovered engine heat to the refrigerant when one needs a large amount of heat at lower range of temperature (35 C:50 C) while it is better to transfer engine heat to water when a higher water temperature (up to 70 C) is required. The effect of the condenser water inlet temperature on the PER for the two modes can be predicted from Fig. 2.C. A higher PER can be reached when the recovered engine heat is transferred to the water. This can be attributed mainly to the higher engine heat recovery. Clearly, primary energy ratio of the GEHP increases by 17.5% as an average value over the entire range of the condenser water inlet temperature (from 37.2 C to 48 C). 5. Conclusion In the present work, performance characteristics of R410A engine heat pump have been experimentally compared under two different modes of heat recovery utilization. In mode-i, recovered engine heat is transferred to the water supply while recovered engine heat is transferred to the refrigerant in mode-ii. Based on t he reported results, the following conclusions are drawn: - Hot water outlet temperatures between 35 C and 50 C are obtained during the considered modes. - Water outlet temperatures up to 70 C can be reached in a separate tank when recovered engine heat is transferred to water. 897

- As the condenser water inlet temperature varies from 37 C to 48 C, total heating capacity decreases by 8.3% and 4.7% while engine energy consumption increases by 14.1% and 11.9% for mode-i and mode-ii, respectively. - Primary energy ratio of the GEHP increases by 17.5%, when recovered engine heat is transferred to water. Acknowledgment The Authors are grateful for the installation of the testing plant and the financial support provided by Wärmetechnik Quedlinburg (WTQ) GmbH. The financial support of the Egyptian government for the Ph.D. of Mr. Elgendy is gratefully acknowledged. References [1] H. Laue, Heat Pumps, Heinloth K. Renewable Energy, Germany, Springer Berlin Heidelberg, 2006. [2] J. P. Meyer, G. P. Greyvenstein, Hot water for homes in South Africa with heat pumps, Energy 1991, 16(7), pp.1039 44. [3] G. P. Greyvenstein, J. P. Meyer, The viability of heat pumps for the heating of swimming pools in South Africa, Energy 1991, 16(7), pp.1031 1037. [4] S. Garimella, Innovations in energy efficient and environmentally friendly spaceconditioning systems, Energy 2003, 28(15), pp.1593 1614. [5] R. R. Zhang, X. S. Lu, S. Z. Li, W. S. Lin, A. Z. Gu, Analysis on the heating performance of a engine driven air to water heat pump based on a steady state model, Energy Conversion and Management 2005, 46, pp.1714 1730. [6] Z. Yang, Z. Haibo, F. Zheng, Modeling and dynamic control simulation of unitary engine heat pump, Energy Conversion and Management 2007, 48(12), pp.3146 3153. [7] S. Sanaye, M. Chahartaghi, Thermal modelling and operating tests for the enginedriven heat pump systems, Energy 2010, 35(1), pp.351-363. [8] R. Lazzarin, M. Noro, District heating and engine heat pump: economic analysis based on a case study, Applied Thermal Engineering 2006, 26, pp.193 199. [9] S. A. Klein, EES-Engineering Equation Solver, Professional Version, Middleton, WI, F- Chart Software, 2009. [10] E. Elgendy, J. Schmidt, Experimental study of engine driven air to water heat pump in cooling mode, Energy 2010, 35(4), pp.2461-2467. [11] E. Elgendy, J. Schmidt, A. Khalil, M. Fatouh, Performance of a Gas Engine Driven Heat Pump for Hot Water Supply Systems, Energy 2011, In press. [12] E. Elgendy, J. Schmidt, A. Khalil, M. Fatouh, Performance of a Gas Engine Heat Pump using R410A for Heating and Cooling Applications, Energy 2010, 35(12), pp.4941-4948. [13] K. Taira, Development of a 2.5-RT multiple-indoor-unit engine heat pump, ASHRAE Trans 1998, 24, pp.982-988. [14] ASHRAE, ASHRAE handbook, application, Atlanta, American Society of Heating Refrigerating and Air-conditioning Engineers, 2007. 898