CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

Similar documents
Forced draught gas burner

Forced draught gas burner

Light oil - kerosene burner

Light oil burners. One stage operation

Light oil / kerosene burner

TWO STAGE HEAVY OIL BURNERS

Installation, use and maintenance instructions. Light oil burner. Two stage operation CODE MODEL TYPE RL X (1) - 08/2012

Gas-Gebläsebrenner Brûleur gaz à air soufflé Forced draught gas burner Gasventilatorbrander Quemador de gas de aire soplado

Oil burners Brûleurs fioul Stookoliebranders

Parts Available from

RL 70/2-100/2-130/2 Low - High Operation

INSTRUCTION MANUAL FOR OIL BURNER MODELS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

RL 28/2-38/2-50/2 Low - High Operation

15 20 kw kw kw

INSTALLATION AND MANINTENANCE INSTRUCTIONS

EURO-OIL SERIES TYPES G.. G../. OR.. OR../. F.. FR..

Single stage operation oil burners

INSTRUCTION MANUAL FOR OIL BURNER MODELS

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

Single stage operation oil burner

Installation & Maintenance Manual

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction MOL1650 T3N 323 2FH.

SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.)

ST 40 Oil Burner. Installation & Maintenance Manual

RETROFIT APPLICATIONS ONLY

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

- Instruction for ligth oil burner models BTS /05. Edition

Single stage operation oil burner

Interrupted Ignition Series Oil Primary Control

en Direct oil-fired space heaters HD... Operator's manual

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.)

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

Weishaupt dual fuel burners Sizes 30 to 70 Version 1LN (NO X -reduction on gas operation) 1/2003 CA

MONOBLOCK HEAVY OIL BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL

JUMBO INDIRECT FIRED DIESEL HEATER OPERATING INSTRUCTIONS

Oil burners fuel unit with solenoid valve

PEGASUS F2 N 2S. CAST IRON GAS BOILER for heating with electronic ignition and flame control INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

Forced draught natural gas/propane burner

Thermo 230 / 231 / 300 / 301 / Troubleshooting

WARNING WARNING TROUBLESHOOTING GUIDE INTEGRATED FURNACE CONTROL MODULE

Oil burners fuel unit with solenoid valve

LAE10 LFE10. Use. Series 02

LATTNER BOILER COMPANY 9.5 HP Low-NOx Installation and Start-Up Checklist for Dry Cleaners

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 10 E R

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Forced draught gas burners

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

BGH Series Hot Surface Ignition Control

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 30 A

Indirect gas-fired air heater

Light oil burners. Low - High Operation. Installation, use and maintenance instructions CODE MODEL TYPE

Condensing, pre-mixed, wall-hung gas boilers with water tank

Installation & Maintenance Manual

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

INSTALLATION AND OPERATING INSTRUCTIONS JAKA HFD JAKA HFS

Ideasandformsinevolution

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

MMG Gas burner safety control

Oil TRIANCO. EuroStar Range BURNER DETAILS TRIANCO - OIL BURNER. To be retained by householder

Light oil burner. Progressive two-stage or modulating operation. Installation, use and maintenance instructions RL 1000/M C10 TC FS X

Heating Equipment. gas boilers RX GB. installation and servicing instructions

RIELLO 40 GS/M SERIES

Flame Safeguards LFE10. Building Technologies HVAC Products

UV Flame Supervision System

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 45 A2.2

Columbia Boiler Company

Gas burner automatic safety control MMI / 811.1

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

Forced draught gas burner

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

UNDERCOUNTER SERVICE MANUAL. Ecoboiler UC4L 2.4kW Ecoboiler UC10L 2.8kW Ecoboiler UC10L 5.6kW Ecosmart UC4L 2.

C Tahiti. condensing

MMI (40-34) Gas burner safty control

Service manual IC LF/FLF/R/FR. Flatwork ironers

BENSON LINEAR RADIANT TUBE

Providing sustainable energy solutions worldwide. Installation- and maintenance instruction B 45A

BIX B-One 100 kw INSTALLATION GUIDE

Grant UK VortexBlue. 21, 26 and 36kW Blue Flame Oil Boiler Range. Supplementary Installation, Servicing and User Instructions

RS /E-EV C01 SERIES

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

CSD-1 COMMERCIAL BOILER CONTROLS

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

DOMESTIC HOT WATER Follow operational sequence

Installation and operating instructions B1FUV Classic

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

EUROBOX SERIES TYPES CM...N SM...N MM...N

Flame Safeguards LFE10. Building Technologies HVAC Products

AQUARIUS 45 MARINE SERVICE MANUAL

MICROFLAT SERIES TYPES C.../U T X

Single stage operation forced draught natural gas/propane burner

Transcription:

Installation, use and maintenance instructions Heavy oil burner CODE MODEL TYPE 3434985 PRESS 60 N 616 T80 3434986 PRESS 60 N 616 T80 291 (2) - 01/2009

Thermal power - Output Operation Fuel Electrical supply Motor Ignition transformer Heaters Absorbed electrical power Pump 171 / 342-684 kw - 15 / 30-60 kg/h Two stages Oil with max. viscosity at 50 C: 150 mm 2 /s (20 E) Three phase: 220V +10% -10% ~ 60Hz without neutral 380V +10% -10% ~ 60Hz with neutral 4.8 A / 220V - 2.8A / 380V Primary: 2 A - Secondary: 2 x 6.5 kv / 35 ma 4.2 kw 5.8 kw 110 kg/h at 20 bar Fig. 1 Fig. 1 1 - Suction line 2 - Return line 3 - Pump pressure adjustment screw 4 - Manometer plug (G 1/8) Quantity 2 2 Accessories Flexibles tubes Nipples 5 - Vacuometer plug (G 1/2) 2 Seals 6 - Air shutter opening motor 7 - Control box reset push-button and lock-out lamp 4 Screws 8 - Reset push-button of the motor over load relay 1 Gasket for flange 9 - Regulating bush for combustion head 10 - Sheathed filter for the thermometer 2 * Extensions for bars 11 - Valves group 12 - Manometer with protection valve 16 - Wiring terminal board 13 - Adjustment thermostat 17 - Fair leads 14 - Pre-heater relay 18 - Back-pressure valve 15 - Ignition transformer DIMENSIONS * For extended - head version 1

COMBUSTION CHAMBER PRESSURE - MAXIMUM OUTPUT (two nozzles in operation) mbar kg/h kw When the burner operates with only one nozzle, the pressurization conditions are improved and no problems arise. Minimal fuel capacity with only one nozzle: 15 kg/h - 171 kw Front plate detail for boiler mounting Note for the extended combustion head version Apply the extensions provided as accessories for the burner withdrawing. 2

FUEL OIL GRAVITY FEED SYSTEMS Gravity system (fuel oil with viscosity max. 7 E at 50 C) Pump priming: loose the tap of the vacuometer plug 5) (fig. 1) and wait for the fuel flow. H: Difference in the pipes height. L: Length of the suction pipe. H meters ø 1 gas L meters ø 1 1/4 gas 0 6 10 0.5 11 17 1 16 24 1.5 21 31 2 26 38 SUCTION SYSTEM (fuel oil with viscosity max. 7 E at 50 C) Not advised, to be used only in case of previously existing system. Never overcome the max. depression of 0.5 bar (38 cm Hg). With higher values the fuel emanates gas. The pipes shall be perfectly sealed. When the tank is placed below of the burner level, the return pipe should reach the same level of the suction pipe. In this case the foot valve is not required. H meters ø 1 1/4 gas L meters ø 1 1/2 gas 0 22 45 0.5 19 39 1 16 33 1.5 13 27 2 10 21 2.5 7 15 3 0 8 RING SYSTEM (for heavy oil with viscosity up to 65 E / 50 C) 1 - Tank (properly heated for heavy oil) 5 - Forwarding pump 2 - Filter (with resistance for oil >7 E/50 C) 6 - Manometer 3 - Burner 7 - Burner pump 4 - Couple of cocks (excluding the burner) 8 - Pressure adjuster Notice: All the pipes have to be properly seized, sealed and heated (elect. resistance or hot steam or water) to let the fuel flow. Warning: Before to put the burner in operation verify that no obstruction exists into the pipes, any obstruction may damage the sealing of the pump. 3

M ELECTRICAL WIRING CONNECTIONS (carried out by the factory) TB 4 RMO88.53A2 12 15 11 16 18 9 5 1 8 FR 13 17 10 7 8 6 11 SM MV2 HS1 TE TA ST0 2 ST1 5 TM S TB MV M 3 3 4 1 R2 R1 ST2 - + 1 2 3 4 5 6 7 8 9 2 4 6 95 RT F A1 CR A2 1 3 5 2 4 6 1 3 5 14 13 96 A2 CMV A1 Tm V1 V2 TB MB L1R L2R L3R N L1 L2 L3 L N S3 T1 30 T2 T6 T8 V21 V22 D2613 KEY TO LAYOUT CMV Fan motor contactor CR Pre-heart contactor F Suppressor FR Photoresistance MB Wiring terminal board MV Fan motor RMO Control box RT Therminal overload S Pre-heart SM Servomotor TA Ignition transformer TB Earth of the burner TE Start-up and adjustment thermostat Tm Minimum value contact thermostat TM Maximum value contact thermostat V Electromagnetic valves 4

ELECTRICAL CONNECTIONS TO THE WIRING TERMINAL BOARD (to be carried out by the installer) D2644 KEY TO LAYOUT H Remote lock-out signal IN Manual burner stop switch MB Wiring terminal board TL Limit control device system TR High-low mode control device system TS Safety control device system 220V 380V A Ampere T10 T6 B mm 2 1,5 1,5 C Ampere T16 T10 D mm 2 4 2,5 NOTICE - Leads minimal section: 1,5 mm 2. WARNING For supply at 220 V make the triangle connection on the pre-heater and on the motor (the original connection is star for 380 V). TWO STAGE OPERATION It can be achived by the thermostat connected to 14-15 wiring terminal board (removing the bridge) controlling 2 nd valve. PRE-HEATER RESISTANCES CONNECTIONS 5

FASTENING OF THE ELECTRICAL WIRES All the wires, which have to be connected to the wiring terminal board 16) (fig. 1) shall pass through the fair leads 17) (fig. 1) as per this scheme. 1 - Pre-heating resistances three phase supply: fair lead Pg 21 2 - Motor three phase supply: fair lead Pg 16 3 - Single phase supply and safety thermostat: fair lead Pg 13.5 4 - Control thermostat: fair lead Pg 13.5 5-2 nd stage thermostat: fair lead Pg 13.5 6 - Pre-sheared holes Further prospective signals or controls can be connected to the burner wiring terminal board by removing the metal weldnuts from the pre-sheared holes and inserting a commun fair lead for the passage and the clamping of the leads. NOTES - Carry out a safe earth connection. - Check the stop of the burner, by opening the boiler thermostat and the burner lock-out, by disconnecting the lead from the flame probe. 6

CHOICE OF NOZZLES - OF THE PUMP PRESSURE OF THE COMBUSTION HEAD ADJUSTMENT Nozzles delivery Pump pressure Combustion head adjustment Maximum output Nozzle GPH (45-60 ) 20 bar kg/h 25 bar kg/h 2,50 + 2,50 30,00 34,00 3,00 + 3,00 36,00 40,60 3,50 + 3,50 42,00 47,40 4,00 + 4,00 48,00 54,20 4,50 + 4,50 54,00 61,00 5,00 + 5,00 60,00 - kg/h In case of very heavy oil it is advised to use high wear resistance nozzles (for instance Monarch F 80 H0) Set-point Advised pressure - Light oil: 20 bar - Heavy oil: 25 bar Rated deliveries of the nozzles are indicated on the above list and refer to a light oil having viscosity from 3 to 5 E at 50 C pre-heated at 100 C. The effective delivery may vary of ± 5% against the rated one. In case of requirement of intermediate values, the pump pressure or the nozzles match could be changed. The pump is set by the factory at 20 bar. Combustion head adjustment Turn the screw A till the set-point, detected from the diagram, is on line with the washer B. B Set-point 4 A 7

ADJUSTMENT OF THE AIR DAMPER MOTOR STOP - Blue lever This lever leaves the factory vertically positioned and corresponds to the complete closing of the air damper. A partial opening of the air damper might be obtained by moving leftwards this lever (+ on the label). The new position of the air damper is detectable when the burner is off. Do not overcome the position of the orange lever for the 1 st stage. 1 st STAGE - Orange lever The orange lever controls the air damper position for the first flame, it is adjustable both for opening and closing. Black lever Red lever Orange lever Blue lever Opening + - Closing 2 nd STAGE - Red and black levers The red lever controls the air damper position for the second flame, it is adjustable both for closing and opening. The black lever controls the opening of the second oil valve and it must always anticipate - for a bit - the red lever, but never the orange one. BURNER START-UP PROGRAM Thermostat Normal Lock-out because no ignition D2894 Motor Ignition transformer 1 st flame valve 2 nd flame valve Lock-out lamp MOTOR LOCK-OUT It is caused by the motor overload relay if overload occurs or no phase. Reset: push the buttons 7 and 8) fig. 1. 8

SPRAY TEMPERATURE ADJUSTMENT Thermostats for: adjustment - maximum value - minimum value Adjustment thermostat: it prevents the burner start up if the fuel temperature has not reached the required value for a good spray as indicated in the diagram below. Viscosity at 50 C Sheath for thermometer Adjusting knob of thermostat Pre-heater Purge Spray temperature Example: fuel oil with viscosity of 7 E at 50 C is pre-heated at approximately 110 C. The thermostat has to be generally set at a value higher than the required one: (120 C indicated on the knob to get approx. 100 C at the nozzles). The value read has to be done after some minutes of performance and later the necessary adjustments could be carried out. Minimum value contact thermostat: it intervenes by stopping the burner if the fuel temperature decreases under the value necessary for a good combustion. Maximum value thermostat: it switches off the resistances when in case of failure of the adjustment thermostat, the temperature increases inside the pre-heater. In case of abnormal temperature, make sure of the regular functioning of control thermostat and of the resistance in contact with the probe of the thermostat. The thermostat is calibrated by the factory at 180 C. IMPORTANT NOTICES Pre-heater thermostats substitution. Replace the probe of the new thermostat, after the loosening of the fixing screws of the plates pack, taking care of good contact between the probe and the tubes and the resistance, see drawing. Similarly for the resistance substitution. - If during the operation exceptional changes or too much high temperatures should be detected, verify the continuity of the resistance, using and ohmmeter, contacting the temperature probe (approximately 35 Ohm). Aluminium plate Tubes into aluminium plate Resistance Thermostat probe 9

NOTE - The pre-heater might be provided with a second thermostat of maximum value with manual reset. That thermostat can be used as a switch operating by means of an external commutator, which can take off the current from the pre-heater in case of over-temperature. (Kit code no. 3000800). - Before the burner start-up, verify that the pump is filled of fuel in order to avoid any idling for too long time. - Filters cleaning: periodically clean the filters in order to avoid any trouble at the burner operation. - Supply line filter: positioned on the suction line, it causes the increase of the depression in the pump with the consequent flow of gas and noise. Do not overcome the depression of 38 cm Hg (5 m W.c.) (fig. 1 pos. 5). - Pre-heater filter: (fig. 1 pos. 10) positioned in the delivery line, it causes a decrease of the spraying pressure which is detectable by use of a manometer (fig. 1 pos. 12). MANOMETER PROTECTION VALVE After spray pressure check, it is recommended to cut out the manometer (fig. 1 pos. 12) to avoid pressure shock that it can suffer at every burner starting. Close protection valve when the burner is not working and the manometer indicate 0 bar. 10

BURNER START-UP CYCLE DIAGNOSTICS During start-up, indication is according to the followin table: COLOUR CODE TABLE Sequences Pre-purging Ignition phase Operation, flame ok Operating with weak flame signal Electrical supply lower than ~ 170V Lock-out Extraneous light Key: Off Yellow Green Red Colour code OPERATING FAULT DIAGNOSTICS The control box has a self-diagnostic system, which easily allows identifying the operating faults (RED LED signal). ITo use this function, wait at least ten seconds from the safety lock out, and then press the reset button for a minimum of 3 seconds. After releasing the button, the RED LED starts flashing as shown in the diagram below. RED LED on wait at least 10 s Press button Interval for > 3 s Signal 3 s Signal The pulses of the LED constitute a signal spaced by approximately 3 seconds. The number of pulses will provide the information on the possible faults, according to the table below: SIGNAL PROBABLE CAUSE 2 flashes The flame does not stabilise at the end of the safety time: faulty photocell; faulty or soiled oil valves; neutral/phase exchange; faulty ignition transformer poor burner regulation (insufficient heavy oil). 3 flashes Min. air pressure switch (if installed) does not close: air pressure switch faulty; air pressure switch incorrectly regulated; max. air pressure switch triggered (if installed). 4 flashes Min. air pressure switch (if installed) does not open or light in the chamber before firing: air pressure switch faulty; air pressure switch incorrectly regulated. 7 flashes Loss of flame during operations: poor burner regulation (insufficient heavy oil); faulty or soiled oil valves; short circuit between photocell and earth. 8 flashes 10 flashes Faulty thermostat for oil permissive signal; Heating resistances blown. Wiring error or internal fault. 11

RIELLO S.p.A. I-37045 Legnago (VR) Tel.: +39.0442.630111 http:// www.rielloburners.com Subject to modifications