TGD Part B Fire Safety Volume 2 Dwelling Houses. Chris Barry B.Sc.,M.Sc., Pg. Dip. FSP, H.N.C. NDFEM

Similar documents
Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)

Agency for Health Care Administration

Agency for Health Care Administration

T e c h n i c a l G u i d a n c e D o c u m e n t. Fire Safety. Dwelling Houses. Volume 2

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Fire precautions in dwellings

Report on First Revisions with Statement June 2014 NFPA 101

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

Northern Ireland HMO Fire Safety Guide

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Building Regulations Update. by Eamonn Smyth

CHAPTER 7 ALTERATIONS LEVEL

Design of Fire safety in Multi Occupancy Residential Accommodation

Residential Care Facilities Requirements

Chapter 2: Definitions

Agency for Health Care Administration

SAF-BCF SECOND REVISIONS WITH STATEMENTS

Element C3.5 Means of Escape

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

The one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1.

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

BUILDER S PRE-INSPECTION CHECKLIST

CHILD CARE CENTER INSPECTION CHECKLIST 06C

Bristol City Council Private Rented Sector Fire Safety Standards

BUILDER S PRE-INSPECTION CHECKLIST

2012 B.C. Building Code Compliance Review (Division B Part 3)

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

Short Term Accommodations Fire Code Requirements

Approved Document. Fire safety. Volume 1 Dwellinghouses. The Building Regulations Came into effect April 2007

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

Technical Seminar on the Code of Practice for Fire Safety in Buildings 2011

BCBC 2012 CHANGES TO PART 3

97 FCV 006 Page 2 of 16 EXPLANATORY MATERIAL

Major Changes to the 2010 National Construction Codes Contractor s Breakfast January 2014

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.

2012 International Fire Code Significant Changes. IFC Background. Purpose IBC and 2012 NFPA 101 Significant Means of Egress Changes

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

Nirmal Chandra Sinha. Supposed to complete(dd/ MM/YYYY) Comments after Physical Inspection

- CONSTRUCTION FIRE SAFETY STANDARDS

IFC Significant Changes from the 2009 to the 2015 Edition Tier 1

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NO 68 (ENGLISH AND PHILOSOPHY)

1.4 Provide and fix the following ironmongery.

CHAPTER LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE, 2000 EDITION SECTIONS

Residential-based Care Facility R-4 Guideline

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017

Electrical Tech Note 107

2006 edition. Fire safety APPROVED DOCUMENT VOLUME 1 DWELLINGHOUSES. The Building Regulations 2000

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

The Code of Practice for Fire Safety in Buildings 2011 It comprises 7 parts and 1 annex:

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work.

Agency for Health Care Administration

A PRACTICAL FIRE SAFETY GUIDE FOR SMALL SELF-CATERING PREMISES

Smoke & Carbon Monoxide

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

City of South Salt Lake Fire Code Training Exiting, Egress Systems and Egress Control

Unit 2 Fire Safety (Zone 1)

PERFORMANCE COMPLIANCE METHODS

Schedule of works required for Fire Protection in a 2 Storey semi-detached/terraced house

CHAPTER 5 - STRUCTURAL FIRE PRECAUTIONS

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

BCAC Egress Work Group

Agency for Health Care Administration

WORKSHEET 4-1 THE MANITOBA FIRE RISK INDEX FOR THE RESIDENTIAL OCCUPANCY OF HERITAGE BUILDINGS FIRE SAFETY PARAMETERS

BS 5839 Part 6 : 2013 Changes. By Don Scott

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

2012 International Fire Code Errata (Portions of text and tables not shown are unaffected by the errata)

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS

Plan Review Check List Fire Alarm System

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

For additional information regarding R-3.1 residential care facilities please contact (951)

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT SPORTS CENTRE

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

BUILDING CODE OF THE CITY OF NEW YORK. New York City Department of Buildings 4 June 2007

Kensington Aldridge Academy, London W10

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

Learning from incidents IFE AGM and Conference 2014 Intelligent Engineering Reducing Risk 25 th and 26 th June 2014 Stratford on Avon

Short-Term & Accessory Short-Term Rental Safety Certification

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Egress Window. Requirements for Building Permit Application

150 Elgin - Office Tower and Grant House Renovations

BC Building Code Checklist Part 3 Planning and Development Department

January 1, 2014 Mandatory Effective Date

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

Agency for Health Care Administration

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

COMPLIANCE ALTERNATIVES

COMPLIANCE ALTERNATIVES

WELSH GOVERNMENT DOMESTIC FIRE SPRINKLER PILOT STUDY. Colin Blick Building Standards Technical Manager Welsh Government

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Fire and Life Safety Review Form

Large Family Daycare Guideline

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

SPECIAL DETAILED REQUIREMENTS BASED ON USE AND OCCUPANCY

Transcription:

TGD Part B Fire Safety Volume 2 Dwelling Houses Chris Barry B.Sc.,M.Sc., Pg. Dip. FSP, H.N.C. NDFEM

Presentation Overview Review Rationale Review Process Legislation-Structure Section 0-Section 5 Appendix A-Performance of Materials and Structures Appendix B-Fire Doors Appendix C-Measurement Appendix D-Loft Conversions Conclusion

Rationale for the review of T.G.D. Part B Fire Safety Current version of T.G.D. Part B published in 2006, following some amendments to the previous 1997 version. The 2006 amendments - relatively limited in scope and much of the provisions of the1997 version were retained Main drivers for the review: Now 21 yrs. since a substantial review Developments in materials and methods of construction Changes in other T.G.D. -Update provisions codes of practice Developments in international fire safety standards EU regulations

The review Process Consultancy report on enhanced FDAS Research/ Discussions/ Int. Best practice Stakeholders Conference TGD Part B Conferences/ Professional networking Review steering group Public Consultation: Two stage process

Legislation/Structure; New two volume structure : Vol.1 Buildings other than dwellings - Vol 2 Dwelling houses Publication of TGD B Vol 2: new S.I. 57/2017Building Regulations(Part B Amendment) Regulations 2017. Allows changes in legislation to accommodate reference to means of warning and new definition of dwelling house New additional functional requirements of the building regulations B6-B10 arranged in Section 0 - Section 5 of TGD Commencement date 1 st July 2017 Existing TGD Part B 2006 : Existing functional requirements B1-B5 contained in Section 1 Section 5 to continue address requirements for Buildings other than dwellings for interim period.

Section 0 Introduction Removal of ref to CPD / CPR /Progress/Standards cited etc.-see Part D 0.1.5 New category of dwelling: Purpose Group 1(d) Community Dwellings 0.1.16 Independent schemes of certification-new reference 0.1.7 All definitions consolidated in this section -Additional definitions: Community dwelling house- Dwelling: a house or flat, forming a separate unit of residential accommodation- Dwelling House: means a dwelling that is not a flat( as defined IS 497 of 1997) Gallery: is a floor or storey which consists of a raised area or platform which projects into the space of the room, providing extra floor area 0.1.9-Ref to Conversion of Traditional Buildings2-Historic Scotland 0.1.10 Operation, maintain and use - FDAS

Section 1 Means of warning and escape in case of fire 1.3.2.1 Open plan relaxation Diagram 1- to clarify existing provisions

Section 1 Means of warning and escape in case of fire(contd.) Diagram 4 Fire separation in dwelling houses With more than one floor 4.5.m above G.L. To clarify exist provisions in 1.3.4.(c)

Section 1 Means of warning and escape in case of fire(contd.) Diagram 3 Means of escape from dwelling houses 1.3.4 requirement for sprinklers in(all)timber frame dwellings greater than 3 stories - BS 9251 1.3.6 F.D.A. S. Designed for the protection of life to I.S. 3218 (currently BS 5839) L.D. 2 to PG1(a),1(b) L.D. 1 to PG1(d) +control switch

Section 1 Means of warning and escape in case of fire(contd.) 1.3.6.4 Extensions New Diagram 5 Enclosed rear gardens place of safety 1.3.7.1 windows for escape or rescue (b)simplified wording only reference egress requirement: ref to 800mm cill height removed (c)reference to limits of application of Part K(1400mm) 1.3.9.7 Final exits should be provided with simple fastenings (thumb latches or other readily openable mechanism) which can be operated from the escape side without the use of a key.

Section 1 Means of warning and escape in case of fire(contd.) 1.3.7 Windows for escape or rescue Remove angled approach 1.3.7 2 Replacement windows: Should meet. replaces recommended 1.3.9.3 Ducts New provisions for dwellings reference to BS 9991 protection of escape route (stairs enclosure)only 1.3.9.6 Professional rooms New Provision of linked fire alarm emergency light(s) directional signage (Note 1: Table 0.1 does not include PG 1(d))

Section 1 Means of warning and escape in case of fire(cont.) 1.3.9.9 Galleries Treated as a storey to comply to 1.3.2, 1.3.3, 1.3.4 Requires fire resistance to floor Second means of escape (window or door) Gallery designated only where: It is not designed as a sleeping area Does not project into more than 50% of room 3m travel distance to door in room 7.5 m from of stairs head to any point on gallery Cooking facilities either: Enclosed in storey height construction Not less than 3m from stair(see dig 1) Does not prejudice escape from gallery

Section 1 Means of warning and escape in case of fire(contd.) 1.3.5 Community Dwelling Houses P.G. 1(d) A Dwelling house with a maximum of 8 bedrooms which may have no more than one storey, the floor level of which is more than 4.5m above ground level occupied as a group home, under the management of a statutory or voluntary organization providing supported living and residential services. Height 3 stories, No basements 30min. fire resistance to corridors/stairs enclosure regardless of no. of storeys. Free swing doors Emergency llluiminaires Max. eight bedrooms Reference to C.O.P. management-risk assessment 1.3.6 LD1 FDAS to I.S. 3218 + control switch Increased coverage Bedrooms+ attics+ other spaces

Fire Services Acts 1981&2003 Part III, Section 18(1) Single family dwelling : excluding premises consisting of a dwelling house occupied as a single dwelling Sections 18-23 may be applied -including Powers of inspection- duties and responsibility of persons in control Planning and Development Acts 2000 Planning and Development Regulations 2001 Section 14(f):New build : Exempt from planning permission group home.not exceeding 6 +2 carers Section 5: Exempt from planning permission <40m 2 /to rear of dwelling Building Regulations 1997-2017 TGD Part B Fire Safety Provide Prime Facia compliance with requirement of building regulations Building Control Acts1990 & 2007 Vol. 2 B6-B10 provisions for meeting functional requirements. Pg 1(d) Community Dwelling houses Building Control Regulations 1997-2015 Not required to carry out works Material alteration invoked only where works taking place involve Parts A,B,M Material change of use only where a non-dwelling is to be put to use as a community dwelling house Material change of use occurs only where a non-dwelling is to be changed to a community dwelling house Code of practice for fire safety in new and existing Community Dwelling houses Exemption under SI 496 Part III, Article 11(2) (b) buildings used as a dwelling other than a flat No DAC required

Section 2 Internal Fire Spread (Linings) 2.6.3 Diagram 7 Clarification on existing provisions with respect to light fittings attached to a ceiling

Section 3 Internal Fire Spread (Structure) 3.5.3 Limits to Compartment sizes Clarification on extent of compartmentation required in dwelling houses. 3.5.4.3 exception to requirement for non combustible separating walls only allowed in T.F. construction to IS 440 3.5.4.6 Diagram 10 Junction of separating wall and roof 3.6.2 Provision of cavity barriers Deletion of Dig. 17 Clarification of requirements Diagram 12 Vertical cavity barrier at junction of separating wall 3.7.8. Highlight Reference to ASFP publications

Section 4 External Fire Spread 4.5.7 Diagram 16 Unprotected areas-revised diagram 4.5.8.1 Diagram 17 New diagram and requirement on the effect of a Canopy on separation distance

Section 5 Access and facilities for the Fire Service 5.4.2 Provision of Vehicle access-45m to principal entrance 5.4.4 Design of access roads within site of dwelling house Table 5.1 Note: includes reference to a hammerhead and Recommendations for site development works for housing areas 1998 5.4.5.1 Photovoltaic Panels provision for isolation ref ET101 requirements

Appendix A Performance of Materials and Structures A 21 Structural fire design- additional Reference to Eurocodes and Fire Parts of Structural Eurocodes Application of EU Test methods-design to Eurocodes Application BS 476-existing buildings-non structural elements of new buildings.

Appendix B Fire Doors B2 -Free swing self closing device allowed in P.G.1(d) Appendix C Methods of Measurement Diagrams upgraded

Appendix D Loft Conversions Applies to existing two storey dwelling Only to Conversions: <50m2 or contain more than two habitable rooms Larger loft conversions in to comply with provisions in 1.3.2,1.3.3 D 2.2 New stairway in fire resist const. extended to main stairway enclosure D 2.3 Single fire door leaf may be allowed(certified) D 2.5 Floor in Domestic loft conversions: modified 30min. allowed in exist and new D3 provisions moved from Section 3 Fire resistance of timber floors D5 FDAS radio interconnected alarms+ 10 year battery permitted D6 External fire spread note limitations on unprotected areas in Section 4 External fire spread.

Thank you chris.barry@housing.gov.ie