Caledonian Fire resistant Coaxial Cables

Similar documents
Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Caledonian Flame Retardant Coaxial Cables

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Caledonian fire Resistant signal & Data cables

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Flame Retardant Overall Screened Instrumentation Cables (multicore)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

BS /1000V XLPE Insulation LSZH Sheath Cables

PRODUCT CATALOGUE Norröna

FIRE RESISTANT CABLES

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Photovoltaic Cables EN H1Z2Z2-K

Multi-Core Fire Resistant Cable

High Performance LSZH Fire Resistant Cable

Firecel Safety Cables

Introduction.

SPECIAL ELECTRICAL AND OPTICAL CABLES

Compact Module. Category 6A FTP Cabling System 1.1

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Catalogue Telecommunication Cables INTRODUCCIÓN

CABLES FOR ALARM AND SAFETY SYSTEMS

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

Catalogue Power Cables

Telecommunication Cables

Shipboard & Offshore Cables

Catalogue. Instrumentation & Control Cables

fire resistant cables

FIRE PERFORMANCE CABLE

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

Rolling Stock Cables.

ENHANCED FIRE PERFORMANCE CABLE

The Quality Connection. BETAflam Fire Resistant Safety Cables

Cable technology for highest safety requirements

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

SAS Security and Alarm Safety Cables

F1202 TRACE HEATING. Road & Ramp

Traction Cable Radox 3 GKW

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

OIL & GAS INDUSTRY OTHER INDUSTRIES

CATEGORY 6A FTP RJ45 SOLUTION

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Total Fire Solutions. Includes BS 8519 and the updated BS :

Single core cables with reduced wall thickness

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

S Low loss coax cables with foamed PE

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

Havells Fire Survival Cables

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Braided Sleeving. Mechanical Protection Electrical Insulation Thermal and Fire Insulation Electromagnetic Shielding

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

FIRE RESISTANT CABLES FP200 GOLD

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

STANDARDS INSTALLATION. Certificate No 077m

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

UV RESISTANT ACCORDING TO HD 605 RULE

OFFSHORE CABLES. Top Cable Central Headquarters. Leonardo Da Vinci, number Rubí (Barcelona) Spain

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

UNIKA Universal Cable Cable Specialist

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

DNVGL-CP-0402 Edition February 2016

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Tratos Railway Cables

Tether and Umbilical Cables for Remotely Operated Vehicles

DNVGL-CP-0399 Edition March 2016

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Comtran Cable. Hub-LINK Cables for Transit Applications

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

Flexible Power Cable DLO

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CONNECTION SYSTEMS TRANSIT APPLICATIONS

Low Smoke Zero Halogen

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

FIRE RESISTANT CABLES FP300

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

SOLAR CABLES. Electric cables for solar PV installations

Transcription:

Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg59 b/u Coaxial Cables RG59 B/U FR LSZH Sheath Fire Resistant Tape Copper Clad Steel/Bare Copper P/FP Insulation Copper ire Braid Screen application The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. standards Basic design to MIL-C-17 Fire PerFOrManCe System Flame Retardance (Single Vertical ire Test) (Vertically-mounted bundled wires & cable test) IC 60331-23; BS 6387 CZ; DIN VD 0472-814(F180); CI 20-36/2-1; SS299-1; NBN C 30-004 (cat. F3); DIN 4102-12, 30 depending on lay system N 60332-1-2; IC 60332-1-2; BS N 60332-1-2; VD 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CI 20-35/1-2; N 50265-2-1*; DIN VD 0482-265-2-1* N 60332-3-24 (cat. C); IC 60332-3-24; BS N 60332-3-24; VD 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CI 20-22/3-4; N 50266-2-4*; DIN VD 0482-266-2-4 IC 60754-1; N 50267-2-1; DIN VD 0482-267-2-1; CI 20-37/2-1 ; BS 6425-1* No Corrosive Gas mission IC 60754-2; N 50267-2-2; DIN VD 0482-267-2-2; CI 20-37/2-2 ; BS 6425-2* Minimum Smoke mission IC 61034-1&2; N 61034-1&2; DIN VD 0482-1034-1&2; CI 20-37/3-1&2; N 50268-1&2*; BS 7622-1&2* No Toxic gases NS 02-713; NF C 20-454 note: asterisk * denotes superseded standard. ADDISON 25

ADDISON CABL CONSTRUCTION Conductors: Copper clad steel, solid according to IC 60228 class 1. Insulation: P wrapped with fire resistant silicone rubber compound type I2 as per BS 7655-1.1 or fluoropolymer(fp) compound. Binder: Glass tape Overall Screen: Plain copper wire braid Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1(Thermosetting LSZH compound type S2-S4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Physical AND THRMAL PROPRTIS Temperature range during operation (fixed state): -30 C - +70 C Temperature range during installation (mobile state): -5ºC - +60ºC Minimum bending radius: 8 x Overall lectrical Properties Impedance 75±5Ω Capacitance 67 nf/km Velocity ratio(%) 66 Insulation resistance >2000 Mohm.Km Shield coverage 95% DC resistance Inner conductor 158 Ω/km Outer conductor 9.0 Ω/km Attenuation Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) 50 7.4 2.26 100 10.7 3.26 200 15.7 4.79 400 22.7 6.92 500 25.7 7.84 600 28.7 8.75 860 34.8 10.61 1000 38.0 11.59 26 Caledonian

Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Return Loss Frequency(MHz) Return Loss (db) 30-300 MHz >31dB 300-600 MHz >28dB 600-900 MHz >24dB CONSTRUCTION PARAMTRS Cable Code Conductor Insulation Screen No.x Overall Approx. eight mm mm No. x mm mm kg/km RG59 B/U FR 0.58 ± 0.03 3.70 ± 0.10 m 120 x 0.15 6.20 ± 0.10 60.3 300/500V MIL-C-17 N Rated Voltage Standard IC 60331/BS 6387 NF C32-070-2.2(C1) IC60332-3-24/N50266-2-4 NF C32-070-2.1(C2) IC60332-1-2/N50265-2-1 Flame Retardancy Zero NS 02-713/NF C 20-454 Low Toxicity IC60754-2 N50267-2-2/3 NF C 32-074 Low Corrosivity IC 61034-1&2 N 50268-1&2/NF C32-07 Low Smoke mission IC60754-1 N50267-2-1 DIN 4102-12 Functional Integrity ADDISON 27

ADDISON Fire resistant rg6 a/u Coaxial Cables RG6 A/U FR Aluminium Foil Screen2 Aluminium Foil Screen1 P/FP Insulation Solid Bare Copper Fire Resistant Tape LSZH Sheath application The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. standards Basic design to MIL-C-17 Fire PerFOrManCe System Flame Retardance (Single Vertical ire Test) (Vertically-mounted bundled wires & cable test) IC 60331-23; BS 6387 CZ; DIN VD 0472-814(F180); CI 20-36/2-1; SS299-1; NBN C 30-004 (cat. F3); DIN 4102-12, 30 depending on lay system N 60332-1-2; IC 60332-1-2; BS N 60332-1-2; VD 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CI 20-35/1-2; N 50265-2-1*; DIN VD 0482-265-2-1* N 60332-3-24 (cat. C); IC 60332-3-24; BS N 60332-3-24; VD 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CI 20-22/3-4; N 50266-2-4*; DIN VD 0482-266-2-4 IC 60754-1; N 50267-2-1; DIN VD 0482-267-2-1; CI 20-37/2-1 ; BS 6425-1* No Corrosive Gas mission IC 60754-2; N 50267-2-2; DIN VD 0482-267-2-2; CI 20-37/2-2 ; BS 6425-2* Minimum Smoke mission IC 61034-1&2; N 61034-1&2; DIN VD 0482-1034-1&2; CI 20-37/3-1&2; N 50268-1&2*; BS 7622-1&2* No Toxic gases NS 02-713; NF C 20-454 note: asterisk * denotes superseded standard. 28 Caledonian

Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com CABL CONSTRUCTION Conductors: Bare copper copper wire, solid according to IC 60228 class 1. Insulation: Foamed P wrapped with fire resistant silicone rubber compound type I2 as per BS 7655-1.1 or fluoropolymer(fp) compound. Binder: Glass tape Overall Screen: AL foil(100%)+al braid (70%) Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type S2-S4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Physical AND THRMAL PROPRTIS Temperature range during operation (fixed state): -30 C - +70 C Temperature range during installation (mobile state): -5ºC - +60ºC Minimum bending radius: 8 x Overall lectrical Properties Impedance 75±5Ω Capacitance Velocity ratio(%) 82 Insulation resistance 54 nf/km >5000 Mohm.Km Shield coverage AL foil(100%)+al 70% DC resistance Inner conductor Outer conductor Attenuation 23.1 Ω/km 31 Ω/km Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) 50 5.0 1.5 100 6.4 1.96 200 9.2 2.8 500 14.5 4.4 600 15.9 4.9 800 17.7 5.4 1000 21.9 6.7 1350 24.9 7.6 1750 29.0 8.8 2050 33.1 10.1 2400 36.4 11.1 ADDISON 29

ADDISON Return Loss Frequency(MHz) Return Loss (db) 30-300 >28dB 300-600 >24dB 600-900 >22dB CONSTRUCTION PARAMTRS Cable Code Conductor Insulation Screen No.x Overall Approx. eight mm mm No. x mm mm kg/km RG6 A/U FR 1.02 4.57 ± 0.20 96 x 0.12 7.00 ± 0.20 81.6 300/500V MIL-C-17 N Rated Voltage Standard IC 60331/BS 6387 NF C32-070-2.2(C1) IC60332-3-24/N50266-2-4 NF C32-070-2.1(C2) IC60332-1-2/N50265-2-1 Flame Retardancy Zero NS 02-713/NF C 20-454 Low Toxicity IC60754-2 N50267-2-2/3 NF C 32-074 Low Corrosivity IC 61034-1&2 N 50268-1&2/NF C32-07 Low Smoke mission IC60754-1 N50267-2-1 DIN 4102-12 Functional Integrity 30 Caledonian

Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com Fire resistant rg6 QUaD Coaxial Cables RG6 QUAD FR LSZH Sheath Al-maylar Tape2 Aluminium Braid1 P/FP Insulation Solid Bare Copper Fire Resistant Tape Aluminium Braid3 Al-maylar Tape4 application The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. standards Basic design to MIL-C-17 Fire PerFOrManCe System Flame Retardance (Single Vertical ire Test) (Vertically-mounted bundled wires & cable test) IC 60331-23; BS 6387 CZ; DIN VD 0472-814(F180); CI 20-36/2-1; SS299-1; NBN C 30-004 (cat. F3); DIN 4102-12, 30 depending on lay system N 60332-1-2; IC 60332-1-2; BS N 60332-1-2; VD 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CI 20-35/1-2; N 50265-2-1*; DIN VD 0482-265-2-1* N 60332-3-24 (cat. C); IC 60332-3-24; BS N 60332-3-24; VD 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CI 20-22/3-4; N 50266-2-4*; DIN VD 0482-266-2-4 IC 60754-1; N 50267-2-1; DIN VD 0482-267-2-1; CI 20-37/2-1 ; BS 6425-1* No Corrosive Gas mission IC 60754-2; N 50267-2-2; DIN VD 0482-267-2-2; CI 20-37/2-2 ; BS 6425-2* Minimum Smoke mission IC 61034-1&2; N 61034-1&2; DIN VD 0482-1034-1&2; CI 20-37/3-1&2; N 50268-1&2*; BS 7622-1&2* No Toxic gases NS 02-713; NF C 20-454 note: asterisk * denotes superseded standard. ADDISON 31

ADDISON CABL CONSTRUCTION Conductors: Copper clad steel, solid according to IC 60228 class 1. Insulation: Foamed P wrapped with fire resistant silicone rubber compound type I2 as per BS 7655-1.1 or fluoropolymer(fp) compound. Binder: Glass tape Overall Screen: Screen1: Al-maylar Tape 25% Screen2: Aluminium Braid Screen3: Al-maylar Tape 25% Screen4: Aluminium Braid Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type S2-S4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Physical AND THRMAL PROPRTIS Temperature range during operation (fixed state): -30 C - +70 C Temperature range during installation (mobile state): -5ºC - +60ºC Minimum bending radius: 8 x Overall lectrical Properties Impedance 75±5Ω Capacitance Velocity ratio(%) 82 Insulation resistance 54 nf/km Shield coverage 60% Max.conductor resistance Attenuation >5000 Mohm.Km 24.1 Ω/km Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) 50 4.8 1.5 100 6.7 2.0 200 9.3 2.8 500 15.0 4.6 600 16.9 5.1 800 19.4 5.9 1000 21.6 6.6 1350 24.2 7.4 1750 28.0 8.4 32 Caledonian

Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com 2150 31.5 9.6 2400 32.8 10.0 3000 37.9 11.5 Return Loss Frequency(MHz) Return Loss (db) 30-300 >28dB 300-600 >24dB 600-900 >22dB CONSTRUCTION PARAMTRS Cable Code Conductor Insulation Screen2 No.x Screen4 No.x Overall Approx. eight mm mm No. x mm No. x mm mm kg/km RG6 QUAD FR 1.02 4.60 ± 0.20 80 x 0.12 64 x 0.12 7.55 ± 0.20 92.4 300/500V MIL-C-17 N Rated Voltage Standard IC 60331/BS 6387 NF C32-070-2.2(C1) IC60332-3-24/N50266-2-4 NF C32-070-2.1(C2) IC60332-1-2/N50265-2-1 Flame Retardancy Zero NS 02-713/NF C 20-454 Low Toxicity IC60754-2 N50267-2-2/3 NF C 32-074 Low Corrosivity IC 61034-1&2 N 50268-1&2/NF C32-07 Low Smoke mission IC60754-1 N50267-2-1 DIN 4102-12 Functional Integrity ADDISON 33

ADDISON Fire Resistant RG11 A/U Coaxial Cables RG11 A/U FR Plain Copper ire Braid P/FP Insulation Tinned Copper Fire Resistant Tape LSZH Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. Standards Basic design to MIL-C-17 FIR PRFORMANC System Flame Retardance (Single Vertical ire Test) (Vertically-mounted bundled wires & cable test) IC 60331-23; BS 6387 CZ; DIN VD 0472-814(F180); CI 20-36/2-1; SS299-1; NBN C 30-004 (cat. F3); DIN 4102-12, 30 depending on lay system N 60332-1-2; IC 60332-1-2; BS N 60332-1-2; VD 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CI 20-35/1-2; N 50265-2-1*; DIN VD 0482-265-2-1* N 60332-3-24 (cat. C); IC 60332-3-24; BS N 60332-3-24; VD 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CI 20-22/3-4; N 50266-2-4*; DIN VD 0482-266-2-4 IC 60754-1; N 50267-2-1; DIN VD 0482-267-2-1; CI 20-37/2-1 ; BS 6425-1* No Corrosive Gas mission IC 60754-2; N 50267-2-2; DIN VD 0482-267-2-2; CI 20-37/2-2 ; BS 6425-2* Minimum Smoke mission IC 61034-1&2; N 61034-1&2; DIN VD 0482-1034-1&2; CI 20-37/3-1&2; N 50268-1&2*; BS 7622-1&2* No Toxic gases NS 02-713; NF C 20-454 Note: Asterisk * denotes superseded standard. 34 Caledonian

Caledonian Fire resistant Coaxial Cables www.caledonian-cables.net www.addison-cables.com CABL CONSTRUCTION Conductors: Tinned copper copper wire, stranded according to IC 60228 class 2. Insulation: Low density P wrapped with fire resistant silicone rubber compound type I2 as per BS 7655-1.1 or fluoropolymer(fp) compound. Binder: Glass tape Overall Screen: Plain copper wire braid Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type S2-S4 as per BS 7655:section 2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Physical AND THRMAL PROPRTIS Temperature range during operation (fixed state): -30 C - +70 C Temperature range during installation (mobile state): -5ºC - +60ºC Minimum bending radius: 8 x Overall lectrical Properties Impedance 75±5Ω Capacitance Velocity ratio(%) 66 Insulation resistance Shield coverage 97% DC resistance Inner conductor Outer conductor Attenuation 67 nf/km >2000 Mohm.Km 20.5 Ω/km 4.5 Ω/km Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) 50 4.2 1.28 100 6.2 1.89 200 9.3 2.84 400 13.8 4.21 500 15.5 4.73 600 17.1 5.21 860 20.1 6.13 1000 23.4 7.13 ADDISON 35

ADDISON Return Loss Frequency(MHz) Return Loss (db) 30-300 MHz >30dB 300-600 MHz >27dB 600-900 MHz >25dB CONSTRUCTION PARAMTRS Cable Code Conductor Insulation Screen No.x Overall Approx. eight mm mm No. x mm mm kg/km RG11 A/U FR 7 x 0.40 7.25 ± 0.18 192 x 0.18 10.3 ± 0.18 150 300/500V MIL-C-17 N Rated Voltage Standard IC 60331/BS 6387 NF C32-070-2.2(C1) IC60332-3-24/N50266-2-4 NF C32-070-2.1(C2) IC60332-1-2/N50265-2-1 Flame Retardancy Zero NS 02-713/NF C 20-454 Low Toxicity IC60754-2 N50267-2-2/3 NF C 32-074 Low Corrosivity IC 61034-1&2 N 50268-1&2/NF C32-07 Low Smoke mission IC60754-1 N50267-2-1 DIN 4102-12 Functional Integrity 36 Caledonian