Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

Similar documents
Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Electronically controlled instantaneous water heater. DSX: : C models. Instructions for the user

Electronically controlled instantaneous water heater

Zip InLine. Models CEX-O & CEX-U Issued August Installation, Maintenance and User Instructions

Electronically Controlled Instantaneous Water Heaters Models: CEX-O & CEX-U

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

Zip Domestic Chill Tap

Zip Domestic ChillTap

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

Electronic Instantaneous Water Heaters Models: ES3, ES4 & ES6

Zip HydroTap Miniboil

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

Zip Chilltap Extra. Affix Model Number Label Here Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Zip InLine Electronically controlled instantaneous water heaters.

CTA15-2 warming drawer. operating and installation instructions

Zip Autoboil Installation and Operating Instructions

Miniboil Boiling Only

Instructions for Use Warming Drawer. Bedienungsanweisung Wärmeschublade. Notice d'utilisation Chauffe-vaisselle. Gebruiksaanwijzing Servieswarmer

Installation Instructions. Filtered Boiling and Boiling Ambient drinking water for commercial kitchens and tea rooms.

Mira Sport Thermostatic

Convection Panel Heater

The Professional s Choice

V 120 SG - V 160 SG. Instructions for use

87cm. Cooker hood. Stainless steel JLCEILHD87. User guide

INSTRUCTIONS AND WARRANTY

Owner s Guide and. Gas Continuous Flow Water Heater 27L Gas Water Heater 874 & 872 Series, 627 Models

Installation and user manual

Friwa Compact. Operating instructions EN

Zip Autoboil. Installation and Operating Instructions

Mira Advance THERMOSTATIC ELECTRIC SHOWER. 8.7 and 9.8 kw. These instructions must be left with the user. User Guide W5-A

ZIP HydroTap G4 Celsius User Guide

Induction Cooktop User's manual

instructions OIL FILLED RADIATOR V V and V551225

EN Variable Temperature Electric Kettle

TK 806 Z. Bedienungs- und Wartungshandbuch. Livret d instructions et d entretien. Manuale uso e manutenzione. User instructions and maintenance

Induction Cooktop User's manual

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

DIGITAL KITCHEN SCALE

KOSPEL S.A KOSZALIN UL. OLCHOWA 1

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

HEALTH & SAFETY AND INSTALLATION GUIDE

V150 SG2E / V190 SG2E. Instructions for use

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

TECHNICAL PROPERTIES OF THE APPLIANCE

INSTRUCTIONS AND WARRANTY

MODULAR AUTOMATIC GRANULAR ICE FLAKER

Portable Electric Patio Heater User's manual

INSTRUCTIONS AND WARRANTY

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

Aquience 1200/1500 R

Zip HydroTap. B & BA Residential. Affix Model Number Label Here Installation Instructions

Installation Instructions Zip HydroTap G4 CS Residential Affix Model Number Label Here

Vacuum Pack Machine Instruction Manual Model GF439-A

INSTALLATION AND OPERATION MANUAL

BLOW DRY & GO HAIR KIT

VADA - Rain2Main Automatic Rainwater Controller

5KMT2115 W A_01_EN_v10.indd 1 3/20/17 3:24 PM

Operating Instructions

MW402 Integrated Dishwasher

INSTRUCTIONS AND WARRANTY

Domestic Hot Water Tank

Mira Vision Wireless Controller

AUS. Devireg TM 535 Installation and user manual

MW401 Integrated Dishwasher

Water Boiler. Instruction manual. Model: GL346-A/GL347-A/GL348-A/GL349-A

1.6kW Window / Wall Air Conditioner

SHOWER WATER HEATER MODEL X-SLIM 35 EC / X-SLIM 45 EC OPERATION AND INSTALLATION INSTRUCTIONS

Operating and assembly manual: Electric instantaneous flow heater Admiral

Operating Instructions

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

User Manual for model

MW001 Integrated Dishwasher. Manual for Installation, Use and Maintenance

INSTRUCTIONS AND WARRANTY

HR 601 C A AUS. ENGLISH Instructions for use Page 2

OPERATING AND INSTALLATION MANUAL

Flow Factor ~

INSTRUCTIONS AND WARRANTY

V-ZUG Ltd. Range hood. Levante. Operating instructions

Health & Safety and Installation guide

WIRELESS MEASUREMENT SYSTEM OF GAS BOTTLES FILLING LEVEL WITH GAS LEAK DETECTION GMS 300. User Manual

SYGMA INSTRUCTIONS MANUAL SYGMA DIGITAL ELECTRIC RADIATOR MOUNTING, INSTALLATION, STARTING AND OPERATION

Radiant Heater. Instruction Manual QH-200 N13275

Zenith ChillTap Sparkling

Multi Wet & Dry Vacuum Rechargeable 10286

Operation Instructions. Model:XS-510

BEFORE USING THE DISHWASHER/CONNECTIONS

Operating instructions

Zip Chillmaster Floor Mounted Chiller

The Professional s Choice

JLBIHD624 60cm Cooker Hood

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

SEVILLE KETTLE INSTRUCTIONS & WARRANTY 2 YEAR WARRANTY 18152AU 18152AU_IB_FA_240712

MODEL NO RUSSELL HOBBS APOLLO 1.8L DIGITAL FILTER COFFEE MAKER

OPERATING MANUAL COST CONTROL - POWER CONSUMPTION MONITOR

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

Transcription:

Electronically controlled instantaneous water heater CEX 9 CEX9: 27900-50 C models Instructions for the user For 50 ºC models, the appliance delivers water not exceeding 50 ºC in accordance with AS3498.

. Overview When ordering spare parts, please always specify the appliance model and serial number. 2 2 3 0 4 9 5 6 8 7 Pos. Part.-No. Description Pos. Part.-No. Description Grommet 2 Connecting terminal 3 800 Flow sensor 4 800 Non-return valve 5 804 Electronic CEX 9 6 Inlet pipe 7 805 CEX cover 2 8 Hot and cold water connection /2 9 806 Temperature sensor set 0 807 Heating element with STCO (STDB) Bottom part 2 Screws and dowels Parts in Bold Type are available as Spare Parts. Other parts are available on request.

Contents. Overview............................................................................................... 2 2. Environment and recycling.................................................................................. 3 3. Safety instructions........................................................................................ 4 4. Technical specifications.................................................................................... 5 5. Dimensions.............................................................................................. 5 6. Typical installations........................................................................................ 6 7. Description of appliance.................................................................................... 7 8. Operation............................................................................................... 7 9. Reset to factory setting..................................................................................... 8 0. Additional features....................................................................................... 8. Cleaning and maintenance................................................................................. 9 2. Fault finding............................................................................................ 9 2. Environment and recycling This symbol on the products and / or accompanying documents means that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling, please take these products to designated collection points. Alternatively, in some countries you may be able to return your products to your local retailer upon the purchase of an equivalent new product. Disposing of this product correctly will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappro priate waste handling. Please contact your local authority for further details of your nearest designated collection point. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation. If you are a business user and you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information. This symbol is only valid in the European Union. 3

3. Safety instructions Installation, initial operation and maintenance of this appliance must only be conducted by an authorised professional, who will then be responsible for adherence to applicable standards and installation regulations. We assume no liability for any damages caused by failure to observe these instructions. Do not use the appliance until it has been correctly installed and unless it is in perfect working order. The appliance is suitable but not limited to domestic use and similar applications inside closed, frost-free rooms, and must only be used to heat potable water from mains supply. The appliance must never be exposed to frost. The appliance must be earthed at all times. The minimal specific water resistance must not fall below the value stated on the label. The maximum water pressure must not exceed the value on the label. Before commissioning for the first time and each time the appliance is emptied (e.g. due to work on the plumbing system, if there is a risk of freezing or in case of maintenance), the appliance must be vented correctly in accordance with the instructions in this manual. Do not remove the front cover under any circumstances before switching off the mains electrical supply to the unit. Never make technical modifications, either to the appliance itself or the electrical leads and water pipes. Pay attention to the fact that water temperatures in excess of approx. 43 C are perceived as hot, especially by children, and may cause a feeling of burning. Please note that the fittings and taps may be very hot when the appliance has been in use for some time. Water inlet temperature must not exceed 70 C. In case of malfunction, disconnect the fuses immediately. In case of leaks, cut off the cold water supply instantly. Repairs must only be carried out by the customer service department or an authorised professional. This appliance must not be used by any person (including children) with limited physical, sensorial or mental abilities or failing experience and/or knowledge unless they are supervised by a person responsible for their safety or received instructions about how to use the appliance. Children should be supervised in order to make sure that they do not play with the appliance. 4

WMKA3006 AS 3498 4. Technical specifications Model CEX 9 ELECTRONIC MPS Part no. 27900 Rated capacity / rated current 6,0 / 9,6 kw (27,3 / 40 A) Chosen capacity @ 230 V 6,6 kw (28,7 A) 8,8 kw (38,3 A) Electrical connection /N/PE 220..240 V AC Min. required cable size 3) See note 3) Hot water (l/min) max. at t = 25 K 3,8 5,0 Rated volume Type 0,3 l Pressure type MPa (0 bar) Heating system bare wire heating system IES Required spec. water resistance @ 5 C Spec. electrical conductivity 00 cm 90,9 ms/m Inlet temperature 70 C Flow rate to switch on max. flow rate 2,0 5,0 l/min ) Pressure loss 20 kpa / at 2,5 l/min 30 kpa / at 9,0 l/min 2) Temperature range 20 C 50 C Water connection G ½ Weight (when filled w. water) 2,7 kg VDE class of protection I Type of protection / safety IP25 ) Flow rate limited to achieve optimum temperature rise 2) Without flow regulator 3) The cross sectional area of the connection cable must be in accordance with the power rating of the appliance and the specific requirements of AS/NZS 3000. 5. Dimensions Dimensions in mm 5

6. Typical installations 6

7. Description of appliance The Zip Instantaneous Hot Water heater CEX 9 is a microprocessor-controlled, pressure-resistant water heater for a decentralised water supply to one or more tap connections. Its electronic control regulates the power consumption depending on the selected outlet temperature, the respective inlet temperature and the flow rate, thus reaching the set temperature exactly to the degree and keeping it constant in case of pressure fluctuations. The required outlet temperature can be entered between 20 C and 50 C and is indicated on the digital display. This appliance delivers water not exceeding 50 ºC in accordance with AS3498. 8. Operation The appliance switches on automatically when the hot water tap is opened and switches off automatically when the hot water tap is closed. Set temperature - C + C Temperature setting The required outlet temperature can be adjusted gradually to a higher or lower value with the up arrow and down arrow keys. Pressing a key once briefl y changes the temperature by 0.5 C between 35 C and 42 C and by C outside that range. Pressing a key for a longer time changes the temperature continuously. The required outlet temperature can be adjusted between 20 C and 50 C. Note: reducing the temperature below 20 C displays - - and the heating function will not operate. A 35.0-42.0 C -0,5 C +0,5 C Select preset temperature A2 Program buttons The two program keys allow a preset temperature to be selected quickly. The factory setting is 35 C for program and 48 C for program 2. The preset temperature can be changed to the current temperature setting by prolonged pressing of the program key. The display changes from P or P2 to the new temperature value which becomes available each time the corresponding program key is pressed. B B2 Store temperatures 2 7 4 Set required temperature 3 Press >3 seconds

9. Reset to factory setting To reset to factory settings press the up arrow and down arrow function keys simultaneously. The display will count backwards from 0 to 00 in one second intervals. The appliance is reset when the counter reaches 00. Releasing the function keys earlier will cancel the process. Press + Reset to factory setting 2 + 3 Reset com- 0. Additional features Energy saving Set the required hot water temperature on the appliance. If the water is too hot reduce the temperature on the appliance instead of mixing with cold water. Adding cold water wastes valuable energy that has been used producing excessively hot water. Also, any cold water added is not controlled by the electronic circuitry meaning that precise temperature control can no longer be guaranteed when supplying more than one outlet. Power limit If the maximum power available from the appliance is insuffi cient to heat the volume of hot water being drawn off to the required temperature this will be indicated by MAX on the display. Reducing the fl ow rate will enable the required temperature to be delivered. Energy saving mode Power limit Operation with solar systems The appliance is suitable for use with solar heating systems providing appropriate controls are in place to ensure that the temperature of the water entering the unit does not exceed 70ºC. If the inlet temperature exceeds the set point, the SUN symbol on the display indicates that the heating power is switched off. Heating is switched off 8

. Cleaning and maintenance N.B. Maintenance work must only be carried out by a qualifi ed tradesperson familiar with instantaneous water heaters. Plastic surfaces and sanitary fi ttings should only be wiped with a damp cloth. Never use abrasive cleaning agents or solvents. Outlet fittings (tap nozzles and shower heads) should be unscrewed and cleaned at regular intervals. The electrical and plumbing components should be inspected regularly by a qualifi ed tradesperson to ensure proper functioning and operational safety. Water quality should be considered when determining the frequency of inspection. Each time the appliance is emptied (e.g. due to work on the plumbing system, if there is a risk of freezing or in case of maintenance), the appliance must be vented by opening and closing the hot water tap until all air has been eliminated from the water heater and no more air emerges before re-connecting to the electrical supply. 2. Fault finding Repairs should only be carried out by qualifi ed tradespersons familiar with electric instantaneous water heaters. All service work should be performed by an authorized Zip service technician for details of the full range of services available call Zip Service on 800 460 222. When calling for service, please always specify the appliance model and serial number. The following table will be helpful in determining the causes of some common problems and their solutions. Problem Cause Solution Circuit breaker tripped Reset circuit breaker Water stays cold STCO tripped Contact Zip Service to reset STCO Display fl ashes error message ER Poor hot water fl ow rate Selected temperature not achieved MAX lights up Selected temperature not achieved MAX does not light Control system has switched off Outlet fi tting dirty or calcifi ed Fine fi lter dirty or calcifi ed Excessive water fl ow rate Cold water has been added at the outlet Switch power supply off and on. If ER still fl ashes contact Zip Service Clean shower head or tap nozzle Contact Zip Service to clean fi ne fi lter Reduce water fl ow rate at the outlet Set for required temperature and tap hot water only Symbol SUN fl ashes Inlet temperature exceeding set point Reduce inlet temperature Water heats up but display fails to operate Display lead plug not properly connected 9 Contact Zip Service to connect display lead correctly

3. Notes. Notizen. Notes. Notes. Notas 0

3. Notes

Head Office Zip Heaters (Aust) Pty. Ltd. ABN: 46 000 578 727 67 Allingham Street Condell Park NSW 2200 Postal: Locked Bag 80 Bankstown 885 Australia Website: www.zipheaters.com Facsimile: (02) 9796 3858 Telephone: (02) 9796 300 Free Call: 800 638 633 As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods. Quick reference guide MADE IN GERMANY programme button arrow key up programme button 2 arrow key down Set temperature C + C Power limit + Press 2 sec Enter service menu 2 Convenience zone 35,0..42,0 C 0,5 C +0,5 C Unit provides no output 4 3 A Select preset temperature A2 + Reset 2 5 Display flashes 6 B B2 Press + hold! 3 9 8 7 Store temperature Set required 2 temperature (e.g. 43 C) 4 3 Display of new value (e.g. 43 C) Press 3 sec Reset completed