Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

Similar documents
AP-EH500-L/RQA9837. Installation Guide

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

XB-EFA-8L-BK & XB-EFA-8R-BK

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

ECOSMART TWINFANS. (EST-X/R/B) 1 phase, Direct Drive, Run & Standby For External, Roof Mounted and Internal use Installation and Maintenance

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

INDOOR USE ONLY. Installation and Maintenance XTRACTOR. (ESX) 1 and 3 phase, Direct Drive, Fans for indoor use

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

ECOSMART XTRACTOR. (ESX-X/R/B) 1 phase, Direct Drive For External, Roof Mounted and Internal use Installation and Maintenance.

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

MEV Ecosmart. Installation and Maintenance. Continuous Mechanical Extract Ventilation Units. 1.0 Introduction

DRIMASTER Anti-Condensation & Whole House Ventilation Unit Installation and Maintenance

Sunwarm Air Solar Energy Ventilation System Installation and Maintenance Details for:

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

DRIMASTER 2000 and DRI S Anti-Condensation & Whole House Ventilation Unit Installation and Maintenance

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance

AXUS - SC Short Cased Axial Flow Fans Installation and Maintenance

Ecosmart Boxer. AHU s (Fan Speed Control only) Installation and Maintenance. LPHW Heater

MRXBOX90S. Mechanical Ventilation with Heat Recovery. Installation and Maintenance

Application and Installation Guide for sunwarm system (excluding Solar Air Collectors)

Installation and Maintenance. Opus OK / Genie NKF1 Kitchen Extract Unit. Contents IMPORTANT WARNING IMPORTANT! Introduction WARNING!

Application and Installation Guide for sunwarm140 AHU system (excluding Solar Air Collectors)

Application and Installation Guide (excluding Solar Air Collectors)

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

SURFACE WARM CEILING HEATERS

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan with Humidity Enabler Installation Guide

Installation and Maintenance

DAVE Supply (DS) Fans For Internal & External Use Installation and Maintenance

XBOXER 55. Supply & Extract Ventilation Unit with Heat Recovery Installation, Operating and Maintenance Instructions XB 55 - L - E

DAVE Supply Fans (ES Models) For Internal and External use

Surface Warm Ceiling Heaters

BESPOKE BOXER AIR HANDLING UNITS. Installation and Maintenance Instructions


Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

sunwarm air Application and Installation Guide (for Solar Air Collectors)

Installation and Maintenance. OPUS 30 and 60. Duct Mounted ('M' range) Domestic Extract Fans IMPORTANT WARNING

Installation, Operation and Maintenance Instructions Document Ref:

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan Installation Guide. Fig. 2 Fan components.

Installation, Operation and Maintenance Instructions Document Ref:

Panther Fan Coil Units

EST 19H & 20H 3ph Run & Standby, Roof & Plantroom Twinfans

AIR CURTAIN HX RECESSED RANGE

Installation, Operation & Maintenance Instructions Document Ref:

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

LANDLORDS & LETTINGS VENTILATION SOLUTIONS

EVH Hybrid Ventilation Unit

Recessed Warm Ceiling Heaters

RECESSED WARM CEILING HEATERS MODELS HSRCH3000RF, HSRCH4500RF INSTALLATION AND OPERATING MANUAL

ACTIVE VENTILATION SYSTEMS

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

ecovent NRGP Air Handling Units

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Installation and Wiring Instructions

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Copperad. Copperad Fan Convectors (November 2005 onwards) Installation, Operation and Maintenance Instructions To be retained by the user

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

RE-PR3-E-27 3-Phase Panel Mount 27kW

Constant Pressure, Belt Drive Run & Standby, Roof & Plantroom Single & Twinfan Units Installation and Maintenance

Xcell 270 Longlife DC wholehouse heat recovery unit

Sargasso Range. Installation manual. Sargasso S. Issue 001 January 2018 ENGLISH UK IRL SmithsEP.co.uk

WIRING DIAGRAMS AND OTHER RELAVENT LITERATURE WITH THE END USER. access panel Fan speed and on/off switches. Discharge spigot. Fan/motor.

Commercial Fan Heater

EVG Extractors. Manual for Installation, Use and Maintenance

XTRACTOR - 3 phase Belt Drive

INCORPORATION & INSTALLATION INSTRUCTIONS. For incorporating a heat pump control system by others

SMOKE CONTROL - NEW DIRECTIONS

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Installation and Maintenance

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Installation, operation and Maintenance Manual

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Cooling Strip Model SPB

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

AIR CURTAIN T SURFACE MOUNTED RANGE

Installation and Maintenance

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

9 inch and 12 inch Axial Fans Models MV230P, MV230AR and MV300AR Instructions for installation, maintenance and safe use.

BSK-RPR Fire Damper. Additional operating instructions according to

Installation, Operation & Maintenance Instructions Document Ref:

Warnings, Safety Information and Guidance

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

XBOXER XBC UNIT SIZES WITH ECOSMART ADAPT (SIEMENS) CONTROL (AS)

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

Lo-Carbon T-series Window & Roof Models

Installation & Service Manual. Models ALF 20, 30, 40, 50, 60, 80

BKA-EN Fire Damper. Additional operating instructions according to

CENTRIFUGAL FAN IN SCROLL CASING. Helix S-Vent OPERATION MANUAL

Ocelot Fan Coil Units

Simply Silent Contour 4 (100mm) Axial Extraction Fan

EVP61/91/101/121. Extractor. Installation, use and maintenance.

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

Transcription:

Natural Ventilation e-stack A-Series Ventilation System for Buildings with Atria Installation and Maintenance The EMC Directive 004/108/EC The Low Voltage directive 006/95/EC Important Notes to Designers and Installers Atria are often designed into buildings to provide a light and airy environment which is adaptable for the needs of the occupants. By providing a flow path through the building, they can also aid the adoption of a natural ventilation strategy for the surrounding rooms. Nuaire has developed an innovative low energy approach to the ventilation of buildings where rooms are connected to a central atrium. The system can be deployed in buildings with one storey as well multi-storey buildings. In winter, high level vents or windows in the atrium are used to bring fresh cold air into the building as well to exhaust the hot polluted air. The air mixes naturally in the atrium owing to the convective flow patterns which develop in the space. The Nuaire A-series units are then used to exchange the atrium air with the occupied rooms adjacent to the atrium. In summer the building is ventilated using upflow displacement ventilation. Air enters through exterior windows in each room before flowing into the atrium through specially designed Nuaire e-stack A-Series transfer units. The air rises within the atrium and exits through the high level windows or vents at the top of the space. The large difference in height between the low level entry 1.0 Termination of fresh air and the unit exit of options warm air through the atrium creates a large buoyancy effect which draws air through the building. Controlled ventilation The ventilation system is fully controlled from a central control panel with dedicated temperature and CO sensors for each space. This allows the system to optimise the ventilation strategy for comfort and energy use. The panel also controls the high level openings in the atrium and provides a signal to the LED interface panel in each space to indicate when the windows should be opened. Figure 1. e-stack A-Series isometric. Construction A-Series Ventilation units are constructed with Galvanised steel or Zintec. The units can be supplied in Standard galvanised finish or Zintec powder coated to RAL9010 as standard. The A-Series units have been acoustically tested in accordance with BS EN 0140-10:199 and ISO 140-10:1991 and are shown to meet the requirements of BB93 Acoustic Design of Schools. 1.0 Handling Each e-stack A-Series unit is delivered to site suitable for forklift handling. (Unit weight approx 0kg). Figure. Lifting examples. Palletised.0 Installation Forklift Installation must be carried out by competent personnel in accordance with the appropriate authority and conforming to all statutory and governing regulations e.g. I.E.E., CIBSE, COHSE etc..1 Opening requirements Slings via spreaders fitted to unit with base frame 1) High-level windows in the atrium are to have a minimum total effective opening area as specified for the project. Ventilation area at high level in the atrium is provided by actuated windows and/or dampered vents behind weather louvres. These vents can be controlled from the e-stack control panel using Volt-free Contacts (VFC) or 0-10VDC control signals. Power to window actuators should be supplied by others. ) Windows or dampered vents (behind weather louvres) at low-level in the rooms to the side of the atrium should have a minimum effective opening area as specified for the project. If actuated windows or dampered vents are used, these can be controlled by the e-stack system. If manual windows are used, Nuaire will supply a red/blue open/close windows LED plate to instruct the occupants of the room on when to open their windows to get the most benefit from the system. Nuaire Limited Western Industrial Estate Caerphilly United Kingdom CF83 1NA T: 09 088 5911 F: 09 088 7033 E: info@nuaire.co.uk W: www.nuaire.co.uk 1 0. 07. 15. Leaflet Number 67153

. Installation of the A-Series units Whilst e-stack provide recommendations for the installation of supports for the units, the sizing and detailed design of the load-bearing supports must be specified and signed off by the structural engineers for the project. Two fixing methods are suggested: 1. Vertical support studding attaches to either side of a cradle which supports the e-stack unit. The cradle can be formed from a unistrut channel. Figure 3. Option 1. Unistrut channel cradle. Ventilation unit hangs from 4no. pieces of M1 studding of maximum length 100mm. Drop-rods attached to A-Series unit using welded brackets (supplied at additional cost). The bracket length is 65mm to the centre of the fixing hole. The unit is lifted into place and four M1 Studding (drop-rods) are brought through the holes on the end of the welded brackets, positioned and secured in place using a pair of M1 full nuts per bracket. (see figure 4). Figure 5. Option, close up of bracket.. e-stack mounting brackets supplied (at additional cost) and used in conjunction with drop-rods to support the units. (see figures 4 and 5). Note: A room set comprises two A-Series units. These may be positioned in a bulkhead, suspended ceiling or left visible within the space. Figure 4. Option, showing drop rods attached to unit. 0. 07. 15. Leaflet Number 67153

.3 Grille Requirements e-stack units contain fast moving fans and must have grilles on all open faces when in operation. Where the base of the unit is installed less than.7m vertical distance from the floor, specific grilles provided by Nuaire must be used. Where the unit is installed more than.7m vertical distance from the floor, grilles can optionally be provided by Nuaire..4 Installation Guidelines Figure 6. Typical installation diagram. 1810 A-500 Acoustic Baffle Roof ATRIUM SIDE Grille 460 503 Fixing Rod Unistrut Brackets max 800 Fire Damper Foam Seal (to acoustically seal) SIDE SECTION Transition Duct (ir required) A-500 Egg Crate Grille Suspended ceiling Wall Figure 7. Typical installation diagram. 1808.5 A-500 Acoustic Baffle ATRIUM SIDE Grille 190 Roof 1338 896. Fixing Rod Unistrut Brackets Suspended ceiling Fire Damper Wall HORIZONTAL SECTION Foam Seal (to acoustically seal) A-500 Transition Duct (ir required) 3 0. 07. 15. Leaflet Number 67153

.5 Electrical Installation Installation must be carried out by a qualified electrician in accordance with the appropriate authority and conforming to all statutory and governing regulations..6 Central Control Panel The control panel serving 10-0 rooms will typically be: 1500mm wide x 1500mm high x 500mm deep. Panels for smaller or larger numbers of rooms will vary in size and specification. A touch screen interface is also available at additional cost which allows testing and monitoring of current operation..7 Sensors Exterior Temperature Sensor This sensor (supplied) should be located on the exterior facade, preferably in a permanently shaded position e.g. below roof eaves. If this is not possible, it should be positioned in a location receiving minimal direct sunlight, and not on a south facing facade where the largest direct solar radiation is observed. Room Temperature and CO Sensors (combined) One (supplied) for each room containing e-stack transfer units. This should be mounted at eye-level and away from windows or doors in frequent use, as these may locally reduce CO concentrations..8 Room Indicator LED Panel This indicates to the user when to open or close the windows in installations with manually opening fagade windows. A blue LED illuminates to show when the user should shut the windows and a red LED when the user should open the windows. This display should be located where it is most visible to the occupants of the low-level windows. The room indicator panel requires a 50mm deep switch plate box. Room Indicator Panel Dimensions (mm) 146mm wide x 85mm high For good EMC engineering practice, any sensor cables or switched live cables should not be placed within 50mm of other cables or on the same metal cable tray as other cables. Figure 8. Wiring details. Central Control Panel High level atrium opening Exterior Temperature Sensor 4V DC Ext T, GND, E 30V AC Forward. 30V AC Reverse, Neutral 4V DC RT, CO, GND, E 4V DC RED, LED, 4V DC Blue LED, GND, E This number of units are required for each space e-stack A-Series Unit Room Indicator LED Interface Panel e-stack A-Series Unit Room Temperature and CO Sensor 4 0. 07. 15. Leaflet Number 67153

.9 Wiring Diagrams Figure 9. Wiring: Multiple Exterior Temperature Sensors. TB1 3 Core 1mm or greater Power in Room Interface RED 4 Core YY 5 Core BLUE ON/OFF Test Switch 4 Core CY 5 Core CY 1 3 1 3 1 Installation and Maintenance Figure 10. Electrical connections. Lower terminal strip connections are to be wired to by a site electrician when installing the units. Please use M16 compression glands provided for field wiring. Outside Temp Sensor +4v 0V SIG Room Temp/CO Sensor V+ GND RH T 3 4 C0 GND 5 6 PE 5 1 N 8 7 6 38 41 47 5 0. 07. 15. Leaflet Number 67153

3.0 Dimensions e-stack A-Series (mm) Figure 11. Plan view 1810 Nominal 1338 Securing screws to mount attenuator module assembly to fan casing assembly 503 Side view End view 4.0 Maintenance A 6 monthly inspection is required and any debris removed. 5.0 Warranty The 3 year warranty starts from the day of delivery and includes parts and labour for the first year. The remaining years covers parts only. This warranty is conditional on planned maintenance being undertaken. 6.0 Service Enquiries Nuaire can assist you in all aspects of service. Our service department will be happy to provide any assistance required initially by telephone and If necessary arrange for an engineer to call. Telephone 09 085 8400 6 0. 07. 15. Leaflet Number 67153

DECLARATION OF INCORPORATION AND INFORMATION FOR SAFE INSTALLATION, OPERATION AND MAINTENANCE We declare that the machinery named below is intended to be assembled with other components to constitute a system of machinery. All parts except for moving parts requiring the correct installation of safety guards comply with the essential requirements of the Machinery Directive. The machinery shall not be put into service until the system has been declared to be in conformity with the provisions of the EC Machinery Directive. Designation of machinery: e-stack A-Series Machinery Types: Natural Ventilation System Relevant EC Council Directives: 006/4/EC (Machinery Directive) Applied Harmonised Standards: BS EN ISO 1100-1, BS EN ISO 1100-, EN6004-1, BS EN ISO 9001, BS EN ISO 13857 Applied National Standards: BS848 Parts 1,. and 5 Signature of manufacture representatives: Name: Position: Date: 1) C. Biggs Technical Director 9. 1. 10 ) A. Jones Manufacturing Director 9. 1. 10 Note: All standards used were current and valid at the date of signature. DECLARATION OF CONFORMITY We declare that the machine named below conforms to the requirements of EC Council Directives relating to Electromagnetic Compatibility and Safety of Electrical Equipment. Designation of machinery: e-stack A-Series I & M Serial No.: 67153 Machinery Types: Natural Ventilation System Relevant EC Council Directives: 004/108/EC (EMC), 006/95/EC (Low Voltage Directive) Applied Harmonised Standards: EN55014-1, EN55014-, EN61000-3-, EN61000-3-3, EN60335--80 Basis of Self Attestation: Quality Assurance to BS EN ISO 9001 BSI Registered Firm Certificate No. FM 149 Signature of manufacture representatives: Name: Position: Date: 1) C. Biggs Technical Director 9. 1. 10 ) A. Jones Manufacturing Director 9. 1. 10 Nuaire Ltd, Western Industrial Estate, Caerphilly CF83 1NA. Note: All standards used were current and valid at the date of signature. INFORMATION FOR SAFE INSTALLATION, OPERATION AND MAINTENANCE OF NUAIRE VENTILATION EQUIPMENT To comply with EC Council Directives 006/4/EC Machinery Directive and 004/108/EC (EMC). To be read in conjunction with the relevant Product Documentation (see.1) 1.0 GENERAL 1.1 The equipment referred to in this Declaration of Incorporation is supplied by Nuaire to be assembled into a ventilation system which may or may not include additional components. The entire system must be considered for safety purposes and it is the responsibility of the installer to ensure that all of the equipment is installed in compliance with the manufacturers recommendations and with due regard to current legislation and codes of practice..0 INFORMATION SUPPLIED WITH THE EQUIPMENT.1 Each item of equipment is supplied with a set of documentation which provides the information required for the safe installation and maintenance of the equipment. This may be in the form of a Data sheet and/or Installation and Maintenance instruction.. Each unit has a rating plate attached to its outer casing. The rating plate provides essential data relating to the equipment such as serial number, unit code and electrical data. Any further data that may be required will be found in the documentation. If any item is unclear or more information is required, contact Nuaire..3 Where warning labels or notices are attached to the unit the instructions given must be adhered to. 3.0 TRANSPORTATION, HANDLING AND STORAGE 3.1 Care must be taken at all times to prevent damage to the equipment. Note that shock to the unit may result in the balance of the impeller being affected. 3. When handling the equipment, care should be taken with corners and edges and that the weight distribution within the unit is considered. Lifting gear such as slings or ropes must be arranged so as not to bear on the casing. 3.3 Equipment stored on site prior to installation should be protected from the weather and steps taken to prevent ingress of contaminants. 4.0 OPERATIONAL LIMITS 4.1 It is important that the specified operational limits for the equipment are adhered to e.g. operational air temperature, air borne contaminants and unit orientation. 4. Where installation accessories are supplied with the specified equipment eg. wall mounting brackets. They are to be used to support the equipment only. Other system components must have separate provision for support. 4.3 Flanges and connection spigots are provided for the purpose of joining to duct work systems. They must not be used to support the ductwork. 4.4 In the event of RF interference the fan may change speed. This is normal and will have no adverse effect on the fan. The speed will return to normal once the interference has subsided. 5.0 INSTALLATION REQUIREMENTS In addition to the particular requirements given for the individual product, the following general requirements should be noted. 5.1 Where access to any part of equipment which moves, or can become electrically live are not prevented by the equipment panels or by fixed installation detail (eg ducting), then guarding to the appropriate standard must be fitted. 5. The electrical installation of the equipment must comply with the requirements of the relevant local electrical safety regulations. 5.3 For EMC all control and sensor cables should not be placed within 50mm or on the same metal cable tray as 30V switched live, lighting or power cables and any cables not intended for use with this product. 6.0 COMMISSIONING REQUIREMENTS 6.1 General pre-commissioning checks relevant to safe operation consist of the following: Ensure that no foreign bodies are present within the fan or casing. Check electrical safety. e.g. Insulation and earthing. Check guarding of system. Check operation of Isolators/Controls. Check fastenings for security. 6. Other commissioning requirements are given in the relevant product documentation. 7.0 OPERATIONAL REQUIREMENTS 7.1 Equipment access panels must be in place at all times during operation of the unit, and must be secured with the original fastenings. 7. If failure of the equipment occurs or is suspected then it should be taken out of service until a competent person can effect repair or examination. (Note that certain ranges of equipment are designed to detect and compensate for fan failure). 8.0 MAINTENANCE REQUIREMENTS 8.1 Specific maintenance requirements are given in the relevant product documentation. 8. It is important that the correct tools are used for the various tasks required. 8.3 If the access panels are to be removed for any reason the electrical supply to the unit must be isolated. 8.4 A minimum period of two minutes should be allowed after electrical disconnection before access panels are removed. This will allow the impeller to come to rest. NB: Care should still be taken however since airflow generated at some other point in the system can cause the impeller to windmill even when power is not present. 8.5 Care should be taken when removing and storing access panels in windy conditions. 7 0. 07. 15. Leaflet Number 67153

Western Industrial Estate Caerphilly United Kingdom CF83 1NA T: 09 085 800 F: 09 085 8300 E: ahu@nuaire.co.uk W: www.nuaire.co.uk Technical or commercial considerations may, from time to time, make it necessary to alter the design, performance and dimensions of equipment and the right is reserved to make such changes without prior notice. 8 0. 07. 15. Leaflet Number 67153